5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. www.airedale.com. Typical Applications



Similar documents
5-60kW. EasiCool Range. - 60kW. Typical Applications

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

60-150kW. For more information on Airedale visit SmartCool kW. > SmartCool.

EasiCool. 6-64kW DX AIR. Precision Air Conditioning

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

CRAC Precision climate control units for data centres

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

ECOCIAT. Domestic hot water heat recovery unit

State of the Art Energy Efficient Data Centre Air Conditioning

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

york air-conditioning products Residential & VRF News 2015

Cool Design for Homes and Offices

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

Chilled Water Precision Air Conditioner For Critical Application

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CE6500 Energy Recovery Ventilator

Bring the fresh in. Dedicated Outside Air Systems

FTQ. Daikin Inverter Ducted Heat Pump

TurboChill & TurboChill FreeCool

Desiccant Air Dryers Heatless, Heated and Heated Blower

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Refrigeration Compressed Air Dryer Buran Ultrapulse

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Split units TH with hermetic compressors

Hiwall Hiross for Telecom. High Performance Air Conditioning

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Split System Cooling Product Data

ThermoStar Refrigeration Air Dryers

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Split System Heat Pump Product Data

SECTION HEAT PUMPS

Split System Cooling Product Data

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

COVER. StoreMaster. Air Handling Unit - Free Cooling, Cooling & Heat Pump 50 kw - 77 kw R410A TECHNICAL MANUAL

- White Paper - Data Centre Cooling. Best Practice

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Split System Heat Pump Product Data

Freezers - Ultrafreezers. Platilab & Irilab Series

Screw Compressors ESM Fixed Speed & VS Variable Speed

Product Data. Split System Cooling F-EN. March 2015

york airside products Delivering precision air conditioning for critical applications Serie R410A Close control air conditioners

Element D Services Heating, Ventilating, and Air Conditioning

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

HVAC and Lighting Control Products for Open Building Automation Systems

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

FTXS. Wall Mount Heat Pump or Cooling Only

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

For every mission, there is a Vector. VECTOR

Rotary screw compressors kw 5,5 7, , bar MODULO

RPV - RP - RA air handling units

Cooling kw Heating kw

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

marine/bespoke split applications

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Eaton epdu. Intelligent and flexible power distribution

IV. Rear Mount System

TWE+TTA TWE+TWA T.R.

Precise, Reliable and Innovative Air Conditioning for Information and Communication Technology

Designer. of control solutions NA O7.124A

PLUG and PLAY VRV Connection

Nirvana. Cycling Refrigerated Dryers

EHDC. Cooling system for Data Center and server cabinets.

TRI-CAPACITY CHANGING THE GAME FOR COMMERCIAL AIR CONDITIONING

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Coldrooms designed for your application

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

JAWAHARLAL NEHRU UNIVERSITY

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

Condensing unit type EPSILON-ECHOS LE Technical information manual

Technical data. Danfoss DHP-A

YCAA-B AIR COOLED LIQUID CHILLER

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Elements of Energy Efficiency in Data Centre Cooling Architecture

Power consumption (kw)

AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

MPR-Systems. Mini Power Racks 1200 W W

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Product catalog UNT-PRC011-E4

HP switch LP switch Discharge thermo Comp. Surface thermo

NSN

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Intelligent Integrated Systems

Transcription:

5-21kW - 21kW > Ecotel Indoor Range Typical Applications > Telecommunications > Internet service providers > Computer rooms > Switching / Relay stations www.airedale.com

Specifications Ecotel Indoor The Ecotel Indoor range of self contained packaged air conditioning units has been specifically designed and purpose-built for indoor telecom applications, including cabins, shelters, computer rooms and telecom base stations. The indoor range is available in upflow and downflow variants comprising six model sizes with cooling capacities ranging from 5kW to 21kW. The range utilises single or dual refrigeration circuits to provide one, two or three stages of cooling, dependent on unit selection, in addition to its standard free-cooling capabilities and uses the latest hermetic scroll compressor technology. The units are constructed of an anodised aluminium frame with bolted, painted steel panels, which can be removed to allow front, side and rear access to interior components. The cabinet provides an airtight enclosure within which the packaged unit is positioned and this, together with the internal acoustic insulation, greatly reduces noise breakout. Key Features > 5kW to 21kW cooling capacity > 6 model sizes > Energy efficient free-cooling operation > Advanced AireTronix controls technology > Low noise > Full 360 service and maintenance access > Upflow and downflow configuration > Small footprint > Direct drive fan technology > Single and dual circuit models > Scroll compressor technology > BMS compatibility > Fully packaged unit Typical Applications Switching Stations Computer Rooms Page 1

