DCS data and communication server



Similar documents
DCS Data and communication server

DCS Data and Communication Server

Data Sheet Fujitsu ESPRIMO P2440 Desktop PC

Cisco 7816-I5 Media Convergence Server

TrueAlarm Fire Alarm Systems

Scout 1U Rackmount Computer

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

Box PC Fanless. Box PC Performance

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

Panel PC SIMATIC HMI IPC577C

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Chapter 5 Cubix XP4 Blade Server

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

DMS-10101, Computer Equipment

Application Server V240 Platform

Cisco MCS 7825-H2 Unified CallManager Appliance

Cisco MCS 7816-I3 Unified Communications Manager Appliance

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Acer AT110 F2 Specifications

AXIS 262+ Network Video Recorder

QuickSpecs. HP 285 Pro G1 Microtower Business PC. Overview

Phone and Fax: (717) or Send to- On the Internet at

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500

TX OPEN RS232/485 module

Fujitsu ESPRIMO P2560 Desktop PC

Display units With alphanumeric screen

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power

2100 POS System User Guide

Data Sheet. Workstation. The new uncompromising high-end workstation. Windows. Life without Walls. Fujitsu recommends Windows 7.

QuickSpecs. HP 280 G1 Microtower Business PC. Overview

Artikel-Detailinformationen

FUJITSU Enterprise Product & Solution Facts

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Artikel-Detailinformationen

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

Minimum Hardware Specifications Upgrades

Datasheet. Workstation

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

Local PlantVisor. PlantWatch. Remote PlantVisor

Secu6 Technology Co., Ltd. Industrial Mini-ITX Intel QM77 Ivy Bridge Mobile Motherboard Support 3 rd Generation Core i7 / i5 / i3 Mobile Processor

1. Desktop Systems: Given below is the clarification and suggested changes.

HMI display Installation Guide

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor

Embedded & Industrial PCs International Products and Configurations INDEX

Product Specifications. Shuttle Barebone D10. Shuttle Mini-PC with 7" Touchscreen. Feature Highlight.

Data Sheet Fujitsu ESPRIMO P2760 Desktop PC

NDNA Desktop Price List


OZW30. Central Unit SYNERGYR

QuickSpecs. HP Compaq t5525 Thin Client. Overview

PCS0100en Persy Control Services B.V. Netherlands

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

ACER INC. VERITON M200 QUICK SPEC

ROSA Server MKVI. A Complete, Powerful Solution

Ultra Thin Client TC-401 TC-402. Users s Guide

Data Sheet ESPRIMO P3510. Your flexible economic PC ESPRIMO P3510

HQP-1072 Series System User Guide

COMPUTING INDUSTRIAL EMBEDDED RUGEDIZED 19 INDUSTRIE PC

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

ThinkServer TS140 - Overview

Superior PCs ESPRIMO. Windows. Life without Walls. Fujitsu recommends Windows 7. ESPRIMO P7935 E85+ Your expandable workhorse Operating system

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

7 x USB x 5V PoweredUSB on the rear panel. 2 x USB on the rear panel 2 x 5V PoweredUSB on the bottom panel

Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs

New Lenovo IdeaCentre A600 systems with Intel processor technology deliver high-performance computing at a competitive price

ZOTAC ZBOX User s Manual

WP WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller).

Fujitsu PRIMERGY BX600 S3 Blade Server

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

Rack mounted telephone- and leased line modem for industrial applications

Digital input modules

FOR IMMEDIATE RELEASE

NGSS Data Consolidator (DC)

Business PCs. Acer Veriton L410. Configuration Standard. Key Selling Points. Encore plus simple et efficace Super-écologique. Reference.

TS500-E5. Configuration Guide

NEC EXPRESS5800/R320c-E4 Configuration Guide

Light Industrial Panel PC

v1 System Requirements 7/11/07

SABRE Lite Development Kit

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

Temperature & Humidity SMS Alert Controller

SIMATIC IPC477D 1/5. Copyright Siemens AG 2014

Data Sheet Fujitsu ESPRIMO P2560 Desktop PC

Sedao Ltd. SWEP HD Digital Signage Platform Introduction

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

XP5620. Fee Computer / Validator. The new generation of touch screen Fee Computer

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

Z-TWS4. Multifunction Straton / LINUX Controller.

