2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation



Similar documents
Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

Transformer Bushings for GIS

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Capacitor Voltage Transformer. Answers for energy.

Instrument Transformers Application Guide

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Unified requirements for systems with voltages above 1 kv up to 15 kv

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

INTERNATIONAL STANDARD

Power transformers. Special transformers Railway

Power Capacitor Units for improved power quality

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Engineering innovation

Table of Contents. TransformerIQ FAQs 1

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

SURGE PROTECTIVE DEVICES

World Leader in HV Testing Technology

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

MIT510/2, MIT520/2 and MIT1020/2

IEC/CIGRE UHV Symposium Beijing KVDC: EXTERNAL INSULATION, INSULATION COORDINATION, TEST LEVELS

Guidance for upgrading to GB (IEC : 2005, MOD)

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

MV POWER CAPACITORS AND BANKS. All film dielectric MV Power Capacitors QUALITY MADE IN ITALY

Protection from Short-circuit

CABLE ACCESSORIES kv

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Mechanical shaft seal types and sealing systems

CAS 36 Ring Main Unit

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

Electronic overload relay EF65, EF96 and EF146

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

Checking Capacitor Banks for Failed Capacitors

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Metal Clad Indoor Instrument Transformer for Plug-In Systems

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

Kuhlman Electric Corporation Volt Instrument Transformers

Electronic overload relay EF19 and EF45

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

DS1 Diode-based transient-free capacitor switch

A Practical Guide to Dielectric Testing

Enhanced Quality with a Touch of Style

Medium voltage insulator

How To Build A Low Voltage Capacitor Lvcp

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

High-Voltage GIS yesterday - today - tomorrow

keep your measure under control

T Substation Maintenance and Commissioning Test Equipment

Pluggable interface relays CR-P Pcb relays

Power Capacitors and Harmonic Filters Buyer s Guide

Voltage Regulator SPAU 341 C. Product Guide

Here is our comprehensive product range dedicated to MV distribution and earthfault compensation.

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Electrical Predictive and Preventative Maintenance

EDITION 2012 CABLE SYSTEMS

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

Tape Wound, Split Core and Ebony Current Transformers

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

DS 600. A contact free flux gate based current measurement sensor 600A rms

IEC & 2 standard. The reference for safe and reliable LV switchboards

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

High Voltage Power Supplies for Analytical Instrumentation

Multi-tap Transformers

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Electrical Considerations for HVDC Transmission Lines. Joe Mooney, PE

Safety technique. Emergency stop module BO 5988 safemaster

Product brochure. Gas-insulated switchgear ELK-3 C, 420 kv High performance in a smaller footprint

Distribution Voltage Regulators

SWITCH YARD OPERATION IN THERMAL POWER PLANT(KaTPP Jhalawar Rajasthan)

IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33.

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

Guide to the electrical parameter classifications of IEC and IEC safety standards

Type: DILM32 10(24V50HZ) Article No.:

Instrument Transformers. Technical Information and Application Guide

SECTION DRY-TYPE TRANSFORMERS

Vario-Series Accessories

Tape Wound, Split Core and Ebony Current Transformers

CT Analyzer: Coming to the Rescue. Introduction. Equivalent Circuit. Construction. Classification of a CT. Tony Porrelli, OMICRON, UK

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Transcription:

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation 123 kv Inductive Fingrid (Finland). 18 Instrument transformers igh voltage

INTRODUCTION Inductive voltage transformers are designed to provide a scaled down replica of the voltage in the V line and isolate the measuring instruments, meters, relays, etc., from the high voltage power circuit. Model UT up to 550 kv. Model UG up to 550 kv. Model UTF Model UTE Model UTD Model UG Instrument transformers igh voltage 19

SECTIONS 1. Oil level indicator 2. Primary terminal 3. Oil volume compensating system 4. Capacitive bushing 5. Oil-paper insulation 6. Compensation windings 7. Primary windings 1 8. Secondary windings 9. Core 10. Insulator (porcelain or silicone rubber) 11. Tangent delta measuring tap 12. Secondary terminal box 13. Oil sampling valve 14. Grounding terminal 15. Pressure relief device 16. V Electrode 17. LV Electrode 18. Manometer 19. Gas filling valve 2 2 15 3 4 5 6 16 7 10 8 9 17 10 18 7 8 11 12 13 9 12 19 14 Model UT. From 362 kv Model UT. Up to 300 kv Model UG. Up to 550 kv 20 Instrument transformers igh voltage

APPLICATIONS Ideal for installation at metering points due to its very high accuracy class. Suitable for the discharge of high-voltage lines and capacitor banks. Excellent frequency response; ideal for monitoring power quality and measuring harmonics. Examples of applications: 1. Revenue metering. 1. 123 kv Inductive voltage transformers (Bosnia). M 2. Discharge of capacitor lines and banks. 2. 123 kv Inductive Transpower (New Zealand). 3. Protection for high voltage lines and substations. 4. Supply for auxiliary services. 3. 420 kv Inductive Rede Eléctrica Nacional (Portugal) 4. 420 kv Inductive voltage transformer. R.E.E. (Spain). Instrument transformers igh voltage 21

