New Control Strategy To Improve Power Quality Using A Hybrid Power Filter



Similar documents
A new approach for three-phase loads compensation based on the instantaneous reactive power theory

Control Strategy for Three Phase Shunt Active Power Filter with Minimum Current Measurements

How To Improve Power Quality

MODELING AND SIMULATION OF A THREE-PHASE INVERTER WITH RECTIFIER-TYPE NONLINEAR LOADS

MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: [633] [Choudhary, 3(12): December, 2014] ISSN:

A bidirectional DC-DC converter for renewable energy systems

Harmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

Product Data Bulletin

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

The design and performance of Static Var Compensators for particle accelerators

High Intensify Interleaved Converter for Renewable Energy Resources

How To Improve Power Quality

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Design Considerations for an LLC Resonant Converter

The Grid Interconnection of Renewable Energy at Distribution Level with the Features of High Power-Quality Improvement

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

NEURO-FUZZY BASED POWER QUALITY IMPROVEMENTS IN A THREE PHASE FOUR WIRE DISTRIBUTION SYSTEM USING DSTATCOM

Lab 3 Rectifier Circuits

An Efficient AC/DC Converter with Power Factor Correction

FOUR LEGGED ACTIVE POWER FILTER COMPENSATION FOR A UTILITY DISTRIBUTION SYSTEM

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

University of Cape Town

New Pulse Width Modulation Technique for Three Phase Induction Motor Drive Umesha K L, Sri Harsha J, Capt. L. Sanjeev Kumar

POWER QUALITY IMPROVEMENT OF GRID INTERCONNECTION WITH RENEWABLE ENERGY SOURCES AT DISTRIBUTION LEVEL

A Novel Three-Phase Active Power Filter

Analysis of AC-DC Converter Based on Power Factor and THD

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition

v v v Keywords-- Power Quality, Shunt active filter, Indirect current control, ANN control

A Low Cost Power Quality and Energy Savings Laboratory for Undergraduate Education and Research

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

A COMPERATIVE PERFORMANCE ANALYSIS OF BRIDGELESS PFC BOOST CONVERTER WITH THE CONVENTIONAL CONVERTER

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

dspace DSP DS-1104 based State Observer Design for Position Control of DC Servo Motor

Bridgeless PFC Implementation Using One Cycle Control Technique

POWER QUALITY ISSUES IN A STAND-ALONE MICROGRID BASED ON RENEWABLE ENERGY

Design and Simulation of Soft Switched Converter Fed DC Servo Drive

Lecture 18: Common Emitter Amplifier. Maximum Efficiency of Class A Amplifiers. Transformer Coupled Loads.

Smart Grid and Renewable Energy Grid Integration. Jian Sun, Professor and Director Department of ECSE & Center for Future Energy Systems

Zero voltage drop synthetic rectifier

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Electrical Resonance

Closed Loop PWM Control for Induction Motor Drive Using Dual Output Three Phase Inverter

Line Reactors and AC Drives

Development of an Electrical Power Quality Monitor Based on a PC

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution

A Zero-Voltage Switching Two-Inductor Boost Converter With an Auxiliary Transformer

DC/DC BUCK Converter for Renewable Energy Applications Mr.C..Rajeshkumar M.E Power Electronic and Drives,

A bidirectional, sinusoidal, high-frequency inverter design

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

Three phase circuits

Scholars Research Library

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

How To Simulate A Multilevel Inverter

Chapter 4 AC to AC Converters ( AC Controllers and Frequency Converters )

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

Considering the effects of UPS operation with leading power factor loads

See Horenstein 4.3 and 4.4

Keywords: Electric circuits, passive circuits, active circuits, voltage source inverter, reactive power theory, active filters.

Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions

How To Make A Power Amplifier For A Mobile Phone

Since any real component also has loss due to the resistive component, the average power dissipated is 2 2R

MULTI-LEVEL INVERTER WITH DC LINK SWITCHES FOR RENEWABLE ENERGY SOURCES

HARMONICS AND HOW THEY RELATE TO POWER FACTOR. W. Mack Grady The University of Texas at Austin Austin, Texas 78712

LOW-VOLTAGE three-phase four-wire electrical distribution

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

Current and Temperature Ratings

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

Analysis and Experimentation of Interleaved Boost Converter with Ripple Steering for Power Factor Correction

Control Development and Modeling for Flexible DC Grids in Modelica

RLC Series Resonance

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

EXPERIMENT 1 SINGLE-PHASE FULL-WAVE RECTIFIER AND LINEAR REGULATOR

Implementation of High Step-Up Solar Power Optimizer for DC Micro Grid Application

Measurement of Capacitance

The D.C Power Supply

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Parameter Settings for PowerFlex Drives Using Sine Wave Filters, dv/dt Filters, and Adjustable Voltage

Novel Loaded-Resonant Converter & Application of DC-to-DC Energy Conversions systems

Inrush Current. Although the concepts stated are universal, this application note was written specifically for Interpoint products.

Current Probes, More Useful Than You Think

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Chapter 12: Three Phase Circuits

THE development of new methods and circuits for electrical energy conversion

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Transcription:

New Control Strategy o Improve Power Quality Using A Hybrid Power Filter S. P. Litrán, P. Salmerón, R. S. Herrera, and J. R. Vázquez Department of Electrical Engineering Escuela Politécnica Superior, University of Huelva Ctra. de Palos de la Frontera s/n 21819, Palos de la Frontera. Huelva (Spain) Phone: 0034 959 217585, Fax number: 0034 959 217304 e-mail: salvador@uhu.es; patricio@uhu.es; reyes.sanchez@die.uhu.es; vazquez@uhu.es Abstract. A new control algorithm for a hybrid power filter constituted by a series active filter and a passive filter connected in parallel with the load is proposed. he new control strategy is based on the dual formulation of the vectorial theory of electric power, so that the signal injected by the active filter is able to compensate the reactive power and the harmonics of the load current. o verify the developed theoretical analysis, the control strategy was verified by means of an experimental prototype. he results to verify the effectiveness of the proposed control algorithm are presented. Key words Harmonics, series active power filter, hybrid power filters, power quality, compensation, pq theory. 1. Introduction he presence of harmonics in the power electrical systems is the main cause of the electrical wave pollution that so many problems carry. he indiscriminate increase of non-linear loads has given rise to investigation into new compensation equipment based on power electronics. he main design target for this equipment is the elimination of the harmonic present in the system and a reduction in the power reactive. Depending on the application type, series or parallel configurations or combinations of active and passive filters have been proposed [1,2]. When the objective is to compensate current-source nonlinear loads, named harmonic current source (HCS), a shunt configuration as compensation equipment is used. o eliminate harmonics in this kind of load, a shunt passive filter have traditionally been used, mainly due to their low cost and minimal maintenance requirements. As a result, this has been the adopted solution for systems with considerable power. However, shunt passive filters are not free from problems [3] of which the most significant are: -he compensation characteristics depend strongly on the system impedance as the filter impedance has to be smaller than the source impedance in order to eliminate source current harmonics. -Overloads can happen in the passive filter since they can finish being harmonics drain of other connected nonlinear loads near the point of common coupling, PCC. - hey are not appropriate for loads of variable operation, since, on one hand, they are designed for a specific reactive power, and on the other, the variation in the values of the load can detune the filter. -Series and/or parallel resonances with the rest of the system can appear. On the other hand, it is possible to improve the behavior of passive filters in parallel connection by including a series active filter in the system. his improves the compensation characteristics of the passive filter [4]. his topology is shown in Fig. 1, where v c is the voltage that the active power filter should generate to achieve the objective of proposed control algorithm. v S L S v PC v C C f Non linear load Fig. 1. Series active filter with shunt passive filter Different techniques have been applied to obtain the control signal to the active filter series. One of them is to generate a proportional voltage to the harmonic of the L f v L

