1964 CHEVY IMPALA 561064 IMPALA



Similar documents
1963 CHEVY IMPALA. GEN IV w/ FACTORY AIR

MUSTANG WITHOUT FACTORY AIR

MUSTANG

CHEVELLE. w/ FACTORY AIR REV A 11/5/08, CHEVELLE w/ AC EVAP INSTR PG 1 OF 23

an ISO 9001: 2000 Registered Company CHEVELLE w/o FACTORY AIR REV A 1/20/08, CHEVELLE w/o AC EVAP INSTR PG 1 OF 26

an ISO 9001: 2008 Registered Company NOVA WITH & WITHOUT AC REV A 12/30/09, NOVA EVAP INSTR PG 1 OF 23

CHEVY CAMARO

CHEVY CAMARO W/ FACTORY AIR GEN IV REV A 3/13/07, CAMARO w/ AC GEN IV EVAP INSTR PG 1 OF 25

Cutlass without Factory Air

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

Perfect Fit ELITE series IN-DASH HEAT/ COOL/ DEFROST / COMFORT 1967 CHEVROLET IMPALA

Before installation it is important to know what parts you have and what the capabilities of these parts are.

1955 & 56 CHEVY CONTROL PANEL CONVERSION KIT PCA GOLL ST. - SAN ANTONIO, TX ph fax C O L D H E A T

GENUINE PARTS INSTALLATION INSTRUCTIONS

Cooling system components, removing and installing

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

INSTALLATION MANUAL INSIDE ENGINE COMPARTMENT ZZT22#R (1ZZ-FE / 3ZZ-FE) / AZT220R (1AZ-FE) FOR EUROPEAN SPEC. AIR CONDITIONING ENGLISH.

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

CUSTOM AUXILIARY FORWARD LIGHTING KIT

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Cooling system components, removing and installing

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Malibu Monte Carlo El Camino

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

COOLING SYSTEM Section Page

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Cooling system components, servicing

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

2003/2004/2005 TOYOTA COROLLA

Volkswagen Golf > VW Rabbit GTI 2006->

Part Name/Description Part Number Quantity. Power Cable

HVAC-02, Air Conditioning Troubleshooting and Repair

Cooling system components, removing and installing

INSTALLATION INSTRUCTIONS

MDT5N25 & MTD5N40 SERVICE PARTS

A4 Air Conditioning Control Circuit Troubleshooting Rev 7, 6/18/2009

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Installation Instructions

AIR CONDITIONING SYSTEM

COOPER S PULLEY UPGRADE KIT INSTALLATION INSTRUCTIONS PART NUMBER NME5011

Installation Instructions

INSTALLATION INSTRUCTIONS

Part Number:

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

QT Residential Blower Metal Residential Blower

with installation dynafact boost GAUGE this manual is for use with systems

TOYOTA TACOMA HANDS FREE BLU LOGIC Preparation

Solstice/Sky Water Pump Replacement

BODY ELECTRICAL TOYOTA ELECTRICAL WIRING DIAGRAM WORKBOOK. ASSIGNMENT Version 1.8 WORKSHEETS.

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

HEATER, AIR CONDITIONING AND VENTILATION

M V Intake Manifold INSTALLATION INSTRUCTIONS

A/C-HEATER SYSTEM - AUTOMATIC

AIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SCION FR-S PERFORMANCE AIR INTAKE Preparation 2.0L F-4

A/C refrigerant system, overview

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt

Turbocharger system components, servicing

ENGINE COOLING SYSTEM

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

PUSH BUTTON START INSTALLATION MANUAL

Air conditioning, electrical testing

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Your safety and the safety of others are very important.

CC145. Air Conditioning System. Operation Manual. CC145 Compact Cooler 4/2013 P.N A

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Air Conditioning System

HPC Radiator Fan Control Module with Sensor PN:

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

TSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS

Power Door Locks Cruise Control System. Cigarette Lighter. Blower. Fan. Windshield Wiper System. See Note. High Wiper. Med. Low.

Transcription:

1964 CHEVY IMPALA GEN IV w/o FACTORY AIR 561064 IMPALA 18865 GOLL ST. - SAN ANTONIO, TX. - 78266 ph.210-654-7171 - fax 210-654-3113 903061 REV A 7 /24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 1 OF 25

PAGES Table of Contents 1. COVER 2. TABLE OF CONTENTS 3. PACKING LIST / PARTS DISCLAIMER 4. INFORMATION PAGE 5. WIRING NOTICE 6. ENGINE COMPARTMENT FIGURE 1 7. CONDENSER ASSEMBLY, COMPRESSOR & BRACKET, PULLEYS, & PASSENGER COMPARTMENT FIGURES 2, 2a & 3 8. DEFROST DUCT INSTALLATION & FRESH AIR COVER INSTALLATION FIGURES 4 & 5 9. KICK PANEL INSTALLATION & FIREWALL COVER INSTALLATION FIGURES 6, 6a, 7 & 7a 10. EVAPORATOR INSTALLATION FIGURES 8 & 8a 11. EVAPORATOR INSTALLATION CONT. FIGURE 9 & 9a 12. FIREWALL CAP INSTALLATION & DRAIN HOSE INSTALLATION FIGURES 10,10a & 11 13. DRIVER SIDE UNDER DASH LOUVER INSTALLATION & CENTER/ PASSENGER SIDE UNDER DASH LOUVER INSTALLATION FIGURES 12,12a & 13 & 13a 14. LUBRICATING O-RINGS, A/C HOSE INSTALLATION, & MODIFIED A/C HOSE KIT FIGURE 14 15. HEATER HOSE & HEATER CONTROL VALVE INSTALLATION FIGURE 15 16. AC & HEATER HOSE ROUTING FIGURE 16 17. FINAL STEPS & GLOVE BOX INSTALLATION FIGURES 17,18 & 18a 18. CONTROL PANEL & DUCT HOSE ROUTING FIGURE 19 19. EVAPORATOR HARDLINE INSTALLATION FIGURE 20 20. WIRING DIAGRAM 21. GEN IV WIRING CONNECTION INSTRUCTIONS 22. OPERATION OF CONTROLS 23. TROUBLE SHOOTING INFORMATION 24. TROUBLE SHOOTING INFORMATION CONT. 25. EVAPORATOR KIT PACKING LIST 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 2 OF 25 2

EVAPORATOR KIT PACKING LIST No. QTY. PART No. DESCRIPTION 1. 2. 1 744004-VUE 1 784163 GEN IV 4 VENT EVAP. SUBCASE 1964 IMPALA w/o AC ACC. KIT EVAPORATOR KIT 561064 ** BEFORE BEGINNING INSTALLATION OPEN ALL PACKAGES AND CHECK CONTENTS OF SHIPMENT. PLEASE REPORT ANY SHORTAGES DIRECTLY TO VINTAGE AIR WITHIN 15 DAYS. AFTER 15 DAYS, VINTAGE AIR WILL NOT BE RESPONSIBLE FOR MISSING OR DAMAGED ITEMS. 1 2 GEN IV 4 VENT EVAP. SUB CASE 744004-VUE 3 ACCESSORY KIT 784163 NOTE: IMAGES MAY NOT DEPICT ACTUAL PARTS AND QUANTITIES. REFER TO PACKING LIST FOR ACTUAL PARTS AND QUANTITIES. 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 3 OF 25

