SafeSite LED Based Signaling for Hazardous Locations

Similar documents
DuroSite LED End-to-End Linear Fixture - NSF. for Indoor and Outdoor Industrial Applications

SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

Dialight Control and Monitoring System for Vigilant LED Based Obstruction System for High Intensity Installations. FAA Type B FAA Type C FAA Type F

DuroSite LED Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

SafeSite LED High Bay - UL 844 for Indoor and Outdoor Hazardous Applications

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

DuroSite TM High Bay Lighting

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

Dialight LED Lighting Fixture Catalog. for Indoor and Outdoor Industrial and Hazardous Locations

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Plug and Socket Devices SolConeX 16 A Series 8570

Technical data sheet TDS0070

Explosion-Proof Electric Unit Heaters

Floodlight Range Installation Guide

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Microcor Wireless Transmitter (MWT)

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Scraper Passage Indicator. Electrical Indicator. Features

Flameproof Audible Signal 115 db (A) Series YA90

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

3500/93 System Display

Operating Instructions

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

CompactLogix Power Supplies Specifications

Electronic, Digital and Mechanical Vibration Switches

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

ADDENDUM #1(BID PACKAGE # 3)

Item Number Description Type of Gauge Size in " Price

Specification Requirements DBL 700MX and 1000MX Series UPS

1756 ControlLogix Chassis Specifications

Technical Information RIA14

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Product Specification instalert Rapid Messenger Variable Message Sign

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

7 Lighting Technology

Advantium 2 Plus Alarm

Linear Luminaire with LED Series EXLUX 6402/2

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

POINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED RED OBSTRUCTION SYSTEM

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Model #: SMART2200CRMXL

3DLevelScanner II TECHNICAL DATA SHEET

B-Series Temperature Switches

LED Anti-Collision Lighting System for Airbus A320 Family

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

ALARMLINE ANALOGUE Linear Heat Detection System

Plug and Socket Devices CES 63 A Series 8579

Table 24 - Environmental Specifications M Performance Monitors. NEMA/UL 50 Type 1, 4, 4X, 12, and IEC IP66

Flame detection across the spectrum. Range Brochure

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Switches & Pilot Devices

commercial LUMINAIRE COMPONENTS WARRANTIES MADE IN CANADA MU-AL MU-AN

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Power Supplies 3. SDN-P DIN Rail Series

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

OUTPUT CABLE CONNECTIONS:

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

M-series MD Plus Controller

Signal Tower modulsignal50

LED High Bay Light 100W

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Terminal Boxes Series 8146

How To Use A Ds340 (Dsp)

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications.

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

STB Series Enclosures

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

AIS750 Series Alarm Annunciator

SITRANS F flowmeters SITRANS F M

WHOLESALE DIRECT INC WEST 65TH STREET

1788 Linking Device Specifications

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

8146/5 Series Breaker Panelboards

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

DeltaV SISnet Repeater

B-Series Switches Pressure, Differential Pressure & Hydraulic

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Design and Construction Criteria C. Utility Coordination

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

LED LIGHTING. A team at your service

2.12. page Products for Explosion hazardous Environment

Transcription:

SafeSite LED Based Signaling for Hazardous Locations

On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSFSTBROCHURE_F

Features & Benefits 5 year full performance warranty Resistant to shock and vibration High impact polycarbonate lens, UV, scratch & chemical resistant lens coating Reduction in expensive tower climbs and maintenance costs / unplanned site visits Requires smaller gauge wire Smallest Flash Head in the Industry Community friendly lighting system Dialight Timeline 1999 - First ever FAA certified LED L810 2001 - First ever FAA certified LED L864 2007 - First ever FAA certified LED L865/L864 2011 - First ever FAA certified LED L856 2012 - First ever FAA certified LED L856/L864 Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial and hazardous areas as well as transportation and infrastructure applications. For 40 years it has been committed to the development of LED lighting solutions that enable organizations to vastly reduce energy use and maintenance needs, improve safety, ease disposal and reduce CO2 emissions. www.dialight.com MDTFSFSTBROCHURE_F 3