Key Features Key Feature : Easy to install, commission, maintain and service All major components, such as the expansion valve and compressor are accessible from the side of the unit and the control panel from the front. Isolated from the air flow, this area can be worked on, (along with the control panel) with the unit in operation, helping to simplify commissioning and maintenance. Designed and delivered as a fully-charged packaged system, the Ecotel Indoor unit eliminates the need for on site pipe work installation. This has the benefit of reducing installation costs in terms of both materials and time. An anodised exo-frame combined with removable access panels allows for 360 unit access if required. Key Feature : Free-cooling When operating continuously 24 hours a day, 365 days a year, there is the potential to reduce the energy consumption of the heat management system by utilising the benefits of lower ambient temperatures for a significant proportion of the year. The internal operating temperatures of modern day telecom cabins is higher than the actual outdoor dry bulb temperature for more than 95% of the year and Airedale have paid specific attention to this factor when designing the Ecotel product. The Ecotel units have been developed to utilise a free-cooling cycle which can totally satisfy the internal heat loads produced by the telecoms equipment for 67%* of the year. *(Based on ambient hours for London produced by the Meteorological Office, Bracknell, UK and cabin setpoint of 27 C) High ambient mode Mechanical cooling Low ambient mode Free-cooling Key Feature : Direct-drive supply air fans Direct-drive backward-curved impeller fans are fitted as standard across the Ecotel Indoor range. A key feature of the direct-drive fan is its high performance impeller that is dynamically balanced for maximum efficiency, offering easy set-up and speed adjustment. The belt-free operation of the direct-drive fans ensures minimal maintenance and eliminates belt particles from contaminating the air flow. Being fully adjustable by means of the microprocessor display, allows for simple alteration of air flow and static pressure, reducing commissioning time to a minimum. Page 2

Techincal Specifications and AireTronix Controls Ecotel Indoor Model No. Total Cooling Duty (kw)* Sensible Cooling Duty (kw)* Nominal Supply Airflow (m 3 /s) Dimensions (H x W x D) mm Operating Weight (kg) Indoor Noise (Sound Pressure @ 3m db(a))** Indoor Noise (Sound Pressure @ 3m db(a))*** ITCU 5 4.8 4.5 0.30 1940 x 600 x 600 185 61 61 ITCU 6.5 6.4 5.6 0.36 1940 x 600 x 600 190 64 63 ITCU 11 11.1 10.0 0.70 2107 x 1067 x 790 280 48 46 ITCU 14 13.2 11.7 0.90 2107 x 1567 x 790 310 57 56 ITCU 17D 14.8 14.1 1.20 2107 x 1567 x 790 420 52 47 ITCU 21D 18.1 16.8 1.50 2107 x 1567 x 790 450 56 54 * Nominal cooling duty based on 24 C db / 19 C wb and 45 C ambient ** Full DX Cooling *** Free-cooling / Evaporator fans only Controller Ecotel Indoor units are equipped with the very latest microprocessors available from Airedale. These fully programmable controllers are specifically developed for use with Airedale air conditioning systems, offering powerful analogue and digital control to meet a wide range of monitoring and control features. The Controller s in-built display allows viewing of the unit s operating status and it s multi-button keypad allows adjustment to control parameters by allowing the operator easy access to a menu system. Standard Microprocessor Features: > 4 x 20 LCD back-lit display > 14MHz 16 bit CPU > Remote on/off capability > Compressor anti-cycle control > Compressor rotation > Duty/standby operation > Duty rotation (network units) > Visual alarm display > Password protection Duty/Standby AireTronix microprocessors can be set-up for duty/standby operation without the requirement for an external sequence panel. Up to six Ecotel Indoor units can be networked together. Connections The controller can be connected and integrated into a wide range of other BMS systems either by using additional internal plug-in serial cards or external gateways. The plug-in serial cards have options to communicate with the following systems Carel, Modbus-Jbus,Trend, Echelon LonWorks devices and Metasys Johnson Controls. With the addition of external gateways the following integration is available - BACnet, Fax, SMS, GSM, SNMP (Simple Network Management Protocol) and Ethernet TCP IP. Supervisory Options AireWorks AireWorks is the software program for the supervision, monitoring and control of chillers and air-conditioning systems managed by AireTronix controllers. AireWorks can act as a server allowing access to a graphical representation using a web browser such as Internet Explorer. AireWeb The AireWeb device is a gateway for interfacing AireTronix controllers to an Ethernet network. The web pages are created based on specific parameters of the installation, and can be adjusted remotely via the internet. GSM For very simple remote alarm indication, a recipients mobile telephone number can be entered into the controller, allowing alarms to be sent to any required person. Airedale International have developed an AireTronix Control Centre at it's corporate headquarters in Leeds. The Centre features live, working AireTronix controllers, including full live technical presentations and pre-sales product demonstrations. The facility also features a remote site monitoring bureau. GSM Page 3

