Portable petrol storage containers



Similar documents
Petroleum (Consolidation) Regulations 2014

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Wilkins Safety Group

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

BP WIND ENERGY POLICIES AND PROCEDURES

Safe use of ladders and stepladders A brief guide

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Written schemes of examination

Examples of pressure systems and equipment are:

Preventing slips and trips at work A brief guide

Controlling fire and explosion risks in the workplace

Safety Storage Cabinets

Flammable and Combustible Liquids. Slide 1 (of 23)

Inspection Location Standards

Civil Engineering Sector Labour-Management Health and Safety Committee

ADMINISTRATIVE SERVICES MANUAL

SPECIFIC INSTRUCTIONS ON HOW TO PERIODICALLY CHECK FOR STRESS CRACKING CAUSED BY CHEMICALS, HANDLING ABUSE & ENVIRONMENTAL DEGRADATION

Confined spaces can be deadly. What is a confined space?

Sample Written Program. For. Flammable Liquids

Fire & Explosion Risks in Service Stations

OSHA Office of Training and Education 1

Working at height A brief guide

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Working alone Health and safety guidance on the risks of lone working

Personal protective equipment (PPE) at work A brief guide

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

When Completed - Fax to (410)

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Electrical safety and you

How the Lifting Operations and Lifting Equipment Regulations apply to health and social care

Risk assessment. A brief guide to controlling risks in the workplace

Notes. Material 1. Appropriate Flammable Liquids

Health and safety guidance on the risks of lone working

Noise at work. Introduction. What harm can noise cause? A brief guide to controlling the risks. What is this leaflet about?

Control of legionella bacteria in water systems

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

APPLICATION FOR ADR ROAD VEHICLE APPROVAL CERTIFICATE

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Safety at injection moulding machines

Take care with oxygen Fire and explosion hazards in the use of oxygen

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Composite Panel Firewall Systems

FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation

Hazardous Substances and New Organisms Act 1996

: MR MUSCLE Window & Glass Cleaner

The following definitions apply with regard to requirements specified in this document:

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

Safety Data Sheet. (REACH Regulation (EC) No. 1907/2006 No. 453/2010)

Queen's University Environmental Health and Safety

Routers and machining centres

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Druck PV 62x pneumatic/hydraulic pressure stations

A short guide to the Personal Protective Equipment at Work Regulations 1992

Disposal of chemical waste must be regarded as an integral part of all research projects and teaching programs involving chemical use.

3M HEAD PROTECTION. For more information, please visit HARD HATS 101 MANUAL

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

BEDFORDSHIRE FIRE AND RESCUE SERVICE FIRE SAFETY GUIDANCE NOTE NO 40

Guidance notes for completing a detailed manual handling risk assessment

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

The dangers of cellulose nitrate film

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Health and Safety (Sharp Instruments in Healthcare) Regulations 2013

Assembly and Installation Procedures

PBX Series Quick Fit Connector Bimetallic Steam Traps

Material Safety Data Sheet

Dubai Municipality Standard DMS 1: Part 5: 2004

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

Safety requirements for autoclaves

MOISTURE (Karl Fischer, Buffered)

Site sampling and testing of concrete

Flammable Liquids Storage

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Product Bulletin INTEROX HYDROGEN PEROXIDE

Reporting accidents and incidents at work

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Lead and you. Working safely with lead. When are you most at risk? How does lead get into your body?

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference:

INFRARED QUARTZ WALL HEATER

Reporting accidents and incidents at work

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

COMMON LABORATORY APPARATUS

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Safety in isocyanate paint spraying

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Flammable Liquids Storage

have been provided with information on whether they do or do not contain asbestos before starting work;

SunMaxx Solar Filling Station Operating Instructions

The Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations 2009 (as amended) Authorisation No. 284 Rev.

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

We ll help you determine your containment needs

UNIVERSITY OF WISCONSIN MADISON

Need building work done?

