LED Lighting. Emergency LED Products. The Philips Bodine BSL Driver Family ELI-S-20 Emergency Lighting Micro Inverter ELI-S-100 Dimming Inverter

Similar documents
Linear. Emergency Operation for Linear Fluorescent Lamp Fixtures The Philips Bodine Linear Fluorescent Emergency Ballasts

Application Note: Emergency Battery Backup System (EBBS) Solutions for the XIM Platform

UNRIVALED EMERGENCY SOLUTIONS FOR LEDs CLASS 2 OUTPUT COMPLIANCE WITH AUTO-SENSE FORWARD VOLTAGE

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

LED DIMMING A HELPFUL GUIDE...

LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Lumination LED Luminaires

High Bay Occupancy Sensor Selection Guide

EMERGENCY SOLUTIONS for FLUORESCENT and LED RETROFIT LAMPS

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Flicker happens. But does it have to?

LED Tubular Lamp / Kit Guide

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Constant-Voltage vs. Constant-Current LED Drivers

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

DuroSite TM High Bay Lighting

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

Evolve LED Area Light

Welcome to this presentation on Driving LEDs AC-DC Power Supplies, part of OSRAM Opto Semiconductors LED Fundamentals series. In this presentation we

Basics of LED drivers. Functions Requirements Selection

Uninterruptible Power Supply

LED Retro Fit the next generation in energy efficiency. Converting existing 12v systems to LED

LIGHTING and LIGHTING SYSTEMS

Self Monitoring Power Supply (BPSM)

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Energy efficient lighting for your home find out more.

Understanding LED Drivers

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Contractors Guide Central Inverter System Installation

Section D..General Auto Electrical Corporation

Efficient and reliable operation of LED lighting is dependent on the right choice of current-limiting resistor

Evolve LED Area Light

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

STRATO LED Drivers 70W, Single output

PPL Electric Utilities Energy Efficiency and Conservation Program

TROUBLESHOOTING LED DOWNLIGHTS

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

User s Manual Before using the inverter, you need to read and save the safety instructions.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

7-41 POWER FACTOR CORRECTION

MAJORSINE Power Inverter

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

12 Volt Lighting Products

IPS HIGH-BAY / LOW-BAY LIGHTING

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

AND8433/D. Using ON Semiconductor Constant Current Regulator (CCR) Devices in AC Applications APPLICATION NOTE

Multi-Range Programmable DC Power Supplies 9115 Series

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Model #: SMART2200CRMXL

1.44 kw Programmable DC Power Supplies XLN Series

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Multi-Range Programmable DC Power Supplies 9115 Series

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

Tamura Closed Loop Hall Effect Current Sensors

PUCK LED 3W, 12V AC/DC REV

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Big Ass Light High Bay LED

Recessed. EvoKit LED Retrofit Kits Gen 3

DOT LED 1W, 12V AC/DC

GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work

Satcon Solstice 100 kw System Solution

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

OUTPUT CABLE CONNECTIONS:

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Stand Alone PV System Sizing Worksheet (example)

Lumination LED Luminaires

National Semiconductor Power Products - Seminar 3 (LED Lighting)

Specification Requirements DBL 700MX and 1000MX Series UPS

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

Internet Office 500VA Tower Standby 120V UPS with USB port

16551 EMERGENCY LIGHTING SYSTEMS. C. Refer to Cornell Design & Construction Standard for Emergency Power Systems.

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

British BS 88 Fuses. Introduction

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

High Power Programmable DC Power Supplies PVS Series

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

SL Series AC and DC Electronic Loads

Switching Power Module

Cisco Unified IP Phone Power Injector

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

D4 HP Dimmer User s Manual Rev City Theatrical, Inc.

