Flex Focus 1202 Ultrasound Scanner



Similar documents
Reliable versatility. Philips HD5 ultrasound system

More than a Portable System

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

B E S T - I N - C L A S S C O M P A C T M U L T I - P U R P O S E U L T R A S O U N D

Improve your image. ClearVue 350 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Philips CX50 CompactXtreme System. A New Class of Compact Echocardiography

Contents. HD11 XE Quick Guide

Falcon 2101 EXL. B-mode and M-mode multipurpose ultrasound scanner. Urology. Surgery. Radiology / General. Obstetrics / Gynecology.

UGEO H60 PERFORMANCE IN STYLE

AXIS 262+ Network Video Recorder

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User Guide Type Biplane Transducer. English BB0339-M June For Professional Users Only

SMART Board interactive flat panel with appliance Model 8055ie-SMP

The ultrasound system that sets new standards

Samsung Ultrasound H60

Leading the New Standards

ProART Robotic Drop-in Transducer

SAMSUNG ULTRASOUND RS80A

Company profile. Quote from the analyst of. Company Milestone. Feel the Difference. Tel: Fax:

Ultrasound. Your versatile performer to depend on. Philips ClearVue ultrasound family for women s health care

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

DR Retrofit Kit 1417 WL Configuration Integrated PACS

LT-82 Stationary IR Transmitter

// SUPER technology for precise web viewing: SUPER HANDYScan Be inspired. Move forward.

Vivid S6. Cardiovascular ultrasound system. imagination at work. GE Healthcare

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

U1602A Handheld Oscilloscopes, 20 MHz

Improve your image. ClearVue 650 ultrasound system

Technical Data FLIR E40bx (incl. Wi-Fi)

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications

SMART Board Interactive Display Model SBID8070i

SMART Board interactive whiteboard system

Philips PageWriter Touch ECG System

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact:

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

Waveform Monitor Audio & Loudness Logging

3200L 32" Interactive Digital Signage Touch Display

Mindray Ultrasound System Frequently Asked Questions

Compactly Powerful. Ultrasound System UGEO PT60A CT-UGEO PT60A-CWW-CMI-0705-EN

DynaGuard 200 Series. Compact and Versatile MPEG-4. Ver. 1.1

DC Electronic Loads 8500 series

4 Port full HD multiviewer real-time USB/KVM switch

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

Specifications for the Gateway M1300 Tablet PC

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

MS6000 Microform Scanner

SMART Board interactive whiteboard system Model 680iv

SMART Board 685ix interactive whiteboard system Model 685ix

SNC-VL10P Video Network Camera

User Manual.

Captus 3000 Thyroid Uptake And Well System

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

DVB-T2 DIGITAL TV BOX

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

How To Use The Dc350 Document Camera

StructureScan 3D. User Guide ENGLISH.

TrueAlarm Fire Alarm Systems

Macintosh Portable. Overview

Sympodium Interactive Pen Display

How To Sell A Talan

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

Microwave Meter. Instruction Manual

Drayton Digistat +2RF/+3RF

SMART Board interactive whiteboard system projectors

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

CDE5501-TL Scan for more information

DAB+ / FM Tuner Model: TU-201

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

How To Use A High Definition Oscilloscope

Type-D EEG System for Regular EEG Clinic

CCS-UC-100 Crestron RL Group Collaboration System for Lync

TECHNO PACK T LED. Now with MULTIPOINT 3.0 measuring software! The Latest Generation of the TECHNO PACK Product Range

Allows you to play & control music and video content stored on your iphone, and charge it while it s docked

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

LCD4Video 7" LCD Monitor USER MANUAL Model # LCD7n

Point of view HDMI Smart TV dongle Mini RF Keyboard

4-Channel Thermometer / Datalogger

Datex-Ohmeda Critical Care Monitor

thyroid uptake systems

Simpler on the outside. Smarter on the inside.

