RS - SPM. Serial parallel translator module



Similar documents
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

DS1621 Digital Thermometer and Thermostat

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

DS1621 Digital Thermometer and Thermostat

with Electronic Assistant

SV 210 Signal Splitter and Incremental Converter for Sine-Cosine Encoders

NC-12 Modbus Application

RS-232 COMMUNICATIONS

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

Telephone- and leased line modem for industrial applications TD-36

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Install the DeviceNet Module using the following procedure:

Multifunction devices

Variable Preset Counter signo 723.1

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Application Note. Positioning with Dimetix distance sensor and SEW inverter FLS-C

TECHNICAL DATASHEET Incremental Encoder RI 80-E

Modular I/O System Analog and Digital Interface Modules

F2400 FOM II Series Fiber Optic Modem Technical Manual

X8 Option 2 - Technology

Datasheet of the Easy Servo Drive ES-D VDC, 8.2A Peak, Close-loop, No Tuning. Version

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

DC Electronic Loads 8500 series

GT Sensors Precision Gear Tooth and Encoder Sensors

PCS0100en Persy Control Services B.V. Netherlands

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Rack mounted telephone- and leased line modem for industrial applications

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Modbus Communications for PanelView Terminals

DS Wire Digital Thermometer and Thermostat

MILE Encoder for EC 90 flat

SyncLink GT2/GT4 Serial Adapter

ULC Technology: High-performance gate array package using multiple metal layer CMOS technology featuring sub-micron channel lengths (0.

ProCod. User Manual. Programming software for TWK - Encoders Series CRF and DAF CRF DE 08 / 10

DM74LS191 Synchronous 4-Bit Up/Down Counter with Mode Control

User manual LCD 240-2xx

Electrical connection

Using Xbee in Serial Communication

Operating Temperature: 0 o to 70 o C mm (0.89 inches) ... Incremental Front View

Manual Serial PCI Cards

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Short information Parameters are programmed via front-side membrane keypad

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

High-Speed, 5 V, 0.1 F CMOS RS-232 Driver/Receivers ADM202/ADM203

A RF18 Remote control receiver MODULE

Contents. Document information

User manual Compact Web PLC WP240 series IEC-line

Disturbance Recoder SPCR 8C27. Product Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

+5 V Powered RS-232/RS-422 Transceiver AD7306

Fairchild Solutions for 133MHz Buffered Memory Modules

FEATURES DESCRIPTION APPLICATIONS BLOCK DIAGRAM. PT2272 Remote Control Decoder

M1000 Process Alarm Monitor

155Mbps DFB SFP Optical Transceiver, 120km Reach

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

RS-232 Baud Rate Converter CE Model 232BRC Documentation Number 232BRC-3903 (pn5104-r003)

is then retained absolutely without interruption.

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

DS1307ZN. 64 x 8 Serial Real-Time Clock

Preset Counter signo 721

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

MicroMag3 3-Axis Magnetic Sensor Module

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

Indoor / Outdoor Antenna

LONGLINE 2km XFP Optical Transceiver

Bluetooth to Serial Adapter

DM Segment Decoder/Driver/Latch with Constant Current Source Outputs

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ACT4077 Driver for MACAIR A3818, A5690, A5232, A4905 & MIL-STD-1553

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

Duct Humidity Transmitter

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS (LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : DEC.01,1999 TOTAL PAGE : 7 APPROVED BY:

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

Combi B Alarm box. Mounting instructions

DS1821 Programmable Digital Thermostat and Thermometer

Description ELGO PNO 1 SSI/ Profibus - Converter

Application Note 83 Fundamentals of RS 232 Serial Communications

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Transcription:

ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: info@resatron.de RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject to change 1