source current [5]. However, the choice of the appropriate value for the proportional constant is an unsolved question since it is related to the value of the passive filter and the source impedance. Another technique of propose control is to generate a voltage waveform like to the voltage harmonic in the side load but in opposition. his strategy only prevents the shunt passive filter depending on the source impedance, [6]. Later, a control strategy that combining both the above have been used [6], but they continue to suffer the difficulty of an indefinite value for the constant k in most of the applications. A recent strategy proposes that the active filter generates a voltage which compensates the reactive power of the passive filter and load set and allows elimination of the current harmonics [7]. here, the control target is to achieve constant power in the source side. In this paper a new control strategy based on the dual formulation of the vectorial theory of electric power [8-10] is proposed. It allows the voltage that the active filter has to generate to be determined so as to attain the compensation objective of achieving is to obtain a sinusoidal voltage in PCC. With this strategy it is possible to improve the compensation characteristics of the passive power filter without depending on the system impedance, since the set load-filter would have a behavior very similar to the one of a resistive element. It also avoids the danger that the passive filter will behave as a harmonic drain of near loads, and likewise the risk of possible series and/or parallel resonances with the rest of the system. In addition, the compensation is also possible for variable loads, not affecting some possible detuning of the passive filter. he system has been verified by means of an experimental prototype, applied to a nonlinear threephase load. he experimental results are presented. 2. Control strategy In a three phase system, the coordinates transformation from the phase reference system a-b-c, to --0 coordinates of the voltages and currents can be obtained by v 0 1 2 1 2 1 2 va 2 = v 1 1 2 1 2 vb (1) 3 v 0 3 2 3 2 v c i 0 1 2 1 2 1 2 ia 2 = i 1 1 2 1 2 ib (2) 3 i 0 3 2 3 2 i c he real instantaneous power in the frame --0 is calculated as follows p 3 φ ( t) = v i v i v0 i0 (3) his power can be written by means of p 3 φ ( t) = p p0 (4) Where p is the real instantaneous power without the zero sequence real instantaneous power and given by p = v i v i (5) his power can be written in vectorial form by means of the dot product p = i v (6) Where i is the transpose of the current vector in coordinates - [ i i ] i = (7) And v is voltage vector in the same coordinates [ v v ] v = (8) In the equation of the real instantaneous power (4), p 0 is the zero sequence real instantaneous power, determined as follows p = (9) 0 v0 i0 In a three wire system the zero sequence real instantaneous power is null. he imaginary instantaneous power is defined by the equation q =ˆ v i v i (10) his can be expressed by means of the dot product q = i v (11) Where i is the transpose of the current vector perpendicular to i and defined by, [ i i ] i = (12) According to these terms, both power variables previously defined can be expressed by p = q i i v (13)

By means of the current vectors and the instantaneous real and imaginary power, the voltage vector can be calculated as, p q v = i i 2 2 (14) i i instantaneous power to be calculated, obtaining its mean value with a low pass filter (). his power is consumed by the set passive filter and load. he mean power is divided by the square of rms value of fundamental current component. In order to achieve the desired compensation target, the current and the voltage source must be proportional v = R i (15) S e S1 Where i S1 is fundamental current component in the supply side and R e is the equivalent resistance which is defined by the following expression, i S v L Fundamental component calculation a-b-c - i v i 1 i 2 1 p Calculation p P I 2 1 - p * P R e = (16) 2 I 1 In this equation I 2 1 is the square rms value of the fundamental harmonics of the current vector and P is the active power consumed by the load. i 2 i 2 q Calculation q * herefore the voltage at the point of common coupling after compensation will be as follows, P v (17) PC = i 2 1 I1 p * q * i v * - v * a-b-c he load voltage is given by v p q L = i i 2 2 i i (18) Where p is the real instantaneous power and q is the imaginary instantaneous power of the load. he reference voltage of compensation injected by the active power filter is calculated as * v = v PC v L (19) hus, the compensation voltage considering equations (17) and (18) is given by v P p * = i i 2 2 2 I1 i i q (20) When the active power filter supplies this compensation voltage, the set load and compensation equipment will behave very similar as a resistance of value R e. Fig. 2 shows the control scheme to calculate the compensation voltage for the active filter. he voltage vector in the side of the load and the source current vector are the input signals. By means of a calculation block the components - of the vectors v e i can be determined. he product of these vectors allows the real Fig 2. Control scheme he fundamental component is obtained by means of a block with the scheme shown in Fig. 3. he source current vector is multiplied by sinωt and cosω,t where ω is the fundamental frequency in rad/s. he mean values of the results are obtained by two low pass filters and aided by the function sinωt and cosωt. his allows us to obtain the fundamental component of the current vector; on the other hand, the real instantaneous power is divided by i 2. his result is multiplied by the current vector i, which allows us to determine the first term of the compensation voltage of the equation (20). sinωt i cosωt Fig. 3. Calculation fundamental component On the other hand, the imaginary instantaneous power is obtained and divided by i 2 and finally multiplied by the current vector i. It allows the second term in the 2 i 1

