PARTICLE GENERATOR MODEL 8026



Similar documents
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

GENERAL PURPOSE THERMAL MASS FLOWMETER MODEL 4140/4143

Bottom Loading Water Dispenser

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

General Purpose Thermal Mass Flowmeter Model 4140/4143

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

Meaco 30L and Meaco 40L dehumidifier instruction manual

el-720 Carbon Dioxide Gas Leak Detector User s Guide

MODEL G300 BRAKE BLEEDER

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Dehumidifier Users manual. For Models: DH45S DH65S

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Data Analysis Software

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

3 WATT LED SPOTLIGHT Model No. SLM

Installation Instructions

Micron-Master EL Series Fogger

RT-200 HI-TEST ROPE TESTER

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

24.2L M.A.N. V12 Engine Module

ATS Overhead Table Shelf System INSTRUCTION MANUAL

VK-250 WARRANTY REGISTRATION FORM

Architect/Contractor Information Package

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PAINT SPRAY GUN WASHER

Installation, Operation & Service Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Advantium 2 Plus Alarm

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

What you can expect from your Solar Hot Water System

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

Model SRMD Setra Remote Monitoring Display

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

How To Service A Paper Shredder

Espresso/Cappuccino Maker MODELS MEXKITB, MEX1B

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

The Storm 20-Gallon Wet/Dry Vac

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Intelli-Time Alarm Clock model 13027

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Retractable Screen. Replacement Screen Instructions

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Single Station Remote Alarm

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

ClearView 100. Instruction Manual

How To Control A Pressura Room Pressure Monitor

PAPER SHREDDER PRS-F-01 USER MANUAL

User and Installation Guide

Model 349KLX Remote Display Digital Scale User Instructions

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Ozone Generator Manual

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Caller-ID on your TV!

i410/i1010 AC/DC Current Clamp

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

12-Volt 10-Amp Regulated Power Supply

Featuring EP1 EARPHONES. Owner s Manual

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Master Prep Professional

Customer Support

Say Hello to Your Precision Cooker

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

MTV-FS1 / FS1T / FSB375

4 in 1 Air Compressor

Magnetic Stripe Reader-Writer. Magnetic Stripe Reader-Writer. RS232 & USB-RS232 Interface Quickstart Manual

About this Manual. Support for Your Product

Installation and Operating Instructions (for chargers shown below)

IR Repeater. Operation Manual P8620

16/32 Channel 1U Rack Mount CCTV Power Supply

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

ExStik TM ph Waterproof Meters

MaxiMist Spraymate By Earlex

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Owner s Manual & Safety Instructions

81000 Series Aluminum Gate Valve Installation and Repair Manual

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

PORTACOUNT PRO 8030 AND PORTACOUNT PRO RESPIRATOR FIT TESTERS

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

VF400. User Instructions

Unpacking, Installation, and Customization

Transcription:

PARTICLE GENERATOR MODEL 8026 OPERATION AND SERVICE MANUAL P/N 1980319, REVISION M MARCH 2016

Copyright TSI Incorporated / Revision M / 2000 2016 / All rights reserved. Address TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA Fax No. (651) 490-3824 LIMITATION OF WARRANTY AND LIABILITY (effective February 2015) (For country-specific terms and conditions outside of the USA, please visit www.tsi.com.) Seller warrants the goods, excluding software, sold hereunder, under normal use and service as described in the operator's manual, to be free from defects in workmanship and material for 12 months, or if less, the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions and exceptions: a. Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment; b. Pumps are warranted for hours of operation as set forth in product or operator s manuals; c. Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment; d. Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies; e. This warranty does not cover calibration requirements, and seller warrants only that the instrument or product is properly calibrated at the time of its manufacture. Instruments returned for calibration are not covered by this warranty; f. This warranty is VOID if the instrument is opened by anyone other than a factory authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended cleaning; g. This warranty is VOID if the product has been misused, neglected, subjected to accidental or intentional damage, or is not properly installed, maintained, or cleaned according to the requirements of the manual. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller. The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO SELLER S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS. BUYER S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER S OPTION REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS. TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENT SHALL SELLER BE LIABLE FOR LOST i

PROFITS, BUSINESS INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss. Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller. Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call TSI's Customer Service department at (800) 874-2811 (USA) or (001 651) 490-2811, International. Trademarks TSI, TSI logo, and PortaCount are registered trademarks of TSI Incorporated. ii

CONTENTS SAFETY INFORMATION... iv Chapters 1. UNPACKING AND PARTS IDENTIFICATION... 1 Unpacking the Particle Generator... 1 Parts Identification for the Particle Generator... 1 Replacement Parts and Supplies... 2 2. SETTING UP AND OPERATING THE MODEL 8026 PARTICLE GENERATOR... 3 Introduction... 3 Selecting a Fit Testing Location... 3 Setting up the Model 8026 Particle Generator... 4 Operating the Model 8026 Particle Generator... 6 3. MAINTENANCE... 7 Routine Maintenance... 7 Cleaning the Atomizer Nozzle... 7 4. TROUBLESHOOTING... 9 Appendix A. SPECIFICATIONS... 11 AVAILABLE APPLICATION NOTES To obtain any of the Application Notes, contact TSI at: U.S. (800) 874-2811/(651) 490-2811, Fax: (651) 490-3824 International (001 651) 490-2811, Fax: (001 651) 490-3824 Application Notes can also be found on TSI s web site: http://www.tsi.com iii

