ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:



Similar documents
ADU 5. Automatic Distillation Unit

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Everything you need for protection scheme testing

Flash Point. Test Methods

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Density/Specific Gravity/ Concentration Meter DMA 500

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

TR Series Surface Roughness Tester for workshop and laboratory

1.44 kw Programmable DC Power Supplies XLN Series

Multi-Range Programmable DC Power Supplies 9115 Series

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

IR READY TOGO. Spectrum Two FT-IR Spectroscopy

ORGANIC SAMPLE PREPARATION

Discover Your Potential

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

MILESTONE START D. Microwave Digestion System

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Process Instrumentation

Distillation PMA-4. Grabner MINI- FLASH Touch. Grabner MINI- FLASH TAG-4 RT-1 ADU 4+ Grabner MINIDIS ADXpert

Multi-Range Programmable DC Power Supplies 9115 Series

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Discover Your Potential

A-307. Mobile Data Terminal. Android OS Platform Datasheet

5,000 lb Capacity. Wireless Communication Scale

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Tracer Summit Web Server

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

BIOMETRIC SOLUTIONS 2013 ISSUE

The photoionization detector (PID) utilizes ultraviolet

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Tank Gauging & Inventory Management Solutions

Notes. Material 1. Appropriate Flammable Liquids

Unleash Your Potential

OT 40L / 90L. Laboratory Steam Sterilizers

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility 19 April 2011

Vibration analysis and monitoring Compact. Powerful. Modern technology.

rigel 288 Electrical Medical Safety Analyser Key Features Applications

DMA-1 Direct Mercury Analyzer

Cronos -1 Gamma Object / Tool Monitors

JOFRACAL Temperature and Pressure Calibration Software

Distillation of Alcohol

Advanced Solutions for Gas Monitoring

Penetration. Test Methods

Portable Density/Specific Gravity/Concentration Meter DMA 35

T a b l e o f C o n t e n t s

Process Alarm Solutions

Digital input modules

sierra monitor corporation Fire and Gas Detection Systems

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

How To Use An Irius Pid Detector

ADT Payload Monitoring System TEchnology carved for the toughest job

Poor quality welds Machine downtime High maintenance costs Lost revenue

MD SD MS SS MH SH ML SL MT ST

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Solid as a Rock etop 300/400

Pipe Cutting and Beveling Clamshells

Elemental analyzer multi EA 5000

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

Penetration Test Methods

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

High Power Programmable DC Power Supplies PVS Series

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

HYDROGEN PEROXIDE PLASMA STERILIZER

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

MINIMAT-EC-Servo Screwdriver Spindles

Fixed and Adjustable Spacing Electronic Pipettes

The Sievers 900 Series TOC Analyzers

Introducing AUDIT-BUDDY

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

73 Series Spectrophotometers

Blast Vibration and Overpressure Monitor

digital quality control fail pass at your fingertips Smart Metrology Solutions.

MInIMAT-ec. flexible data recording highly accurate

Toxicity. Toxicity monitoring technologies for on line, on location and the laboratory

Introducing... The Word's Most Advance. Biometric Time Attendance Door Access Security System

Machine Safety Design: Safety Relays Versus a Single Safety Controller

Instrumentation for the Plant & Soil Sciences Short Form Catalog

QuickSpecs. HP IP Console Switch with Virtual Media Overview

FMT600BT Transmitter

Multifunction HVAC and IAQ Meter

X Series Application Note 43:

Network Time Accessories LED CLOCK. (for NTP Synchronization)

ADMINISTRATIVE SERVICES MANUAL

Single Mode Fiber Lasers

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

4Sight Calibration Management Software

GC-xt. The most flexible GC /GC-MS liquid sample injector

MILESTONE H E L P I N G C H E M I S T S

Pin & Vee Block Test Machine

Transcription:

PERFORMANCE YOU CAN RELY ON NEW! Peltier Boost Technology TM Patented high-speed heating and cooling technology -25 to 420 C (-13 to 788 F) One Flashpoint Tester for All Applications: Fresh & used oils including fuel dilution measurement Diesel & jet fuel, FAME (biodiesel), asphalt & bitumen Flavors & fragrances, paints & varnishes, solid & liquid waste Mobile laboratories, military applications, flash/no flash tests all this with a single analyzer in full compliance with the safest flashpoint standards ASTM D6450 & D7094, with proven correlation to ASTM D93 & EN ISO 2719 ERAFLASH THE SAFE SIDE OF FLASHPOINT TESTING

Maximum Safety Only 1-2 ml of Sample Continuousely Closed Cup No Open Flame Fast & Easy Cleaning To meet the strict safety requirements in today s high-tech laboratories, ERAFLASH operates in full compliance with the safest Continuously Closed Cup Flash Point (CCCFP) methods ASTM D6450 and D7094. In fact, we have taken CCCFP to the next level. Not only does the small measuring chamber that requires only 1-2 ml of sample remain closed at all times during measurement. There are no open flames or glowing wires at all in the ERA- FLASH. Instead, the flashpoint is detected by pressure measurement inside the closed measuring chamber. Naturally, this design completely prevents the risk of fire or hazardous fumes. The fully heat-insulated sample cup holder is safe to touch even after measurements at very high temperatures. Minimum Maintenance Cleaning after measurements often took time and involved maintenance activities or replacing sensors or other elements of the chamber assembly. ERAFLASH is different. Its innovative CPT-Contamination Prevention Techno logy TM, a combination of an advanced electrode protection and self-cleaning ignition system, reduces cleaning & maintenance to an absolute minimum. Reliable Precision For ASTM D7094 the ASTM Flashpoint Committee officially states that there is no statistically significant bias observed compared to ASTM D93 Procedure A. ERAFLASH makes fully automated flashpoint measurements in strict accordance with the latest flashpoint standards ASTM D6450 & D7094. For your convenience, ERAFLASH additionally offers several correlation methods, which cover all major closed cup methods as well as flash/no flash methods. The correlation methods were developed by eralytics internationally renowned flashpoint specialists, Mr. Andreas Schwarzmann and Dr. Roland Aschauer, who are both long-term members of the ASTM D02.08 flashpoint group. As a result, an extensive list of standards can be selected on the ERAFLASH (c = correlation): ASTM D6450 Continuously Closed Cup ASTM D7094 Modified Continuously Closed Cup ASTM D93c, EN ISO 2719c, DIN 51758c, IP 34c, JIS K 2265c Pensky Martens Closed Cup ASTM D56c TAG Closed Cup ISO 13736c & IP 170c Abel Pensky Closed Cup EN ISO 3679c & 3680c, ASTM D3828c Small Scale Closed Cup and Flash/No Flash methods THE SAFE SIDE OF FLASHPOINT TESTING

High-tech for High Performance The patented PBT - Peltier Boost Technology TM by eralytics opens a new dimension of flashpoint testing. Unrivaled measuring speed complements the widest temperature range ever achieved in a single instrument. High Speed The innovative PBT Peltier Boost Techno logy TM, a patented eralytics innovation, allows for previously unmatched heating and cooling rates. The Peltier elements are arranged above the measuring chamber following a revolutionary concept developed by eralytics innovative R&D team. Paired with the conveniently small size of the sample cup this new design allows turnaround times that are significantly shorter than those offered by all other instruments available on the market. Unmatched Range PBT enables measurements in the temperature range below 0 C and in excess of 200 C without the need to change to a new instrument. This makes the ERAFLASH the first flashpoint tester worldwide to cover the full temperature range of -25 to 420 C (-13 to 788 F) in a single analyzer. Moreover, measurements down to 0 C require no additional external cooling. This unmatched temperature range combined with the typically small footprint of an eralytics analyzer saves laboratory bench space and makes mobile testing more economical than ever before. ERAFLASH