IMPORTANT NOTICE-PLEASE READ FOR MAXIMUM SYSTEM PERFORMANCE VINTAGE AIR RECOMMENDS THE FOLLOWING: SAFETY SWITCHES: SERVICE INFO: 1964 IMPALA w/o AC GEN IV THIS KIT DOES NOT CONTAIN HEATER HOSE. YOU MUST PURCHASE 8 FEET OF 5/8 DIA. HEATER HOSE FROM VINTAGE AIR(31800-VUD) OR FROM YOU LOCAL PARTS RETAILER YOUR VINTAGE AIR SYSTEM IS EQUIPPED WITH A BINARY PRESSURE SAFETY SWITCH. A BINARY SWITCH (11078-VUS) DISENGAGES THE COMPRESSOR CLUTCH IN CASE OF EXTREME LOW PRESSURE CONDITION (REFRIGERANT LOSS) OR EXCESSIVELY HIGH HEAD PRESSURE (406 PSI), TO PREVENT COMPRESSOR DAMAGE OR HOSE RUPTURE. A TRINARY SWITCH (11076-VUS) COMBINES HI/LO PRESSURE PROTECTION WITH AN ELECTRIC FAN OPERATION SIGNAL AT 254 PSI., AND MAY BE SUBSTITUTED FOR USE WITH ELECTRIC CONDENSER FANS. COMPRESSOR SAFETY SWITCHES ARE EXTREMELY IMPORTANT SINCE AN A/C SYSTEM RELIES ON REFRIGERANT TO CARRY LUBRICATION THROUGH THE SYSTEM. ATTENTION: SYSTEM COMPONENTS: THE COMPRESSOR, EVAPORATOR, CONDENSER & DRIER ARE CAPPED. CAPS MAY BE UNDER PRESSURE WITH DRY NITROGEN; BE CAREFUL REMOVING CAPS. DO NOT REMOVE CAPS PRIOR TO INSTALLATION. REMOVING CAPS PRIOR TO INSTALLATION WILL CAUSE COMPONENTS TO COLLECT MOISTURE AND LEAD TO PREMATURE FAILURE AND UCED PERFORMANCE. EVACUATE THE SYSTEM FOR 35-45 MINUTES WITH SYSTEM COMPONENTS (DRIER, COMPRESSOR, EVAPORATOR AND CONDENSER) AT A TEMPERATURE OF AT LEAST 85 F. ON A COOL DAY THE COMPONENTS CAN BE HEATED WITH A HEAT GUN OR BY RUNNING THE ENGINE WITH THE HEATER ON BEFORE EVACUATING. LEAK CHECK AND CHARGE TO SPECIFICATIONS. VINTAGE AIR SYSTEMS ARE DESIGNED TO OPERATE WITH R134a or R-12 REFRIGERANT ONLY! USE OF ANY OTHER REFRIGERANTS RISKS A DANGER OF FIRE AND COULD DAMAGE EITHER YOUR AIR CONDITIONING SYSTEM OR YOUR VEHICLE. USE OF ANY OTHER REFRIGERANTS WILL VOID ALL WARRANTIES OF THE AIR CONDITIONING SYSTEM AND COMPONE NTS. USE OF THE PROPER TYPE AND AMOUNT OF REFRIGERANT IS CRITICAL TO PROPER SYSTEM OPERATION. VINTAGE AIR RECOMMENDS OUR SYSTEMS BE CHARGED BY WEIGHT WITH A QUALITY CHARGING STATION OR SCALE. REFRIGERANT CAPACITIES FOR VINTAGE AIR SYSTEMS (FOR OTHER SYSTEMS, CONSULT MANUFACTURER GUIDELINES) 134a SYSTEM CHARGE WITH 1.8 lbs. (1lbs. 12ozs) OF REFRIGERANT LUBRICANT CAPACITIES: R-12 SYSTEM CHARGE WITH 2.0 lbs. OF REFRIGERANT NEW COMPRESSOR - NO ADDITIONAL OIL NEEDED USED COMPRESSOR - CONSULT VINTAGE AIR 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 4 OF 25 4

IMPORTANT WIRING NOTICE-PLEASE READ SOME VEHICLES MAY HAVE HAD SOME OR ALL OF THEIR RADIO INTERFERENCE CAPACITORS REMOVED. THERE SHOULD BE A CAPACITOR FOUND AT EACH OF THE FOLLOWING LOCATIONS: 1. ON THE POSITIVE TERMINAL OF THE IGNITION COIL 2. IF THERE IS A GENERATOR, ON THE ARMATURE TERMINAL OF THE GENERATOR 3. IF THERE IS A GENERATOR, ON THE BATTERY TERMINAL OF THE VOLTAGE REGULATOR MOST ALTERNATORS HAVE A CAPACITOR INSTALLED INTERNALLY TO ELIMINATE WHAT IS CALLED 'WHINING' AS THE ENGINE IS REVVED. IF WHINING IS HEARD IN THE RADIO, OR JUST TO BE EXTRA CAUTIOUS, A RADIO INTERFERENCE CAPACITOR CAN BE ADDED TO THE BATTERY TERMINAL OF THE ALTERNATOR. IT IS ALSO IMPORTANT THAT THE BATTERY LEAD IS IN GOOD SHAPE AND THAT THE GROUND LEADS ARE NOT COMPROMISED. THERE SHOULD BE A HEAVY GROUND FROM THE BATTERY TO THE ENGINE BLOCK, AND ADDITIONAL GROUNDS TO THE BODY AND TO THE CHASSIS. IF THESE PRECAUTIONS ARE NOT OBSERVED, IT IS POSSIBLE FOR VOLTAGE SPIKES TO BE PRESENT ON THE BATTERY LEADS. THESE SPIKES COME FROM IGNITION SYSTEMS, CHARGING SYSTEMS, AND FROM TURNING SOME OF THE VEHICLE'S OTHER SYSTEMS ON AND OFF. MODERN COMPUTER OPERATED EQUIPMENT CAN BE SENSITIVE TO VOLTAGE SPIKES ON THEIR POWER LEADS, WHICH CAN CAUSE UNEXPECTED RESETS, STRANGE BEHAVIOR, AND MAY ALSO CAUSE PERMANENT DAMAGE. VINTAGE AIR STRIVES TO HARDEN THEIR PRODUCTS AGAINST THESE TYPES OF ELECTRICAL NOISE, BUT THERE IS A POINT WHERE A VEHICLE'S ELECTRICAL SYSTEM CAN BE DEGRADED SO MUCH THAT NOTHING CAN HELP. RADIO INTERFERENCE CAPACITORS SHOULD BE AVAILABLE AT MOST AUTO & TRUCK PARTS SUPPLIERS. THEY TYPICALLY ARE CYLINDRICAL IN SHAPE, A LITTLE OVER AN INCH LONG, A LITTLE OVER A HALF INCH IN DIAMETER, THEY HAVE A SINGLE LEAD COMING FROM ONE END OF THE CYLINDER WITH A TERMINAL ON THE END OF THE WIRE, AND THEY WILL HAVE A MOUNTING CLIP WHICH IS SCREWED INTO A GOOD GROUND ON THE VEHICLE. THE SPECIFIC VALUE OF THE CAPACITANCE IS NOT TOO SIGNIFICANT, IN COMPARISON TO IGNITION CAPACITORS THAT ARE MATCHED WITH THE COIL TO UCE PITTING OF THE POINTS. CARE MUST BE TAKEN WHEN INSTALLING THE COMPRESSOR LEAD, NOT TO SHORT IT TO GROUND. THE COMPRESSOR LEAD MUST NOT BE CONNECTED TO A CONDENSER FAN OR ANY OTHER AUXILIARY DEVICE. SHORTING TO GROUND OR CONNECTING TO A CONDENSER FAN OR ANY OTHER AUXILIARY DEVICE WILL CAUSE SEVERE DAMAGE TO THE ECU. WHEN INSTALLING GROUND LEADS ON G EN IV SYSTEMS, THE BLOWER CONTROL GROUND AND ECU GROUND MUST BE CONNECTED DIRECTLY TO THE NEGATIVE BATTERY POST. THE HEATER CONTROL VALVE IS A NORMALLY OPEN VALVE. IT MUST BE CONNECTED TO THE ECU TO BLOCK WATER FLOW IN AC MODE. 5 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 5 OF 25