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Transcription:

Portable petrol storage containers The Petroleum (Consolidation) Regulations 2014 (PCR), which came into force on 1 October 2014, apply to the following: workplaces that store petrol where petrol is dispensed, ie retail and non-retail petrol filling stations; non-workplace premises storing petrol, for example at private homes, or at clubs/associations (or similar). This guidance provides for suitable portable petrol storage containers that satisfy the requirements of regulations 12, 13, 19, 22 and Schedule 3 of the PCR. It gives practical advice on the design, construction, materials and marking or labelling of containers as required by the PCR, specifies certain construction and performance requirements, together with type testing and production testing procedures that can be used to demonstrate that these requirements are satisfied. General principles The guidance sets out the general principles for the design and manufacture of portable petrol storage containers with specific guidance for the design and construction of plastic and metal containers respectively. The general principles for the design and manufacture of portable petrol storage containers require that they must: have a nominal capacity: no greater than 10 litres if made of plastic; no greater than 20 litres if made of metal; have a total capacity between 10% and 15% more than the nominal capacity; be made of either metal or plastic that is suitable and safe for the purpose and will not significantly degrade due to exposure to petrol or naturally occurring ultraviolet radiation; be designed and constructed so that: they are reasonably robust and not liable to break under the normal conditions of use; the escape of liquid or vapour is prevented; petrol can be poured safely from them; they are not unsteady when placed on a flat surface; be marked or labelled in a legible and indelible form with: the words PETROL and HIGHLY FLAMMABLE; an appropriate hazard warning sign; the nominal capacity in litres; the manufacturer s name and the date and month of manufacture. Page 1 of 7

Plastic containers materials Plastic containers should be made of a moulded polyethylene with a specification suitable for the intended purpose, regarding the characteristics of petrol and the general requirements as set out in the PCR. The containers must be suitable for the intended purpose and, as such, the composition of the material should be known. Although there is currently no International, European or British Standard for the storage of petrol in plastic containers, a UN approved plastic container meeting the performance requirements for the carriage of petrol under the European Agreement Concerning the International Carriage of Dangerous Goods by Road (ADR) would be considered robust for most storage conditions. The container should be of adequate strength in relation to its intended purpose, eg materials such as virgin high-density polyethylene (HDPE) would meet this need. Polyethylenes of uncontrolled composition and mixtures of different grades should not be used. It is recommended that dilution with recycled materials is avoided as it may not be a known or consistent composition and may result in a composition material of lower strength and higher permeability. Plastic containers are not intended for storage in direct sunlight. The container material must be of such a composition that the performance characteristics are not significantly diminished by the adverse effect of exposure to naturally occurring ultraviolet (UV) radiation. The construction material should therefore include adequate UV stabilisation and materials manufactured using hindered amine light stabilisers (HALS) provide efficient stabilisers against light-induced degradation of most polymers. They do not absorb UV radiation, but inhibit degradation of the polymer and are therefore capable of providing long-term thermal and light stability. However, the degradation rate of the container will be susceptible to storage conditions. Anti-spill spout adaptors are available that can be used to prevent flashback of flames and internal explosions when pouring petrol from plastic petrol containers. These adaptors can either be used in place of the spout supplied or may be integrated into the design of the petrol container. A study by HSL (www.hse.gov.uk/research/rrpdf/rr1015.pdf) on a sample of these adaptors has demonstrated that they are capable of preventing flashback but can have limitations in their ability to prevent overfill and spillage. They therefore do not eliminate all the risk involved in using petrol and care is still needed when using them to avoid spillages and accidents. Metal containers materials Although there is currently no International, European or British Standard for the storage of petrol in metal containers, a UN approved metal container meeting the performance requirements for the carriage of petrol under ADR would be considered robust for most storage conditions. Metal containers should be made of a suitably robust construction such as steel sheet or aluminium, and of adequate thickness in relation to the capacity of the container and its intended purpose. A metal container that meets the packaging requirements under ADR would be considered suitable and robust for most storage conditions. Portable petrol storage containers Page 2 of 7

