Equivital Wireless Physiological Monitoring



Similar documents
SMS GSM Alarm Messenger

LIGHTNING. Key Features :: Cellular (UMTS/GSM) Sensors. Iridium SBD. Power. Physical Features

Home Passport Gateway Series Simplify your Life with Smart Solutions

Temperature & Humidity SMS Alert Controller

SUUNTO COMFORT BELT Heart Rate Transmitter Belts USER GUIDE

VitalJacket SDK v Technical Specifications

VitalJacket SDK v Technical Specifications

Data Loggers for Real Time Temperature Monitoring - WiFi

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Mirador. Features include: Applications:

Affordable Real-Time Monitoring

Wireless. Secure. MobileLink wireless ECG communication

GPS/SMS/GPRS TRACKER TK103A VEHICLE CAR REALTIME TRACKING DEVICE SYSTEM

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Continuous, remote monitoring and logging of electromagnetic fields

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

No. S8351. S8351 External Bluetooth module for mz series transmitter OPERATING INSTRUCTION

IEEE /ZigBee USB Dongle

Nardalert S3 Non-Ionizing Radiation Monitor

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

USER GUIDE. Access to the Server is via the following webpage:

1. INTRODUCTION TO SUUNTO SMART BELT 2. GETTING STARTED WITH SUUNTO SMART BELT

WUA Mbps Wireless USB Network Adapter

Cloud Traveler. Manual. Portable Wireless Router/Hotspot APP

IN-OUT Thermometer with Cable Free Sensor and Clock

Wireless Medical Telemetry Laboratory

A-307. Mobile Data Terminal. Android OS Platform Datasheet

WIRELESS INSTRUMENTATION TECHNOLOGY

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

PREFACE SUMMARY. Mobile Network (GPRS) communication established. No power to the unit or the unit cannot start

COFDM Transmission systems

Vesta Visual Verification Alarm System - MJ Series. Keeping Home in Sight on Your Smartphone

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Keeping your goods safe and you in control.

GPS Vehicle and personal location tracker. User manual

Industrial IOT Gateway Family Datasheet

Wireless Patient Monitoring

SpO2 PULSE OXYMETER MD-300

Installer Guide smart connect

GeoMax GNSS Zenith10 & Zenith20 Series

HidnSeek Tracker Solution: Standalone GPS Tracker ST- 1A

Atomic Projection Alarm with Indoor and Outdoor Temperature

Smart Anytime, Safe Anywhere. Home Passport Gateway-G Series. The Epitome of Smart Living

Vehicle IOT Gateway Family Datasheet

Revolutionizing Your Way of Life

Long Distance Industrial Wireless Transmitters and Receivers

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Premium Server Client Software

Remote Monitoring of Livestock Wireless and the Wii Improving Livestock Welfare

RF Projection Barometer With Remote Thermo Sensor

PhysioDroid: an app for physiological data monitoring

USB GSM 3G modem RMS-U-GSM-3G. Manual (PDF) Version 1.0,

World Food Programme. Grasp Manual. An Overview

Disclaimers. Important Notice

The Ultimate solution for SVR and Fleet Management applications

Products & Services.

New Customer Activation Guide for Sprint-Nextel Customers

Design and Development of a Wireless Remote POC Patient Monitoring System Using Zigbee

Wireless Data Logger Monitoring Systems

ewon Flexy 3G GSM Extension Card FLB P3202 Installation Guide

TD-8610/TD-8610B External ADSL2+ MODEM

PRODUCT CATALOG. Data Loggers External Sensors Software Accessories

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Skyus 3G. Quick Start Guide Verizon

510(k) Summary May 7, 2012

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Managing Your Hospital RF Spectrum

2.4G Bluetooth Datalink & ipad Ground Station User Guide V1.02

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

HOME ALARM MONITORING NETWORK GOH SWEE TIAN

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

FT-1000/GPS-N. System of remote monitoring and control of physical

A-317. Mobile Data Terminal. Android Platform Datasheet

750Mbps ac Wireless Broadband Router

HWg-STE HWg-STE PoE MANUAL

Novel AMR technologies and Remote Monitoring

Transponder for GainMaker Amplifiers

Reti wireless in banda ISM e complementarieta con le reti cellulari

All Products of MEDIANA. All because of you,mediana will be better...

