ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation



Similar documents
STEPS TO COMPRESSOR SELECTION & SIZING

UNDERSTANDING REFRIGERANT TABLES

AIRCRAFT PERFORMANCE Pressure Altitude And Density Altitude

How to Choose the Right Air Compressor

Technical Bulletin 144. Air Volume Conversions. by:

Pressure Drop in Air Piping Systems Series of Technical White Papers from Ohio Medical Corporation

Centrifugal Fans and Pumps are sized to meet the maximum

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Meriam Instrument LFE Data Sheet

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

Technical Information

THE HUMIDITY/MOISTURE HANDBOOK

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Pump Formulas Imperial and SI Units

Methods and Equipment for Calibration of Variable Area Meters (Rotameters)

High Altitude HVAC. Silvertip Integrated Engineering Consultants

Example Calculations Evaluation for Fine Bubble Aeration System. Red Valve Company, Inc. 700 NORTH BELL AVENUE CARNEGIE, PA

Appendix C: Conversions and Calculations

Characteristics of Evaporators

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

Barometric Effects on Transducer Data and Groundwater Levels in Monitoring Wells D.A. Wardwell, October 2007

Air Eliminators and Combination Air Eliminators Strainers

QUESTIONS THERMODYNAMICS PRACTICE PROBLEMS FOR NON-TECHNICAL MAJORS. Thermodynamic Properties

Fan Applications & System Guide

Rusty Walker, Corporate Trainer Hill PHOENIX

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Compressors Buying Guide

2 1/2 Pipe. 40 = height. the gauge pressure inside the vessel from the gauge pressure at the nozzle inlet as shown:

REAL CHAMBERS CORPORATION SQL PRE-INSTALLATION/ SITE PREPARATION MANUAL

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

One basic concept in math is that if we multiply a number by 1, the result is equal to the original number. For example,

THE PSYCHROMETRIC CHART AND ITS USE

NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT.

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS. Robert J. McKee Ray G. Durke

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

VAV Laboratory Room Airflow The Lowdown on Turndown

Basic Nameplate Information

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

CO MPa (abs) 20 C

Appendices. Appendix A This appendix is a glossary defining terms used in the compressed air industry.

Unit 24: Applications of Pneumatics and Hydraulics

User s Manual Laminar Flow Elements

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Grade 8 Science Chapter 9 Notes

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

A practical guide to restrictive flow orifices

AIR POWER GLOSSARY. Air Outlet/Hose Connection An air outlet/hose connection is a 1-1/4 NPT thread fitting where the air hose attaches.

COMPRESSED AIR ULTRASONIC LEAK DETECTION GUIDE

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

The Precharge Calculator

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Heat Recovery In Retail Refrigeration

Turbo Tech 101 ( Basic )

Laundry Hot Water Systems

Why and How we Use Capacity Control

Chapter 10 Temperature and Heat

= 800 kg/m 3 (note that old units cancel out) J 1000 g = 4184 J/kg o C

MODEL DJ-3 DRAFT INDUCER SPECIFICATIONS

Ambient Pressure = and Pressure, collectively

Efficient Pneumatic Conveying Dense Phase vs. Dilute Phase: How Being Accurate is More Cost Effective Than Being Conservative

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

VACUUM REFRIGERATION SYSTEMS

Frequently Asked Questions Generators

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

Energy Recovery Ventilation Equipment

MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC

Vacuum Systems CEU 194. Continuing Education from the American Society of Plumbing Engineers. December ASPE.

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Quiz On Information Learned From Chapter 1

Pipe Sizes For Water Distribution System Design

OIL & GAS PRODUCTION AUDITING

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

Technical & Sizing Bulletin for Meriam LFEs. Laminar Flow Elements

Preferred SI (Metric) Units

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Principals of Condensing Boiler System Design

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

A BRIEF INTRODUCTION TO CENTRIFUGAL PUMPS

AABC Specifications for Testing and Balancing HVAC Systems

Name Date Class. As you read about the properties of air, fill in the detail boxes that explain the main idea in the graphic organizer below.

ANNUBAR FLOW CALCULATION PROGRAM (For the FloBoss 103) User Manual (QER 04Q019)

How do I measure the amount of water vapor in the air?

REGULATORS 175/153 Series

Appendix C. Minimum Equipment Efficiency Standards

Heating Water by Direct Steam Injection

Steam Jet Vacuum Pumps

Transcription:

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation Ohio Medical Corporation 1111 Lakeside Drive Gurnee, IL 60031 Phone: (800) 448-0770 Fax: (847) 855-6304 info@ohiomedical.com www.ohiomedical.com 560808 Rev. 2

TERMINOLOGY ACFM Actual Cubic Feet per Minute CFM Cubic Feet per Minute ICFM Inlet Cubic Feet per Minute MDCFD Thousand Standard Cubic Feet per Day psia Pounds Per Square Inch in Absolute pressure SCFM Standard Cubic Feet per Minute NOMENCLATURE P 1 Barometric pressure at the non-standard site in psia T 1 Ambient air temperature in R P F Pressure after the inlet filter in psia T F Air temperature after the inlet filter in R P sat Saturation Pressure φ Relative Humidity at the non-standard site T std Standard temperature in degrees in R (60 F = 60 + 460 = 520 R) Standard air pressure in psia (14.696 psia) P std Ohio Medical Corporation. 1