ENGINE COMPARTMENT INSTALLATION INSTRUCTIONS FOR 1964 IMPALA w/o AC BEFORE STARTING THE AIR CONDITIONER INSTALLATION, CHECK FOR PROPER OPERATION OF ALL COMPONENTS (RADIO, LIGHTS, WIPERS, ETC.). STUDY THE INSTRUCTIONS, ILLUSTRATIONS AND DIAGRAMS. FOR EASE OF INSTALLATION CHECK OFF ( ) EACH PROCEDURE PRIOR TO MOVING ON TO THE NEXT STEP. DISCONNECT BATTERY AND REMOVE DRAIN RADIATOR REMOVE O.E.M. HEATER/ BLOWER ASSEMBLY (DISCARD) SEE FIGURE 1 TO REMOVE OEM HEATER/ BLOWER ASSEMBLY. THE FACTORY MANUAL INDICATES DOING THE FOLLOWING, REMOVE RIGHT INNER FENDER. O.E.M. HEATER/BLOWER ASSEMBLY RIGHT INNER FENDER FIGURE 1 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 6 OF 25 6

CONDENSER ASSEMBLY & INSTALLATION REFER TO SEPARATE INSTRUCTIONS INCLUDED WITH THE CONDENSER KIT TO INSTALL THE CONDENSER. BINARY SWITCH INSTALLATION (REFER TO CONDENSER INSTRUCTIONS) COMPRESSOR & BRACKETS REFER TO SEPARATE INSTRUCTIONS INCLUDED WITH THE BRACKET KIT TO INSTALL THE COMPRESSOR BRACKET. PULLEYS IN MOST INSTANCES THE BELT LENGTHS WILL REMAIN THE SAME. PASSENGER COMPARTMENT REMOVE INSTRUMENT PANEL, SEE FIGURE 2 BELOW. REMOVE THE OEM CONTROL PANEL ASM. SEE FIGURE 2 BELOW REMOVE GLOVE BOX DOOR REMOVE GLOVE BOX (DISCARD) REMOVE RADIO,SPEAKER (RETAIN) REMOVE O.E.M HEATER ASSMEBLY SEE FIGURE 2a BELOW. REMOVE O.E.M DEFROST DUCT ASSEMBLY, SEE FIGURE 2a & 3 BELOW. (REMOVE SPOT WELDS ON DEF DUCT BY CHISEL OR DIE GRINDER. SEE FIGURE 3 BELOW.) SPEAKER INSTRUMENT PANEL O.E.M. DEF DUCT ASSEMBLY O.E.M. CONTROL PANEL RADIO FIGURE 2 GLOVE BOX DOOR DASH SUPPORT 7 903061 FIGURE 2a O.E.M. HEATER ASSEMBLY INNER COWL USE A CHISEL OR DIE GRINDER TO BREAK SPOT-WELDS REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 7 OF 25 FIGURE 3 DEFROST DUCT ASSEMBLY

DEFROST DUCT INSTALLATION PLACE DEFROST DUCT UNDER DASH, ALIGN WITH O.E.M. DEFROST OPENING IN DASH. DRILL (2) 1/8 HOLES IN COWL USING DEFROST DUCT HOLE AS TEMPLATE. SECURE USING (2) #10 x 1/2 SHEET METAL SCREWS AS SHOWN BELOW IN FIGURE 4. (2) #10 X 1/2 SHEET METAL SCREWS FRESH AIR COVER INSTALLATION FIGURE 4 APPLY A 1/4 BEAD OF SILICONE AROUND THE BACK SIDE OF THE FRESH AIR CAP AS SHOWN IN FIGURE 5, BELOW. ATTACH FRESH AIR CAP TO FIREWALL USING A 1/4-20 x 1" BOLT AND WASHER, SEE FIGURE 5, BELOW. 1/4-20 x 1 BOLT w/ WASHER FRESH AIR CAP BACK SIDE OF FRESH AIR CAP SILICONE OEM HEATER HOLES FIGURE 5 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 8 OF 25 8

KICK PANEL INSTALLATION REMOVE THE PASSENGER SIDE KICK PANEL BY REMOVING THE (2) #10 x 1 PH PAN HEAD SCREWS, DISCONNECT THE FRESH AIR CABLE FROM DOOR AND DISCARD CABLE ASSEMBLY. CLOSE FRESH AIR DOOR ASSEMBLY IN KICK PANEL AND SEAL DOOR w/ 1/4 BEAD OF SILICONE AROUND DOOR AS SHOWN IN FIGURE 6. FRESH AIR DOOR 1/4 BEAD OF SILICONE #10 x 1 PH PAN HEAD SCREWS PASSENGER SIDE KICK PANEL INSTALL PASSENGER SIDE KICK PANEL USING THE (2) OEM SCREWS AS SHOWN IN FIGURE 6a. FIGURE 6 FIGURE 6a FIREWALL COVER INSTALLATION INSTALL GROMMET ON FIREWALL COVER AS SHOWN IN FIGURE 7. APPLY A 1/4 BEAD OF SILICONE AROUND THE FIREWALL COVER AS SHOWN IN FIGURE 7a. FROM INSIDE THE CAR, INSTALL FIREWALL COVER ON FIREWALL SEE FIGURE 7. FROM THE ENGINE COMPARTMENT SECURE FIREWALL COVER TO FIREWALL USING (3) 1/4-20 x 1 HEX BOLTS WITH WASHERS AND 1/4-20 COARSE NUT w/ STARWASHER. SEE FIGURE 7. 643166 FIREWALL COVER (3) 1/4-20 x 1 HEX BOLTS w/ FLAT WASHERS VIEW SHOWN FROM INSIDE CAR. SILICONE FIGURE 7a ENGINE SIDE OF FIREWALL COVER 33144-VUI GROMMET 7/8 OD x 3/8 ID (3) 1/4-20 COARSE NUT w/ STARWASHER 9 903061 FIGURE 7 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 9 OF 25

