674 Rain Gauge. Installation and Operation Guide



Similar documents
Tipping Bucket Rain Gauge Models 6011-A 6011-B

581 Rapid Transfer Device (RTD) Instruction Manual. Photo of product, with a.5 point black border

Global Water Instrumentation, Inc.

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Advantium 2 Plus Alarm

Installation Instructions

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Data-Logging Rain Gauge PRODUCT MANUAL

Single Station Remote Alarm

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Industrial Ringdown/Autodialer Telephone SCR Series

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Model Owner s Manual. Español - P. 19 Français - P. 39

Mini Power Bank and Charger

FLEX by 3M Light Module System

Model 201 Wiegand Touchpad Reader Installation Guide

Global Water Instrumentation, Inc.

Wireless Indoor/ Outdoor Thermometer

Weatherproofing Coaxial Cable Connections

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

12-Volt Negative Ground Installation Instructions

, User s Manual

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Toroidal Conductivity Sensor

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

PEDAL POWER. User s Manual

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Installation Manual DIAPHRAGM WELL TANK

Model 450 Mag Horn Ferromagnetic Locator

Global Water Instrumentation, Inc.

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

5800 Temperature Sensor Cable Assembly

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

12 Volt 30 Amp Digital Solar Charge Controller

CHAPTER 1. GETTING STARTED... 1

TABLE OF CONTENTS 11.0 WARRANTY

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

INSTALLATION & OPERATION MANUAL LED

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

MODEL # Introduction

12-Volt 10-Amp Regulated Power Supply

Installation and Operating Instructions (for chargers shown below)

RT-200 HI-TEST ROPE TESTER

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

MODEL G300 BRAKE BLEEDER

Universal Laptop Charger

Installation and Operation Guide for PD4000 Series Power Control Center

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

User Guide. HDMI Active Cable Extender. DVI-7370c

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

Utility Distribution Systems

Operating Manual Color Changing Fountains

ClearView 100. Instruction Manual

STC 3S A Series Solenoid Valves

Installation and Operation Guide for PD4100 Series Power Control Centers

LCD5500Z / PKP-LCD v3.x Installation Instructions

This product has the equivalent gain performance with the 14 element Yagi antenna.

Ozone Generator Manual

USER MANUAL. Rain Collector. with Mountable Base. Product numbers 7857 and 7857M

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

NFC Communication Tray Model: HHX-IT3-Z

Canopy Surge. User Manual

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Remote Alarm Monitoring System

8-Ohm Ceiling Speakers For Music and Home Theater

3 WATT LED SPOTLIGHT Model No. SLM

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Instructions and precautions. Fork Height. Visit our website at:

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

SingleNet Single Cable Control System

Wooden Shipping Crate is Available to Protect Your UV Light Source. 11 X " diameter tubes 120 VAC Amps Watts

Seven function digital multimeter

User and Installation Guide

ANT1750F Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION & OPERATION MANUAL

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

Transcription:

Installation and Operation Guide Part #60-3283-011 Copyright 1992, 2004. All rights reserved, Teledyne Isco, Inc. Revision J, April 18, 2011

Foreword This instruction manual is designed to help you gain a thorough understanding of the operation of the equipment. Teledyne Isco recommends that you read this manual completely before placing the equipment in service. Although Teledyne Isco designs reliability into all equipment, there is always the possibility of a malfunction. This manual may help in diagnosing and repairing the malfunction. If the problem persists, call or e-mail the Teledyne Isco Technical Service Department for assistance. Simple difficulties can often be diagnosed over the phone. If it is necessary to return the equipment to the factory for service, please follow the shipping instructions provided by the Customer Service Department, including the use of the Return Authorization Number specified. Be sure to include a note describing the malfunction. This will aid in the prompt repair and return of the equipment. Teledyne Isco welcomes suggestions that would improve the information presented in this manual or enhance the operation of the equipment itself. Teledyne Isco is continually improving its products and reserves the right to change product specifications, replacement parts, schematics, and instructions without notice. Contact Information Customer Service Phone: (800) 228-4373 (USA, Canada, Mexico) (402) 464-0231 (Outside North America) Fax: (402) 465-3022 Email: IscoCSR@teledyne.com Technical Support Phone: (800) 775-2965 (Analytical) (866) 298-6174 (Samplers and Flow Meters) Email: IscoService@teledyne.com Return equipment to: 4700 Superior Street, Lincoln, NE 68504-1398 Other Correspondence Mail to: P.O. Box 82531, Lincoln, NE 68501-2531 Email: Web site: IscoInfo@teledyne.com www.isco.com Revised March 17, 2009