SCALE 0.375 SafeSite Hazardous Signals LED Based Signaling SafeSite L-864 Red LED Beacon Class I, Div 2 models FAA approved (Check FAA Website for current certification) Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP66 NEMA 4X DGAC Mexico ICAO (Annex 14 - Fourth Edition, July 2004) Canadian aviation regulation CAR 621.9 (Transport Canada) Features & Benefits 5 year full performance warranty Uses 90% less energy than an incandescent Resistant to shock and vibration Drasticly reduces maintenace costs Flash or steady burn Mechanical Information: Fixture weight: Operating Voltage: 20 lbs 120-240V AC 50/60Hz power factor corrected supply Supply Voltage Ranges: Nominal +/- 10% Effective Intensity: Wattage: Red Night 2,000 cd Red Night 20W (Steady Burn) 3.3W (16.7% duty cycle) 20 flashes per minute with 0.5 second on time Power Factor: >0.9 Operating Temp: -40ºF to +131ºF (-40ºC to +55ºC) Synchronization: Multiple unit sync from single controller (Operates with other manufacturers of GPS sync devices) US Patent # 7,281,821 Temperature Ratings Ambient Temperature Range T4A -40ºF to +131ºF (-40ºC to +55ºC) Flip top design for simple installation Part Number Description Voltage Certification / Compliance D464-B13-001 Class I, Div. 2 Beacon 120-240V AC FAA (TC) L-864 4 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling SafeSite LED Based L-864 / L-865 Flashing Dual (White / Red) - Class I, Div. 2 SafeSite FAA approved (Check FAA Website for current certification) Class I, Div 2, Groups A, B, C, D Class II, Div 2, Groups F, G UL1598 UL8750 CSA C22.2 IP66 ICAO Annex 14, July 2009 ICAO Aerodromes Design Manual, Chapter 18 Canadian Aviation Regulation CAR 621 (Transport Canada) Mechanical / Electrical Information: Unit weight: Operating voltage: Effective intensity: Synchronization: 26 lbs (11.8 kg) White - 150V DC (through Controller) Red - 75V DC (through Controller) White Day - 20,000 cd White Night - 2,000 cd Red Night - 2,000 cd Multiple unit sync from single controller (operates with other units via RS485) US Patents #7,208,881 #7,568,821 7,604,380 #7,777,424 Flip top design for simple installation Temperature Ratings Ambient Temperature Range T5-40ºF to +131ºF (-40ºC to +55ºC) Part Number Description DHZ - BFHD - 8C Red / White Flashhead www.dialight.com MDTFSFSTBROCHURE_F 5

SafeSite Class I, Div.2 rated L-864 Systems Example layout Hazardous Signals LED Based Signaling 3 x L-810 Photocell AC Class I, Div.2 rated L-864 / L-865 Systems Example layouts 3 x L-810 L864 / 865 Photocell AC RS 485 Controller AC Power Supply 3 x L-810 L864 / 865 Photocell 3 x L-810 AC RS 485 RS 485 RS 485 Controller AC Power Supply AC Power Supply AC Power Supply 6 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling Vigilant CID2 red L-864 / L-810 Controller Class I, Div. 2 SafeSite Class 1, Division 2 Groups A,B,C,D IP66 NEMA 4X UL 1203, 8750 CSA C22.2 No 30, No. 250.13 Certifications & Ratings 5 year full performance warranty Flashing or steady operation 20, 30, or 40 flashes per minute Front panel indicators (power and alarm) Contact closures for alarms For use with Dialight s fixtures L-864 Red Beacon (CID2) = D464-B13-001 - max 2 per port L-810 Red Marker (CID2) = RTO-2R07-00X - max 8 per port L-810 Red Marker (CID2) = 860-2R01-00X - max 4 per port Multiple controllers can be synchronized for larger systems Corrosion resistant Easy to install Mechanical Information: Fixture weight: 80 lbs (36 kg) Electrical Specifications: Operating Voltage: Operating Temp: Wattage: Temperature Rating: 120-240V AC 50/60Hz power factor corrected supply -40 F to +131 F (-40 C to +55 C) 5W T4 Power Factor: > 0.9 Part Number Description Voltage DHZC-CTR-2C8-000 Controller for L-864 / L-810 Red lights 120-240V AC, 50/60 Hz www.dialight.com MDTFSFSTBROCHURE_F 7