DLB 5-20 Outdoor Wireless Device DATASHEET. COPYRIGHT 2014 LigoWave

INTRODUCTION TO NETGUARD

Wireless Multi-Mode AP Router. AP Only. WDS Repeater. WDS Only. Adapter WAN. Port LAN LAN

Vehicle Tracking and OBD Information

Connected. Philips HeartStart connectivity and data management for ALS professionals

Operation Error Management

User guide. SmartWatch MN2

Wi-Fi handheld microscope for use with the Apple iphone, ipod touch, or ipad.*

Pad. Quick Start Guide

Wireless Bluetooth Mouse User s Guide

OptiView XG Network Analysis Tablet - Wireless Version The tablet for WiFi network engineers and integrators

Point of View Mobii 10 Tegra Tablet. Notice... 2

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

PRO 5000 CPE 1D Quick Installation Guide

AC 750. Wireless Dual Band 4G LTE Router. Highlights

User Guide TL-POE150S PoE Injector

Transcription:

Equivital Wireless Physiological Monitoring Physiological Monitoring Solutions for Field and Laboratory Based Human Performance Research

Physiological Monitoring Solutions for Effective Human Performance Research Equivital - Advanced Physiological Monitoring The Equivital System is a complete human physiological monitoring platform, suitable for both laboratory based and field research. Incorporating proprietary, patented algorithms, the system delivers noise-free, live physiological data suitable for review by medical personnel. This cutting edge technology combines the measurement of human physiology with human movement using an integrated tri-axis accelerometer. It is also the only medically approved, multi-parameter, ambulatory monitoring system capable of measuring core body temperature. Core Platform Overview The core Equivital system comprises the EQ-01 monitoring unit, communications element and data viewing and analysis tools. PARAMETERS MEASURED Heart rate 2 lead ECG Respiratory rate and effort Skin temperature Movement and body orientation OPTIONAL SENSORS Core body temperature Oxygen saturation Galvanic skin response Geo-location The Monitoring Unit The Equivital Sensor Electronics Module (SEM) weighs just 75g, is robust and water resistant. The SEM processes the wearer s vital signs and transmits them via a Class 1 Bluetooth interface. The Equivital monitoring belt features a system of sensors and electrodes which connect with the Sensor Electronics Module. Data Communication & Viewing Data can be viewed in real time and retrospectively by recording data to the EQ-01 device memory. For real time use, the device can be configured to transmit physiological data continuously or at set intervals. Equivital offers two proprietary PC software viewing platforms - Equivital LiveLink Console & Equivital Explorer - and a PDA or mobile phone based viewing software, Pocket EQ-View. Equivital EQ-01 Physiological Monitor Equivital LiveLink Console Equivital LiveLink Console enables viewing of multiple data sets in both waveform full disclosure mode and summary partial disclosure mode. Equivital Explorer Equivital Explorer is a windows based platform which enables web based viewing of summary partial disclosure data and GPS based location during outdoor research activities. EqViewer7p11 - Agilent VEE Pro Run Time ECG 1 X1 ECG 2 X1 RESP X1 VERT 451 HORI 546 LAT 501 Not For Clinical Use LiveLink Console BELT SENSOR ID / PWI Prone Stat LIVE Batt OK Fall Confirmed CONF. 3408017 Leads OK Rates Off 84% Belt OK << SELECT DEVICE >> Comms Equivital_3408017 Sat. OK STOP File: Equivital_34080 HR (bpm) 86 SQ 100% Conf 94% HR_SpO2 (bpm) 86 SpO2 (%) 99 BR (bpm) 14.8 SQ EDR bpm SQ 100% TEMP. TEMP. Skin Skin 30.3 C 90% QI(all) 90% IMPEDANCE bpm 14 15 SQ 100% C Core _ 37.0 C S/No DTR1 x Equivital System Developers Kit For integration into a wider system, the Equivital Systems Developers Kit enables the development of custom software platforms.

Equivital Laboratory System Configuration 1 Equivital LiveLink Console Laboratory Research System for up to 5 users employing a direct Bluetooth Class 1 connection 5 Bluetooth Class 1 Link (Up to 100m range) PC operating LiveLink Console software and Bluetooth Class 1 interface adaptor 1 Equivital LiveLink Console Laboratory Research System for up to 21 units employing an Equivital Communications Hub 21 Bluetooth Class 1 Link (Up to 100m range) Equivital Communications Hub PC operating Live Link Console software System Features LIVE VIEWING Multiple live data stream viewing capability The Laboratory Research Equivital system can offer real time data views from up to 21 people wearing Equivital EQ-01 monitoring units by using an Equivital Hub. Multiple Equivital Hubs can also be networked to view data from more than 21 subjects. In this arrangement both Full Disclosure live waveform and Partial Disclosure summary data can be viewed using the Equivital LiveLink software platform. Live Alerts Equivital offers the ability to set limits for alerts or alarms for each recorded parameter. An individual alert will be displayed on the live screen. Welfare Index The system features a physiological welfare index which uses predefined parameter limits to create a contextual welfare alarm based on the wearer s physiology and movement. DOWNLOADING DATA AND RETROSPECTIVE VIEWING Internal Memory of the EQ-01 Device Each Equivital EQ-01 device has an integral 2Gb micro SD memory card. This is sufficient for continuous full disclosure data to be recorded for a period of approximately 10 days. Data Download and Export Data can be exported as a CSV file for further manipulation in a spreadsheet or database application. The data is time-stamped using an integrated real time clock.