SAFETY INFORMATION The Model 8026 Particle Generator includes a high-temperature safety switch. If the generator overheats, this switch shuts off the unit permanently, and it must be returned to TSI for servicing. iv

Chapter 1 Unpacking and Parts Identification Unpacking the Particle Generator Carefully unpack the Model 8026 Particle Generator and accessories from the shipping case. Use the tables and illustrations below to make certain that there are no missing components. Contact TSI immediately if anything is missing or damaged. Table 1-1: Model 8026 Particle Generator Component Parts Quantity Item Description Part/Model 1 Particle generator 8026 1 Particle generator power cord 1303567 1 Package of 100 salt tablets 803011 1 Model 8026 Particle Generator Operation and Service Manual 1980319 Parts Identification for the Particle Generator Figure 1-1 identifies the parts of the Model 8026 Particle Generator. Please become familiar with these components before proceeding. Particle Generator Reservoir Figure 1-1 1

Replacement Parts and Supplies The following items are sold by TSI as replacement parts and supplies for the Model 8026 Particle Generator. Table 1-2: Replacement Parts and Supplies Quantity Item Description Part/Model 1 Package of 100 salt tablets 803011 1 Storage lid for reservoir 2002030 1 Power cord (North America) 1303567 1 Atomizer assembly 2401041 2 Chapter 1

Chapter 2 Setting Up and Operating the Model 8026 Particle Generator Introduction The Model 8026 Particle Generator is intended to supplement the naturally occurring particles in the air when performing quantitative respirator fit tests using the TSI PortaCount Respirator Fit Tester. The following setup and operating instructions presume this intended usage. This does not preclude using the Model 8026 Particle Generator for other applications to generate a moderate concentration of poly-disperse particles. Some general notes on alternate uses for the Model 8026 are found at the end of this chapter. Before setting up the Model 8026 Particle Generator, it is important to select a suitable location for fit testing. Selecting a Fit Testing Location The particle generator may be used with the PortaCount fit tester if you are unable to obtain the minimum particle concentration. Important Considerations The Particle Generator or any other sources of particle generation should be kept at least 6 feet from the PortaCount Pro fit tester during operations. For the Particle Generator to function properly, operate the generator and conduct the fit tests in an enclosed area. A room smaller than 400 sq. ft. would provide the best conditions. Particle generation will not function as efficiently in an open cubicle area or a very large room. The Particle Generator and other forms of particle generation should only be used sparingly, when needed. Often they are only needed in the morning hours or at the beginning of fit testing. Do not operate any form of particle generation if ambient particle concentrations are above 8,000 pt/cc (as per use with full- & half-mask, P100 fit testing) or 800 pt/cc (as per use with N95 fit testing). Never split the Twin Tubing assembly in order to move the ambient (blue) tube closer to the Particle Generator. 3

Setting up the Model 8026 Particle Generator The particle generator supplements the naturally occurring particles in the room environment. Follow the steps below to set up the particle generator: 1. Fill the reservoir jar with clean tap water to the fill line. Use room temperature water to help the salt tablet dissolve more quickly. Fill line Figure 2-1 2. Drop one salt tablet into the reservoir. Each tablet contains 100 mg of salt. Break or crush the tablet before dropping it into the water to dissolve it more quickly. 3. Place the temporary cover tightly on the reservoir and shake it gently to dissolve the salt tablet. 4. Once the solution is mixed, remove the temporary cover and screw the reservoir onto the particle generator. See Figure 2-1. 5. Place the particle generator on the floor in a corner of the testing room. Make sure the ventilation louvers on the back and bottom of the generator are not obstructed, as this could cause the instrument to overheat. C a u t i o n Do not place the Particle Generator on the table or benchtop. Vibrations from the internal compressor may cause the generator to move across the table. If left unattended, the generator could fall on the floor resulting in damage to the instrument. 4 Chapter 2

6. Plug the female end of the power cord into the receptacle on the back of the particle generator. Plug the male end into a grounded wall outlet and turn on the power to the generator. The power switch is located next to the power cord receptacle. See Figure 2-2. Power cord Power switch Figure 2-2 Run the particle generator in the testing room, with the door closed, for at least 15 minutes before beginning fit testing to allow the particle count to stabilize. The generator must operate in an upright position at all times. One reservoir full of salt solution will last from 8 to 16 hours, depending on the generator setting. The salt solution can be saved and re-used. Do not mix old solution with fresh solution. To mix new solution, first discard whatever remains in the reservoir. To re-use the solution, detach the reservoir from the generator, cover it tightly with the temporary cover, and store it in its designated space inside the carrying case. C a u t i o n Never attempt to store the particle generator in the carrying case with a full or partially-filled reservoir attached, as the solution will leak out and damage the generator and/or carrying case. Setting Up and Operating the Model 8026 Particle Generator 5