Hand-held marking system FlyMarker mini

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

ACR880 GPRS Portable Smart Card Terminal

HP ProDisplay P17A LED Backlit Monitor. User Guide

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

CONSOLES R E G I A S E R I E S LIGHTING

DryView CHROMA Imaging System

Transcription:

Flex Focus 1202 Ultrasound Scanner Product Data USES Urological and brachytherapy applications, including cryotherapy Pelvic floor applications Colorectal applications Abdominal scanning Small part scanning Vascular scanning Obstetric and gynecological scanning Breast scanning General imaging Regional anesthesia Musculoskeletal scanning Intraoperative scanning Interventional procedures BENEFITS Combines high class image quality and Doppler performance with state-of-the-art specialist transducers IQPAC technology includes Enhanced Tissue Definition and Angular Compound Imaging for speckle reduction and better organ definition Fully digital signal processing together with IQPAC delivers superior image quality with enhanced tissue definition 19 monitor so you can see full-size sagittal and transverse images at the same time for improved diagnosis Extremely user-friendly fast, intuitive, customizable user interface and ergonomic design Very mobile compact construction Fits perfectly anywhere in your practice modular design Height-adjustable control panel (when used with mobile keyboard dock) for an ergonomic position that reduces workrelated strain injuries and lets you share information with patients Programmable transducer Start-Stop button to change both transducer and application Specially designed puncture guides for interventional procedures Simultaneous triplex imaging with high Pulse Repetition Frequency (PRF) to maximize onscreen information Fully integrated 3D capabilities 360º scanning DICOM capabilities Battery solution provides mobility and Power Save Mode provides instant wake up and increases battery uptime status display continuously shows remaining uptime, even when scanner is turned off Available versions of Flex Focus 1202 There are 5 versions of the Flex Focus 1202 available for order: Flex Focus 200 Flex Focus with basic functionality Flex Focus 200 Surgery basic surgical scanner Flex Focus 400 mid-range color scanner Flex Focus 400 Anesthesia mid-range color scanner dedicated to regional anesthesia Flex Focus 700 dedicated high-end surgical scanner with touch screen and remote control Note: Flex Focus 200 and Flex Focus 700 are only available in some countries. Some features and options are only available on some versions of the scanner. See Ordering Information for details. BP0132-H Type 1202 Product Data - BK Medical 2010 August 2010

Unique Features and Benefits with Flex Focus 700 Surgical scanning Fits perfectly anywhere in the OR modular design Can be controlled from within the sterile field, using remote control Intuitive touch screen Simplified control panel (optional full control panel available) Sealed control panel with no slides or dials where liquids can get inside for easier and faster cleaning and disinfection Picture-in-Picture (PiP) enables simultaneous display of camera and scanner images on a single monitor Remote Control* Control all functions of the scanner from within the sterile zone Low power, short-range wireless connectivity Move it as a handheld pointing device to control cursor on screen Can be disinfected Surgery Pro Package Contains optimized setups and measurements for surgical ultrasound * For future release GENERAL DESCRIPTION FOR ALL VERSIONS OF FLEX FOCUS BK Medical's Flex Focus 1202 Ultrasound Scanner is a fully digital, multipurpose scanner based on the latest advances in ultrasound technology. The system platform is based on the latest PC technology and Windows software, making it easy to implement upgrades as required. User Interface and Ergonomics The revolutionary scanner design is based on extensive user input and ergonomic principles. Compact, mobile and easy to maneuver. Logical and simplified control panel design easy to operate the scanner without taking your eyes off the screen. Illuminated control panel keys. Scanner unit and control panel move up and down and swivel easily on mobile dock. Extensive possibilities for customizing software. Programmable foot switch controls a range of different functions such as freeze/record and print. Transducers available for most clinical areas. Transducer buttons control user-defined functions. Up to 3 active transducer sockets; 2 for array transducers and 1 for single-element transducers. You can keep a selection of transducers ready for easy use. Easily accessible transducer connectors make connectivity faster. Transducer cables conveniently out of the way. Sealed control panel makes cleaning and disinfection easier. Battery pack with 2 or 4 rechargeable batteries provides up to 3 hours uninterrupted scanning time and instant wake up from Power Save Mode. Easy battery change no tools required. Image Presentation Advanced ultrasound technology ensures very high image quality in terms of axial, lateral and contrast resolution, as well as penetration. High-resolution digital images with uniform focus over the entire image depth. IQPAC technology featuring Enhanced Tissue Definition (ETD) and Angular Compound Imaging (ACI) provides speckle reduction and better organ definition. ETD enhances the anatomically correct continuous borders, enabling lesion margins to be clearly visualized. ACI improves organ definition by combining images acquired from different angles. A range of application-specific multifrequency transducers is available. High-frequency scanning (up to 18 MHz) gives superb image quality for breast, small part, peripheral vascular and musculoskeletal scanning. Parallel quad-beam signal processing provides higher frame rates and resolution. High frame rate is especially valuable for studying flow dynamics in color Doppler or power Doppler mode. Simultaneous split-screen display two different images live on the monitor at the same time (for example, two different scanning planes (with a biplane transducer), or two different scanning modes such as B-mode and Color Doppler). Freeze Zoom zoom on a specific section of the image. 2 Type 1202 Product Data BK Medical 2010

