Updating Your Firmware



Similar documents
Tutorial How to upgrade firmware on Phison S5 controller MyDigitalSSD

Using GIGABYTE Notebook for the First Time

Using GIGABYTE Notebook for the First Time

Important Note Regarding Your Blu ray Drives

Using GIGABYTE Notebook for the First Time

Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment

Using GIGABYTE Notebook for the First Time

SSD Firmware Update Utility Guide

DESKTOP. Internal Drive Installation Guide

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

User Guide Software Version 2.1.0

XConsole GUI setup communication manual September 2010.

Dexcom Update Tool: Instructions for Use

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

SSD Guru. Installation and User Guide. Software Version 1.4

HDD Password Tool. User s Manual. English

How To Set Up A Hard Drive With A Harddrive With A 2Gb Hard Drive (I386) And 2Gb Drive (Amd64) On A Hardrive (I219) (Iee) (Amd66) (Ai219

ReadyNAS OS 6 Desktop Storage Systems

BIOS Update SOP. Updating BIOS under Windows Mode for Intel Series (PXX/ZXX/X79)... 2

VIA RAID Installation Guide

Using GIGABYTE Notebook for the First Time

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

WA1791 Designing and Developing Secure Web Services. Classroom Setup Guide. Web Age Solutions Inc. Web Age Solutions Inc. 1

WA2102 Web Application Programming with Java EE 6 - WebSphere RAD 8.5. Classroom Setup Guide. Web Age Solutions Inc. Web Age Solutions Inc.

Using AORUS Notebook for the First Time

Guide to SATA Hard Disks Installation and RAID Configuration

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

Industrial Flash Storage Trends in Software and Security

Using GIGABYTE Notebook for the First Time

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Guide to SATA Hard Disks Installation and RAID Configuration

ESATA PCI CARD. User s Manual

Pleiades USB/LAN. User Manual. & Installation Guide. External Storage Enclosure for 3.5 Hard Drive. v1.1

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

Guide to SATA Hard Disks Installation and RAID Configuration

Data Lifeguard Tools. Software Manual

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

Using GIGABYTE Notebook for the First Time

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Time Stamp. Instruction Booklet

istar User Manual for Comsol USB Flash Drive


IBM System x3400 and x3500 servers SATA backup device Not seen when attached to SATA onboard controller port

NAS HARD DRIVE ENCLOSURE USER MANUAL. S T O R E n S H A R E MUSIC DATA PHOTO MOVIE

USB FLASH DRIVE. User s Manual 1. INTRODUCTION FEATURES SPECIFICATIONS PACKAGE CONTENTS SYSTEM REQUIREMENTS...

User Manual. Thermo Scientific Orion

Intel Rapid Start Technology User Guide for UEFI Mode

Configuring ThinkServer RAID 100 on the Lenovo TS130

Shearwater Research Dive Computer Software Manual

Upgrading Client Security and Policy Manager in 4 easy steps

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Imation LOCK User Manual

Using GIGABYTE Notebook for the First Time

Yamaha 01V96 Version2 Upgrade Guide

Print Server Application Guide. This guide applies to the following models.

Intel Data Migration Software

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

Centurion PLUS CPC4 Download Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

Fujitsu SCSI Scanner Installation Procedures Windows 95\98\98SE\ME\2000\XP\Vista

Firmware Update Instruction Manual

This software will update your Samsung Galaxy S II to Android software version GB28.

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

Hosting Users Guide 2011

Allworx Installation Course

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

Guide to SATA Hard Disks Installation and RAID Configuration

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

M2GO & M1 Operating System Installation

Intel Rapid Storage Technology

Configuring ThinkServer RAID 100 on the TS140 and TS440

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

User Manual. 2 Bay Docking Station

Hi-Speed USB Flash Disk User s Manual Guide

1. System Requirements

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

Windows XP.. ELITE Firmware Update procedures.. v1.41

Serial ATA 2 Ports PCI Host

Yale Software Library

VIA / JMicron RAID Installation Guide

SATA II 4 Port PCI RAID Card RC217 User Manual

How To Configure CU*BASE Encryption

Sky Broadband upgrading your router software

Samsung Magician v.4.5 Introduction and Installation Guide

Intel Data Migration Software

PCI ATA 133 RAID Controller Card. User Manual

Wharf T&T Cloud Backup Service User & Installation Guide

Paragon Backup Retention Wizard

PCI SATA + PATA Raid Card

Serial ATA RAID PCI Card

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

The care and feeding of Pythons at the Redmond Zoo. (Using Micro Python and pyboard with Windows)

ATTO ExpressSAS Troubleshooting Guide for Windows

Image Backup and Recovery Procedures

XL-RAID-SATA2-USB. User Manual. v.1.2 (January, 2010)

Firmware & Software update procedures Amicroe TouchTAB IV.