Transcription:

LED Lighting Emergency LED Products The Philips Bodine BSL Driver Family ELI-S-20 Emergency Lighting Micro Inverter ELI-S-100 Dimming Inverter

Philips Bodine emergency LED drivers answer the call for LED Technology From torch lighting to porch lighting, T12 to T5 HO, filament to LED, technology evolves. So do we. LED technology is a new frontier. For most in the lighting industry there is a very real learning curve as we explore the intricacies, applications, limitations and potential of this amazing light source. Despite the curve, use of LED lighting for general lighting purposes is growing. As with other types of lighting, LED lighting must meet the life safety code requirements for emergency illumination. LED fixtures serving as emergency units must, therefore, provide at least 90 minutes of emergency lighting. Philips Bodine emergency LED drivers and emergency lighting inverters allow these fixtures to meet or exceed code. As with other types of lighting, LED lighting must meet the life safety code requirements for emergency illumination. 2 LED brochure

emergency lighting in LED applications. Terminology Array: A configuration of one or more (usually many more) LEDs connected to the same power source. Emergency LED Driver: A device that uses electronic circuitry to convert energy stored in a battery into the DC voltage and current necessary to drive the LED load within the parameters established by life safety codes. Integral-Base Lamp: A lamp in which the driver is built into the base. Because the lamp driver is built into the base, an emergency LED driver cannot be wired in between it and the lamp/led/led array. A unit with an integral base must, therefore, be driven in emergency mode by an inverter product, such as the Philips Bodine ELI- S-20 Emergency Lighting Micro Inverter. LEDs in Parallel: In parallel devices, all of the (+) terminals are connected and all of the (-) terminals are connected. All devices have the same voltage across them and draw as much current as their internal resistance allows. If all the devices are exactly the same, the current through each will be equal and the total current draw from the power supply will be that individual current multiplied by the number of devices or parallel legs connected. When LEDs are wired in parallel, each LED or group of LEDs will have the same voltage demand from the driver and draw an equal amount of current. LEDs in a Series: The (+) terminal of one LED is connected to the (-) terminal of the next. When LEDs are wired in series, the voltage necessary to run them is the sum of the individual LED voltage drop and the current is the same in all LEDs. LED: Light-emitting diode. A semiconductor device (diode) that emits visible light when electricity is applied. LED Driver: A device that converts line voltage into the DC voltage and current necessary to drive the LED load. Light Engine: A configuration of LEDs, often series and parallel, that cannot be divided by changing the wiring between the LEDs. Thus, a power source drives the whole unit or nothing at all. LED brochure 3

Choosing the Best Emergency LED Driver Selecting Emergency Drivers: OEM Solutions for Factory Installation Although we recommend that you send us your fixture or request a sample driver from us to test in your fixture, there are two critical pieces of information that will help you select the best emergency LED driver for your project. The leader in emergency lighting technology delivers again with emergency LED drivers. LED Array Voltage. What s the LED array voltage you re using? For best results, this voltage should be in the midrange of the output voltage for our products. For example, the Philips Bodine BSL23C has an output range of 3.0 to 20 VDC. If your LED array voltage is around 12.0 VDC, BSL23C could be a good option. If your array voltage is 18 VDC, however, the match would be less ideal, though it still may work. Philips Emergency Lighting offers emergency drivers for LED lighting applications. These drivers permit LED fixtures to serve as code-compliant emergency lighting units. Wiring Specifics. How are the LEDs wired? Are the LEDs in a series or parallel? Is the wiring accessible? When LEDs are wired in series, the voltage necessary to run them is the sum of the individual LED voltage drop and the current is the same in all LEDs. If they re wired in parallel, each LED or group of LEDs will have the same voltage demand from the driver and each will draw an equal amount of current. Thus, the summed currents in the parallel configuration may quickly exceed our capability or result in dramatically lower lumen output than expected. In terms of wiring accessibility, wiring that is accessible gives you the option of connecting as few or as many LEDs as appropriate to the emergency driver. 4 LED brochure