General This translator module converts serial data from absolute encoders with serial Interface (SSI) into parallel data. The translator module has a micro controller system which continously reads serial data from the encoder and recalculates it into the required parallel format. lt is particularly user friendly and by means of a PC, it can easily be programmed with the necessary parameters, e. g.: - the number of steps per turn and the number of turns - the offset and the positional value for remote position setting - the parity flag - output code - the SSI format of the encoder used Features Programmable parallel data output in Gray, Binary or BCD code. Programmable number of steps per turn. Programmable number of turns. Programmable positional offset to suit the mechanical configuration. Programmable parity flag. Programmable remote position setting Programmable counting direction. Encoder alarm function with codes to indicate failure types. Entry and display of all parameters by means of a PC. universal parallel data output line driver for push pull, tristate, current source and current sink operation, protected against reversed polarity and against short circuiting to either earth or supply voltage. Synchronous serial interface differential output line drivers protected against reversed polarity and short circuiting to either earth or supply voltage. Renewal of encoder data in less than 400 µsec. Secure synchronous serial data transmission at 100 khz clock frequency. Non-volatile storage of all parameters in an EEPROM. DC/DC converter for the internal power supply. 2

Technical data Mechanical data Operating temperature range Storage temperature range Max. weight 0...+50 c -20...+85 c < 0,4 kg Dimensions (length x width x depth) See diagrams page 3, 4, 5 Connectors 1 x 37 pin male SUB-ID connector 1 x 15 pin female SUB-ID connector 1 x 9 pin female SUB-ID connector Housing synthetic Protection type IP 20 Electrical data Power supply, for RS SPM Us (Geber, RS SPM) Max. power consumption without load on Up and without encoder Line driver operating voltage range Up (driver) Encoder power supply Us (encoder, RS SPM) 11 32 VDC 3 W 4,5...32 VDC 10...32 VDC 10...32 VDC Max. current consumption without load 250 ma on Up and without encoder Max. cable length between RS SPM and encoder Electronic data Clock frequency for serial encoders Max. frequency of parallel data 400 m 100 khz 12,5 khz Note: The encoders can be used at significantly higher data frequencies than 2.5 khz. In this case, the increments between consecutive steps will no longen be one. Time delay for Store function Time delay for Enabl-e function Time delay for remote position setting function (with EEPROM) 30...70 PS 20...60 PS 700 ms 3

Line driver For the parallel interface Push-pull line driver, continuously short circuit and over-voltage protected, for tristate operation Min. driver voltage UP min Max. driver voltage Up max Max. driver source or sink current Id min at 20 C, at Up 4,5 V - 32 V Max. driver source or sink current Id min at 70 C, at Up 4,5 V - 32 V Logic high voltage UdHrnin bei 20 C I dh = 20 ma and 4,6 V < Up < 32 V Logic low voltage UdLmax at 20 C 4,5 V 32 V 50 ma 30 ma Up - 4,6 V 3,9 V For the serial interface to the absolute encoder Serial output switching (RS 485) protected against reversed polarity and short circuiting to either earth or supply voltage. 4

Control inputs For the parallel interface All control inputs have the same basic circuit and have either resistor R 1 or R 2 depending on the function of the input. The resistor is chosen so that when the control input is inactive, data output can occur, e.g. Store is fitted with R 1 and input Enable is fitted with R2. + UP switching threshoid for logic 1 hysteresis 5 V Ue > 2,6 V + 0,1 V 1,45 V + 0, 1 v 12 V Ue > 6,1 V + 0,1 V 1,55 V + 0, 1 V 24 V Ue > 12,2 V + 0,1 V 1,60 V + 0, 1 V switching delay 20 psec... 60 psec For the serial interface to the absolute encoder Serial input switching 6 N 137, protected against short circuiting to either earth or supply voltage. 5