SafeSite Controller for L-864 / L-865 Class I, Div. 1 and Class I, Div. 2 Hazardous Signals LED Based Signaling Class I, Div 1 Class 1, Div 2 Groups B, C, D UL 8750 UL 1203 IP66 T6 temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: Operating voltage: 180 lbs (86.6 kg) 120-277V AC 125V DC Supply voltage ranges: Nominal +/- 10% Power supply wattage: Controller wattage: White Day - 85W White Night - 35W Red Night - 25W 15W The controller will be equipped with a green indicter light on front panel to show energized status as well as a red indicter light on the front panel for failure status. Part Number Description DHZC - CTD - 8C8-030 Controller for up to 3 L-864 / L-865 lights DHZC - CTD - 8C8-040 Controller for up to 4 L-864 / L-865 lights DHZC - CTD - 8C8-060 Controller for up to 6 L-864 / L-865 lights DHZC - CTD - 8C8-080 Controller for up to 8 L-864 / L-865 lights DHZC - PSD - 8C8 Power Supply (1 required per L-864 / L-865 light) 8 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling Power Supply for L-864 / L-865 Class I, Div. 1 and Class I, Div. 2 SafeSite Class I, Div 1 Class 1, Div 2 Groups B, C, D UL 8750 UL 1203 IP66 T6 temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: Operating voltage: 180 lbs (86.6 kg) 120-277V AC 125V DC Supply voltage ranges: Nominal +/- 10% Power supply wattage: Controller wattage: White Day - 85W White Night - 35W Red Night - 25W 15W Part Number Description DHZC - PSD - 8C8 Power Supply www.dialight.com MDTFSFSTBROCHURE_F 9

SafeSite Long Life Photocell Class I, Div. 2 Hazardous Signals LED Based Signaling Class I, Div 2 Groups B, C, D UL 773A ISA 12.12.01 IP66 T4A temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: 2.00 lbs (0.91 kg) Operating voltage: 12V DC (through Dialight Controller) Operating temperature: -40 o F to +131 o F (-40 o C to +55 o C) Part Number Description DHZB - 6000 - PEC Long Life Photocell 10 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling SafeSite L-810 Red LED Side Lights Class I, Div. 2 SafeSite Class I, Div 2 Groups B, C, D UL 1598 UL 844 IP66 T3C temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: 1.25 lbs (0.56 kg) (retro unit) 2.00 lbs (0.91 kg) (single unit) 4.60 lbs (2.09 kg) (dual unit) Operating voltage: 48V DC (through Dialight Controller) or 120-480V AC Operating temperature: -40 o F to +131 o F (-40 o C to +55 o C) US Patents #6,425,678 Part Number Description Description For use with L-864 / L-865 Controller RTO - ER08-001 Single light - 3.5W (for use with L-864/L-865 systems) 12-24V DC RTO - ER08-002 Dual light - 7W (for use with L-864/L-865 systems) 12-24V DC RTO - ER08-004 Retrofit light - 3.5W (for use with L-864/L-865 systems) 12-24V DC For use with L-864 Controller RTO - 2R07-001 Single light - 6.5W (for use with L-864/L-865 systems) 120-240V AC RTO - 2R07-002 Dual light - 13W (for use with L-864/L-865 systems) 120-240V AC RTO - 2R07-004 Retrofit light - 6.5W (for use with L-864/L-865 systems) 120-240V AC www.dialight.com MDTFSFSTBROCHURE_F 11