Auto Gain automatically returns the B-mode overall gain and the TGC curve to the preset values. Full Range of Doppler Functions Speaker for auditory indication of blood flow. Automatic real-time calculation of selected parameters from Doppler data. Numerical and graphical display of results. Power Doppler Visualize density of moving blood vessels. Directional power Doppler indicates flow direction. Color Doppler (CFM Color Flow Mapping) Can be used during B-mode scanning. Superimposes color-coded flow data on the image to show both direction and velocity. Variance Doppler and Variance + Velocity Doppler are available. Spectral Doppler Fast Fourier Transform (FFT) analysis of the Doppler signal. Can be displayed with the B-mode image to give Duplex Doppler. Can be used with B-mode and either color Doppler or power Doppler to give Triplex mode. Position, size and angle of the sample volume can be changed, and the spectrum can be displayed in gray tones or color. Includes Pulsed Wave (PW). Auto Doppler automatically adjusts the baseline and scale (PRF) to prevent aliasing and optimize the display of the Doppler spectrum. Steerable Doppler Ability to visualize blood flow in vessels parallel to the surface using linear array transducers. Insonation angle electronically adjustable up to ±20º, depending on the transducer used. Tissue Harmonic Imaging Pulse Inversion technology improves signal-to-noise ratio, leading to better contrast resolution. This is important for detecting subtle tissue differences and is useful when scanning technically difficult patients. Pro Packages Pre-programmed Pro Packages containing multiple Diagnostic Setups and application-specific calculations are available. You can also customize your own Pro Packages. Urology Pro Package Contains all essential setups and measurements for: Precise volume studies Simultaneous biplane imaging Tissue harmonic imaging Brachytherapy Pro Package Biplane transducer 8848 can be used for seed implantation with a choice of 4 brachytherapy matrix templates. A matrix offset can also be programmed to compensate for non-standard matrix. Contouring of all organs. Streamlined workflow with Varian compatibility. Setups and measurements can also be used for cryotherapy. Pelvic Floor Pro Package Contains optimized setups and measurements for pelvic floor ultrasound. Colorectal Pro Package Contains optimized setups for colorectal ultrasound within the following application area: Anorectal ultrasound. Anesthesiology Pro Package Contains optimized setups and measurements for ultrasound guided use of regional anesthesia. Obstetrics, Gynecology, IVF, Breast, Vascular and General Ultrasound Pro Packages Basic image settings, measurement and calculation functions. Optimized setups, growth curves and reports. Surgery Pro Package Contains optimized setups and measurements for surgical ultrasound. Cine (Image Review) High-capacity cine function. Review a series of the most recently recorded images, including Doppler spectra. Make measurements and perform calculations on stored images. Cine Loop Continuous playback of a series of images repeats after the last image is displayed. Adjustable Cine Loop speed and start and stop positions. 3D Imaging (option) Advanced, fully integrated 3D. Image acquisition using freehand or mechanical localizers. Specially designed magnetic wheel mover for acquiring data sets with rectal transducers. Anorectal transducer 2052 with fully integrated built-in 3D mover. 3D image can be displayed as a volume cube or as three orthogonal planes in 4-Up or 6-Up view. 3D image can be copied directly to CD/DVD or USB storage device. 3D image can be rendered, rotated and sliced, revealing information that would not be accessible in 2D. Surface Rendered, Volume Rendered and Maximum Intensity Projection (MIP) image processing. Distance and volumetric measurements with the fully quantitative Professional 3D option. Transducers Range of application-specific transducers listed in table Indicated Use for Transducers Supported by Flex Focus 1202. Documentation Facilities Images can be saved using scanner hard drive network drive CD/DVD (option) USB flash memory device printer videotape multi-format camera Internal clip browser with flexible display. Type 1202 Product Data BK Medical 2010 3