Philips Emergency Lighting Driver Portfolio Model Output Voltage (VDC) Typical Output Current (ma) Typical Output Power Dimensions Features or Applications Listing BSL17C (conduit) BSL17 (non-conduit) 45-130 100-200 7.0 W 12 x 2.4 x 1.5 Multiple mounting configurations; Ideal for LED downlight applications; Universal input BSL17C-C2 * * (conduit) BSL17-C2 * * (non-conduit) 15-50 100-270 7.0 W 12 x 2.4 x 1.5 Class 2; Multiple mounting configurations; Ideal for use with Fortimo DLM and SLM modules; Universal input REGULATED* BSL10 Cold-Pak 24-52 200-400 10.0 W BSL20LV BSL20MV BSL20HV 20-50 50-130 125-200 400-1000 150-400 100-160 20.0 W 8.97 x 3.5 x 2.9 + battery 16.6 x 2.8 x 2.85 + battery Easier to install; Output Class 2 Compliant; Cold temperature (-4 F to +131 F); Universal input High output provides 20W constant output power; BSL20LV is class 2; Universal input Output Class 2 Compliant for factory installation only BSL722 (non-conduit) 28-33 700 23.1 W 9.4 x 2.2 x 1.05 + battery Drives two LED arrays in parallel; Universal input BSL722 Cold (non-conduit) 28-33 700 23.1 W 9.4 x 2.2 x 1.05 + battery Designed for but not restricted to cold temperatures (-4 F to +140 F); Drives two LED arrays in parallel; Universal input BSL23C (conduit) BSL23 (non-conduit) 3-20 225-410 4.5 W 9.4 x 2.4 x 1.5 Multiple mounting configurations; Ideal for downlight and steplight applications for factory installation only BSL26C (conduit) BSL26 (non-conduit) 3-30 120-265 5.1 W 9.4 x 2.4 x 1.5 Multiple mounting configurations; Ideal for downlight applications; LVLE compliant NON-REGULATED BSL310C (metal case with conduit) BSL310M (metal case no conduit) BSL310 * * * (polycarbonate case no conduit) BSL310DF (metal case with conduit) BSL310CP (metal case with conduit) 10-50 200-400 10.0 W BSL310C / BSL310M 15.34 x 2.25 x 1.16 BSL310 14.5 x 2.25 x 1.18 10-50 200-400 10.0 W 15.34 x 2.25 x 1.16 Designed for linear strip fixtures; Class 2; Metal and polycarbonate case options available; Universal input Designed for linear strip fixtures; Class 2; BSL310DF has dual flex conduit; BSL310CP is compatible with Cree LMH Modules; Universal input for U.S. for U.S. BSL310C-CAN (metal case with conduit) BSL310M-CAN (metal case no conduit) BSL310-CAN (polycarbonate case no conduit) 10-36 300-400 10.0 W BSL310C / BSL310M 15.34 x 2.25 x 1.16 BSL310 14.5 x 2.25 x 1.18 Designed for linear strip fixtures; Class 2; Metal and polycarbonate case options available; Universal input Suitable for factory installation in Canada and U.S.; c *Regulated power output over 90 minutes. ** The BSL17C-C2 and BSL17-C2 are UL Classified for use with specific Philips Fortimo DLM (downlight module) and SLM (spotlight module) products. The designation of UL Classified for use with specific Fortimo DLMs and SLMs means that the BSL17C-C2/BSL17-C2 may be factory installed without additional UL testing in Fortimo fixtures for which an emergency option has been filed. ***The BSL310 is field installable exclusively with the Philips EvoKit LED retrofit. It cannot be field installed without the EvoKit. For more information, please contact PEL Sales at 800.223.5728 or Tech Support at 888.263.4638. Philips Bodine BSL products provide 90 minutes of emergency illumination in compliance with emergency codes. See the Life Safety Code 7.9.2.1 (2012). All BSL products above are for factory installation only. The lone exception is the BSL310 paired with the EvoKit. LED brochure 5

UL Listed for Factory or Field Installation. ELI-S-20 Emergency Lighting Micro Inverter The Philips Bodine 25W ELI-S-20 emergency lighting micro inverter transforms LED and fluorescent fixtures into code-compliant emergency lighting. ELI-S-20 includes auto select (120/277 VAC) to reduce wiring errors. With the convenient auto select, ELI-S-20 automatically detects input voltage and sets the output voltage accordingly. It is the ideal emergency backup for the Edison-base (screw-base) LED lamps that are commonly replacing CFLs in retrofit applications and is a superior choice for office, retail, hospitality and other similar spaces. ELI-S-20 allows fixtures to be on, off, switched or dimmed. It supports 100% of AC rated output throughout its 90-minute runtime so fixtures operate at full brightness during emergency operation. The device provides power to the input side of the fixture, including the ballast, and is designed for use with indoor applications. The ELI-S-20 features an LED-friendly sinusoidal (sine) waveform rather than square waveform output. Sinusoidal waveform is characterized by very low harmonic distortion and by clean power similar to that produced by utility-supplied electricity, making the ELI-S-20 well suited for even the most sensitive LED lighting. The micro inverter is UL Listed (25W) and (20W) unit equipment and designed for new and retrofit lighting projects. Product Highlights Works with LED and fluorescent fixtures up to 25W Is unit equipment Supplies 90 minutes of emergency illumination at full brightness Provides power to the input side of connected lighting loads Ideal for but not limited to screw-base LED lamps Compatible with Philips 22W TLED linear LED lamps Suitable for indoor, dry and damp applications Features fused output load connections AC Input Power Rating: 9.5W; output voltage 120/277 VAC (auto select), 60 Hz Dimensions: 16.6 x 2.8 x 2.85 Remote mounting distance: 250 feet maximum Warranty: 5 years (not pro-rata) UL Listed for 25W / for 20W Model Wattage Feature ELI-S-20 25 For LED and fluorescent lamps When an emergency LED driver cannot be used, line voltage inverters, such as ELI-S-20 and ELI-S-100, may be the best solution. 6 LED brochure

