Ozone Generator Manual



Similar documents
ENMET Corporation PO Box 979 Ann Arbor, MI ENG 97D STAND-ALONE MANUAL. Manual Part Number MCN-389, 01/21/08

EX-5175-EC Sensor/Transmitter Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Ceiling Mount Air Handler Manual

PALLET JACK TON

SINGLE STAGE INLINE FIRE PUMP

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Global Water Instrumentation, Inc.

Bottom Loading Water Dispenser

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

Panini Maintenance Program My Vision X STANDARD WARRANTY-

BroadBand PowerShield. User Manual

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

RGC-IR Remote Gas Calibrator for IR400

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

81000 Series Aluminum Gate Valve Installation and Repair Manual

Mini-led spotlight with magnetic base

Instructions and precautions. Fork Height. Visit our website at:

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

LIFT N RACK PRO OPERATING & INSTALLATION GUIDE 5500 Lb. LIFT CAPACITY

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

CHROME FRONT BRAKE MASTER CYLINDER KIT

RT-200 HI-TEST ROPE TESTER

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

PNEUMATIC PLANISHING HAMMER

How To Install A Power Supply (Uplast) With A Battery Pack

MP-4V Heavy Duty Riveter / 39048

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Air Conditioning Systems Warranty Manual. Version 1.8

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

KUSTER ELECTRONIC GAUGES

ExStik TM ph Waterproof Meters

Model 349KLX Remote Display Digital Scale User Instructions

Model SRMD Setra Remote Monitoring Display

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

How To Service A Paper Shredder

Installation Manual DIAPHRAGM WELL TANK

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

M A N U A L

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

HYDRAULIC TABLE CART

tire inflator with pressure gauge

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

OP300S / OP350 2:1 RATIO TRANSFER PUMP

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Installation and Maintenance Instructions

ROTOR LOADER OWNER S MANUAL

STC 3S A Series Solenoid Valves

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Owner s Manual & Safety Instructions

i410/i1010 AC/DC Current Clamp

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Installation and Maintenance Instructions

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

REPAIR AND MAINTENANCE MANUAL

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

Thermistor Thermometer MODEL NO

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Park 250 Brushless Outrunner Instructions

Optical Wireless Mouse. User s Manual

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Owner s Manual & Safety Instructions

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

MaxiMist Spraymate By Earlex

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

VK-250 WARRANTY REGISTRATION FORM

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

3 WATT LED SPOTLIGHT Model No. SLM

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

PAINT SPRAY GUN WASHER

Instructions A Amp AC/DC Current Probe

AIR HYDRAULIC RIVETER

IMPORTANT DOCUMENTATION DO NOT DISCARD!

8 ton air/hydraulic long ram jack

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Transcription:

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 Ozone Generator Manual 80003-118 MCN-282, 05/14/04

Table of Contents 1.0 INTRODUCTION... 1 1.1 Unpack...1 1.2 Check Order...1 1.3 Serial Numbers...1 2.0 OZONE GENERATOR FEATURES SECTION... 2 OPERATION... 3 Detector Tube Pump Operation...3 Checking Output with Ozone Detector Tubes:...3 Tests of Pump Performance...3 Check for Leakage:...4 Correction of Pump Leakage...4 Pump Maintenance...5 Verification of Ozone Output...5 Ozone Output Adjustment:...6 REPLACEMENT PART NUMBERS... 6 WARRANTY... 7 List of Illustrations FIGURE 1: OZONE GENERATOR FEATURES... 2 FIGURE 2: OZONE GENERATOR CALIBRATION CONNECTION... 3 FIGURE 3: GAS DETECTOR TUBE PUMP... 4 FIGURE 4: CUTAWAY VIEW OF PUMP... 4 FIGURE 5: OZONE GENERATOR WITH GAS BAG... 5 FIGURE 6: GAS BAG WITH DETECTOR TUBE... 5 Reference information: NOTE: [important information about use of instrument] CAUTION: [affects equipment] WARNING: [affects personnel safety]