Images and video clips can be reviewed and then saved to external media storage. The external clip browser can then be used to view stored images. Patient Archiving Save directly in patient s file on scanner hard disk: 2D images 3D volume studies (option) reports patient/image comments Transfer images to USB storage device, CD/DVD or over a DICOM network to a PC or PACS (Picture Archiving and Communication System). (CD/DVD and DICOM are options.) DICOM support includes Store, Print (B/W and color), MPPS (Modality Performed Procedure Step), Storage Commitment and Modality Worklist. With Modality Worklist, patient data is retrieved directly from the Hospital or Radiology Information System (HIS/RIS). Cleaning and Disinfection Designed for easy and convenient cleaning. Trackball and accessories on the keyboard control panel are removable for easy cleaning. Scanner can be wiped down with a disinfectant solution listed in Specifications. All BK Medical transducers can be disinfected by immersion in suitable solutions. Some transducers can be processed using STERIS SYSTEM 1 *, STERRAD 50 System, STERRAD 100S System, STERRAD 200 system, or ethylene oxide gas. Most non-disposable puncture attachments can be autoclaved. Sterile guides are available for some transducers. Disposable transducer covers are available. Safety All BK Medical ultrasound equipment is designed and tested according to the requirements of the IEC publications 60601-1, "Medical Electrical Equipment. * STERIS SYSTEM 1 is not market cleared in the USA. ** Remote control is for future release. Options See Ordering Information for details. Desktop option Mounted on wall Battery solution Printer available Touch sensitive display with simplified control panel and remote control** 4 Type 1202 Product Data BK Medical 2010

Indicated Use for Transducers Supported by Flex Focus 1202 Transducer Supported by Scanner Application Type Number Frequency Range Array Type Flex Focus 200 Flex Focus 200 Surgery Flex Focus 400 Flex Focus 400 Anesthesia Flex Focus 700 Puncture Guide Tissue Harmonic Imaging Angular Compound Imaging Abdominal Intraoperative Musculoskeletal Obstetrics Pediatrics Peripheral Vascular Small Part Transrectal Transvaginal Fetal Cardiac Neurosurgery 1850 8539 6004 6005 5 10 10 5 10 SE 2050 6 16 SE 2052 6 16 SE 8662* 5 8 CA 1 8666-RF* 5 10 CA 8667 5 10 CA 8670 5 12 LA 8802 3 6 CA 8808* 5 10 CA/CA 8808e 5 10 CA/CA 8809* 6 15 LA 8811 5 12 LA 8814* 5 10 CA/CA 8815* 5 10 CA 8816* 5 10 CA 8818 5 12 CA/CA 8819 5 9 CA 8820e 2 6 CA 8823 2 6 CA 8824* 5 10 CA/CA 8827 2 4 PA 8830 2 6 CA 8848 5 12 CA/LA 8870* 6 18 LA Array Type: CA Convex Array LA Linear Array PA Phased Array SE Single Element (Mechanical). Does not support Enhanced Tissue Definition (ETD) * Not licensed by Health Canada 1 Market cleared for neurosurgery use by the FDA only Type 1202 Product Data BK Medical 2010 5