EVAPORATOR INSTALLATION ON A WORK BENCH INSTALL (2) HEATER LINE WITH PROPERLY LUBRICATED O-RINGS. (SEE FIGURE 13 PAGE 14, AND FIGURE 19 PAGE 19.) INSTALL (2) 1/4-20 x 1 HEX BOLT AND 1/4 PUSH-ON NUT ON EVAP REAR BRKT AS SHOWN IN FIGURE 8a BELOW. INSTALL EVAPORATOR FRONT & REAR MOUNTING BRACKETS ON EVAPORATOR USING (6)1/4-20 x 1/2 HEX BOLTS AND TIGHTEN AS SHOWN IN FIGURE 8 & 8a BELOW. INSTALL (2) A/C HARDLINES WITH PROPERLY LUBRICATED O-RINGS. (SEE FIGURE 13 PAGE 14, AND FIGURE 19 PAGE 19.) (2) 18290-VUB 1/4-20 x 1 HEX BOLT EVAP FRONT BRKT 643163 18287-VUB (2)1/4-20 x ½ HEX BOLT FIGURE 8 189125-MUR 1/4 PUSH NUT BOLT RETAINER 18287-VUB (2) 1/4-20 x ½ HEX BOLT EVAP REAR BRKT 643164 FIGURE 8a 18287-VUB (2) 1/4-20 x ½ HEX BOLT 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 10 OF 25 10

EVAPORATOR INSTALLATION CONT. LIFT EVAPORATOR UNIT UP UNDER THE DASHBOARD SEE FIGURE 9. SECURE LOOSELY TO THE FIREWALL FROM THE ENGINE COMPARTMENT SIDE USING (2) 1/4-20 NUTS w/ STAR WASHER AND FLAT WASHERS, SEE FIGURE 9. USING OEM SCREW SECURE THE FRONT EVAPORATOR MOUNTING BRACKET TO OEM SPEAKER MOUNTING BRKT. SEE FIGURE 9 AND 9a. VERIFY THAT EVAPORATOR UNIT IS LEVEL AND SQUARE TO THE DASH, THEN TIGHTEN ALL MOUNTING BOLTS. (NOTE: TIGHTEN THE BOLT ON FIREWALL FIRST, THEN THE FRONT MOUNTING BRACKET SCREWS.) OEM FASTNER EVAPORATOR BRACKET MOUNTING HOLES SPEAKER BRKT OEM SCREW EVAP FRONT BRKT FIGURE 9a FIGURE 9 11 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 11 OF 25

FIREWALL CAP INSTALLATION INSTALL GROMMETS ON FIREWALL CAP AS SHOWN IN FIGURE 10 BELOW. APPLY A 1/4 BEAD OF SILICONE AROUND THE BACK SIDE OF THE FIREWALL CAP AS SHOWN IN FIGURE 10a BELOW. PASS LINES THROUGH FIREWALL CAP, AND SECURE WITH (3) #10 x 1/2 SHEET METAL SCREWS. SEE FIGURE 10 BELOW. SILICONE 643167 FIREWALL CAP FIGURE 10a 33135-VUI DRAIN HOSE INSTALLATION 33137-VUI FIGURE 10 (3) 18247-VUB #10 x 1/2 SHEET METAL SCREWS LOCATE EVAPORATOR DRAIN ON BOTTOM OF EVAPORATOR CASE. IN-LINE WITH DRAIN, LIGHTLY MAKE A MARK ON THE FIREWALL MEASURE 1 DOWN AND 2 1/2 TO THE LEFT AND DRILL A 5/8 HOLE THROUGH THE FIREWALL. SEE FIGURE 11 BELOW. INSTALL DRAIN HOSE TO BOTTOM OF EVAPORATOR UNIT AND ROUTE THROUGH FIREWALL. SEE FIGURE 11 BELOW. 1 DRAIN HOSE 2 1/2 1 EVAPORATOR CASE FIGURE 11 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 12 OF 25 12

DRIVER SIDE UNDER DASH LOUVER INSTALLATION ALIGN LOUVER BEZEL UNDER DASH AND USE LOUVER BEZEL HOUSING AS YOUR GUIDE TO MARK AND DRILL (2) 3/16 HOLES UNDER DASH. SEE FIGURE 12 BELOW. PLACE LOUVER BEZEL UNDER DASH AND ALIGN TO DASH. SECURE LOUVER BEZEL UNDER DASH USING (2) 10/32 x 1/2 PAN HEAD SCREW w/ 10/32 NUT w/ STAR WASHER INSTALL LOUVER IN UNDER DASH BEZEL AS SHOWN IN FIGURE 12a BELOW. FIGURE 12 CENTER/PASSENGER SIDE UNDER DASH LOUVER INSTALLATION FIGURE 12a (2) 10/32 x 1/2 PAN HEAD SCREWS w/nut w/ STAR WASHER 49157-VUL LOUVERS PLACE LOUVER BEZEL UNDER DASH AND ALIGN WITH O.E.M. HOLE IN PASSENGER SIDE DASH SEE FIGURE 13 BELOW. ALIGN LOUVER BEZEL UNDER DASH AND USE LOUVER BEZEL HOUSING AS YOUR GUIDE TO MARK AND DRILL (2) 3/16 HOLES UNDER DASH. SECURE LOUVER BEZEL UNDER DASH USING (3) 10/32 x 1/2 PAN HEAD SCREW w/ 10/32 NUTS w/ STAR WASHER SEE FIGURE 13 BELOW. INSTALL LOUVER IN UNDER DASH BEZEL AS SHOWN IN FIGURE 13a BELOW. OEM HOLE (3) LOUVERS 49157-VUL FIGURE 13a FIGURE 13 (3) 10/32 x 1/2 PAN HEAD SCREWS w/ NUT w/star WASHER 13 903061 FINAL ASSEMBLY REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 13 OF 25