Operating the Model 8026 Particle Generator The Model 8026 particle generator operates without intervention once the power is turned on. To increase particle concentration, adjust the output adjustment screw. Adjusting the Particle Generator Output The Model 8026 is set in the factory to a normal operating pressure. This will produce an aerosol output concentration that is appropriate for most environments. If higher counts are needed, increase the output by turning the output adjustment screw clockwise 1/2 turn. If necessary, adjust the output further by making additional turns of the output adjustment screw. See Figure 2-3. Output Adjustment Screw Increase Figure 2-3 To restore the output to the factory setting, turn the screw completely clockwise to maximize the aerosol flow. Then, make three (3) complete counterclockwise turns. The screw should turn easily. Do not force it. Alternate Uses for the Particle Generator The Model 8026 Particle Generator may be used as a generalized source of poly-disperse particles in an environment. When used for other applications, the following precautions must be observed: The output of the generator may be directed to a specific location by attaching a short ¼ ID tube to the output located on the top. The tubing must be kept as short as possible, no longer than 24. The tubing creates a pressure drop which will severely limit the generator output. The adjustment screw may be used to increase the generator output to the maximum to compensate for the particle loss. 6 Chapter 2

Chapter 3 Maintenance Routine Maintenance The Model 8026 Particle Generator requires very little maintenance. Cleanliness is the single most important maintenance requirement. To ensure trouble-free operation of the generator, do the following: Use compressed air to blow out accumulated salt from inside the generator case. Blow air into the louvers located on the back of the generator to clean salt from the cooling fan. Blow air into the bottom of the generator through the cooling louvers. C a u t i o n This cleaning maintenance step is critical to maintaining trouble-free operation of the generator. Wipe up any salt solution spills immediately. Periodically wipe down the outside surface of the generator using a damp cloth. After each use, shut off the generator, remove the salt solution reservoir, and then switch the generator back on for 40 seconds. This will purge salt solution from the unit and reduce contamination of the carrying case. No other routine periodic maintenance is required. If a decrease in output is noticed, clean the atomizer nozzle by following the procedure below. Cleaning the Atomizer Nozzle 1. Turn the particle generator off. Remove the salt solution reservoir. 2. Disassemble the atomizer jet assembly following the order indicated in Figure 3-1. The retainer that holds the parts of the jet together can be difficult to remove. If necessary, use pliers to pull down on the tab with a gentle rocking motion. The jet assembly incorporates one small O-ring. Set it in a safe place. 7

5 4 3 2 1 Figure 3-1 3. Use mild soap and warm water to clean the jet assembly parts. Examine the orifice for plugging. Rinse a second time if necessary. Either use clean compressed air to dry the parts, or air dry them. Note: The orifice is easily damaged. Do not insert anything in the orifice in an attempt to clean it. 4. Reassemble and install the atomizer jet, making sure to replace the O-ring. When replacing the retainer, make sure it is pushed in completely. 5. Attach the draw tube. 6. Test the generator for proper operation (output) using clean tap water. 8 Chapter 3

Chapter 4 Troubleshooting This chapter describes the symptoms, possible causes and recommended solutions for common problems encountered with the Model 8026 Particle Generator. Some common problems that could be encountered include: Symptom Possible Cause Corrective Action Low particle counts Low particle counts (cont.) No aerosol output The particle generator is not running. The salt solution is mixed incorrectly. The salt solution reservoir is low or empty. The atomizer head on the particle generator is clogged. The particle generator pressure is set too low. Salt solution may not be suitable for room. The testing room is inappropriate. It is too large It is not a closed room It has too high an air exchange rate The compressor does not start when turned on. (Red light comes on okay). Turn on the power to the particle generator. Refer to the mixing instructions in Chapter 2. Mix a new batch of solution and fill the reservoir. Clean the atomizer head. Refer to the maintenance procedure in the previous chapter. Adjust the pressure to a higher setting, as necessary. Refer to the procedure in Chapter 2. Add 1 or 2 additional tablets of salt to mixture. Or move particle generator closer to PortaCount fit tester. Do NOT locate closer than 4 ft. from PortaCount fit tester. If the room is too large or not closed, select another location. If the air exchange rate is too high, increase the output of the particle generator. Return the generator to TSI for servicing. 9

(This page intentionally left blank) 10 Chapter 4

Appendix A Specifications The Model 8026 Particle Generator specifications are as follows. Specifications are subject to change without notice. Size... Weight... Generated Particle Statistics (using 2% NaCl solution in distilled water) Count median diameter (CMD)... Geometric standard deviation (GSD)... Operating Voltage... Warranty... 10 in. x 4 in. x 5.25 in. (25.4 cm x 10.1 cm x 13.3 cm) 2.75 lb (1.25 kg) 0.04 micrometers (nominal) 2.2 (nominal) 115 or 230 VAC (check label on unit) One year on workmanship and materials 11

TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 P/N 1980319 Rev M 2016 TSI Incorporated Printed in U.S.A. *1980319*