Specifications Flex Focus 1202 SCANNING MODES (MAIN) B (B-mode) M (M-mode) C (Color Flow Mapping: Velocity, Variance and Velocity + Variance) P (Power Doppler and Directional Power Doppler) D (D-mode, PW, Pulsed Wave Doppler) THI (Tissue Harmonic Imaging) SCANNING MODES (COMBINATION) B + M B + C B + D(PW) (Duplex) B + P B + C + D(PW) (Triplex) B + P + D(PW) (Triplex) SCANNING MODES (SIMULTANEOUS SPLIT) B + B B + THI B + (B + C) B + (B + P) TRANSDUCER CENTER FREQUENCY RANGE** Linear and convex array transducers: 2 18 MHz Phased array transducer: 2 4 MHz Single-element transducers: 5 20 MHz 360º rotating single-element transducers: 5 20 MHz Volumetric transducer: 5 20 MHz FREQUENCY SELECTION B-mode: Up to 6 manual and 128 Automatic (Depth dependent) THI: Up to 128 Automatic (Depth dependent) C-mode: Up to 3 Manual D-mode: Up to 3 Automatic DISPLAY 19 LCD flat screen, portrait IMAGE CHARACTERISTICS Ultrasound image: 800 x 780 pixels; 256 gray levels, 4096 colors Graphics overlay: 1024 x 1280 pixels; 32-bit true color Presentation: Images can be mirrored up/down and left/right SWEEP SPEED 2 14 seconds per screen (1 9 cm/s) SIZE (ZOOM) Examination Penetration: Max 28 cm Examination Penetration: Min 0.5 cm Works in Freeze and Scanning mode Up to 15 zoom levels FRAME RATE >600 Hz (automatically optimized), depending on the transducer and the scanning mode PREPROCESSING TGC: Overall gain, fine gain (TGC) System dynamic range: 170 db Gray scale conversion: 20 scales Color scale conversion: 8 scales Doppler conversion: 8 scales B-mode Color Overlay: 32 bit POST PROCESSING Gray Scale Selection Color Scale Selection Noise Reject Depth Zoom Pan Gain FOCAL ZONES Up to 25 transmit zones depending on transducer Up to 8 transmit zones for composite focus Continuous receive focusing FEATURES Fully digital IQPAC (includes Enhanced Tissue Definition (ETD) and Angular Compound Imaging (ACI)) Pulse Inversion Tissue Harmonic Imaging Split screen (vertical and horizontal) Simultaneous live split-screen imaging User setups Multibeam: 4 in parallel, Quad Beam Channels: 5120 processing capability Copy/Recall system and transducer setup Image Review (cine) for up to 3000 images depending on scanning mode Image Storage: CD/DVD (option), hard disk and USB storage device Hard disk capacity: Expandable to 530GB (80GB built in), 530,000 images (30,000 on built-in HDD) Clip browser Clip editor Report function DICOM networking (option) Fully integrated 3D (option) On-screen timer Edge enhancement Non-linear 2D persist filter Picture-in-Picture (option 1202-3 only) User-defined hard keys Matching sliding filters True Hilbert detection Post-processing Freeze Zoom (or Post Zoom) Adjustable monitor and keyboard Support for phased array transducers Coded Excitation Position display and control of volumetric transducer (option) Expanded sector (Trapezoid) Real time display of acquired 3D data (option) Auto Doppler Auto