ACL 600 Stati-Check Meter

Similar documents
ACL 395 Resistivity Meter

ACL 800 MEGOHMMETER OPERATION MANUAL

The Prevention and Control of Electrostatic Discharge (ESD) (AN )

The Prevention and Control of Electrostatic Discharge (ESD) (AN )

OHM-STAT CT-8700 OWNERS MANUAL & OPERATION GUIDE

THE 7 SINS OF ESD CONTROL CERTIFICATION TEST (DVD-78C)

Guidelines how to set up an ESD Protected Area (EPA)

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Replacing the Gateway M675 Keyboard

Replacing the Gateway M320 Keyboard

Odyssey of the Mind Technology Fair. Simple Electronics

3M Wrist Strap and Footwear Tester 740. User s Guide

W ant to accomplish something

Tech Brief Surface Resistance Test Kit Operation and Maintenance

Periodic Verification System Model 775PVS

Controlling Static Electricity in Modern Buildings

Building the AMP Amplifier

12 Volt 30 Amp Digital Solar Charge Controller

3 740 Wrist strap + shoe tester

ESD/EOS ESD Electrostatic Discharge (ESD) Why Should I Care About Electrostatic Discharge?

Service Guide. Gateway M275

Wall-Mounting your HP computer. User Guide

Example ESD Control Program Document Based on ANSI/ESD S

Lithium-ion battery technology: Getting the most from Smart Batteries

BUILDING A BASIC CIRCUIT

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Care and Handling of Your VAIO Computer

LITHIUM BALANCE CHARGER

AM/FM Aircraft Radio ( ) Features Faxback Doc. # 17253

Lab 3 - DC Circuits and Ohm s Law

APPLICATION NOTES FOR SMD LEDs

Senses SV series industrial monitor user manual

New Printhead. Properly Maintained Printhead Over 1 Million Inches

= V peak 2 = 0.707V peak

Use ESD Control Products Correctly Or You Can Do More Harm Than Good

Peasouper Operator s Manual

FUNDAMENTALS OF ESD. A Primer on Electro-Static Discharge

AutoRanging Digital MultiMeter

Resistance, Ohm s Law, and the Temperature of a Light Bulb Filament

StorTrends 3400 Hardware Guide for Onsite Support

Model 349KLX Remote Display Digital Scale User Instructions

Power Lift & Recline Chair

V281C/D and W281C/D 1.0 mm Coaxial to Waveguide Adapters. Operating and Service Manual

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

FC6 FOOT CONTROLLER OWNER S MANUAL

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

TIG INVERTER INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Manual Ranging MultiMeter

My Weigh Ultraship Series User Manual

Microwave Meter. Instruction Manual

CONTENTS. 1. Fitting the Battery

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Resistors in Series and Parallel

BUILDING INSTRUCTIONS

SERVICE GUIDE. Gateway Notebook

EasyNote TJ Series. Disassembly Manual

AM/FM VHF TV Pocket Radio ( ) Features Faxback Doc. # 18055

Reverse Cycle Inverter Split System Air Conditioner

Charge Regulator SCR 12 Marine

PCI Express USB 2.0 Adapter Card

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Test Reports with Ameriworx Conductive Vinyl Tile ANSI ANSI ESD S7.1 ESD STM97.1 ESD STM97.2

Technical Update TAA.TU Rev. 1

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

User Manual HomeGrid 3000 Solar Generator

Operating instructions Platform/floor scales

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Light Meter (Foot Candles)

Lab E1: Introduction to Circuits

Upgrading and Servicing Guide

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OHM S LAW AND RESISTANCE

Diagnosing and Understanding Starting Problems on the ZR-1 Marc Haibeck 28-Sep-13

Solar Controller / Battery Charger User s Manual

Electrical Fundamentals Module 3: Parallel Circuits

Toroidal Conductivity Sensor

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Automatic Wrist Blood Pressure Monitor with

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Automotive Electronics Council Component Technical Committee

Yoke harness color code: Horizontal: Red & Blue. Vertical: Yellow & Brown, or Yellow & Green, or Violet and Brown.

3. Enter the first five digits of desired frequency ( for MHz).

12-Volt Negative Ground Installation Instructions

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

Load Cell Troubleshooting

SOLAR POWER - THE NEW WAY TO RV!