INTRODUCTION The term CFM is often confusing and difficult to define for one condition, and one definition does not satisfy all conditions we encounter in our customer s applications throughout the world. Simply put, CFM is an acronym for Cubic Feet per Minute, and defines the volumetric flow rate of a fluid displaced by a pump (like a compressor, a blower, or a booster). The term CFM is generally used to describe a pump s capacity, and is used to determine the size of the source system for medical, industrial and other applications. The common terms used to specify a volumetric flow rate in different industries are SCFM, ACFM, ICFM, MCFM, MSCFD, etc. Often times these terms are very vague, and in turn, misunderstood. The primary reason for all the difficulties described above is because air is a compressible fluid, due to the atmospheric variation in air pressure, temperature and density - the fluid properties are constantly changing. The conditions are dependent on location, time of the year, altitude, etc. Thus, it is important to understand that the conditions in Los Angeles vary significantly from the conditions in Denver. The terms SCFM, ACFM and ICFM are often used to define the different instances and conditions of a compressor s capacity and operation. If the CFM terms are used appropriately, they can be useful in the direct and relative comparison to their operating conditions, and to other source systems. The intent of this paper is to provide a better understanding of SCFM, ACFM and ICFM and their meaning, so we can properly select and size compressors for their specified and intended applications. Ohio Medical Corporation. 2

DESCRIPTION The term cubic feet per minute (CFM) describes the fluid flow rate, (measured in volume - ft 3 ) not the weight per minute on the inlet side of a compressor. The compressor s performance capability is measured in how many one ft 3 cubes of fluid are able to move per minute through the inlet. Figure 1 One Cubic Feet of Volume Now consider the conditions in Los Angeles, where one cubic feet of air weighs 0.075 lbs., and in Denver, where one cubic feet of air weighs 0.062 lbs. Even though the volume is the same, the weight (mass) of the air is different. Los Angeles W=0.075 lbs. Denver W=0.062 lbs. Figure 2 Constant Volume Now consider a constant weight Condition (mass) condition. A balloon filled with 31 actual cubic feet of air in Los Angeles is then taken up to Denver. The balloon now contains 38 standard cubic feet of air. Los Angeles V=3 3 Denver V=38 ft 3 Figure 3 Constant Mass Ohio Medical Corporation. 3

The two examples illustrate the confusion of measuring volume due to the fact air is compressible. In this instance, the number of gas molecules occupying a particular volume, depends on the pressure and temperature conditions of that location. At a microscopic level, the air molecules are closer together (greater air density) in Los Angeles compared to the air molecules in Denver. Los Angeles Denver Figure 4 Variation in Air Molecule Density A variation in air pressure results in a variation in air density, as show in Figure 4, and is consistent with constant volume concept in Figure 2. Another way to look at this is to analyze the number of air molecules in a 120-gallon receiver tank at 80 psia and 100 psia, where the higher pressure tank occupies a greater number of molecules. The weight and density vary primarily because the atmospheric pressure is significantly different between the two cities, as show in Table 1. Note the terms for actual and standard for the volumes described above leads us to SCFM and ACFM. City Altitude (ft) Atmospheric Pressure (psia) Los Angeles 0 14.69 Denver 5280 12.12 Table 1 Variation in Atmospheric Pressure between the Two Cities SCFM and ACFM The term standard cubic feet per minute (SCFM) is usually used as a standard reference condition for flow rate performance for atmospheric pressure at sea level, as opposed to actual cubic feet per minute (ACFM) is typically used to rate flow rate performance of compressor systems for actual pressure and temperature. SCFM is defined as air at 14.696 psia and 520 R (60 F). Sometimes other conditions are used, such as 530 R (70 F), 528 R (68 F), 0% and 36% Relative Humidity for describing the standard conditions. It is important to remember SCFM is defined by a fixed set of conditions or common reference point for comparing different compressors systems. Otherwise the consequences are the improper sizing of the compressor system for its true application. This point will be apparent in the two examples to follow. Ohio Medical Corporation. 4

The conditions at sea level are generally not experienced by our customers and for practicality purposes ACFM is typically used for sizing compressors for these applications (+100 F and lower pressures). The conversion for ACFM from SCFM is shown by the formula below. P T1 ACFM = SCFM P std ( Psat φ1 ) Tstd 1 1 Equation 1 Note, absolute units must be used in the equation. SCFM ACFM EXAMPLE 1 Normal Day For this example we will reference a 30-hp compressor operating at 1020 rpm, and use it in Los Angeles and Denver to demonstrate how SCFM and ACFM should be used. Assume the requirement for compressed air is 125 psig discharge pressure, and 100 SCFM of demand, and the site ambient conditions are T 1 = 80 F (540 R), P 1 = 14.7 psia and φ = 75%, and this results in the following: ACFM = 106.6 If we assume that all ambient conditions remain the same with the exception of moving the compressor to Denver, where the atmospheric pressure will drop to P 1 = 12.12 psia, the resulting volumetric flow requirement becomes: ACFM = 130.0 In order to deliver the same amount of work (100 SCFM at 125 psig), the compressor in Denver must ingest larger quantities of the lower-density air, due to the change in the atmospheric pressure. Location SCFM ACFM % Diff. Los Angeles, CA 100 106.6 6.6 % Denver, CO 100 130.0 30.0 % Table 1 Normal Day between the Two Cities To provide the required 100 SCFM of work in Denver, the compressor must be able to process 130 ACFM. SCFM ACFM EXAMPLE 2 Hot Humid Day For this example we will reference the first example for Los Angeles and Denver and change the conditions to a hot humid day. Assume the same requirements and conditions except for the ambient temperature of T 1 = 100 F (560 R) and relative humidity of φ = 100%, which results in the following: Ohio Medical Corporation. 5