DUKANE Intelligent Assembly Solutions

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Transcription:

Updating Your Firmware WARNING: This firmware update is only valid for OCZ VERTEX Solid State Drives Flashing your Vertex will result in complete data loss. Please back up your drive before proceeding Tip: Testing any SSD under the current Windows operating systems will leave data blocks behind that are no longer valid but have to be erased before the blocks can be re used. If you want to test your SSD, we advise to do this before installing an operating system and then to recondition the drive by running the flash utility to erase all invalid data on the drive. This will restore maximum performance. OCZ Engineering Q2, 2009

Thank you for purchasing an OCZ Vertex SSD. Our firmware updates are designed to enhance the performance of your Vertex. If you would like to update the firmware on your drive to our latest officially released version, this guide tells you how to do it. You can check the firmware version number in the device manager or BIOS. Before you begin: Make sure you have a jumper handy If you have data on your Vertex that you do not want to lose, don t forget to back it up before updating the firmware The Vertex you are updating will have to be connected as a spare drive to a notebook or desktop with a functioning OS Confirm the capacity of your drive (it is listed on the back of the drive) Make sure your system is stable. Just like flashing a BIOS, it is best to do so at stock CPU/RAM/GPU speeds You are now ready to begin: 1. Boot your computer with your old Hard Disk Drive (HDD) 2. Download the latest firmware for VERTEX SSD from www.ocztechnology.com 3. Extract (unzip) the downloaded file and remember the location of extracted files and folders. 4. Turn off the computer. 5. Install the jumper to set the drive to factory mode (Appendix I, II) 6. The drive needs to be connected to any SATA ports 0~3 on Intel SATA controllers (Appendix III) 7. Turn on the computer, enter the CMOS setup and change the SATA controller to IDE mode. 8. Save the CMOS settings and exit the BIOS setup to reboot the computer. Flashing the Firmware: (The following example is for 120GB VERTEX SSD) 1.Turn on the computer and follow the instructions below. If you are using Windows VISTA, you will need to turn off UAC (User Account Control). 2.Double click the unzipped folder: 3. You will see the following folders; in the case of the 120GB drive, please double click the 120GB folder.

4. The folder should contain the following files: 5. Double click on the start file to run the firmware update program the following screen will appear: 6. Click on the OK button to start the program. The drive will now address all data blocks to re flash them. 7. In the unlikely event that you encounter any hanging or freezing during the flashing or the VERTEX, please repeat the flashing process.

8. Remove the jumper from the VERTEX and click on the OK button to confirm normal mode of the VERTEX. 9. Next, simply click on the OK button. Congratulations, you have completed the flashing process.

10. To exit the program, press Cancel. Shut down your computer. (If you want to flash multiple VERTEX SSDs, follow step 1~10 again.) Verification of Successful Firmware Update: a. Turn off your computer b. Verify that the jumper has been removed from the VERTEX SSD. c. Restart the computer and enter the CMOS setup to restore the original SATA settings. On the Fly Verification of Firmware Update: (Successful flashing of the firmware can be verified without disconnecting or rebooting) a. After completing the flash procedure, simply remove the jumper and click OK at the prompt. b. Open the control panel/system/hardware/device manager c. Right click on disk drive / scan for hardware changes 2 times (Windows XP). The firmware version number should now appear next to the drive in the device manager. In the example version the number should be v1.10 Your drive is now ready for the installation of the OS.

Hot Plugging Method This method is useful only when steps 1 10 are not working. This method is also useful when your computer does not recognize the SSD or hangs on boot. How to Flash the VERTEX SSD a. Follow steps 1~5 except for the SSD connection. b. Connect the SSD (jumpered) as shown in Appendix III. c. Then, press the OK button as shown in step 6. d. Program starts automatically. e. Remove the jumper from the SSD when Change the jumper setting screen pops up. d. Press the OK button as shown in step 8. e. Press the OK button as shown in step 9. f. Press Cancel button as shown in step 10. g. Disconnect the SSD from your computer. h. You have completed the flashing process of the Vertex. i. Close all programs, shut down the computer, and restart. j. Please verify correct execution of the flashing.

APPENDIX I (top), II (bottom) Firmware update Jumper Jumper installed

APPENDIX III. SATA Power and data cable connection (Notebook is different) SATA POWER Cable SATA DATA Cable *For Notebook users, please refer to the manufacturer s notebook manual for the disk drive location.

Firmware Version History Version 0112 (Feb. 2009) (Description: Basic I/O optimized drive with SMART error logging) Version 1199 (Feb. 2009) (Description: Enhanced performance I/O optimized drive) Internal "write join" was implemented for better performance SMART basic features can be performed without error log monitoring (to reduce overhead of log data collection) ATA power management commands (IDLE, STANDBY, SLEEP) are enabled for compatibility (Actually these are dummy, while SATA based Power Management is fully supported) Supports runtime bad block handling Improved power management Improved NAND handling Enabled PIO mode data transfer Version 1275 (March, 2009) (Description: Improved raid 0 mode performance) Performance is improved when drive is installed on RAID0 mode host Maximum LBA number is modified according to the JEDEC standard Modifications of internal data structure used by FW (stamp) Improved write joining Improved FPDMA transfer mode Version 1.10 (April 7, 2009) Feature Add : TRIM support is added Apple Mac Pro sleep/wake up support added Updater improved Bad block management function improved