LUBRICATING O-RINGS O-RING MALE INSERT FEMALE NUT FOR A PROPER SEAL OF FITTINGS: INSTALL SUPPLIED O-RINGS AS SHOWN AND LUBRICATE WITH SUPPLIED OIL. #6 O-RING O-RING SUPPLIED OIL FOR O-RINGS O-RING,INSTALES OVER MALE INSERT TO SWAGED LIP #8 O-RING #10 O-RING FIGURE 14 HOLD WITH THIS WRENCH TWIST WITH THIS WRENCH A/C HOSE INSTALLATION STANDARD HOSE KIT LOCATE THE #8 COMPRESSOR A/C HOSE. LUBRICATE (2) #8 O-RINGS (SEE FIGURE 14, ABOVE) AND CONNECT THE 135 FEMALE FITTING w/134a SERVICE PORT TO THE #8 DISCHARGE PORT ON THE COMPRESSOR. ROUTE THE STRAIGHT FEMALE FITTING TO THE #8 CONDENSER HARDLINE COMING THROUGH CORE SUPPORT. SEE FIGURE 16, PAGE 16. TIGHTEN EACH FITTING CONNECTION AS SHOWN IN FIGURE 14 ABOVE. LOCATE THE #10 COMPRESSOR A/C HOSE. LUBRICATE (2) #10 O-RINGS (SEE FIGURE 14, ABOVE) AND CONNECT THE #10 135 FEMALE FITTING w/134a SERVICE PORT TO THE #10 SUCTION PORT ON THE COMPRESSOR. ROUTE THE 45 FEMALE FITTING TO THE #10 EVAPORATOR HARDLINE COMING THROUGH THE FIREWALL SEE FIGURE 16, PAGE 16. TIGHTEN EACH FITTING CONNECTION AS SHOWN IN 14 ABOVE. (NOTE: WRAP THE #10 FITTING CONNECTIONS WITH PRESS TAPE. SEE FIGURE 15, PAGE 15. LOCATE THE #6 EVAP/CORE HARDLINE AND LUBRICATE (2) #6 O-RINGS (SEE FIGURE 14, ABOVE) AND CONNECT THE HARDLINE TO THE #6 HARDLINE COMING THROUGH THE CORE SUPPORT FROM DRIER. ATTACH THE OTHER END OF THE HARDLINE WITH LUBRICATED O-RING TO THE #6 EVAPORATOR HARDLINE COMING THROUGH THE FIREWALL. SEE FIGURE 16, PAGE 16. TIGHTEN EACH FITTING CONNECTION AS SHOWN IN FIGURE 14, ABOVE. USE A #2 & #10 ADEL CLAMP TO SECURE THE #6 EVAP/ CORE HARDLINE AND THE 5/8 HEATER HOSE TO THE INNER FENDERWELL AS SHOWN IN FIGURE 16, PAGE 16. SECURE THE ADEL CLAMP TO THE INNER FENDER USING (2)10-32 x ½ PH PAN HEAD SCREWS w/ NUTS. MODIFIED A/C HOSE KIT REFER TO SEPARATE INSTRUCTIONS INCLUDED WITH MODIFIED HOSE KIT. 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 14 OF 25 14

HEATER HOSE & HEATER CONTROL VALVE INSTALLATION NOTE: VINTAGE AIR SYSTEMS REQUIRE (2) 5/8 HOSE NIPPLES (NOT SUPPLIED). ONE FOR THE INTAKE (PRESSURE) AND ONE FOR THE WATER PUMP (SUCTION) - IF REQUI REMOVE EXISTING HOSE NIPPLE OR NIPPLES AND INSTALL NEW 5/8 HOSE NIPPLES IN INTAKE AND WATER PUMP. ROUTE A PIECE OF HEATER HOSE FROM THE WATER PUMP TO THE HEATER LINE COMING THROUGH THE FIREWALL AS SHOWN IN FIGURE 15, BELOW. SECURE USING HOSE CLAMPS. ROUTE A PIECE OF HEATER HOSE FROM THE INTAKE TO THE HEATER LINE COMING THROUGH THE FIREWALL AS SHOWN IN FIGURE 15, BELOW. NOTE: INSTALL HEATER CONTROL VALVE IN-LINE WITH INTAKE MANIFOLD (PRESSURE SIDE) HEATER HOSE, SECURE USING HOSE CLAMPS AS SHOWN IN FIGURE 15, BELOW. NOTE PROPER FLOW DIRECTION. NOTE: HEATER CONTROL VALVE WILL GET HOT TO THE TOUCH WHEN ENERGIZED ECU MODULE PRESS TAPE FLOW HEATER HOSE FROM HTR CNTRL VLV #10 SUCTION LINE (INSULATED) 091671 EXPANSION VALVE O-RING #10 SUCTION HOSE 096059 #6 LIQUID LINE 091061 TO WATER PUMP FROM INTAKE PRESS TAPE FIGURE 15 15 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 15 OF 25

EVAPORATOR SUB CASE PRESS TAPE ECU MODULE #10 A/C SUCTION HOSE (COMP-EVAP) 096059 FIREWALL COVER 643166 O RING #8 A/C DISCHARGE HOSE (COMP-COND HARDLINE) 096062 #6 HARDLINE DRIER/ CONDENSER 35056-LCG COMPRESSOR SAFETY SWITCH (BINARY TYPE SCREW ON DRIER) (REFER TO CONDENSER INST.) 1964 IMPALA w/o AC #6 EVAP/CORE HARDLINE 091061 HEATER CONTROL VALVE 46115-VUH 10-32 x ½ PH PAN HEAD SCREW w/ NUT INNER FENDER #6 HARDLINE #2 ADEL CLAMP 31600-VUD AC & HEATER HOSE ROUTING NOTE: VINTAGE AIR SYSTEMS REQUIRE (2) 5/8 HOSE NIPPLES, ONE LOCATED IN INTAKE AND ONE LOCATED IN WATER PUMP (NOT SUPPLIED) #8 CONDENSER HARDLINE 091064 #6 DRIER/CORE HARDLINE 091057 INNER FENDER FIGURE 16 10-32 x ½ PH PAN HEAD SCREW w/ NUT #10 SUCTION LINE (INSULATED) 091671 HEATER HOSE EXPANSION VALVE #10 ADEL CLAMP 31601-VUD 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 16 OF 25 16