SafeSite SafeSite L-810 Red LED Obstruction Lights Class I, Div. 2 and ATEX / IECEx - V AC models Hazardous Signals LED Based Signaling FAA approved (Check FAA Website for current certification) Class I, Div 2, Groups A, B, C, D ATEX / IECEx Zone 2 IECEx SIR 08.0018X Sira 06ATEX4372X UL1598 UL844 IP65 / 67 NEMA 4X ICAO (Annex 14 - Fourth Edition, July 2004), DGAC Mexico Canadian Aviation Regulation CAR 621.9 (Transport Canada) Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as single or dual unit Flash models available Withstand wind in excess of 150 mph (240 kph), salt fog Temperature Ratings Class I Div. 2 models ATEX / IECEx models Ambient Temperature Range T4A Ambient Temperature Range T4A -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +131ºF (-55ºC to +55ºC) Mechanical Information Single Units Fixture weight: Mounting: Dual Units Fixture weight: Mounting: Electrical specifications 7.14 lbs (3.24 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting 16.06 lbs (7.28 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting Volt Amps: 44 VA (120V AC ) -+10% 67 VA (230V AC Units) -+15% Input Power: Operating Temp: 14.5 W (120V AC Units) 16.0 W (230V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel US Patent # 6,425,678 12 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling SafeSite L-810 Red LED Obstruction Lights Class I, Div 2 and ATEX / IECEx - V AC models SafeSite Part Number Description Voltage Class I, Div 2 Models 860-2R01-001 Class I, Div 2, Single Unit 120V AC 860-2R02-001 Class I, Div 2, Single Unit 230V AC 860-2R01-002 Class I, Div 2, Dual Unit 120V AC 860-2R02-002 Class I, Div 2, Dual Unit 230V AC ATEX / IECEx Models 860-9R01-001 ATEX / IECEx, Single Unit 120V AC 860-9R02-001 ATEX / IECEx, Single Unit 230V AC 860-9R01-002 ATEX / IECEx,, Dual Unit 120V AC 860-9R02-002 ATEX / IECEx, Dual Unit 230V AC *Steady Burn www.dialight.com MDTFSFSTBROCHURE_F 13