Equivital Outdoor System Configuration Equivital Outdoor Research System employing Equivital Gateway ISM Radio or GSM Communications Equivital Gateway Radio Summary Physiology Data and Geo-Location via ISM Band Radio RF Modem Internet / Intranet PC s operating Equivital Explorer software Bluetooth Personal Area Networks Relay Devices GSM Modem Summary Physiology Data and Geo-Location via SMS Server GPS Enabled Personal Device (Windows Mobile) Local Observation Point System Features FLEXIBLE COMMUNICATIONS CAPABILITY Multiple Radio Interfaces The Equivital Outdoor Research system has a multifaceted communications capability which includes GSM, TETRA, Tactical Military Radio (with customisation option for near field communications as part of roll out of multiple systems) and a proprietary Equivital Gateway Radio Solution. Equivital Gateway Equivital Gateway is a convenient field radio communications system enabling the physiology measurements of multiple subjects to be monitored. The Gateway personal radio unit is linked to the subjects Equivital unit via Bluetooth and operates on ISM band radio (2.5GHz or 900MHz) at a range of up to 5Km, depending upon environment and terrain. An optional 10m field mast and antenna system is available to ensure maximum area coverage. LIVE VIEWING Multiple Live Data Stream Viewing Capability and integrated Geo-Location The Equivital Outdoor Research system can use the Equivital Explorer software to provide the user with live physiological data integrated with geolocation. This is enabled by each Equivital EQ-01 unit being associated with a variable GPS data feed. Web Based Viewing Platform The web based Equivital Explorer Platform enables multiple users to remotely view real time data. Example; Live monitoring of individuals taking part in a running event. Each individual would carry a GSM enabled device e.g. mobile phone with Pocket Eq-View software installed on it. Summary Message Data The system allows summary data to be viewed at time intervals which are set by the user or can be configured to only send data when there is an alert. Live Alerts Equivital offers the ability to set alert or alarm limits for each recorded parameter. An individual alert will be displayed on the live screen. Welfare Index The system features a physiological welfare index which uses predefined parameter limits to create a contextual welfare alarm based on the wearer s physiology and movement. Trends The live Equivital Explorer viewer allows trends data for each EQ-01 device connected to the system to be displayed in real time, with annotated time stamps.

EQUIVITAL TECHNICAL SPECIFICATIONS SYSTEM MEMORY Internal memory 2Gb micro SD INTERFACE Interface Class 1 Bluetooth (100m) Data Communications Integration with Equivital Communications Hub, Gateway ISM radio system or personal communications device POWER SUPPLY Power source 2 x 1.5v AAA LR03 Alkaline cells or 3.7V 740mA Li-ION rechargeable cell (Recharge Time: From Flat 1hr) PHYSICAL Weight Operating temperature Operating Humidity Storage Temperature Storage Humidity Environmental Protection SEM - 75g -10 C to +55 C 0% to 95% RH Non-Condensing -20 C to +65 C 0% to 95% RH Non-Condensing IP67 (0.4m/30mins) APPROVALS Approvals CE Certified Device Safety EN60601-1 Classification Shock Protection: Type BF Applied Part, Internally Powered Equipment Mode of Operation: Continuous FDA Device Classification: Class II EU Device Classification: Class IIb FCC Part 15 This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) these devices must accept any interference received, including interference that may cause undesired operation. Type 0 Radio Interface: Type 1 Radio Interface FCC ID: T85 EQ001 FCC: QOQWT11

Hidalgo Limited 20 Market Street, Swavesey, Cambridgeshire, CB24 4QG, UK Tel: +44 (0)1954 233430, Fax: +44 (0)1954 233431, E: info@equivital.co.uk www.equivital.co.uk A Jaltek Group Company Copyright Hidalgo Limited. All rights reserved. All other company and product names maybe trademarks of their respective companies. While every effort is made to make sure the information shown is accurate, Hidalgo does not accept any liability for any errors or mistakes that may arise. Specifications and other information may be subject to change without notice. All performance figures and other data contained in this document may vary by application. HIDA1224_BRO_11_1_EQ01 Research