Pin-outs 9pin female SUB-D-connector for PC Pin Signal Explanation 1,6 GND (encoder, driver, RS SPM) Earth reference point for RxD and TxD 2 TxD Transmit data: transmitting signal for the asynchronous serial interface 3 RxD Receive data: receiving signal for the asynchronous serial interface 4 Service This signal activates the RS SPM s service mode. It is activated when the connecting cable between RS SPM and the PC is inserted. When Service is activated, the RS SPM goes into parameter input mode. 5, 9 UB 5 V power supply 7, 8 N. C. not connected Screen The housing is electrically connected to the front plate. 15 pin female SUB-D-connector for serial interface encoders Pin Signal Explanation 1 GND (encoder, driver, RS SPM) Earth reference point for RxID and TxD 2 Data + Positive serial data input signal from the encoder. To be connected to Data + output from the encoder. 3 Clock + Positive clock output signal from a RS 485 driver. To be connected to Clock + from the encoder. 8 +Us (encoder, RS SPM) Encoder power supply. Please read label on the encoder prior to use. 10 Data - Inverted serial data input signal from the encoder. To be connected to Data - from the encoder. 11 Clock - Inverted clock output signal from a RS 485 driver. To be connected to Clock - from the encoder. 4, 5,6, 7, 9, N. C. not connected 12,13, 14 15 Note: ReSatron absolute serial encoders AG have a cw/ccw input to select the counting direction. This input must not be used with the RS SPM. The RS SPM can, however, be programmed to give the required counting direction. 6

Pin-out 37 pin male SUB-D-connector for the SPA 2 parallel interface Pin Signal Explanation 1,20 GND (encoder, driver, RS SPM) Earth connection for RS SPM, encoder and line drivers. 13 +Us (encoder, SPA 2) Power supply for the encoder and RS SPM. Please read label on encoder prior to use. 31 Up (driver) Positive supply voltage for line drivers. Isolated from Us (encoder, SPA 2) > 4,5 V < 32 V. 12 Enable This inputs activates the RS SPM line drivers. At High the outputs are inactive. When unconnected, this input is at logic 0. 11 Parity Output for the parity bit. 30 Store This input stores output data at Low. When unconnected it is at High. 29 Remote position setting When this input is at logic 1, the position of the encoder is reset to the programmed value. This input must be held at logic 1 for at least 0.6 sec. When unconnected, this input is at logic 0. 32 Error Normally, this output remains at logic 1. lf a fault is detected, it switches to logic 0. The fault types are coded as follows 0 = RS SPM in Service mode 1 = power down 2 = encoder interrogation fault 4 = remote position setting 19 N. C. not connected 7

37pol. SUB-D-connector for the RS SPM, parallel interface Pin Signal Explanation Binär Gray BCD 2 2 0 G 0 2 0 v. 10 0 21 2 1 G 1 2 1 v. 10 0 3 2 2 G 2 2 2 v. 10 0 22 2 3 G 3 2 3 v. 10 0 4 2 4 G 4 2 0 v. 10 1 23 2 5 G 5 2 1 v. 10 1 5 2 6 G 6 2 2 v. 10 1 24 2 7 G 7 2 3 v. 10 1 6 2 8 G 8 2 0 v. 10 2 25 2 9 G 9 2 1 v. 10 2 7 2 10 G 10 2 2 v. 10 2 26 2 11 G 11 2 3 v. 10 2 Data outputs 8 2 12 G 12 2 0 v. 10 3 27 2 13 G 13 2 1 v. 10 3 9 2 14 G 14 2 2 v. 10 3 28 2 15 G 15 2 3 v. 10 3 14 2 16 G 16 2 0 v. 10 4 33 2 17 G 17 2 1 v. 10 4 15 2 18 G 18 2 2 v. 10 4 34 2 19 G 19 2 3 v. 10 4 16 2 20 G 20 2 0 v. 10 5 35 2 21 G 21 2 1 v. 10 5 17 2 22 G 22 2 2 v. 10 5 36 2 23 G 23 2 3 v. 10 5 37 2 24 G 24 2 0 v. 10 6 10, 18 N. C. Not connected Screen The connector housing acts as a screen and is electrically connected to the front plate. 8