Gain Compatible with Varian (option) PATIENT ARCHIVING Search possibilities include Patient name, ID, Last Exam Date, Archive Status, Storage Commitment, Free-Text search Archive database of all patients on CD/DVD (option) or DICOM PACS (option) Thumbnail display of selected exam Document types: Frozen Images, Live Images, 3D data sets, Reports DICOM (option): MPPS (Modality Performed Procedure Step) Storage Commitment Modality Worklist Store Print (B/W and color) Export Functions: Archiving to CD/DVD (option), network Copy to CD/DVD (option), USB-drive, External HDD Format: BMP, AVI, html, BK3d IMAGE MARKINGS Image scale Puncture lines Matrices (user-defined) Brachy grid IMAGE ANNOTATIONS Alphanumeric Adjustable annotation arrow Labels and comments (user-defined libraries) Bodymarks (user-defined libraries) Patient and hospital IDs Real-time clock showing date and time CINE Cine Frames: >3000 Cine Doppler: >20 min Loop Function Clip: Up to 8 hours in chapters of max. 5 min COLOR FLOW MAPPING CFM Modes: Velocity, Variance, Velocity + Variance Sample: Max. 512 points Pulse repetition frequency: 0.2 12 khz Wall filter: Digital filter. Cutoff frequency 1 10% of PRF Detectable speed: 0.1 cm/sec 8.6 m/sec (0 60º) Display: 4096 colors; 8 different color scales Color Doppler interleave factor: 64 lines STEERABLE DOPPLER Angle: up to 40º (±20º) PULSED WAVE DOPPLER Sample volume size: 1 20 mm Units: cm/s or khz Flow inversion: Yes Flow offset: Yes Pulse repetition frequency: 1 15 khz Wall filter: Digital filter. Cutoff frequency 1 20% of PRF Detectable speed: 0.1 cm/sec 10.8 m/sec (0 60º) Display: B/W or color FFT spectra, 256 levels Frequency resolution: Max. 5.2 Hz (PRF = 1 khz) Time resolution: Max. 4msec Angle correction: 1º steps Doppler audio output: max. 1 W POWER DOPPLER DIRECTIONAL POWER DOPPLER Sample: Max. 512 points Pulse repetition frequency: 0.2 12 khz Wall filter: Digital filter Display: 256 colors. 11 different color scales MEASUREMENT FACILITIES Trackball (point, move, measure) Trackpad (point, move, measure) Remote control (point, move, measure) (1202-3 only) Pro Packages: Urology, Brachytherapy, Surgery, General (including Vascular), OB/GYN CONNECTION POSSIBILITIES Transducers: 3 active sockets: 2 for linear and convex array transducers 1 for 360º and single-element transducers (1202-1 and 1202-3 only) Signal output (1202-1 only): Audio (stereo line level); Video (composite color, S-video), DVI-I (60Hz) Signal input: Audio (stereo line level); Video (composite color, S-video) (not on 1202-2) Image storage: Internal hard disk, DVD±RW (option) or USB storage device, digital B&W printer (option), digital color printer (option) Communication: Expandable to 8 x USB 2.0 (5 built in), 10/100 Ethernet DICOM network (option) Remote control: Low power, short-range wireless connectivity (1202-3 only) Remote control is for future release 6 Type 1202 Product Data BK Medical 2010