Table of Contents 1.1 Description and Operation............................................ 1-1 1.2 Applications........................................................ 1-1 1.3 Materials and Construction........................................... 1-1 1.4 Location of the Rain Gauge........................................... 1-2 1.4.1 Suggested Siting.............................................. 1-2 1.5 Installation........................................................ 1-2 1.6 Maintenance....................................................... 1-3 1.7 Electrical Considerations............................................. 1-4 1.8 Technical Specifications.............................................. 1-5 1.9 Replacement Parts List............................................... 1-5 List of Tables 1-1 Technical Specifications for the 674 Rain Gauge.......................... 1-5 List of Figures 1-1 Replacement Parts List Illustration.................................... 1-6 1-2 Replacement Parts List.............................................. 1-7 i

Table of Contents ii

1.1 Description and Operation The Isco 674 Rain Gauge is a precision instrument for accurately measuring rainfall. The rain gauge is mounted inside a steel cylinder and has an eight-inch opening on top to collect rain. Rain falls through a screen into a funnel. From the funnel, rain collects in one side of a two-chambered plastic bucket mounted on jewelled pivots. When rain fills the chamber, the bucket tips, draining the water and exposing the other chamber to fill. When that chamber fills, the bucket tips back and the process begins again. Each time the bucket tips from one side to the other, a magnet passes over a reed switch, momentarily closing the normally open contacts. This contact closure provides a short-duration output pulse from the rain gauge for each 0.01 inch of rain. 1.2 Applications When connected to a flow meter, the rain gauge enables the flow meter to print rainfall data on its chart or store rainfall data in memory. It also lets the flow meter actuate an associated Isco Automatic Wastewater Sampler. Typical applications include monitoring of storm water runoff, inflow and infiltration studies (I&I), and combined sewer overflow monitoring. You can also use the rain gauge for any other general purpose rainfall measurement as long as the associated equipment is electrically compatible. 1.3 Materials and Construction The rain gauge is constructed of steel, stainless steel, aluminum, and plastic. All metal parts are coated, plated, or painted to ensure a durable, ruggedly tough instrument capable of resisting deterioration from exposure to the elements. Screens cover all openings, preventing clogging by leaves, insects, or other debris. The powder-coated steel sleeve protects the internal parts. The jewelled-pivot mounting for the tipping bucket provides long life. A built-in bubble level makes leveling the rain gauge after installation easy. A 50-foot cable terminated in an M/S connector attaches the rain gauge to the flow meter or to other equipment. CAUTION The rain gauge is factory-calibrated and adjusted. Do not attempt to make any adjustments to the jewelled-pivot screws. You may damage the jewel bearings. 1-1

1.4 Location of the Rain Gauge Location affects the accuracy of the rainfall catch because the prevailing winds may tend to carry the rain away from the gauge. There are advantages and disadvantages to most sites. Sites may be either open or protected. Totally open sites affect the accuracy of the catch if the rain is carried on strong winds, but are satisfactory if rainstorms are generally calm. With no nearby vegetation the characteristics of the site will not tend to change over time, which is an advantage. Where strong winds are characteristic of storms, protected sites are generally preferable. This is because the effect of the wind on the rainfall catch is reduced. The presence of small groups of objects or objects of varying heights around the gauge can also affect accuracy by producing eddy currents in the wind which will interfere with the catch. 1.4.1 Suggested Siting Groups of objects of uniform height (such as trees) in the vicinity of the gauge are beneficial for an accurate catch by acting as a windbreak while not interfering with the catch. Mounting the rain gauge in the clearing of an orchard or a grove of trees would be a recommendation for a good site. The height of the surrounding objects should not exceed twice their distance from the rain gauge. If vegetation serves as a windbreak, understand that growth will greatly change the conditions of the site with the passage of time. What may originally have been a good site may not always remain one. Vegetation grows dramatically over time. Any construction nearby that takes place after the installation may also make a site undesirable by altering the wind currents and rainfall patterns around the gauge. Under no circumstances should any nearby object be allowed to grow above or hang directly over the gauge. The rain gauge is solidly built to withstand years of outside use; however, vandals could ruin it. Always try to install the rain gauge where it will be protected from vandalism. Avoid installation in low places where runoff from heavy storms could flood the gauge or wash it away. The rain gauge would not be hurt by submersion, but it would be unable to measure. Do not drop the rain gauge or expose it to shock; that could damage the jeweled bearings. 1.5 Installation To install the rain gauge, follow the procedure below. Step 7 is optional, depending on the requirements of your particular installation. 1. Unpack the rain gauge from the shipping box. Save the box and packing to return the rain gauge to Isco if that becomes necessary. Remove the outer tube (white cover with funnel) from the rain gauge by loosening the two thumb screws on either side. 2. Locate the bottom (mounting) plate of the rain gauge. This is circular and made of black metal. Mount this plate securely to a stable horizontal surface that is relatively 1-2