v a L s a v b v c L s L s b c Non linear Load C rf C rf C rf L rf L rf L rf L 5 L 5 L 5 L 7 L 7 L 7 C 5 C 5 C 5 C 7 C 7 C 7 Fig. 4. Passive filter combined with series active power filter topology. equation for the compensation voltage (20) to be obtained. he control strategy was verified with a model simulated in the platform Matlab-Simulink using the toolbox library of SimPowerSystem. Later an experimental prototype was manufactured. 3. Experimental prototype Fig. 4 shows the scheme of the power circuit. It is a three-phase three-wires system supplied by a sinusoidal balanced three-phase source of 100 V rms with source inductance of 5 mh. he control was implemented in control and data acquisition cards of general application, compatible with Matlab-Simulink developed by dspace. Real-ime Interface (RI) of dspace together Real ime Workshop (RW) from Mathworks automatically generates real time code on dspace. It allows to program the processor board and to select I/O boards. It is based on the DS 1005 PPC placed in a dspace expansion box. he input board was the DS 2004 A/D and the output board the DS 51001 DWO from dspace. he developed experimental prototype is shown in Fig. 5. he converter consists of an IGB bridge, type SKM50GB123 from Semikron. In the dc side two capacitors with 100 V are connected. In the ac side a LC filter has been included to eliminate the high frequency components. his set is connected to the power system by means of three single phase transformers of turn ratio 1:1. he passive power filter is making by two LC branches tuning to the 5 th and 7 th harmonics. he values of each passive element are included in the table I. ABLE I. Passive elements values Source Ls= 3.4 mh Pasive filter L 5 = 13.5 mh C 5 = 30 µf L 7 =6.75 mh C 7 = 30 µf Ripple filter L r = 13 mh C r = 50 µf he non linear load consists of a non controller three phase rectifier with an inductance of 55 mh and a resistance of 50 Ω connected in the dc side. Fig 5. Experimental prototype Fig. 6 shows the load current and voltage of the phase a, with the system without compensating. his waveform is obtained with an oscilloscope type Wavesurfer 424 from LECROY. he HD of the current measured with the power quality analyzer Fluke 43 is 21.5% and the voltage HD 11.2%. he power factor measured is 0.96.