FINAL STEPS INSTALL DUCT HOSES AS SHOWN IN FIGURE 19, PAGE 18. ROUTE A/C WIRES THROUGH 5/8 GROMMET AS SHOWN ON FIGURE 16 ( 12 VOLT/ GROUND/ BINARY SWITCH/ HEATER VALVE) INSTALL CONTROL PANEL ASM. PLUG THE CONTROL PANEL HARNESS INTO THE ECU MODULE ON SUB CASE AS SHOWN IN PAGE 18. PLUG THE WIRING HARNESS INTO THE ECU MODULE ON SUB CASE AS SHOWN IN FIGURE 19, PAGE 18. (WIRE ACCORDING TO WIRING DIAGRAM ON PAGE 20 & 21.) NOTE: CONTROL PANEL MUST BE CALIBRATED. (REFER TO CONTROL PANEL INSTRUCTIONS FOR CALIBRATION PROCEDURES. GLOVE BOX INSTALLATION ( SEE FIGURE 18) REINSTALL ALL PREVIOUSLY REMOVED ITEMS (BATTERY RADIO, SPEAKER, INSTRUMENT PANEL). FILL RADIATOR WITH AT LEAST A 50/50 MIXTURE OF APPROVED ANTIFREEZE AND DISTILLED WATER. IT IS THE OWNERS RESPONSIBILITY TO KEEP THE FREEZE PROTECTION AT THE PROPER LEVEL FOR THE CLIMATE IN WHICH THE VEHICLE IS OPERATED. FAILURE TO FOLLOW ANTIFREEZE RECOMMENDATIONS WILL CAUSE HEATER CORE TO CORRODE PREMATURELY AND POSSIBLY BURST IN AC MODE AND/OR FREEZING WEATHER, VOIDING YOUR WARRANTY. DOUBLE CHECK ALL FITTINGS, BRACKETS AND BELTS FOR TIGHTNESS. VINTAGE AIR RECOMMENDS THAT ALL AC SYSTEMS BE SERVICED BY A CERTIFIED AUTOMOTIVE AIR CONDITIONING TECHNICIAN. EVACUATE THE SYSTEM FOR A MINIMUM OF 45 MINUTES PRIOR TO CHARGING AND LEAK CHECK PRIOR TO SERVICING. CHARGE THE SYSTEM TO THE CAPACITIES STATED ON THE INFORMATION PAGE (PAGE 4) OF THIS INSTRUCTION MANUEL. FIREWALL CAP FIREWALL COVER GROMMET GLOVE BOX INSTALLATION FIGURE 17 THE NEW GLOVE BOX IS MADE IN TWO (2) PIECES FOR EASY INSTALLATION. INSERT BOTTOM HALF OF NEW GLOVE BOX, INTO GLOVE BOX OPENING AND POSITION IN PLACE. INSERT TOP HALF OF GLOVE BOX AND FASTEN TO BOTTOM HALF USING (4) #6 x 3/8" BLACK PAN HEAD PHILLIPS SCREWS (SEE FIGURE 18, BELOW). INSTALL GLOVE BOX DOOR USING (3) OEM SCREWS THROUGH THE TINNERMAN NUTS. INSTALL GLOVE BOX USING (2) OEM SCREWS SEE FIGURE 18a. GLOVE BOX TOP 624163 OEM SCREWS TINNERMAN NUTS FIGURE 18 17 903061 (4)#6 x 3/8 PH PAN HEAD SCREWS GLOVE BOX BOTTOM 624164 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 17 OF 25 FIGURE 18a OEM SCREWS

CONTROL PANEL & DUCT HOSE ROUTING PASSENGER SIDE LOUVER 2 ½ x 38 PLUG FROM CONTROL WIRING HARNESS 232006-VUR DRIVER SIDE DEF. DUCT 2 x 15 PLUG FROM WIRING HARNESS 232001-VUR DRIVER SIDE LOUVER 2 1/2 x 38 FIGURE 19 PASSENGER SIDE LOUVER DRIVER SIDE LOUVER 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 18 OF 25 CENTER LOUVER DRIVER SIDE 2 ½ x 12 CENTER LOUVER PASSENGER SIDE PASS. SIDE DEF. DUCT 2 x 15 CENTER LOUVER PASS. SIDE 2 ½ x 16 CENTER LOUVER DRIVER SIDE 18

FIGURE 20 1964 IMPALA w/o AC #10 O-RING 33859-VUF #6 LIQUID LINE 091078 ECU MODULE EVAPORATOR HARD LINE INSTALLATION PRESS TAPE #10 O-RING (33859-VUF) #10 SUCTION LINE (091671) #6 O-RING (33857-VUF) HEATER LINE (EVAP TO INTAKE) 091661 HEATER LINE (EVAP TO WATER PUMP) 091661 19 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 19 OF 25

WIRING DIAGRAM JF8 VIEWED FROM WIRE SIDE /BLU / /YEL /GRN PRGM N/A TACH DASH LAMP (NOT USED) NA COLD HOT DASH FLR DEF FAN GRY YEL/BLK TAN VIO ORA VIEWED FROM BOARD TOP SIDE OPTIONAL: WIDE OPEN THROTTLE SWITCH CONTACTS CLOSE ONLY AT FULL THROTTLE, WHICH DISABLES AC COMPRESSOR LT BLU GRN GRY JM3 JM4 JM5 JM6 GRN YEL BLU GRN BLK NOT USED GRN YEL BLU GRN BLK GRN YEL BLU GRN BLK STEPPER DASH/FLOOR STEPPER DEFROST/PLENUM STEPPER TEMPERTURE BLEND WIDE OPEN THROTTLE SWITCH (OPTIONAL) JF8 JM9 JM8 JM2 JM1 BLK BLK VIO RUN BAT IGNITION SWITCH + 12v GENIV WIRING DIAGRAM REVISION B, 2006-05-04 GEN-IV ECU EVAPORATOR TEMPERATURE SENSOR BAT-POS BAT-NEG BLWR-POS BLWR-NEG ORA GRY POS NEG CIRCUIT BREAKER 30 AMP COMPRESSOR RELAY 30 30 85 87 86 85 87 86 DK BLU GRN BSC SHLD HEATER CONTROL VALVE RELAY PWM SHLD BLK YEL BLK DK BLU BLOWER MOTOR WARNING: ALWAYS MOUNT CIRCUIT BREAKER UNDER THE HOOD IN THE ENGINE COMPARTMENT AND AS CLOSE TO THE BATTERY AS POSSIBLE. DRIER BINARY OR TRINARY SAFETY SWITCH HCV BATTERY CMPR = CHASSIS NOTE: GROUND 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 20 OF 25 20

BACK SIDE OF EVAPORATOR NOTE: MOUNT RELAYS IN DESI LOCATION UNDER DASH CONNECT HEATER CONTROL VALVE RELAY HEATER CONTROL VALVE CONNECT (SUPPLIED GROUND WIRE, NOT PART OF HARNESS) CIRCUIT BREAKER 30 AMP CONNECT CONNECT GEN IV WIRING CONNECTION INSTRUCTIONS REFER TO CONTROL PANEL INSTRUCTIONS AND PLUG IN ACCORDINGLY CONTROL WIRING HARNESS CONNECT WIRING HARNESS FRONT SIDE OF EVAPORATOR NOTE: YELLOW, ORANGE & TAN COMING FROM HARNESS ARE NOT USED. GRAY WIRE IS USED FOR PROGRAMING CONTROLS IF APPLICABLE VIOLET A/C COMPRESSOR RELAY CHASSIS GROUND + CONNECT CONNECT (IGNITION HOT TERMINAL) + 12 V BLACK BLUE RUN BAT IGNITION SWITCH COMPRESSOR BINARY SAFETY SWITCH CONNECT - NOTE: CONNECT WHITE WIRES DIRECTLY TO ( ) BATTERY TERMINAL NOTE: IF USING TRINARY SAFETY SWITCH- REFER TO WIRING SCHEMATIC SUPPLIED WITH TRINAY SAFETY SWITCH FOR PROPER WIRING INSTRUCTIONS BATTERY BLUE GRN WARNING: ALWAYS MOUNT CIRCUIT BREAKER UNDER THE HOOD IN THE ENGINE COMPARTMENT AND AS CLOSE TO THE BATTERY AS POSSIBLE. 21 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 21 OF 25