level. Isco suggests using corrosion-resistant hardware for mounting. The mounting holes will accommodate hardware as large as ¼ inch in diameter. 3. This is very important: Level the rain gauge by adjusting the three thumb screws on the base until the bubble in the bubble level is exactly centered. 4. Carefully remove the rubber band used to secure the tipping bucket assembly. Do not apply pressure to the bucket or the pivot arm. Do not attempt any adjustments. 5. Reinstall the protective outer tube on the rain gauge. 6. Route the cable from the rain gauge to the flow meter. Coil any extra wire by the flow meter. 7. If necessary, you can increase the distance between the flow meter and the rain gauge to 1,000 feet (maximum) by splicing a two-wire #18 AWG cable (user- supplied) between the Isco-provided cable and the rain gauge, as described below. Disconnect the Isco cable from the terminal block inside the rain gauge and splice the user-supplied cable to that end of the Isco cable. If the wiring and the splice will be exposed to the weather, use wire appropriate for outdoor use and insulate the splice properly. A weatherproof box may be necessary. Do not cut the M/S connector from the Isco cable unless you are connecting the rain gauge to equipment that does not have a compatible connector. You will not be able to reconnect it easily. 1.6 Maintenance The Isco Rain Gauge is built of quality materials to withstand years of exposure to the elements. Normally, no maintenance is required. Once a year (or more often if conditions warrant) you may want to remove the cover and check the gauge to see that it has not been affected by the buildup of dust, debris, or insect infestation. The rain gauge is factory-calibrated and needs no further adjustment. If your installation is temporary and you intend to move the rain gauge from site to site, use care in transporting the unit. Again, you could damage the jewelled pivots for the tipping bucket if you expose the rain gauge to a severe shock - for example, by dropping it. If you move the rain gauge frequently, always secure the tipping bucket with a rubber band and use the original packing box to protect the unit during transport. Repack the rain gauge as it was originally shipped to you if you need to return it to Isco. 1-3

1.7 Electrical Considerations The electrical output from the Isco Rain Gauge is the rapid contact closure of a normally open reed switch. The rain gauge is not itself a powered device. It contains neither batteries nor transformer and does not connect to the AC line. Electrically, it is a dry contact switch, with power supplied from whatever device it controls. When you connect the rain gauge to an Isco Flow Meter, the current through the switch contacts is very low and there is no problem with line losses or damage to the switch contacts. However, if you plan to use the rain gauge for general-purpose rain measurement with other types of equipment not specified by Isco, please note the following: CAUTION The reed switch is rated for pilot duty only! The sealed contacts are limited to 10 watts (or 10 VA), 200 VDC maximum. Exceeding these limits may cause welding or rupturing of the reed switch, ruining it. For safety considerations, Isco recommends connection only to equipment supplying 30 volts or less, AC or DC. Be particularly careful using the rain gauge with equipment supplying DC voltages at higher current loads or equipment presenting an inductive load to the reed switch. Never connect the rain gauge directly to any equipment where enough current passes to strike an arc when the contacts switch. You should always buffer such equipment with a solid-state switch (transistor, IC, SCR, etc.) or a sensitive relay. 1-4