SafeSite Hazardous Signals LED Based Signaling SafeSite LED Steady Burn Visual Signal Lights Colored Visual Signal Lights - Class I, Div. 2 and ATEX / IECEx - V AC models FAA AC No. 150/5345-43G Class I, Div 2, Groups A, B, C, D ATEX / IECEx Zone 2 IECEx SIR 08.0018X Sira 06ATEX4372X UL1598 UL844 Certifications & Ratings IP 65 / 66 NEMA 4X ICAO (Annex 14 - Fourth Edition, July 2004), DGAC Mexico Canadian Aviation Regulation CAR 621.9 (Transport Canada) 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as single or dual unit Flash models available Withstand wind in excess of 150 mph (240 kph), salt fog Mechanical Information Single Units Fixture weight: 7.14 lbs (3.24 kg) Mounting: Dual Units Fixture weight: Mounting: Electrical specifications Threaded 1 NPT and 3/4 NPT bottom hub for mounting 16.06 lbs (7.28 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting Volt amps: 44 VA (120V AC ) -+10% 67 VA (230V AC Units) -+15% Input power: Operating temp: On / off time: 14.5 W (120V AC Units) 16.0 W (230V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900 ms Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel US Patents #7,208,881 #7,568,821 7,604,380 #7,777,424 Temperature Ratings Class I Div. 2 models ATEX / IECEx models Ambient Temperature Range T4A Ambient Temperature Range T4A -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +131ºF (-55ºC to +55ºC) 14 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling SafeSite SafeSite L-810 LED Steady Burn Visual Signal Lights Colored Visual Signal Lights - Class I, Div. 2 and ATEX / IECEx - V AC models Part Number Description Voltage Color Class I, Div 2 - Single Fixture Models 860-2B01-001 Class I, Div 2, Single Unit 120V AC Blue 860-2G01-001 Class I, Div 2, Single Unit 120V AC Green 860-2Y01-001 Class I, Div 2, Single Unit 120V AC Yellow 860-2W01-001 Class I, Div 2, Single Unit 120V AC White 860-2B02-001 Class I, Div 2, Single Unit 230V AC Blue 860-2G02-001 Class I, Div 2, Single Unit 230V AC Green 860-2Y02-001 Class I, Div 2, Single Unit 230V AC Yellow 860-2W02-001 Class I, Div 2, Single Unit 230V AC White Class I, Div 2 - Dual Fixture Models 860-2B01-002 Class I, Div 2, Dual Unit 120V AC Blue 860-2G01-002 Class I, Div 2, Dual Unit 120V AC Green 860-2Y01-002 Class I, Div 2, Dual Unit 120V AC Yellow 860-2W01-002 Class I, Div 2, Dual Unit 120V AC White 860-2B02-002 Class I, Div 2, Dual Unit 230V AC Blue 860-2G02-002 Class I, Div 2, Dual Unit 230V AC Green 860-2Y02-002 Class I, Div 2, Dual Unit 230V AC Yellow 860-2W02-002 Class I, Div 2, Dual Unit 230V AC White ATEX / IECEx - Single Fixture Models 8609B02001 ATEX / IECEx, Single Unit 230V AC Blue 8609G02001 ATEX / IECEx, Single Unit 230V AC Green 8609Y02001 ATEX / IECEx, Single Unit 230V AC Yellow 8609W02001 ATEX / IECEx, Single Unit 230V AC White www.dialight.com MDTFSFSTBROCHURE_F 15

SafeSite Hazardous Signals LED Based Signaling SafeSite FLS LED Flashing Visual Signal Lights Colored Visual Signal Lights - Class I, Div. 2 - V DC models Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP66 NEMA 4X Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: Mounting: Electrical specifications 7.14 lbs (3.24 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting Volt Amps: 44 VA (120V AC ) -+10% 67 VA (230V AC Units) -+15% Input Power: Operating Temp: On / off time: 14.5 W (120V AC Units) 16.0 W (230V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900 ms Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel US Patent # 6,425,678 Part Number Description Voltage Color 120V AC Models FLS-2B01-001 Class I, Div 2, Single Unit 120V AC Blue FLS-2G01-001 Class I, Div 2, Single Unit 120V AC Green FLS-2R01-001 Class I, Div 2, Single Unit 120V AC Red FLS-2Y01-001 Class I, Div 2, Single Unit 120V AC Yellow FLS-2W01-001 Class I, Div 2, Single Unit 120V AC White 230V AC Dual Fixture Models FLS-2B02-001 Class I, Div 2, Single Unit 230V AC Blue FLS-2G02-001 Class I, Div 2, Single Unit 230V AC Green FLS-2R02-001 Class I, Div 2, Single Unit 230V AC Red FLS-2Y02-001 Class I, Div 2, Single Unit 230V AC Yellow FLS-2W02-001 Class I, Div 2, Single Unit 230V AC White 16 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling SafeSite FLS LED Flashing Visual Signal Lights Colored Visual Signal Lights - Class I, Div 2. - V DC models SafeSite Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP66 NEMA 4X Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: 7.14 lbs (3.24 kg) Mounting: Threaded 1 NPT Electrical specifications Operating Voltage:: 12-48V DC (nom) -+ 10% Input Power: 1.5 W Operating Temp: 40ºF to +149ºF (-40 C to +65 C) On/Off Time: 100:900ms Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Construction Housing: Lens: Accessories (Hardware): Cast aluminum Glass Threaded 3/4 NPT reducer Threaded 1 NPT plug Stainless steel cage US Patent # 6,425,678 Part Number Description Voltage Color FLS-2B09-001 Class I, Div 2, Single Unit 12-48V DC Blue FLS-2G09-001 Class I, Div 2, Single Unit 12-48V DC Green FLS-2Y09-001 Class I, Div 2, Single Unit 12-48V DC Yellow FLS-2R09-001 Class I, Div 2, Single Unit 12-48V DC Red FLS-2W09-001 Class I, Div 2, Single Unit 12-48V DC White www.dialight.com MDTFSFSTBROCHURE_F 17