Specifications Flex Focus 1202 cont. POWER SUPPLY Complies with requirements for Class 1 (protective earth) devices of EN/IEC 60601-1[1] and UL 60601-1:2003 [4] Voltage: 100-230V AC Frequency: 50 60 Hz Power consumption: 300VA total (500 Btu/h) REMOTE CONTROL 2 AA batteries (not supplied with remote control) Average battery life 60 days BATTERY PACK Complies with requirements for Class 1 (protective earth) devices of EN/IEC 60601-1[1] and UL 60601-1:2003 [4] Contains two or four rechargeable 14.4 V lithium ion batteries Voltage: 14.4 V Capacity: 6600 mah Continuous scanning time: 3 hours (with 4 batteries) Charge time: 2 hours 45 min (with scanner turned off) Status display indicates remaining uptime Battery lifespan: Min. 300 full recharge and discharge cycles NOISE Fan noise during operation: <35 dba ENVIRONMENTAL LIMITS Operating temperature: +10 to 40 ºC (+50 to 104 ºF) Storage temperature: -25 to +60 ºC (-13 to +140 ºF) Storage temperature (batteries only): -20 to +60 ºC (-4 to +140 ºF) Operating/storage humidity: max 80% RH Operating pressure: 700 1060 hpa (normal atmospheric pressure) Remote Control as for scanner except: Storage temperature:-25 to +70 C (-13 to +158 F) Watertight immersion temperature: Max +40 C (+104 F) Watertight immersion time: Max 15 hours per 24 hours DISINFECTION SCANNER Chemical resistance during disinfection: Wiping with: Sodium hypochlorite up to 2% in water Chlorhexidine gluconate 5% in water Chlorhexidine 1.5% and cetrimide 15% in water Chlorhexidine 0.5% in ethanol 70% Glutaraldehyde 2% solution Ethanol 70% in water Isopropanol 70% in water REMOTE CONTROL Chemical resistance during disinfection: Immersion for less than 10 minutes in each hour in: Isopropanol 70% in water APPROXIMATE DIMENSIONS With Mobile Keyboard Docks UA1210 and UA1214: Scanner height: 1350 1602 mm (adjustable) Keyboard height: 745 1055 mm (adjustable) Width: 519 mm (including wheel base) Width: 351 mm (scanner and control panel) Depth: 595 mm Weight: 49 kg (excluding transducers and printer) (UA1210 only) Weight: 57 kg (including battery pack, excluding transducers and printer) (UA1214 only) Weight: 7 kg (scanner unit only) Battery weight: 0.7 kg (per battery) With Mobile Touch Docks UA1810 and UA1814: Scanner height: 1350 1602 mm (adjustable) Keyboard height: 745 1055 mm (adjustable) Width: 519 mm (including wheel base) Width: 351 mm (scanner and control panel) Depth: 595 mm Weight: 46 kg (excluding transducers and printer) (UA1810 only) Weight: 54 kg (including battery pack, excluding transducers and printer) (UA1814 only) Weight: 7 kg (scanner unit only) Battery weight: 0.7 kg (per battery) ELECTROMAGNETIC COMPATIBILITY Complies with requirements for Class A devices of EN/IEC 60601-1-2 [2] SAFETY Complies with EN/IEC 60601-1[1], EN 60601-2-37[3], UL60601-1[4], and CSAC22.2 No. 601.1[5] APPROVALS UL International DEMKO (CB certification) UL Listed MARKET CLEARANCE USA - FDA, Market Clearance Canada Health Canada, License (pending for 1202-3) EU - Notified Body (DGM), CE certification Japan - PMDA, License (pending for 1202-3) MANUFACTURER BK Medical ApS Mileparken 34 DK-2730 Herlev Denmark REFERENCES [1] EN 60601-1:1990 + A1:1993 + A2:1995 + A13:1996 Medical electrical equipment. Part 1: General requirements for safety. [2] EN 60601-1-2:2001 + A1:2006 Medical electrical equipment Part 1-2: General requirements for safety. Collateral standard: Electromagnetic Compatibility-Requirements and tests. [3] EN 60601-2-37:2001+ A1:2005 + A2:2005 Medical electrical equipment Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment. [4] UL 60601-1:2003 Medical Electrical Equipment Part 1. General Requirements for safety. [5] CSA C22.2 No. 601.1 M90 Medical Electrical Equipment Part 1. General Requirements for safety. [6] EN60601 1 1:2001 Medical electrical equipment Part 1-1: General requirements for safety. Collateral standard: Safety requirements for medical electrical systems. TRADEMARKS DICOM is the registered trademark of the National Electrical Manufacturers Association for its standards publications relating to digital communications of medical information. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. STERRAD is a registered trademark of Advanced Sterilization Products (ASP), a Johnson & Johnson Company. STERIS and STERIS SYSTEM 1* are registered trademarks of STERIS Corporation. IQPAC is a trademark of BK Medical ApS. * STERIS SYSTEM 1 is not market cleared in the USA. ** The scanner s frequency range may exceed current transducers frequency range Remote control is for future release Type 1202 Product Data BK Medical 2010 7