OPERATION OF CONTROLS NOTE: CONTROLS MUST BE CALIBRATED PRIOR TO FIRST OPERATION- REFER TO CONTROL PANEL INSTRUCTIONS NOTE: WHEN BATTERY POWER IS FIRST CONNECTED TO THE ECU, THE COMPUTER GOES THROUGH AN INITIALIZATION SEQUENCE. THIS INITIALIZATION MAY TAKE UP TO 30 SECONDS. DURING INITIALIZATION THE BLOWER WILL NOT OPERATE, BUT THE DOORS INSIDE THE UNIT WILL BE OPERATING. A LOW BATTERY OR DISCONNECTING THE BATTERY MAY ALSO TRIGGER A RE-INITIALIZATION. DURING START UP, A LOW BATTERY MAY DROP BELOW 7 VOLTS, TRIGGERING RE-INITIALIZATION. FAN MODE TEMP BLOWER SPEED THIS LEVER CONTROLS THE BLOWER SPEED, FROM OFF TO HI MODE LEVER THIS LEVER CONTROLS THE MODE POSITIONS FROM DASH TO FLOOR TO DEFROST THERMOSTAT LEVER THIS LEVER CONTROLS THE TEMPERATURE FROM HOT TO COLD BLOWER SPEED MODE LEVER FAN MODE TEMP SYSTEM OFF THERMOSTAT LEVER BLOWER SPEED SLIDE THE FAN LEVER UP OR DOWN TO SELECT DESIRE FAN SPEED (SLIDE LEVER ALL THE WAY DOWN FOR MAXIMUM FAN SPEED) MODE LEVER SLIDE THE MODE LEVER ALL THE WAY UP FOR DASH MODE THERMOSTAT LEVER IN A/C MODE SLIDE THE TEMP LEVER ALL THE WAY UP TO ENGAGE COMPRESSOR FOR MAXIMUM COOLING. (SLIDE LEVER UP OR DOWN TO ADJUST DESI TEMPERATURE) FAN MODE TEMP A/C MODE BLOWER SPEED SLIDE THE FAN LEVER UP OR DOWN TO SELECT DESIRE FAN SPEED (SLIDE LEVER ALL THE WAY DOWN FOR MAXIMUM FAN SPEED) FAN MODE TEMP BLOWER SPEED SLIDE THE FAN LEVER UP OR DOWN TO SELECT DESIRE FAN SPEED (SLIDE LEVER ALL THE WAY DOWN FOR MAXIMUM FAN SPEED) FAN MODE TEMP MODE LEVER SLIDE THE MODE LEVER TO THE CENTER FOR FLOOR MODE (SLIDE LEVER UP OR DOWN TO BLEND BETWEEN DESI MODE POSITIONS) MODE LEVER SLIDE THE MODE LEVER ALL THE WAY DOWN FOR DEFROST MODE (SLIDE LEVER UP OR DOWN TO BLEND BETWEEN DESI MODE POSITIONS) THERMOSTAT LEVER IN HEAT MODE SLIDE THE TEMP LEVER ALL THE WAY DOWN FOR MAXIMUM HEATING. (SLIDE LEVER UP OR DOWN TO ADJUST DESI TEMPERATURE) HEAT MODE THERMOSTAT LEVER IN DEF MODE SLIDE THE TEMP LEVER ALL THE WAY UP TO ENGAGE COMPRESSOR FOR MAXIMUM COOLING. (SLIDE LEVER UP OR DOWN TO ADJUST DESI TEMPERATURE) DEFROST MODE 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 22 OF 25 22

23 TROUBLE SHOOTING INFORMATION SYMPTOM CONDITION CHECKS ACTIONS NOTES VERIFY ALL PINS ARE INSERTED INTO PLUG. INSURE NO PINS ARE BENT OR DAMAGED IN ECU. VERIFY CONTINUITY TO CHASSIS GROUND WITH WHITE CONTROL HEAD WIRE AT VARIOUS POINTS. NO OTHER FUNCTIONS WORK CHECK FOR DAMAGED PINS OR WIRES IN CONTROL HEAD PLUG. 1. BLOWER STAYS ON HIGH SPEED WHEN IGNITION IS ON LOSS OF GROUND ON THIS WIRE WILL RENDER CONTROL HEAD INOPERABLE CHECK FOR DAMAGED GROUND WIRE (WHITE) IN CONTROL HEAD HARNESS. SEE BLOWER SWITCH CHECK PROCEDURE ALL OTHER FUNCTIONS WORK CHECK FOR DAMAGED BLOWER SWITCH OR POT AND ASSOCIATED WIRING. BE SURE SMALL, 20GA. WHITE GROUND WIRE IS CONNECTED TO THE BATTERY GROUND POST. IF IT IS, REPLACE ECU. UN-PLUG 3 WIRE BSC CONTROL CONNECTOR FROM ECU. IF BLOWER SHUTS OFF, ECU IS EITHER IMPROPERLY WI, OR DAMAGED. BLOWER STAYS ON HIGH SPEED WHEN IGNITION IS ON OR OFF. CHECK TO INSURE THAT NO BSC WIRING IS DAMAGED OR SHORTED TO VEHICLE GROUND. THE BSC OPERATES THE BLOWER BY GROUND SIDE PWM SWITCHING. THE POSITIVE WIRE TO THE BLOWER WILL ALWAYS BE HOT. IF THE "GROUND" SIDE OF THE BLOWER IS SHORTED TO CHASSIS GROUND, THE BLOWER WILL RUN ON HI. UN-PLUG 3 WIRE BSC CONTROL CONNECTOR FROM ECU. IF BLOWER STAYS RUNNING, THE BSC IS EITHER IMPROPERLY WI, OR DAMAGED. NO OTHER PART REPLACEMENTS SHOULD BE NECESSARY. REPLACE BSC. (THIS WILL REQUIRE EVAPORATOR TO BE REMOVED FROM VEHICLE. ) CHARGE SYSTEM OR BYPASS PRESSURE SWITCH. DANGER- NEVER BYPASS SAFETY SWITCH WITH ENGINE RUNNING, SERIOUS INJURY CAN RESULT SYSTEM IS NOT CHARGED SYSTEM MUST BE CHARGED FOR COMP. TO ENGAGE. 2. COMPRESSOR WILL NOT TURN ON (ALL OTHER FUNCTIONS WORK) TO CHECK FOR PROPER POT FUNCTION, CHECK VOLTAGE AT WHITE/BLUE WIRE. VOLTAGE SHOULD BE BETWEEN 0 AND 5V, AND WILL VARY CHECK CONTINUITY TO GROUND ON WHITE CONTROL HEAD WIRE. CHECK FOR 5V ON CONTROL HEAD WIRE. 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 23 OF 25 CHECK FOR FAULTY A/C POT OR ASSOC. WIRING (NOT APPLICABLE TO 3 POT CONTROLS) WITH POT LEVER POSITION. DISCONNECTED OR FAULTY THERMISTOR WILL CAUSE COMPRESSOR TO BE DISABLED. CHECK TWO PIN CONNECTOR AT ECU HOUSING. CHECK FOR DISCONNECTED OR FAULTY THERMISTOR. CHECK FOR FAULTY A/C POT OR ASSOC. WIRING REPAIR/REPLACE POT/CONTROL WIRING WIRE @ A/C POT SHOULD HAVE APPROX. 5V WITH IGNITION ON. WHITE WIRE WILL HAVE CONTINUITY TO CHASSIS GROUND, WHITE/BLUE WIRE SHOULD VARY BETWEEN 0V AND 5V WHEN LEVER IS MOVED UP AND DOWN. CHECK FOR FAULTY A/C RELAY REPLACE RELAY 3. COMPRESSOR WILL NOT TURN OFF (ALL OTHER FUNCTIONS WORK)