OZONE GENERATOR ENMET Corporation 1.0 Introduction NOTE: All specifications stated in this manual may change without notice. 1.1 Unpack Unpack the OZONE GENERATOR and examine it for shipping damage. If such damage is observed, notify both ENMET customer service personnel and the commercial carrier involved immediately. Regarding Damaged Shipments NOTE: It is your responsibility to follow these instructions. If they are not followed, the carrier will not honor any claims for damage. This shipment was carefully inspected, verified and properly packaged at our company and delivered to the carrier in good condition. When it was picked up by the carrier at ENMET, it legally became your company s property. If your shipment arrives damaged: Keep the items, packing material, and carton As Is. Within 5 days of receipt, notify the carrier s local office and request immediate inspection of the carton and the contents. After the inspection and after you have received written acknowledgment of the damage from the carrier, contact ENMET Customer Service for return authorization and further instructions. Have your Purchase Order and Sales Order numbers available. ENMET either repairs or replaces damaged equipment and invoices the carrier to the extent of the liability coverage, usually $100.00. Repair or replacement charges above that value are your company s responsibility. The shipping company may offer optional insurance coverage. ENMET only insures shipments with the shipping company when asked to do so in writing by our customer. If you need your shipments insured, please forward a written request to ENMET Customer Service. Regarding Shortages If there are any shortages or questions regarding this shipment, please notify ENMET Customer Service within 5 days of receipt at the following address: ENMET Corporation 680 Fairfield Court Ann Arbor, MI 48108 734-761-1270 734-761-3220 Fax 1.2 Check Order Check, the contents of the shipment against the purchase order. Verify that the OZONE GENERATOR is received as ordered. If there are accessories on the order, ascertain that they are present. Check the contents of calibration kits. Notify ENMET customer service personnel of any discrepancy immediately. 1.3 Serial Numbers Each OZONE GENERATOR is serialized. These numbers are on tags on the equipment and are on record in an ENMET database. 1

ENMET Corporation OZONE GENERATOR 2.0 OZONE GENERATOR Features Section See Figure 1 for location of features Feature Flowmeter Air Inlet Port Cal Gas Outlet Port Power Switch Operational Voltage: Description This Flowmeter allows the user to verify and monitor the flow rate of the Ozone Generator. Proper flow rate, approximately 0.5 lpm(liter per minute). Fitting for optional connection of inlet air. Normally ambient room air is used. Fitting for connection of tubing to the Ozone sensing unit or gas bag. Toggle switch 110 VAC 50/60 Hz 220 VAC 50/60 Hz (optional, must specify when ordering) Blue Light Ozone Output Adjustment Glass Tube Flowmeter Air Inlet Port Power Switch Calibration Gas Outlet Port Figure 1: Ozone Generator Features 2

OZONE GENERATOR ENMET Corporation Operation OZONE GENERATOR CALIBRATION KIT: part numbers 04056-0800-2(110 VAC) 04056-0800-3(220 VAC). WARNING: This device is capable of generating ozone at concentrations above its Permissible Exposure Limit (PEL). This instrument should be used in a well ventilated area. The Ozone generator is preset at the factory to produce an output of 0.3ppm of Ozone. See the following procedures for verification and or adjustment. Place the instrument in an upright position. Plug the instrument into an appropriate VAC outlet and turn the instrument on. The factory preset flow rate is 0.5 lpm and ozone out put is 0.3 ppm. Allow the generator to operate for at least 60 minutes for stabilization. Review and understand the operation of the detector tube pump, prior to beginning. Gas Bag Valve: Inlet From Ozone Generator Valve: Outlet To Sample Draw System Ozone Monitor Figure 2: OZONE GENERATOR Calibration Connection Detector Tube Pump Operation Checking Output with Ozone Detector Tubes: Each box of detector tubes includes instructions for use of the pump and tubes, and for reading the tube after sampling. CAUTION: Do not use any other manufacturer s tubes with this pump, or another manufacturer s pump with these tubes. Doing so may result in erroneous reading. Tests of Pump Performance Before making gas concentration determinations, the pump should be checked for proper performance using the leakage test described in the next section. To ensure accuracy and reliability these tests should be performed whenever: The pump is used after an extended idle period In routine use should be repeated after every 10 12 samples. 3