1.8 Technical Specifications The technical specifications for the 674 rain gauge are presented in Table 1-1. Type: Orifice: Sensitivity: Accuracy: Maximum Capacity: Connector Pinout: Output Signal: Switch Type: Height and Diameter: Weight: Table 1-1 Technical Specifications for the 674 Rain Gauge Tipping bucket 8 inches (20 cm) diameter English: 0.01 inches Metric: 0.1 mm English: ± 1% at 2 inches/hr; +3, -4% up to 5 inches/hr Metric: ± 1½% at 5 cm/hr; +3.5, -9% up to 13 cm/hr English: 22 inches/hr Metric: 38 cm/hr Pin A - Red, +12V DC from Flow Meter; Pin D - Black, Output from Rain Gauge Contact closure, 50 milliseconds minimum duration Hermetically sealed magnetic reed switch. Normally open. 200V DC, 0.5 A maximum 13 inches (33 cm); 9½ inches (24 cm) at base 10 pounds (4.5 kg) Operating Temperature: 32 to 140 F (0 to 60 C) Storage Temperature: -40 to 140 F (-40 to 60 C) 1.9 Replacement Parts List The following pages contain a list of replacement parts for the Isco 674 rain gauge. The illustration shows the location of the numbered parts, which are described in the accompanying table. Replacement parts can be purchased by contacting Isco s Customer Service Department. Isco, Inc. Customer Service Department P.O. Box 82531 Lincoln, NE 68501 USA Phone: (800) 228-4373 (402) 464-0231 FAX: (402) 465-3022 E-mail: info@isco.com 1-5

Figure 1-1 Replacement Parts List Illustration 1-6

Figure 1-2 Replacement Parts List 1-7

1-8

Warranty Teledyne Isco One Year Limited Warranty* Factory Service for Teledyne Isco Flow Meters, Waste Water Samplers, and Syringe Pumps This warranty exclusively covers Teledyne Isco instruments, providing a one-year limited warranty covering parts and labor. Any instrument that fails during the warranty period due to faulty parts or workmanship will be repaired at the factory at no charge to the customer. Teledyne Isco s exclusive liability is limited to repair or replacement of defective instruments. Teledyne Isco is not liable for consequential damages. Teledyne Isco will pay surface transportation charges both ways within the 48 contiguous United States if the instrument proves to be defective within 30 days of shipment. Throughout the remainder of the warranty period, the customer will pay to return the instrument to Teledyne Isco, and Teledyne isco will pay surface transportation to return the repaired instrument to the customer. Teledyne Isco will not pay air freight or customer s packing and crating charges. This warranty does not cover loss, damage, or defects resulting from transportation between the customer s facility and the repair facility. The warranty for any instrument is the one in effect on date of shipment. The warranty period begins on the shipping date, unless Teledyne Isco agrees in writing to a different date. Excluded from this warranty are normal wear; expendable items such as charts, ribbon, lamps, tubing, and glassware; fittings and wetted parts of valves; and damage due to corrosion, misuse, accident, or lack of proper maintenance. This warranty does not cover products not sold under the Teledyne Isco trademark or for which any other warranty is specifically stated. No item may be returned for warranty service without a return authorization number issued by Teledyne Isco. This warranty is expressly in lieu of all other warranties and obligations and Teledyne Isco specifically disclaims any warranty of merchantability or fitness for a particular purpose. The warrantor is Teledyne Isco, Inc. 4700 Superior, Lincoln, NE 68504, U.S.A. * This warranty applies to the USA and countries where Teledyne Isco Inc. does not have an authorized dealer. Customers in countries outside the USA, where Teledyne Isco has an authorized dealer, should contact their Teledyne Isco dealer for warranty service. Before returning any instrument for repair, please call, fax, or e-mail the Teledyne Isco Service Department for instructions. Many problems can often be diagnosed and corrected over the phone, or by e-mail, without returning the instrument to the factory. Instruments needing factory repair should be packed carefully, and shipped to the attention of the service department. Small, non-fragile items can be sent by insured parcel post. PLEASE BE SURE TO ENCLOSE A NOTE EXPLAINING THE PROBLEM. Shipping Address: Teledyne Isco, Inc. - Attention Repair Service 4700 Superior Street Lincoln, NE 68504 USA Mailing Address: Teledyne Isco, Inc. PO Box 82531 Lincoln, NE 68501 USA Phone: Repair service: (800) 775-2965 (lab instruments) (866) 298-6174 (samplers & flow meters) Sales & General Information: (800) 228-4373 (USA & Canada) Fax: (402) 465-3001 Email: IscoService@teledyne.com March 8, 2011 P/N 60-1002-040 Rev E