For the phase b and c, similar results of HD and power factor was measured. Voltage in connection point Source current When the series active filter is connected, the HD of the source current falls to 1.0%. he waveform is shown in Fig. 8. Now, the power factor rises to 0.998. his allows us to verify the proposed control improvement in the compensation characteristic of the passive filter and it practically achieves unity power factor. he HD of the voltage in the PCC is 1.35% and the waveform is shown in Fig. 8 with the phase current. Fig 6. Voltage and current source, phase a. System without compensating Fig. 7 shows the source current and voltage in the connection point when the shunt passive power filter is connected. his current and voltage have a HD of 5.1% and 4.3% respectively. he passive power filter was only designed to compensate the source current harmonics; the reactive power was not taken into account. he power factor of the set load and passive filter is 0.86. 4. Conclusions A new control algorithm for a series active filter has been proposed. he control strategy is based on the vectorial theory of electric power. he new control approach achieves the following targets: - he compensation characteristics of the hybrid compensator do not depend on the system impedance. - he hybrid power filter and load set are a behavior very similar to the one of a resistive element. his fact eliminates the risk of overload due to current harmonics of non linear loads close to the compensated system. Voltage in connection point Source current Fig 7. Voltage and current source, phase a, in the system with passive power filter - his compensator can be applied to loads with random power variation as it is not affected by changes in the tuning frequency of the passive filter. Furthermore, the reactive power variation is compensated by the series active filter. - Series and/or parallel resonances with the rest of the system are avoided because compensation equipment and load are behavior resistive. herefore, with the proposed control algorithm, the hybrid power filter improves the compensation features of the passive filter and the power factor of the load. he system has been verified by means of an experimental prototype, applied to a non-linear threephase load. he experimental results are presented. his fact has allowed verification of the theoretical analysis developed. Voltage in connection point Source current Fig 8. Voltage and current source, phase a, in the system with the hybrid power filter Acknowledgement his work is part of the projects "A new technique to reduce the harmonic distortion in electrical systems by means of equipment of active compensation", ref. DPI2004-03501, sponsored by the Comisión Interministerial de Ciencia y ecnología, CICY, del

Ministerio de Ciencia y ecnología of Spain, and Design and implementation of a new equipment of active compensation with series connection for the improvement of the electrical waveform quality, ref. P06-EP-02354, sponsored by the Consejería de Innovación, Ciencia y Empresa de la Junta de Andalucía, of Andalucía, Spain. References [1] F. Z. Peng and D. J. Adams, Harmonics sources and filtering approaches, in Proc. Industry Aplications Conference, October 1999, Vol, 1, pp. 448-455 [2] H. Akagi, Active harmonic filters, Proceedings of the IEEE Volume 93, Issue 12, Dec. 2005 Page(s):2128 2141 [3] J.C. Das, Passive Filters-Potentialities and Limitations, IEEE rans. on Industry Applications, Vol. 40, no. 1, January 2004, pp. 232-241. [4] F. Z. Peng, H. Akagi, A. Nabae, A novel harmonic power filter, in Proc. IEEE/PESC, April, 1988, pp. 1151-1159. [5] F. Z. Peng, H. Akagi, A. Nabae, A new approach to harmonic compensation in power systems-a combined system of shunt passive and series active filters, IEEE rans. Industry Applications. Vol, 26, no. 6, Nov/Dec 1990, pp. 983-990 [6] Z. Wang, Q. Wang, W. Yao and J. Liu, A series active power filter adopting hybrid control approach, IEEE rans. Power Electronics, vol. 16, no. 3, May 2001, pp. 301-310 [7] Y. S. Kim, J. S. Kim and S. H. Ko, hree-phase hree- Wire Series Active Power Filter, which Compensates for Harmonics and Reactive Power, IEE proc. Electr. Power Appl., Vol, 151, no. 3, May 2004, pp. 276-282. [8] F. Z. Peng, J. S. Lai, Generalized instantaneous reactive power theory for three phase power system, IEEE rans. Instrum. Meas. 1996, 45, (1), pp. 293-297. [9] Herrera, R. S.; Salmerón, P.; Kim, H.; "Instantaneous Reactive Power heory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental Results", IEEE ransactions on Industrial Electronics, Vol. 55, No. 1, Jan-2008, pp: 184-196 [10] P. Salmerón, R. S. Herrera, J. R. Vázquez, Mapping matrices against vectorial frame in the instantaneous reactive power compensation, IE Electric Power Applications, Volume 1, Nº 5, September 2007, pp. 727 736.