Features & Options Standard Features Through its use of carefully selected components and advanced technological features, the Ecotel Indoor provides a wide range of technical advantages in an excellent value package. AireTronix controls are fitted as standard, to allow for full intelligent control that maximises system efficiency and minimises unit life-cycle costs. > Backward-curved centrifugal fans for improved efficiency and reduced noise breakout > The Ecotel Indoor range has been designed with a small footprint (models 5 & 6.5-600 x 600mm), this enables easier installation and is ideal for limited space applications > Hermetic scroll compressors > Intelligent variable head pressure control ensures energy efficient operation of the condenser fans while protecting the system during low ambient conditions > Large surface area coils positioned to optimise airflow and heat transfer > Sight glass and filter drier included for system reliability > G4-rated pleated disposable filters, give superior performance with lower airside pressure drops > AireTronix controller allows for intelligent unit control and full communication to BMS systems > An outside air damper is capable of supplying 100% fresh air into the room as free-cooling > Spring return damper actuator prevents fresh air entering during off periods or power failure > Dual circuit models available (models 17-21 only) > Flexible design allows for a variety of supply and return air patterns > Master/slave configurations allows up to 6 units to be networked together > Default factory settings allows simple plug in and switch on operation > Standard RAL 7035 colour ensures an aesthetic match to almost all applications Options In addition to its wide range of standard features the Ecotel Indoor range offers a number of enhanced options that can be specified to create a bespoke product that meets each individual customers unique application requirements. > LCD backlit display allows for password protection along with on-site adjustment and interrogation of all major components > Multilingual display (French, German and English) > Modbus, Trend, Lonworks, Carel and Johnson Metasys interface cards ensure full network connectivity > Clock card for date and time tagging of alarms > GSM modem kit for remote alarm monitoring via specified mobile telephones > Epoxy-coated aluminium finned coils can be supplied for atmospheres where high corrosion is anticipated > Electric heating > Mains electric isolator > Unit-mounted emergency stop button > An evaporator filter can be fitted for areas where the unit is exposed to above average levels of airborne particles/debris > Wall transition sleeve and weather louvers > An acoustic jacket can be fitted to each compressor for noise sensitive areas (models 11-21 only) > Split-case design simplifies site access and improves unit mobility (models 11-21 only) Key Feature : Fully packaged indoor unit The Ecotel Indoor is a fully packaged indoor unit incorporating integrated evaporators and condensers. It is designed to be aesthetically pleasing, eliminating the need for external condensers, thereby increasing architectural freedom in the design of roofs and facades. The Ecotel Indoor also benefits from a compact footprint and streamlined interior, easing installation and maintenance. Page 4

> For the latest information on our Close Control products please visit : www.airedale.com > Please refer to the technical manuals for more detailed information > Airedale participates in the Eurovent Certification programme as a founder member. The performance data of certified products is independently verified and identified within the relevant sales literature Your nearest Airedale distributor is: Airedale International Air Conditioning Limited Leeds Road, Rawdon Leeds, LS19 6JY, England T : +44 (0) 113 239 1000 F : + 44 (0) 113 250 7219 E : enquiries@airedale.com W : www.airedale.com All specifications are subject to change without prior notice ENG-CC-ECOIN-08/05