ENMET Corporation OZONE GENERATOR Check for Leakage: a) Insert an unused sealed detector tube in the pump inlet; do not break the tips. b) Line up the guide marks (red dots) on the pump shaft and stopper, and pull the handle back all the way. It locks automatically. c) Wait exactly two minutes; then release the pump handle with a 0ne-quarter turn. d) When the handle is released, the piston should spring back all the way to 0cc. If it does not, the pump is not leak-tight, and the amount of leakage is indicated by the position of the handle as it comes to rest. If there is more than 5cc of leakage in two minutes, the accuracy of any concentration determination will be subject to error. Do not use the pump until this is corrected. a) Insert tube b) Pull handle all the way c) unlock handle Figure 3: Gas Detector Tube Pump Correction of Pump Leakage If excessive leakage is found, it usually takes place either at the pump inlet, or between the piston & cylinder walls. The latter source of leakage is much less likely than the former. Leakage between piston & cylinder can usually be eliminated simply by cleaning and re-lubricating. Leakage at the inlet may result from a poor seal between the detector tube and the rubber inlet tip, or between the flange of the rubber inlet tip and the pump body. To check for leakage at the tip: Carefully reposition the sealed detector tube or replace it with another one, and repeat steps a c leak check. If the leakage persists, it is probably at the flange-body interface, and simply tightening down the inlet clamping may suffice to eliminate it. If tightening the clamp does not work, remove the rubber inlet and examine it for cracks and/or foreign matter on its sealing surface. If it is clean and undamaged, replace it in the pump inlet, and repeat the leak test. If necessary, replace a worn rubber inlet with a fresh one. Figure 4: Cutaway View of Pump 4

OZONE GENERATOR ENMET Corporation Pump Maintenance In normal use, the pump should be taken apart, cleaned and re-lubricated after 100 to 200 samples have been drawn. To disassemble: Unscrew the cylinder and cover Slowly pull the pump and pressure-relief valve from the front and of the pump Clean all the bearing surfaces carefully using non-abrasive wipers and a good degreasing solvent such as trichloroethylene or perchloroethylene. Lubricate all surfaces that make metal-to-metal contact with the special silicone grease supplied with the pump kit. Reassemble the pump carefully, making sure that abrasive particles that could score the walls do not get inside the pump. Verification of Ozone Output Verify, and if necessary, adjust flow rate to 0.5 lpm. After the generator has been on for 60 minutes or longer, open the valves on the gas bag. Next flatten and roll it up to empty as much of the air from the bag as possible. Close one valve and attach the bag to the output port on the generator. Allow the bag to fill partially with ozone, remove it from the generator and empty the bag again, as described above. Reattach the bag to the generator and partially fill. Open the second valve on the bag, insert the end of the detector tube into the valve on the bag and draw a sample. Valve: Inlet Gas Bag Valve: Outlet Figure 5: OZONE GENERATOR with Gas Bag Ozone in from Generator Figure 6: Gas Bag with Detector Tube When sampling cycle is complete, check tube for Ozone concentration. If within 10% of desired output, generator is working properly. If not within 10% of desired output, see Ozone Output Adjustment section for Ozone Generator. 5

ENMET Corporation OZONE GENERATOR Ozone Output Adjustment: If the output is not the required level: Verify that the flow meter is set to 0.5 lpm. When the Ozone output is close to the desired concentration, adjustment should be made by a change in the position of the glass tube. This can be made by single turns of the knurled adjustment collar. Pushing the glass tube in decreases Ozone output and pulling the glass tube out increases the Ozone output. CAUTION: Small changes to the position (length of exposed lamp) will greatly affect the output of the generator. Loosen the retaining knurled collar on the ozone generator light (blue light). If the level of output is low, pull the glass tube out slightly. See section on verification of Ozone output. If it is too high, push the glass tube in slightly. See section on verification of Ozone output. Tighten the retaining ring on the generator light. Allow the generator to stabilize for at least 60 minutes and repeat the verification steps. When output level is correct apply Ozone to monitor. NOTE: A sample draw system is used with the ENMET Ozone monitors. The sample bag must be in place during monitor calibration. (See Figure 2: Ozone Generator out to sample bag, sample bag out to sample draw system.) Replacement Part Numbers ENMET replacement part numbers: Description Part Number Ozone Generator 04052-009 Tubing (per inch) 73073-000 Pump Kit, for Detector Tube 90000-111 Detector Tube, Ozone (box of 10) 90182-200 Gas Bag, (2 liter, 2 valve) 04052-014 6