Pin-out 64pin VG male connector for the RS SPM, parallel data output and the encoder serial data interface Pin Signale Explanation la, lc, 2c, GND (encoder, RS SPM) Earth connection for RS SPM and encoder 25a, 25c 13c, 32c, +Us (encoder, RS SPM) Power supply for the encoder and RS SPM. 32a Please read label on encoder prior to use. 31a Up (driver) Positive supply voltage for line drivers. Isolated from Us (encoder, RS SPM), i.e. Up=open. 10c Enable This input activates the RS SPM line drivers. At High the outputs are inactive. When unconnected, this input is at logic 0. 19a UB lf the SPA 2 is used with a 5 V power supply voltage connected through UB, +Us (encoder, SPA 2) must not be connected The power supply from the encoder cannot then be obtained from the 15 pin SUB-D connector. 19c N. C. not connected 22a Error Normally, this output remains at logic 1. lf a fault is detected, it switches to logic 0. The fault types are coded as follows 0 = RS SPM in service mode 1 = power down 2 = encoder interrogation fault 4 = remote position setting 24a Remote position setting When this input is at logic 1, the position of the encoder is reset to the preprogrammed value. This input must be held at logic 1 for at least 0.6 sec. When unconnected, this input is at logic 0. 24c Store This input stores output data at Low. When unconnected, it is at High 26a Data - Inverted serial data input signal from the encoder. To be connected to Data - from the encoder. 26c Data + Positive serial data input signal from the encoder. To be connected to Data + from the encoder. 27a Clock - Inverted clock output signal from a RS 485 driver. To be connected to clock - from the encoder. 27c Clock + Positive clock output signal from a RS 485 driver. To be connected to Clock + from the encoder. 28c Parity Output for the parity bit. 9

RS SPM Pin-out 64pol. VG male connector for the RS SPM, parallel data output and the encoder serial data interface Pin Signal Explanation Binär Gray BCD 2a 2 24 G 24 2 0 v. 10 6 3c 2 0 G 0 2 0 v. 10 0 3a 2 1 G 1 2 1 v. 10 0 4c 2 2 G 2 2 2 v. 10 0 4a 2 3 G 3 2 3 v. 10 0 5c 2 4 G 4 2 0 v. 10 1 5a 2 5 G 5 2 1 v. 10 1 6c 2 6 G 6 2 2 v. 10 1 6a 2 7 G 7 2 3 v. 10 1 7c 2 8 G 8 2 0 v. 10 2 7a 2 9 G 9 2 1 v. 10 2 8c 2 10 G 10 2 2 v. 10 2 Data outputs 8a 2 11 G 11 2 3 v. 10 2 9c 2 12 G 12 2 0 v. 10 3 9a 2 13 G 13 2 1 v. 10 3 14c 2 14 G 14 2 2 v. 10 3 14a 2 15 G 15 2 3 v. 10 3 15c 2 16 G 16 2 0 v. 10 4 15a 2 17 G 17 2 1 v. 10 4 16c 2 18 G 18 2 2 v. 10 4 16a 2 19 G 19 2 3 v. 10 4 17c 2 20 G 20 2 0 v. 10 5 17a 2 21 G 21 2 1 v. 10 5 18c 2 22 G 22 2 2 v. 10 5 18a 2 23 G 23 2 3 v. 10 5 21c 2 25 G 25 2 1 v. 10 6 21 a 2 26 G 26 2 2 v. 10 6 22c 2 27 G 27 2 3 v. 10 6 23c 2 28 G 28 2 0 v. 10 7 23a 2 29 G 29 2 1 v. 10 7 10a, 11a, 11c, 12a,12c, N. C. not connected 13a, 20a, 20c, 28a,29a, 29c, 30a, 30c,31c 10

Connection details Using the 37 pin SUB D connector listed in the accessories the following connections should be made: Parallel data lines, supply voltage for the RS SPM and the absolute encoder, power supply for the data output drivers, error signal output, parity signal output, store input and the telesetting input. The cable screen should be connected to the connector housing. Accessories Programming software 37 pin female SUB-D-connector with connectotr pocket 15 pin male SUB-D-connector with connector pocket 11

12