Location SCFM ACFM % Diff. Los Angeles, CA 100 115.1 15.1 % Denver, CO 100 141.6 41.6 % Table 3 Hot Humid Day between the Two Cities The results at the higher temperature and higher humidity condition show an even greater amount of air is needed (approximately 10% more air is needed compared to Example 1) to meet capacity requirements. Thus, we recommend using hot humid days to calculate the worst case conditions for sizing a system. Tables can be constructed to size systems from Equation 1, but it is up to the specifier to determine the proper conditions. Table 4 in Appendix A shows the expansion ratio conversions for SCFM and ACFM for the conditions described in this example. ICFM The term Inlet Cubic Feet per Minute (ICFM) is used by compressor vendors to establish the conditions at the inlet of compressor in front of the inlet filter, blower, or booster. If the pressure and temperature condition at the inlet is the same as after the filter, blower, or booster, then the ICFM and ACFM values will be the same. However, as the air passes through these components, there will be always be a pressure drop or rise, and Equation 2 is used to approximate ACFM. ACFM P P T T 1 F = ICFM Equation 2 F 1 Then ICFM is used to measure inlet capacity, which will approximate ACFM for this type of a system. Note, when a blower or booster is added, the inlet may experience significantly higher pressure and temperature conditions than the actual ambient conditions. Greater the difference in pressure and temperature, greater the difference in ACFM and ICFM. Finally, there are losses (air seal, heat, etc.) associated with the use of these components and coupled with the pressure and temperature differences, the use of ICFM will result in a misleading outcome in determining a compressor s capability. Note at higher altitudes, the specifier must account for the decrease in air pressure when estimating a compressor s performance and sometimes blowers or boosters are used for economic reasons, but this is not always the best solution. Thus, in certain markets, like the Medical, where tighter controls are employed, ICFM should not be used to determine a compressor s capacity, instead ACFM should be used. Ohio Medical Corporation. 6

CONCLUSION This paper defined, summarized and applied the terms SCFM, ACFM and ICFM, and the differences between them. The term CFM, at a fundamental level, is defined such that a compressor will pump a specific volume of air in a given amount of time when the compressor speed and flow resistance matches the test conditions. A specifier s most difficult task is sizing a compressor properly, by specifying the compressor s required capacity. It is important to note that the proper understanding of these terms will help a specifier in selecting a compressor. The specifier should use SCFM to compare differences in compressor capacities, and ACFM for actual nonstandard site conditions and proper load applications. ICFM should be used only when a filter, a booster or a blower is added to the system, and should not be used in determining compressor selection, due to misleading results. Finally, the reference pressure, temperature, and discharge pressure must be specified, in addition to the required capacity. When specifying the compressed air requirement, the worst case conditions should be used (i.e. - generally hot humid days, as shown in Example 2). Otherwise, there will be confusion in the sizing process. Other important factors to consider in compressor capacity and system sizing are: Air requirement or demand in a given day Normal operating conditions Other operating conditions (hot humid days are the worst) Single-stage or two-stage compressor (compression ratio) CFM reduction due to flow resistance Electrical characteristics and power requirement Area classification (Elevation) Compressors with a higher CFM rating will pump more air than compressors with lower CFM Ohio Medical Corporation. 7

APPENDIX A Pressure (psia) Volume Expansion Ratio SCFM to ACFM ACFM to SCFM 14.70 1.151 0.869 14.50 1.168 0.856 14.25 1.190 0.840 14.00 1.213 0.824 13.75 1.237 0.809 13.50 1.261 0.793 13.25 1.287 0.777 13.00 1.314 0.761 12.75 1.341 0.745 12.50 1.371 0.730 12.25 1.401 0.714 12.00 1.433 0.698 11.75 1.466 0.682 11.50 1.500 0.666 11.25 1.537 0.651 11.00 1.575 0.635 10.75 1.615 0.619 10.50 1.658 0.603 10.25 1.702 0.588 10.00 1.749 0.572 9.75 1.799 0.556 9.50 1.851 0.540 9.25 1.907 0.524 9.00 1.966 0.509 8.75 2.029 0.493 8.50 2.097 0.477 8.25 2.168 0.461 Table 4 Volume Expansion Ratio Conversion Chart Ohio Medical Corporation. 8