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Max load: 450/625lbs, 205/285kg

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Essential Electrical Concepts

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Transcription:

ACL 600 Stati-Check Meter OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. 840 W. 49 th Place Page 1 of 5 info@aclstaticide.com

FEATURES Quick visual display of static from 0-19,990 volts Touch to test static in both positive and negative polarity Easy to ground by simultaneously touching 10mm snap contact Low battery indicator built into liquid crystal display (LCD) Micro-power circuit allows 9-volt alkaline battery to continuously display for approximately six months Conductive static-safe carrying case with protective anti-static foam included Detects how much static a person is carrying Audits any potential static generator or dissipater including the following: Wrist straps, heel grounders, toe straps, static-safe shoes, chairs, table mats, floor mats, ground leads, purpose-built floors, garments, static sprays, floor finishes, the difference in potential between two people or materials, etc. INTRODUCTION The ACL 600 Stati-Check Meter is a simple, easy-to-use and inexpensive unit that indicates how much static is present on a person and that drains the charge to the connected ground. This unit can be held in the hand or mounted to a wall. The ACL 600 Stati-Check Meter is the all-around audit tool for your protection against static. OPERATION Before using the ACL 600 Stati-Check Meter for any of the below tests, ground the meter using the provided six-foot cord. The cord has a 10mm snap at one end and a 4mm banana plug at the other end. The 10mm snap and the 4mm banana plug are a common ground on the ACL 600 Stati-Check Meter. NOTE: Failure to ground the unit can result in inconsistent results. If the ACL 600 Stati-Check Meter is not grounded, a charge is retained, resulting in inconsistent readings. The circuit will only become responsive when offered a path to ground. Standard Test To check for a static charge or buildup on a person and to ground the charge, simply set the unit in a convenient place and press a finger to the rectangular Touch to Test plate. The LCD will display a range of 0000 volts to 19,990 volts on the LCD depending on the static buildup on the person undergoing the test. Then touch the 10mm stud next to the word Ground. This will discharge any static charge immediately. Testing Other Items A. Wrist strap and cord: Connect the 10mm snap into the 10mm stud on the ACL 600 Stati-Check Meter. Shuffle feet while touching the rectangular Touch to Test plate. If the wrist strap and cord are functioning properly, the ACL 600 Stati-Check Meter will display 0000 volts on the LCD. Disconnect the wrist strap from the cord and repeat the test while touching the plate and shuffling 840 W. 49 th Place Page 2 of 5 info@aclstaticide.com

feet again. Depending on humidity and type of footwear, a reading of several thousand volts of static charge may be displayed. B. Coil cords and ground leads: These can be checked the same way as above, by holding the bare metal/conductive connection to the Touch to Test plate. C. Custom floors, floor coatings, floor mats and carpet sprays: Hold the meter with thumb or fingers making contact with rectangular Touch to Test plate. Wearing heel grounders or other ESD footwear, shuffle feet on floor under evaluation while still making contact with Touch to Test plate. If floor has been properly grounded, the LCD will display 0000. Try the same test on a known insulative floor while wearing the same footwear. Shuffle feet again to see that even with perfectly good footwear, a charge can be generated on an insulative floor. Finally, try the test on the insulative floor but with rubber-soled shoes and several thousand volts will be displayed. D. Chairs or chair covers: Hold the meter with thumb or fingers making contact with rectangular Touch to Test plate. Sit on the grounded chair and shuffle back and forth. If the chair or chair cover is working and grounded, then 0000 volts will be displayed on the LCD. Disconnect the chair or chair cover from ground or use an insulative chair, and make sure that any floor mats are not grounded. Shuffle again and the ACL 600 Stati-Check Meter will show that even little movement will generate large charges. E. Bonding plugs and common ground boxes: If ground is faulty or the bonding plug/common ground box has a fault, the ACL 600 Stati-Check Meter will display a charge. Repeat the process used for checking ground leads using a known working ground (i.e. outlet or other grounded surface). F. Difference in potential: Two people are needed for this test. Person #1 begins by holding the ACL 600 Stati-Check Meter and making contact with the rectangular Touch to Test plate with thumb or fingers. Person #1 then passes the meter to Person # 2 who will touch the rectangular plate and observe the value displayed on the LCD to determine the difference in charges between himself and Person # 1. This simulates the charge generated by Person # 1 passing a PCB (Printed Circuit Board) to Person # 2 if both persons were not grounded with footwear and/or wrist strap. There is a potential of several thousand volts to be generated by passing a PCB from one person to another. The ACL 600 Stati-Check Meter can be applied to many other types of static control products in various static control situations. FREQUENTLY ASKED QUESTIONS Q. Why do I need to use the ACL 600 Stati-Check Meter? A. The ACL 600 Stati-Check Meter is a visual method of auditing an ESD-protected area. The level of static charge generated by human contact or man-made products within the protected area is clearly displayed on the LCD. The static charge range is 0-19,990 volts of the Human Body Model (HBM). The meter also gives a day-to-day check on performance of conductive, dissipative, and anti-static products used within an ESD-protected area. 840 W. 49 th Place Page 3 of 5 info@aclstaticide.com