Ordering Information There are 5 versions of the Flex Focus 1202 available for order: Flex Focus 200 Flex Focus with basic functionality (only available in some countries) 1202-2 Flex Focus 200 Surgery basic surgical scanner with limited transducer range 1202-7 Flex Focus 400 mid-range color scanner 1202-1 Flex Focus 400 Anesthesia dedicated to regional anesthesia 1202-4 Flex Focus 700 high-end surgical scanner with touch screen 1202-3 Configurations Options and Accessories OPTIONS Included o Optional Not available Flex Focus 200 Flex Focus 200 Surgery Flex Focus 400 Flex Focus 400 Anesthesia Flex Focus 700 UA1237 Remote Control (for 1202-3) * UA1220 Backpack to hold printer (requires Mobile Dock) UA4102 Printer start-up kit for 1202 UA1284 DVD (RW) Drive SCANNER UNITS 1202-2 Flex Focus 200 1202-7 Flex Focus 200 Surgery 1202-1 Flex Focus 400 1202-4 Flex Focus 400 Anesthesia 1202-3 Flex Focus 700 DOCKS UA1210 Mobile Keyboard Dock o o o o o UA1214 Mobile Keyboard Dock with Battery (includes 2 rechargeable batteries) 1 1 1 1 1 UA1211 Keyboard Wall Dock o o o o o UA1283 Keyboard Table Dock o o o o o UA1810 Mobile Touch Dock o o o o o UA1814 Mobile Touch Dock with Battery (includes 2 rechargeable batteries) 1 1 1 1 1 UA1811 Touch Wall Dock * o o o o o FEATURES IQPAC Clip store Video Out UA1205 Picture in Picture o UA1203 Color Doppler (Color Flow Mapping) 1 o UA1298 Pulsed Wave Doppler 1 o UA1222 3D Professional (license) o o UA1207 3D Freehand (license) o o o UA1284-k DVD (RW) Drive kit UA1247 Battery Charger Station ** UA1225 Extra Battery for UA1214 and UA1814 ** (rechargeable Inspired Energy NL2024 lithium ion battery, 14.4 V). IMPORTANT: Must be ordered in sets of 2 or 4 batteries UA1294 UA1295 UA1204 Endo Transducer Holder Endo Transducer Holder Mount Wall-mounted Transducer Holder UA1296 General Transducer Holder * UA1223 Power Cable Holder * UA1202 AO0491 Foot switch (USB) Video cable (Flex Focus to phono and BNC) UA1285 Wheeled transport case UA0964 Flight case (for system shipping) ACCESSORIES INCLUDED BB1756 Flex Focus Type 1202 User Guide, includes Getting Started with the Flex Focus Type 1202 (English) BB1946 Flex Focus Advanced User Guide Type 1202 (English) BB2037 Remote Control UA1237 User Guide (included with UA1237) * BB1564 Care, Cleaning & Safety (English) BB1984 QA0228 User Documentation CD Trackball adjustment tool (for UA1210/UA1214/UA1211/UA1283) ACCESSORIES AVAILABLE UA1206 DICOM (license) o o o o o EQ4072 Printing paper (Sony UPP-110HG) UA1226 Varian Interface (license) o o UA0610 Scanning gel (5 L) TRANSDUCERS WQ0739 Scanning gel (290 ml) Basic Transducer Support: 8667, 8670, 8808, 8808e, 8811, 8819, 8820e, 8823, 8827, 8830 Enhanced Transducer Support: 1850, 2050, 2052, 8662, 8802, 8809, 8818, 8848, 8870 Anesthesia Transducer Support: 8670, 8809, 8811, 8816, 8823, 8827, 8830, 8870 Basic Surgical Transducer Support: 8666-RF, 8815, 8816 Complete Surgical Transducer Support: All transducers 1 Optional only available in some countries * For future release ** Optional only available in some countries No DVD (RW) option Requires UA1220 or UA1214 3D Scanning Accessories UA0513 Magnetic wheel mover for 8808, 8818 & 8848 transducers EL4036 3D mover adaptor UA0510 Adapter ring for 8848 UA0511 Adapter ring for 8808 UA0512 Adapter ring for 8818 UA0515 Pullback adapter for 8848 UA0516 Pullback adapter for 8818 UA0553 Variable friction support arm For scanners without dock and with two transducers Other language versions available Requires EL4036 8 Type 1202 Product Data BK Medical 2010

Technical Drawings All measurements are in mm. 1202 with Mobile Keyboard Dock UA1210 1202 with Keyboard Table Dock UA1283 Type 1202 Product Data BK Medical 2010 9

1202 with Mobile Battery Keyboard Dock UA1214 1202 with Keyboard Wall Dock UA1211 BK Medical Mileparken 34 DK-2730 Herlev Denmark Tel.: +45 4452 8100 Fax: +45 4452 8199 www.bkmed.com A wholly owned subsidiary of Analogic Corporation Information may be subject to change without notice

1202 with Mobile Touch Dock UA1810 1202 with Touch Wall Dock UA1811 Type 1202 Product Data BK Medical 2010 11

1202 with Mobile Touch Dock with Battery UA1814 BK Medical Mileparken 34 DK-2730 Herlev Denmark Tel.: +45 4452 8100 Fax: +45 4452 8199 www.bkmed.com A wholly owned subsidiary of Analogic Corporation Information may be subject to change without notice