General requirements for plastic and metal containers Capacity and design The nominal capacity of the container is the maximum volume of liquid the container is intended to hold at 20 C, ie no greater than 10 litres if made of plastic and no greater than 20 litres if made of metal. The total capacity of containers must be between 10% and 15% more than the nominal capacity (ie the maximum volume of liquid that the container would hold if filled to the brim). This will allow space for the petrol to expand, eg where the container may be exposed to heat gain. The lids or tops should be well-fitting and made of suitable material to remain secure and prevent the escape or leakage of liquid or vapour, with the closure providing an effective seal at all times when applied. The closure should not show any visible signs of leaking even if the container is on its side or accidentally tipped over. Any opening for filling should allow for the safe filing of petrol from a petrol pump without using a funnel. Any containers equipped with a pouring spout, should be able to be firmly attach it to the opening to allow emptying without spillage. Container colour There are NO restrictions on the colour for plastic or metal containers but general custom and practice is that green is used for unleaded petrol and black for diesel. Labelling All containers must be clearly and correctly labelled so people are aware of their contents and hazards. All containers must be marked or labelled in a legible and indelible form with: the words PETROL and HIGHLY FLAMMABLE ; an appropriate hazard warning sign, for example: 3 the nominal capacity of the container in litres; the manufacturers name and the date and month of manufacture. Portable petrol storage containers Page 3 of 7

Design type and production testing To ensure that petrol storage containers satisfy the specific requirements set out in PCR, design type testing and production testing procedures should be carried out on a sample number of containers by an independent person or competent body. Metal and plastic petrol containers should be subject to, and capable of, meeting the test levels appropriate to the container. A UN approved metal or plastic container that meets the performance requirements for the carriage of petrol under ADR would be considered robust for most storage conditions. Metal containers should therefore be tested in accordance with the performance requirements in Chapter 6.1 of ADR (www.unece.org/fileadmin/dam/trans/danger/ publi/adr/adr2013/english/volumeii). Plastic petrol containers should be tested in accordance with the design type testing outlined later in this document under Type testing Plastic petrol containers. However, plastic petrol containers that meet the performance requirements for the carriage of petrol under ADR would be considered suitable for storage. Before carrying out the tests, containers should be selected for testing where each individual weight (without cap and accessories, where possible) does not differ by more than ± 5% from the mean weight of the total sample of containers. The sample containers should be examined before testing to ensure they meet the capacity and design requirements. On completion of successful testing, the person or competent body carrying out the tests should certify that the containers are suitable and safe for the purpose. Weight and wall thickness Each of the containers should be weighed, where possible, without cap and pouring spout and the weight of the lightest of the sample containers should be determined. This is then considered to be the minimum container weight for further production. The smallest wall thickness should be determined to the nearest 0.1mm from the three lightest containers selected as samples. The smallest wall thickness is considered to be the minimum wall thickness for further production. Each of the following type tests should be carried out on three containers per test, all of which should satisfy the requirements of the respective tests. If any container does not satisfy the requirements of the test in any respect, that container type should be deemed to have failed the type test. Design type testing should be carried out in the following sequence: Strength: Impact (drop) test The containers should remain intact and show no visible leakage when subjected to dropping through a vertical height of 1.2 m onto an unyielding surface, in accordance with the test method applicable to the container. Tightness of closure test The closure should provide an effective seal at all times when applied. The closure should show no sign of leakage when subjected to internal pressure, in accordance with the test method applicable to the container. Strength: Internal pressure test The containers should remain intact and show no sign of leakage when subjected to internal pressure, in accordance with the test method applicable to the container. Portable petrol storage containers Page 4 of 7