SafeSite Hazardous Signals LED Based Signaling SafeSite FLS LED Flashing Signal Lights With Flat Base Junction Box - Class I, Div. 2 - V AC models Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP65 / 66 NEMA 4X Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: 7.14 lbs (3.24 kg) Mounting: Threaded 1 NPT on 4 sides and 1 on bottom Electrical specifications Volt Amps: Input Power: Operating Temp: On/Off Time: 44 VA (120V AC Units) 14.5 W (120V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900ms Construction Housing: Lens: Accessories (Hardware): Cast aluminum Glass Threaded 3/4 NPT reducer Threaded 1 NPT plug Stainless steel cage Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Part Number Description Voltage Color FLS-2B01-005 Class I, Div 2, Flat Base 120V AC Blue FLS-2R01-005 Class I, Div 2, Flat Base 120V AC Green FLS-2Y01-005 Class I, Div 2, Flat Base 120V AC Yellow 18 www.dialight.com MDTFSFSTBROCHURE_F

Hazardous Signals LED Based Signaling SafeSite SafeSite L-810 LED Visual Signal Lights With Flat Base Junction Box - Class I, Div. 2 models Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP65 / 66 NEMA 4X Features & Benefits 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: 7.14 lbs (3.24 kg) Mounting: Threaded 1 NPT on 4 sides and 1 on bottom Electrical specifications Volt Amps: Input Power: Operating Temp: On/Off Time: 44 VA (120V AC Units) 14.5 W (120V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900ms Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Part Number Description Voltage Color 860-2B01-005 Class I, Div 2, Flat Base 120V AC Blue 860-2R01-005 Class I, Div 2, Flat Base 120V AC Red 860-2Y01-005 Class I, Div 2, Flat Base 120V AC Yellow www.dialight.com MDTFSFSTBROCHURE_F 19

North American HQ 1501 Route 34 South Farmingdale, NJ 07727 Tel: 732-919-3119 Fax: 732-751-5778 info@dialight.com Copenhagen Ejby Industrivej 91 B 2600 Glostrup Tel: +45 8877 4400 E-mail:Info-dk@dialight.com Australia office 38 O Malley St Osborne Park WA 6017 Tel: +61 (0) 8 9244 7600 Fax: +61 (0) 8 9244 7601 Brazil Av. Joao Antonio Meccatti, 1601 Galpao 07 Jd Planalto Jundiai SP 13211-223 Tel: +55 (11) 4431-4300 Fax: +55 (11) 4431-4300 Email:vendas.brasil@dialight.com Houston office 16830 Barker Springs Rd, Ste 407 Houston, TX 77084 EMEA HQ Exning Road, Newmarket Suffolk, England, CB8 0AX Tel: +44 (0) 1638 665161 Middle East office Level 42, Emirates Towers (Office Tower) Sheikh Zayed Road Dubai, United Arab Emirates Tel: +971(0)4319 7686 Southeast Asia office 240 Macpherson Road #07-05 Pines Industrial Building Singapore 348574 Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current models of this document will always be available at: www.dialight.com/assets/brochures_and_catalogs/illumination/ MDTFSFSTBROCHURE.pdf Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT. MDTFSFSTBROCHURE_F