OZONE GENERATOR ENMET Corporation WARRANTY ENMET warrants new instruments to be free from defects in workmanship and material under normal use for a period of one year from date of shipment from ENMET. The warranty covers both parts and labor excluding instrument calibration and expendable parts such as calibration gas, filters, batteries, etc... Equipment believed to be defective should be returned to ENMET within the warranty period (transportation prepaid) for inspection. If the evaluation by ENMET confirms that the product is defective, it will be repaired or replaced at no charge, within the stated limitations, and returned prepaid to any location in the United States by the most economical means, e.g. Surface UPS/RPS. If an expedient means of transportation is requested during the warranty period, the customer is responsible for the difference between the most economical means and the expedient mode. ENMET shall not be liable for any loss or damage caused by the improper use of the product. The purchaser indemnifies and saves harmless the company with respect to any loss or damages that may arise through the use by the purchaser or others of this equipment. This warranty is expressly given in lieu of all other warranties, either expressed or implied, including that of merchantability, and all other obligations or liabilities of ENMET which may arise in connection with this equipment. ENMET neither assumes nor authorizes any representative or other person to assume for it any obligation or liability other than that which is set forth herein. NOTE: When returning an instrument to the factory for service: Be sure to include paperwork. A purchase order, return address and telephone number will assist in the expedient repair and return of your unit. Include any specific instructions. For warranty service, include date of purchase If you require an estimate, please contact ENMET Corporation. There are Return for Repair Instructions and Form, on the last pages of this manual. This Form can be copied or used as needed. 7

ENMET Corporation OZONE GENERATOR Notes: 8

PO Box 979 680 Fairfield Court Ann Arbor, Michigan 48106-0979 734.761.1270 Fax 734.761.3220 Returning an Instrument for Repair ENMET instruments may be returned to the factory or any one of our Field Service Centers for regular repair service or calibration. The ENMET Repair Department and Field Service Centers also perform warranty service work. When returning an instrument to the factory or service center for service, paperwork must be included which contains the following information: A purchase order number or reference number. A contact name with return address, telephone and fax numbers Specific instructions regarding desired service or description of the problems being encountered. Date of original purchase and copy of packing slip or invoice for warranty consideration. If a price estimate is required, please note it accordingly and be sure to include a fax number. Providing the above information assists in the expedient repair and return of your unit. Failure to provide this information can result in processing delays. ENMET charges a one hour minimum billing for all approved repairs with additional time billed to the closest tenth of an hour. All instruments sent to ENMET are subject to a minimum $30 evaluation fee, even if returned unrepaired. Unclaimed instruments that ENMET has received without appropriate paperwork or attempts to advise repair costs that have been unanswered, after a period of 60 days, may be disposed of or returned unrepaired COD with the evaluation fee. Service centers may have different rates or terms. Be sure to contact them for this information. Repaired instruments are returned by UPS/FedEx Ground and are not insured unless otherwise specified. If expedited shipping methods or insurance is required, it must be stated in your paperwork. Note: Warranty of customer installed components. If a component is purchased and installed in the field, and fails within the warranty term, it can be returned to ENMET and will be replaced, free of charge, per ENMET s returned goods procedure. If the entire instrument is returned to ENMET Corporation with the defective item installed, the item will be replaced at no cost, but the instrument will be subject to labor charges at half of the standard rate.

Repair Return Form Mailing Address: ENMET Corporation PO Box 979 Ann Arbor, Michigan 48106 Phone Number: 734.761.1270 FAX Number: 734.761.3220 Shipping Address: ENMET Corporation Attn: Repair Department 680 Fairfield Court Ann Arbor, Michigan 48108 Your Mailing Address: Your Shipping Address: Contact Name: Your Phone: Your PO/Reference Number: Your FAX: Payment Terms: COD (check one) VISA / MasterCard Card number Expiration Return Shipping Method: UPS: Ground 3 Day Select Next Day Air ND Air Saver 2-Day Air Federal Express: Ground Express Saver P-1 Standard 2-Day Air FedEx Account number: Would you like ENMET to insure the return shipment? No Yes Insurance Amount: $