Brainlab Node TM Technical Specifications

Data Sheet Fujitsu CELSIUS M470 Workstation

Product Specifications Reference Lenovo ThinkServer Servers

DS-9500NI-ST Series NVR. Technical Specification

140 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

Transcription:

8 578 VISONIK DCS data and communication server PLD0.ECO/DGL PLD0.ECO/PCM Data and communication servers (DCS) are used as management station in building automation and control (BAC). With DDC technology, the DCSs as superposed system components allow for customer-specific solutions of all building automation and control tasks. Use The DCS's application range comprises a large number of building automation and control tasks such as: Process station communication at the subsystem level. Processing of acquired process data in real time. Continuous storage of selected process values (temperatures, setpoints. etc.). Monitoring of technical installations. Output of higher commands (e.g. peak load control, emergency power and network restoration). Logging of plant faults. Alarming of internal and external service organizations. Sending clear text messages based on technical plant events. Triggering reactions based on various causes: Time, date, process value changes and operating hours (maintenance). Simultaneous execution of various BAC tasks (multitasking). CM2N8578en_0 9.03.2008 HVAC Products

Presentation of process values, consumption variables, efficiency degrees and further operational and technical system information in transparent displays. Operation of system-wide BAC functions via graphical user interfaces. Connection of linked and third-party systems. Operation of building automation and control systems via networks. Type summary The PLD0-series of the DCS data and communication server consists of two hardware types with scalable software licenses (via options). Tower housing PLD0.ECO/DGL PLD0.ECO/PCM VISONIK server with USB dongle. VISONIK server with PC-M kit. Option : Number of process stations 6, 0, 5, 25, 50, 75, 00, 50, 200 Option 4: VISONIK DCS version V24 Option 6: R-server Redundant server operation System configuration Example for a VISONIK system configuration. 2/6 Building Technologies Group DCS data and communication server PLD0.ECO/ CM2N8578en_0 9.03.2008

Basic hardware The data and communication server is delivered with the following hardware components: We reserve the right to make changes to the basic hardware configuration. Computer type: PLD0.ECO/PCM Basic PC Caution: The computers are delivered without keyboard and monitor! Tower housing Mouse CPU hard drive supporting - mouse (PS/2) - keyboard (PS/2) - LAN network, 0/00/000 Mbit - COM port V.24 (9-pin) - 6 USB interfaces 2.0 (2 x front side, 2 x rear side), 2 x internal - 2 LSI SATA SW-RAID, for HDDs with RAID - I/O ports PCIe (x) - 2 I/O ports PCI 32-bit / 33 MHz - LSI SATA DVD-ROM etc. - VGA graphics board Processor / memory AMD Athlon 64 X2 4000+ (2. GHz) / GB DDR2 ECC 667 PC-M multi-function card with: - Watchdog - Radio clock - Auto reset WD - Front control panel incl. cable set Network card on main disk Equipment for connection of BLN and terminal server Storage media: 3.5 /.44 MB diskette drive DVD SuperMulti SATA 5.25/.6 inch 60 GB hard disk, not hot-plug. Computer type: PLD0.ECO/DGL Basic PC Caution: The computers are delivered without keyboard and monitor! Tower housing Mouse CPU hard drive supporting - mouse (PS/2) - keyboard (PS/2) - LAN network, 0/00/000 Mbit - COM port V.24 (9-pin) - 6 USB interfaces 2.0 (2 x front side, 2 x rear side), 2 x internal - 2 LSI SATA SW-RAID, for HDDs with RAID - I/O ports PCIe (x) - 2 I/O ports PCI 32-bit / 33 MHz - LSI SATA DVD-ROM etc. - VGA graphics board Processor / memory AMD Athlon 64 X2 4000+ (2. GHz) / GB DDR2 ECC 667 USB dongle Network card on main disk Equipment for connection of BLN and terminal server Storage media: 3.5 /.44 MB diskette drive DVD SuperMulti 5.25/.6 inch 60 GB hard disk, not hot-plug Building Technologies Group DCS data and communication server PLD0.ECO/ CM2N8578en_0 9.03.2008 3/6