A Single ERAFLASH... Standard Model: EF01 ERAFLASH Flashpoint Tester Temperature range: -25 to 200 C (-13 to 390 F) Temperature Extension Module: EF01-HTM High Temperature Module This module is the temperature extension for the ERAFLASH flashpoint tester to include the range between 200 to 420 C (390 to 788 F). It extends the standard measuring range to the total temperature range of -25 to 420 C (-13 to 788 F). ERAFLASH can be easily upgraded anytime to include this high-temperature functionality....for All Applications ERAFLASH is the most flexible flashpoint tester for reliable measurements of all kinds of liquids and solids today on the market. A small footprint, true portability and its rugged aluminum design are ideal for stationary and mobile laboratories. ERAFLASH also is the instrument of choice for demanding tests, including but not limited to fresh and used oil analysis (fuel dilution curve measurement), product specifications, transport classifications (D.O.T., ADR), forensic analysis, FAME (biodiesel), recycled fuels, hazardous waste (RCRA), etc. The cost savings for expensive samples and for waste disposal as well as the easy cleaning due to the small sample volume make the ERAFLASH also the preferred flashpoint tester for the flavors & fragances, the cosmetics, the paints & varnishes and the bitumen & asphalt industries. The display of the Combustion Graphics TM on the large color touch screen is ideal for R&D applications and for the contamination analysis of demanding samples that contain only small amounts of flammable compounds (e.g. FAME / biodiesel). THE SAFE SIDE OF FLASHPOINT TESTING

Technical Specifications Available Test Methods ASTM D6450 & D7094 Pre-programmed Correlation Methods ASTM D93c, EN ISO 2719c, DIN 51758c, IP 34c, JIS K 2265c Pensky Martens Closed Cup ASTM D56c TAG Closed Cup ISO 13736c & IP 170c Abel Pensky Closed Cup EN ISO 3679c & 3680c, ASTM D3828c Small Scale Closed Cup and Flash/No Flash methods Speed Tests Flash/no flash and fast screening test programs PBT - Peltier Boost Technology TM High speed heating & cooling -25 C to 420 C (-13 to 788 F) with a single analyzer CPT-Contamination Prevention Technology TM Advanced electrode protection and self-cleaning ignition system to reduce cleaning and maintenance to an absolute minimum Combustion Graphics TM Display of combustion characteristics for contamination analysis QuickCal TM Dry Block Calibration with eralytics unique directly attached Temperature Calibration Block (EF01-TCB) for maximum precision Certified Reference Material Calibration program for fast on-site calibration Fuel Dilution Program Automatic fuel dilution measurement for the analysis of used engine oils Temperature Range 0 to 200 C (-13 to 390 F) stand alone. No external cooling is required. -25 C to 0 C (-13 to 32 F) with water cooling / chiller 200 C to 420 C (390 to 788 F) with optional High Temperature Module (EF01-HTM) Temperature Stability 0.1 C (0.02 F) Sample Throughput Up to 12 samples per hour Sample Volume 1 ml (ASTM D6450); 2 ml (ASTM D7094) Interfaces Built-in PC with Ethernet, USB and RS232 interfaces Direct LIMS connectivity via LAN and output to printer or PC Remote Control Remote service capability via Ethernet interface Result Database Over 100,000 detailed test reports stored in internal memory Operators Over 100 operator names memorized PC Software ERASOFT RCS - remote control Windows software for multi-instrument remote control, networking, convenient data transfer and result analysis Alarm Tracking All alarm messages are stored in the database together with the result Power Requirements Auto-switching 85-264 V AC, 47-63 Hz, 100 W (multi-voltage power supply) Field application: 12 V/9A DC (vehicle battery) Dimensions / Weight 22 x 32 x 28 cm (8.7 x 12.6 x 11 in) / 8 kg (17.6 lb) Due to continuing product development, specifications are subject to change. All eralytics products are manufactured under ISO 9001 regulations and are CE compliant. ERAFLASH