Q. Does the ACL 600 Stati-Check meter need to be grounded in order to work properly? A. Yes. If the meter is properly grounded, when a test is performed the meter will read voltage and will slowly drain the charge to zero. If the meter is not properly grounded, when a test is performed the displayed value will be inaccurate and the voltage will remain on the person or object under test, as it has nowhere to drain. Q. When I touch the stainless steel Touch to Test plate and a static charge is displayed, how do I discharge the static? A. First you must make sure that the ground lead is connected to the 4mm banana socket and the lead is connected to ground. Then touch the 10mm stud next to the word Ground. This will discharge any static charge immediately. Q. The ACL 600 Stati-Check Meter indicates 0-19,990 volts (HBM). The 0-9 volts are obviously indicated by the printed zero on the label, units of ten (10) are shown with the first display digit and so on. However, if the meter displays voltage up to 19,990 volts, why is the fourth digit not displayed? A. The meter uses a 3 ½ digit display, therefore the 10,000 + volt display is shown when you are in excess of 10,000 volts (i.e. the 1 will then appear). Q. If the meter measures both positive and negative polarity, why is it that only the minus (-) sign shown on the display? A. A negative charge is indicated by the display of the minus (-) sign. For a positive charge, no indication of polarity is displayed. Q. Do I affix the unit to a wall outside the ESD-protected area or use it as a pocket /mobile meter? A. Either option is acceptable. If the meter is wall-mounted outside the ESD-protected area, it will serve as an educational entry system. By touching the meter and then discharging before entering the protected area, operators and customers will become aware that they carry excessive charges. Q. After I discharge (ground) myself, do I need to take any further precautions? A. Because static charges are constantly generated by materials worn or handled, personnel must be grounded constantly. The ACL 600 Stati-Check Meter will indicate if a wrist strap is grounded by touching the stainless steel Touch to Test plate. If the user is properly grounded, a zero voltage will be displayed even while shuffling feet. If the user is not properly grounded, then the level of static will be displayed on the LCD. 840 W. 49 th Place Page 4 of 5 info@aclstaticide.com

Q. Will the meter only indicate if wrist straps are not grounded? A. The meter will display voltage from 0-19,990 volts if any product either creates a charge or is not grounded. There is also a difference in potential between two people. This can be displayed by a person toughing the stainless steel plate while handing the meter to another person who also touches the plate. At that point in time the difference in potential between the two people is displayed, simulating one operator passing a printed circuit board (PCB) to another person. Q. What is the 10mm snap on the front of the meter used for? A. The front 10mm snap can be used as a method of grounding charges that are displayed on the LCD when the operator touches the stainless steel plate. For example, as the operator touches the test plate, the voltage may read 500 volts. The operator should then at the same time touch the 10mm snap and the charge will disappear in a split second. The 10mm snap can also be used as a way of grounding the meter if a 4mm banana connection is unavailable. CALIBRATION PROCEDURE 1. Unscrew the unit. Connect 1 volt supply to the input of the meter, i.e. 0 volts to ground (4mm Banana Socket) and 1 volt to the end of R12 on the PCB which is connected to U1 (Large Blue Resistor inside the unit on the PCB). Monitor this voltage with your Digital Volt Meter (D.V.M.) and adjust VR1 (adjustable pot inside the meter on the PCB) until the reading matches the D.V.M. [The 1 volt supply can be an ordinary AA cell]. 2. Power the ACL 600 Stati-Check Meter with a variable supply set to 6.5 volts and monitor this with your Digital Volt Meter. Adjust VR2 (adjustable pot inside the unit) until the LOBAT indication just comes on. Warranty labels are affixed to the outside of The ACL 600 Stati-Check meter. As the above procedure indicates, the unit must be opened in order to calibrate it, thus breaking the labels and voiding the warranty. Sending the meter back to the supplier for annual calibration is recommended. SPECIFICATIONS Power Supply: Battery Life: Operating Voltage: 9-volt PP3 alkaline battery Approximately six months > 6.5 volts.9 volts Lowbat set at 6.5 volts Temperature Range: Operation 40 F to 120 F (5 C to 49 C) Storage 40 F to 95 F (5 C to 35 C) Relative Humidity: 0% to 90% (non-condensing) Accuracy: ± 5% Weight: 220g 840 W. 49 th Place Page 5 of 5 info@aclstaticide.com