Basic software The data and communication server is delivered with the following preinstalled software: Computer type: PLD0.ECO/ Windows XP Professional VISONIK software (functionality according to version and computer type) VISONIK DCS license for 6 process stations Adobe Acrobat, Nero, Acronis Options The following software and hardware components can be installed in addition to the basic installation. We reserve the right to make changes to the basic hardware configuration. PLD0.ECO/ Possible number for computer type PCIe- graphics card, 28 MB, for higher performance USB analog modem USB ISDN modem Audio card Extended memory GB 3 Order number ALD0.G28/E ALD0.ANALOG ALD0.ISDN ALD0.AUDIO ALD0.ECO/MEM Uninterrupted power supply (UPS) ALD.USV Equipment for connection of BLNs SDLC/FSK kit to operate 6 SDLC rings incl.: - PC-S card - Connection cable to SDLC plug panel - SDLC plug panel 6x25 D-sub Connection units to the SDLC rings (number) per ring; not part of delivery Connection cable to connection units (length 6m or 2 m, number per Ring; not part of the delivery) ALD0.S6/KIT 6 LVR2.432 6 6 LVR.440-E LVR.4402-E Equipment for additional interfaces: Terminal server (2 x V.24 interfaces), incl. - power supply (230 VAC / 2 VDC) - 2 adapter cables CBL-RJ45M9-50 Terminal server (4 x V.24 interfaces), incl. - power supply (230 VAC / 2 VDC) Terminal server (8 x V.24 interfaces), incl. - mains cable (230 VAC) - 4 adapter cables.5m, type CBL-RJ45M25-50 - 4 adapter cables.5m, type CBL-RJ45M9-50 - RJ45 loopback test plug - 2 mounting brackets for 9-4 rubber bases Terminal server (6 x V.24 interfaces), incl. - mains cable (230 VAC) - 8 adapter cables.5m, type CBL-RJ45M25-50 - 8 adapter cables.5m, type CBL-RJ45M9-50 - RJ45 loopback test plug - 2 mounting brackets for 9-4 rubber bases 6 4 2 ALD.TS2 ALD.TS4 ALD.TS8 ALD.TS6 Parallel card ALD0.ECO/PAR Storage media: RDX* drive for upgrades and data backup, incl. media 80 GB ALD0.RDX DAT* drive DDS-5 incl. mounting kit, 3 tapes ALD0.DAT HD 60 GB for upgrade to SW-RAID ALD0.ECO/F *) Usable only with PLD0.ECO/DGL 4/6 Building Technologies Group DCS data and communication server PLD0.ECO/ CM2N8578en_0 9.03.2008

Computer type performance features Below is a list of the performance features not obvious from the above composition of components and accessories. Furthermore, a few important VISONIK system variables are listed. Options are printed in parentheses. Computer type: PLD0.ECO/ Basic feature: Upgradeability to higher PLD types and options Yes Watchdog, reset, radio clock, control panel ** Yes SW-RAID (redundant array of independent disks) Yes Interfaces: USB plugs 6 - Serial interfaces Standard - Terminal server 2 x V.24 interfaces (RS232) - Terminal server 4 x V.24 interfaces (RS232) - Terminal server 8 x V.24 interfaces (RS232) - Terminal server 6 x V.24 interfaces (RS232) Maximum Operation: - Total number of terminals, printers and modems Standard Maximum * Maximum number of dial modems 6 Operating system languages (3) Number of access levels 5 Maximum number of concurrent users 5 System variables: Maximum number of connections for SDLC rings 6 Maximum number of process stations 200 (EKL-X, PRV, PRV2, BPS, CFE ) on BLN (SDLC, Ethernet) or via modem Addressing (alphanumeric user address), number of characters 26 Linked system: Number of VISONIK computers within linked system 20 Alarm printer for messages from various systems possible in each system Yes 3 5 9 7 2 (5) Security VISONIK computer as R-server; redundant operation of VISONIK server possible as an option via network Yes *) The maximum number of 5 messaging channels or 8 terminal channels respectively per DCS cannot be exceeded. The indicated standard characters represent a recommendation. **) Only in connection with PLD0.ECO/PCM We reserve the right to make changes to the computer configuration. Documentation See the following data sheets for information on VISONIK subsystems: BPS process station Building process station BPS/NetBPS CFE controller, PLC.00 EcuBPS CM2N8302 CM2N8306 CM2N894 CM2N8307 Building Technologies Group DCS data and communication server PLD0.ECO/ CM2N8578en_0 9.03.2008 5/6

Technical data If not mentioned specifically, the following information applies to all computer types. Power supply Mains supply PLD0.ECO/ Mains frequency Max. rated current: PLD0.ECO/ Active power 200-240 V 50-60 Hz 00 V 240 V /.5 A 0.6 A 50 W Dimensions H x W x D in mm, no plug 390 x 203 x 386 Weight PLD0.ECO/ ~ 2 kg Ambient conditions Operating temperature 0... 35 C (IEC 72) BLN data transmission System bus protocol SDLC/FSK V.24 data transmission Transmission rates for terminals, INSIGHTs, printers and modems As per specifications Network data transmission Transmission protocol Networks Rate of transmission Chip TCP/IP, NetBIOS via TCP/IP Ethernet 0/00/000 Mbps Nvidia MCP5 conformity EMC directive Low voltage guideline 89/336/EEC (EMC) 72/23 EEC (LVD) Electromagnetic compatibility Emissions Immunity EN 55022 class B; EN 55024 EN 6000-3-2 / -3 Product standard Safety of information technology equipment IEC 60950 / EN 60950 UL 60950 3rd. Ed. CAN/CSA-C22.2 No. 60950 3rd. Ed. 2008 Siemens Switzerland Ltd. Subject to change 6/6 Building Technologies Group DCS data and communication server PLD0.ECO/ CM2N8578en_0 9.03.2008