PERFORMANCE YOU CAN RELY ON Fast & Easy Operation All eralytics analyzers use an intuitive menu structure that is easy to navigate. Samples need no prior preparation and measurements are done fully automated. The results are displayed immediately after the test on the large and user-friendly color touch screen. The internal memory holds thousands of measurement results. For convenience, data can be directly saved to USB memory sticks for further processing or a thorough analysis. The data format is compatible with most PC spreadsheets, such as Microsoft Excel. Customized print-out designs are available for easy direct printing. Flashpoint testing in four easy steps with the ERAFLASH Select the Standard Select/enter the Sample ID and the Operator Load the Sample Cup Press RUN to start the fully automated measurement ERASOFT RCS Remote Control PC Software The RCS software by eralytics is the ideal tool for operating one or more eralytics analyzers via a PC. As an alternative to LIMS, it allows for convenient data transfer and fast analysis of results. It ideally supports the cuttingedge technology and functionalities built into the eralytics instruments. Multi-instrument networking Remote control Fast & easy data transfer (results, settings, spectra, libraries, etc.) Software upgrade Backup/restore for configurations and unit parameters Convenient analysis of quality-check tracking data THE SAFE SIDE OF FLASHPOINT TESTING

Compact Stand-Alone Analyzer All eralytics instruments are compact stand-alone analyzers with a built-in industrial PC. They represent the latest in technology, designed for longterm, maintenance-free operation. Of course, all eralytics analyzers use cutting-edge industry technology and provide universal data transfer options. Ethernet and USB interfaces allow advanced data management and connectivity to PCs, modern printers, keyboards, PC-mice, barcode readers, or other external equipment. Direct LIMS Communication A direct out-of-the-box connection to LIMS (Laboratory Information Management System) is established with a standard Ethernet cable. No extra software or PC is needed. True Portability The small footprint and the rugged aluminum housing of the eralytics instruments make them the first choice for use in the lab and on-site. Lightweight and built with an integrated carrying handle they are ideally suited for mobile applications. Large Results Memory Data are stored safely in the large results memory, which holds many thousand records. Six user levels and a state-of-the-art password technology protect your test result data from accidental deletion. Service and Remote Control over the Internet At the push of a button, firmware and software updates can be downloaded from the internet. The internet connection also allows to remotely control eralytics analyzers or to perform standard service activities. ERAFLASH

Welcome to a New Era of Petroleum Testing Upgrade your lab to the 21st century. Leverage the accuracy, speed and comfortable ease of use that are characteristic of eralytics instruments. ERAVAP TM Vapor pressure testing at its best - The vapor pressure analyzer for virtually all types of fuel, from gasoline to LPG, that also handles crude oil, and takes tests in full compliance with the latest ASTM and EN ISO standards. With its unmatched precision and measuring stability (r = 0.3 kpa, R = 0.7 kpa) it is the preferred analyzer in laboratories across the world. ERAFLASH TM The safe side of flashpoint testing - The patented PBT - Peltier Boost Technology TM makes the ERAFLASH the first and only flashpoint tester on the market to cover the wide temperature range of -25 to 420 C in a single analyzer. Its small sample size and the continuously closed measuring chamber (ASTM D6450 & D7094) guarantee maximum safety and speed at minimum costs. ERASPEC TM Spectral fuel analysis in seconds - The portable mid-ftir spectrometer that is fully automated and multi-fuel capable. With its patented rugged design, it is perfect for fast gasoline, diesel & jet fuel analysis, delivering precise results for over 40 fuel parameters, like aromatics incl. benzene (ASTM D6277), oxygenates (ASTM D5845), FAME (EN14078), etc. and many fuel properties like Octane, Cetane, Density, Distillation, Vapor Pressure, etc. ERACHECK TM CFC-free oil-in-water testing - The cost-cutting and eco-friendly analyzer with the patented QCL-IR technology allowing an extraction with the inexpensive and CFC-free solvent Cyclohexane. With its high speed and precision, it is the instrument of choice to detect even sub-ppm concentrations of total petroleum hydrocarbons (TPH) or total oil & grease (TOG) in water in full compliance with ASTM D7678. eralytics instruments are available worldwide. An international network of over 50 authorized and well trained dealers is ready to answer your inquiries and to offer local support and service.