TROUBLE SHOOTING INFORMATION CONT. 1964 IMPALA w/o AC WORKS WHEN ENGINE IS NOT RUNNING, SHUTS OFF WHEN ENGINE IS STARTED. (TYPICALLY EARLY GEN 4, BUT POSSIBLE ON ALL VERSIONS) NOISE INTERFERENCE FROM EITHER IGNITION OR ALTERNATOR. INSTALL CAPACITORS ON IGN. COIL, AND ALTERNATOR. ENSURE GOOD GROUND AT ALL POINTS.RE-LOCATE COIL AND ASSOCIATED WIRING AWAY FROM ECU AND ECU WIRING. CHECK FOR BURNED OR LOOSE PLUG WIRES. 4. SYSTEM WILL NOT TURN ON OR RUNS INTERMITTENTLY IGNITION NOISE (RADIATED OR CONDUCTED) WILL CAUSE THE SYSTEM TO SHUT DOWN DUE TO HIGH VOLTAGE SPIKES. IF THIS IS SUSPECTED, CHECK WITH A QUALITY OSCILISCOPE. SPIKES GREATER THAN 16V WILL SHUT DOWN ECU. INSTALL A RADIO CAPACITOR AT THE POSITIVE POST OF THE IGNITION COIL (SEE RADIO CAPACITOR INSTALLATION BULLETEN). A FAULTY ALTERNATOR OR WORN OUT BATTERY CAN ALSO RESULT IN THIS CONDITION. BATTERY MUST BE IN GOOD CONDITION FOR ALTERNATOR REGULATOR TO FUNCTION PROPERLY. WILL NOT TURN ON UNDER ANY CONDITIONS VERIFY CONNECTIONS ON POWER LEAD, IGNITION LEAD, AND BOTH WHITE GROUND WIRES. VERIFY BATTERY VOLTAGE IS GREATER THAN 10 VOLTS AND LESS THAN 16. 5. LOSS OF MODE DOOR FUNCTION CHECK FOR POSITIVE POWER AT HEATER VALVE GREEN WIRE. AND BLOWER WIRE. CHECK FOR GROUND ON CONTROL HEAD WHITE WIRE. VERIFY PROPER METER FUNCTION BY CHECKING A KNOWN GOOD BATTERY'S VOLTAGE. 6. BLOWER TURNS ON AND OFF RAPIDLY NO MODE CHANGE AT ALL CHECK FOR DAMAGED MODE SWITCH OR POT AND ASSOCIATED WIRING PARTIAL FUNCTION OF MODE CHECK FOR OBSTRUCTED OR BINDING MODE DOORS DOORS CHECK FOR DAMAGED STEPPER MOTOR OR WIRING 7. ERATIC FUNCTIONS OF BLOWER, MODE, TEMP, ETC. TYPICALLY CAUSED BY EVAPORATOR HOUSING INSTALLED IN A BIND IN THE VEHICLE. BE SURE ALL MOUNTING LOCATIONS LINE UP AND DON'T HAVE TO BE FORCED INTO POSITION. 8. WHEN THE IGNITION IS TURNED ON, THE BLOWER MOMENTARILY COMES ON, THEN SHUTS OFF. THIS IS WITH THE BLOWER BATTERY VOLTAGE IS AT LEAST 12V BATTERY VOLTAGE IS LESS THAN 12V CHECK FOR AT LEAST 12V BETWEEN GREEN HEATER VALVE WIRE AND CHASSIS GROUND. INSURE ALL SYSTEM GROUNDS AND POWER CONNECTIONS ARE CLEAN AND TIGHT. CHECK FOR FAULTY BATTERY OR ALTERNATOR CHARGE BATTERY SYSTEM SHUTS OFF BLOWER AT 10V. POOR CONNECTIONS OR WEAK BATTERY CAN CAUSE SHUT DOWN AT UP TO 11V CHECK FOR DAMAGED SWITCH OR POT AND ASSOCIATED WIRING REPAIR OR REPLACE THIS IS AN INDICATOR THAT THE SYSTEM HAS BEEN RE-SET. BE SURE THE POWER WIRE IS ON THE BATTERY POST AND NOT ON A SWITCHED SOURCE. ALSO, IF THE SYSTEM IS PULLED BELOW 7V EVEN FOR A SPLIT SECOND, THE SYSTEM WILL RE-SET. RUN POWER WIRE DIRECTLY TO BATTERY. 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 10 OF 25 24 SWITCH IN THE OFF POSITION.

EVAPORATOR KIT PACKING LIST No. QTY. PART No. DESCRIPTION 1. 2. 1 744004-VUE 1 784163 GEN IV 4 VENT EVAP. SUBCASE 1964 IMPALA w/o AC ACC. KIT EVAPORATOR KIT 561064 CHECKED BY: PACKED BY: DATE: 1 GEN IV 4 VENT EVAP. SUB CASE 744004-VUE 2 ACCESSORY KIT 784163 NOTE: IMAGES MAY NOT DEPICT ACTUAL PARTS AND QUANTITIES. REFER TO PACKING LIST FOR ACTUAL PARTS AND QUANTITIES. 903061 REV A 7/24/08, 1964 IMPALA w/o AC GEN IV EVAP INST PG 25 OF 25