DESIGN AND MANUFACTURE Voltage transformers can have several secondary windings for metering and/or protection. The primary winding and all the secondary windings are wound around the same core, which is loaded with the total burden. The core and the windings are located inside a metallic tank. The windings have an antiresonant design, which makes the transformer work properly both at power frequency and during temporary high frequency transients. ADVANTAGES Very high and invariable accuracy (up to 0.1%) steady for the operational life of the equipment, with maximum reliability. Anti-resonant winding design. Safe design in case of internal fault thanks to: - Active parts located inside metallic tank, separated from the insulator. - Pressure relief devices. - Electrical connections resistant to short circuit. Robust mechanical strength and reduced size due to a compact design that is easy to transport, store and install, and which reduces visual impact. ermetically sealed to guarantee complete water tightness with the minimum volume of oil or gas (Each unit is tested individually). Maintenance-free throughout their lifespan. Excellent response under extreme weather conditions, altitudes over 1,000 m.a.s.l., seismic hazard areas, violent winds, etc. Each transformer is routine tested for partial discharges, tangent delta (DDF), insulation and accuracy and designed to withstand all the type tests included in the standards. Compliance to any international standards: IEC, IEEE, UNE, BS, VDE, SS, CAN/CSA, AS, NBR, JIS, GOST, NF. Officially homologated in-house testing facilities. May be transported and stored horizontally or vertically. OPTIONS: Wide range of primary and secondary terminals. Sealable secondary terminals. Secondary terminal protection devices inside the terminal box. igh and steady accuracy, combined with safe design and maximum reliability. Oil level indicator. Various types of insulators available (silicone, gray porcelain, coloured porcelain ). 22 Instrument transformers igh voltage

OIL-PAPER INSULATION: Oil level compensating system that effectively regulates changes in oil volume mainly caused by temperature. Oil sampling valve for periodic analysis. Environmental-friendly design through the use of high quality insulating oils free of PCB. The materials used are recyclable and resistant to the elements. OPTIONS: Silicone rubber insulator. Oil compensation system with metallic bellows. Option for rubber diaphragm up to 170 kv. Current through connection to the V: line. GAS INSULATION: Total safety in case of internal arc: Overpressure is relieved by the pressure relief device (rupture disc) in the top part of the transformer. Designed to minimize gas volume, pressure and leaks, with a leakage rate <0.5%/year (lower values available upon request), thus reducing its environmental impact. Online monitoring of the insulation status with a manometer alarm. Tanks and insulators are designed, manufactured and tested according to international pressure vessel standards. Designed to withstand rated voltage with internal atmospheric gas pressure. 420 kv Inductive R.E.E. (Spain). Instrument transformers igh voltage 23

RANGE ARTECE inductive voltage transformers are named with the letters (UT oil-paper or UG gas) followed by 1 additional letter (oil paper only), and 2 or 3 numbers indicating the maximum voltage of the network for which they are designed. The table on the next page shows the range of both types of transformers currently manufactured by ARTECE. These characteristics are merely indicative; ARTECE can manufacture inductive voltage transformers to comply with any domestic or international standard. Standard accuracy classes and burdens: According to IEC standards 100 VA Class 0,2 / 3P 250 VA Class 0,5 / 3P According to IEEE standards 0.3 WXYZ 1.2 WXYZ, ZZ igher accuracy classes and burdens available. B B B A Models UTB/UTD/UTE/ UTF/UTG up to 300 kv A Model UTF from 362 kv A Model UG up to 550 kv 123 kv Inductive Electronet Services (New Zealand). 420 kv Inductive Elia (Belgium). 24 Instrument transformers igh voltage

Oil-paper insulation > Model UT Model ighest voltage (kv) Power frequency (kv) Rated insulation level Lightning impulse (BIL) (kvp) Switching impulse (kvp) Thermal burden (VA) Standard creepage distance Dimensions A x B Weight (kg) UTB-52 52 95 250-1500 1300 300x300 1335 95 UTD-52 52 95 250-2000 1300 330x300 1395 150 UTB-72 72.5 140 325-1500 1825 300x300 1335 108 UTD-72 72.5 140 325-2000 1825 330x300 1395 150 UTE-72 72.5 140 325-2500 1825 400x430 1645 285 UTD-100 100 185 450-2000 2500 330x300 1690 165 UTD-123 123 230 550-3000 3075 350x475 2120 292 UTE-123 123 230 550-3500 3075 350x475 2120 355 UTE-145 145 275 650-3500 3625 350x475 2105 335 UTE-170 170 325 750-3500 4250 350x475 2235 350 UTF-245 245 460 1050-3500 6125 450x590 3210 650 395 950 UTG-245 245 460 1050-3500 6125 500x640 3260 800 395 950 UTG-300 300 460 1050 850 3500 7500 500x640 3660 910 UTF-420 420 630 1425 1050 3500 10500 600x600 5210 1315 575 1300 950 UTF-525 550 (525) 680 1550 1175 3500 13125 600x600 6070 1700 Approximate dimensions and weights. For special requirements, please consult. Gas insulation > Model UG Model ighest voltage (kv) Power frequency (kv) Rated insulation level Lightning impulse (BIL) (kvp) Switching impulse (kvp) Thermal burden (VA) Standard creepage distance Dimensions A x B Weight (kg) UG-123 123 230 550-1000 3813 315x315 2400 450 UG-145 145 275 650-1000 4495 315x315 2400 450 UG-170 170 325 750-1000 5270 315x315 2600 470 UG-245 245 460 1050-1000 7595 450x450 3200 650 UG-300 300 460 1050 850 1000 9300 450x450 3550 700 UG-362 362 510 1175 950 1000 11222 600x600 3900 1100 UG-420 420 630 1425 1050 1000 13020 600x600 4600 1200 UG-550 550 680 1550 1175 1000 17050 600x600 5100 1300 Approximate dimensions and weights. For special requirements, please consult. Instrument transformers igh voltage 25