Permeability test (plastic petrol containers only) The contents of the closed container should lose no more than 5 g in weight when a full container is kept for 4 hours at a temperature of +75 C, in accordance with the test method for plastic petrol containers. Stress cracking test The container should remain intact and show no sign of leakage when subjected to internal pressure, in accordance with the test method applicable to the container. Production testing Manufacturers should undertake production tests to ensure that the material quality and minimum weight and wall thickness of the containers are maintained. No container (without closure and accessories) should weigh less than the lowest weight determined by the type testing for weight. The composition material of the containers should be tested to ensure that the specification requirements are maintained. Spot checks should also be carried out during each production run to ensure that the wall thickness of the containers is maintained at not less than the minimum wall thickness determined and recorded by the type testing for wall thickness. Tests should also be repeated if a modification to the containers alters the design, material or manner of construction. Type testing plastic petrol containers Strength: Impact (drop) test For the impact test, three containers should be filled to their nominal capacity with water that has an anti-freeze additive and closed with the cap applied using a torque of 3 Nm. The three containers should be kept for 16 hours at -25 C and, immediately thereafter, each tested at room temperature by dropping it from a height of 1.2 m so that it falls once on a corner, once on the cap and once on the point on which it naturally drops when released from a handle-hold. The landing area should be a flat, horizontal, unyielding steel plate or slab concrete or stone. The same containers should be emptied, cleaned out and refilled to nominal capacity with a mixture of water and 20 ml pentane and kept for 6 hours at +50 C and immediately afterwards subjected to the same drop test under the conditions described above. The containers should be visually examined to ensure they remain intact and show no sign of visible leakage when dropped. Tightness of closure This test should be carried out on the caps of three containers whose bases are provided with a connection for a pressure line. Each container should be filled to nominal capacity with a test liquid of 60:40 mixture of filling station regular grade petrol: toluene and closed by the cap tightened using a torque of 3 Nm. The containers should be kept for 14 days at room temperature so that the inside of the caps are in contact with the test liquid. Each container should then be emptied and the pressure line joined to its connection at the base. It should be filled at room temperature with a 5% aqueous solution of suitable wetting agent and closed by the cap using a torque of 3 Nm. With the cap pointing downwards, subject the container to an internal pressure of 1.6 bar at room temperature for 10 minutes. Portable petrol storage containers Page 5 of 7

The containers should then be visually examined to ensure they remain intact and show no sign of leakage on or around the cap. Strength: Internal pressure The internal pressure test should be carried out for each testing pressure shown in the table below on three containers with caps. Testing pressure bar gauge Testing temperature C±10 Duration of test (minimum endurance time) hours 1.6 +75 5 1.0 +75 25 0.5 +75 80 Each container should be filled with water at a temperature of +75 C, the cap applied and tightened using a torque of 3 Nm and placed in a water bath at a constant temperature of +75 C for one hour. The tightening torque should then be checked and adjusted if necessary to 3 Nm. The containers in the water bath should then be subjected to pressure applied through the caps, each of which should be provided with a connection for a pressure line. At the start of each test the appropriate testing pressure should be reached within 10 to 15 seconds. When the test pressure is reached the pressurised test apparatus and container should be isolated, and the test temperature maintained for the appropriate test period. During the test, the containers should remain intact and the pressure gauge readings observed to ensure there is no sign of leakage. Permeability Three containers should be filled to their nominal capacity with a test liquid of 60:40 mixture of filling station regular grade petrol: toluene, and closed by application of the caps tightened using a torque of 3 Nm. The containers should be kept for 14 days at + 20 C, placed in such a way that the inside of the caps are in contact with the test mixture. The containers should then be emptied, refilled to their nominal capacity with the test liquid and kept for 4 hours at +75 C in a hot cabinet with appropriate precautions taken to prevent or minimise the effects of a vapour fire or explosion. The filled containers should be weighed at room temperature before the storage period at +75 C and then again after the container and contents have regained room temperature following the latter period. The loss in weight of the contents of the closed container should be determined as an indication of the permeability to petrol vapour and should be no more than 5 g. Strength: Stress cracking The test should be carried out on three containers with caps provided with connections for pressure lines. The containers should be filled with a 5% solution of suitable wetting agent at +75 C, closed with the cap applied and tightened using a Portable petrol storage containers Page 6 of 7

torque of 3 Nm. The containers should be kept for one hour in a bath of the same wetting agent solution at the same temperature. Each container should then be subjected to a pressure of 0.5 bar, which should be reached within 10 to 15 seconds. When the test pressure is reached the pressurised test apparatus and container should be isolated, and the test temperature maintained for the test period of 5 hours. During the test, the containers should remain intact and the pressure gauge readings observed to ensure there are no signs of leakage. Further information For information about health and safety, or to report inconsistencies or inaccuracies in this guidance, visit www.hse.gov.uk/. You can view HSE guidance online and order priced publications from the website. HSE priced publications are also available from bookshops. This guidance is issued by the Health and Safety. Following the guidance is not compulsory, unless specifically stated, and you are free to take other action. But if you do follow the guidance you will normally be doing enough to comply with the law. This leaflet is available at www.hse.gov.uk/fireandexplosion/petroleum.htm. Crown copyright If you wish to reuse this information visit www.hse.gov.uk/copyright.htm for details. First published 10/14. Published by the Health and Safety 10/14 Page 7 of 7