UL Listed for Field Installation. ELI-S-100 Emergency Lighting Inverter The ELI-S-100 provides emergency output power of 100W maximum and supports the lighting load for a minimum of 90 minutes. While the ELI-S-100 works with both fluorescent and LED lighting, it offers two important features for LED applications: dimming capabilities and sinusoidal output. Dimming in LED Applications ELI-S-100 s dimming feature delivers cost-savings, flexibility and control in LED applications. The dimming capability allows a higher power fixture to operate at a dimmed 100W maximum emergency-mode lighting level, eliminating reliance on a high power inverter to run the fixture. Alternately, ELI-S-100 allows a string of multiple fixtures to be driven in emergency mode at a combined 100W maximum. For example, four100w LED fixtures may be connected to one ELI-S-100 and dimmed for emergency operation to 20% of normal power, with each LED fixture supplying 20W of output power (20W x 4 = 80W).* *Note dimming drivers are less efficient at reduced power. This inefficiency must be accounted for in the design. Two models are available: ELI-S-100-120V and ELI-S-100-277V. Product Highlights Compatible with LED and fluorescent fixtures Provides emergency output power of 100W maximum Features sinusoidal output Dimming compatible with 0-10V systems The ELI-S-100 provides a dimming control output of 2-10 volts, and the emergency-mode dimming voltage is field-settable in five steps to provide nominally 20%, 40%, 60%, 80% or 100%. The dimming feature requires a dimming AC driver. Sinusoidal Output The ELI-S-100 features an LED-friendly sinusoidal (sine) waveform rather than square waveform output. Sinusoidal waveform is characterized by very low harmonic distortion and by clean power similar to that produced by utility-supplied electricity. May be connected to one or multiple fixtures Supports emergency lighting for a minimum of 90 minutes Includes fused output load connections Two versions available: 120V model and 277V model Remote mounting distance: 250 ft. Temperature rating: 32 F to 104 F (0 C to 40 C) Dimensions: 12.562 x 9.812 x 4.675 (319 mm x 249 mm x 119 mm) Weight: 25 lbs. (11.34 kg) with batteries installed Warranty: Unit, 5 years; Battery, 3 years +7 years pro-rated UL Listed/ Designed for field installation Model Wattage Feature ELI-S-100 100 Offers LED dimming capabilities LED brochure 7

Proper installation, of course, is critical to emergency operation. Emergency LED Driver Installation Note: Emergency LED drivers are UL Recognized and must be factory installed with one exception. The BSL310 may be field installed when paired with the Philips EvoKit LED retrofit. The installation of Philips Bodine emergency LED drivers is similar to that of fluorescent emergency ballasts. Depending upon the emergency LED driver selected and fixture type, the emergency driver may be installed inside, on top of or remote from the fixture. When an emergency LED driver cannot be used, line voltage inverters may be the best solution. As with Philips Bodine fluorescent emergency ballasts, Philips Bodine emergency LED drivers do not affect normal fixture operation and may be used with a switched or unswitched fixture. If a switched fixture is employed, an unswitched hot lead must be connected to the emergency driver. In either case, the emergency driver must be fed from the same branch circuit as the AC driver. Please see the product specification and instruction sheets for more information. Proper installation, of course, is critical to emergency operation. However, regular code-compliant testing and maintenance must also be done and are essential to any life safety program. 2014 Philips Emergency Lighting All rights reserved. Document order number: L0000022 14.5 236 Mt. Pleasant Rd. Collierville, TN 38017 Sales 800.223.5728 Fax 901.853.5009 www.philips.com/bodine