Network configuration for the IBM PureFlex System



Similar documents
VLAN 802.1Q. 1. VLAN Overview. 1. VLAN Overview. 2. VLAN Trunk. 3. Why use VLANs? 4. LAN to LAN communication. 5. Management port

Using Virtual Switches in PowerVM to Drive Maximum Value of 10 Gb Ethernet

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

An Oracle White Paper October How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios

What is VLAN Routing?

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study

Installation of the On Site Server (OSS)

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W

Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version

How to Create VLANs Within a Virtual Switch in VMware ESXi

LANs and VLANs A Simplified Tutorial

What s New in VMware vsphere 5.5 Networking

Brocade Solution for EMC VSPEX Server Virtualization

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

CHAPTER 10 LAN REDUNDANCY. Scaling Networks

A Principled Technologies white paper commissioned by Dell Inc.

Switching in an Enterprise Network

Abstract. MEP; Reviewed: GAK 10/17/2005. Solution & Interoperability Test Lab Application Notes 2005 Avaya Inc. All Rights Reserved.

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Application Note Gigabit Ethernet Port Modes

Switch Quick Configuration CLI Guide for

vsphere Networking ESXi 5.0 vcenter Server 5.0 EN

Alexander Paul IBM Certified Advanced Technical Expert (C.A.T.E.) for Power Systems Certified Cisco Systems Instructor CCSI #32044

Overview of Routing between Virtual LANs

Layer 3 Network + Dedicated Internet Connectivity

If you already have your SAN infrastructure in place, you can skip this section.

UTM10 in multi-ssid, multi-vlan network with WMS5316. Network diagram

ADVANCED NETWORK CONFIGURATION GUIDE

How to Create a Virtual Switch in VMware ESXi

Network Virtualization and Data Center Networks Data Center Virtualization - Basics. Qin Yin Fall Semester 2013

Elisa Carrier Services. Elisa Operator Broadband Services. Technologies, distribution centres and delivery interfaces

IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide

20 GE + 4 GE Combo SFP G Slots L3 Managed Stackable Switch

VMware Virtual Networking Concepts I N F O R M A T I O N G U I D E

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

Networking Solutions for Storage

Introduction to MPIO, MCS, Trunking, and LACP

N5 NETWORKING BEST PRACTICES

Direct Attached Storage

VMware ESX Server Q VLAN Solutions W H I T E P A P E R

Systemverwaltung 2009 AIX / LPAR

hp ProLiant network adapter teaming

- EtherChannel - Port Aggregation

SSVP SIP School VoIP Professional Certification

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example

Virtual Networking with z/vm Guest LAN and Virtual Switch

4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0

Virtual PortChannel Quick Configuration Guide

VLANs. Application Note

Oracle Big Data Appliance: Datacenter Network Integration

Portable BACnet /IP to MS/TP Router

How To Set Up A Virtual Network On Vsphere (Vsphere) On A 2Nd Generation Vmkernel (Vklan) On An Ipv5 Vklan (Vmklan)

Monitoring and Analyzing Switch Operation

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

HARTING Ha-VIS Management Software

BLADE PVST+ Spanning Tree and Interoperability with Cisco

Ethernet Link SGI-2424

Chapter 3. Enterprise Campus Network Design

Multi-Chassis Trunking for Resilient and High-Performance Network Architectures

EXINDA NETWORKS. Deployment Topologies

ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af

Abstract. Avaya Solution & Interoperability Test Lab

Aruba Mobility Access Switch and Arista 7050S INTEROPERABILITY TEST RESULTS:

Switch Web GUI Quick Configuration Guide for

Course. Contact us at: Information 1/8. Introducing Cisco Data Center Networking No. Days: 4. Course Code

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Network Troubleshooting & Configuration in vsphere VMware Inc. All rights reserved

Ethernet Link SGI-4844F

Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot

EGS7228P. Business Class EGS7228P. 24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW

Virtual LANs. or Raj Jain

Monitoring Traffic. Traffic Monitoring. This chapter includes the following sections:

Deployment Guide. How to prepare your environment for an OnApp Cloud deployment.

GS700TS FS700TS Access to the Internet on multiple VLANS using Multi- Homing

A Guide to Simple IP Camera Deployment Using ZyXEL Bandwidth Solutions

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

Balcan-IX Services Description

IP SAN Best Practices

Exhibit n.2: The layers of a hierarchical network

Adding Traffic Sources to a Monitoring Session, page 7 Activating a Traffic Monitoring Session, page 8 Deleting a Traffic Monitoring Session, page 9

Nutanix Tech Note. VMware vsphere Networking on Nutanix

IP SAN BEST PRACTICES

6/8/2011. Document ID: Contents. Introduction. Prerequisites. Requirements. Components Used. Conventions. Introduction

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

SN A. Reference Guide Efficient Data Center Virtualization with QLogic 10GbE Solutions from HP

Cisco EtherSwitch Network Modules

vsphere Networking vsphere 5.5 ESXi 5.5 vcenter Server 5.5 EN

TP-LINK L2 Managed Switch

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

SSVVP SIP School VVoIP Professional Certification

Fibre Channel over Ethernet in the Data Center: An Introduction

PassTest. Bessere Qualität, bessere Dienstleistungen!

Walmart s Data Center. Amadeus Data Center. Google s Data Center. Data Center Evolution 1.0. Data Center Evolution 2.0

vsphere Networking vsphere 6.0 ESXi 6.0 vcenter Server 6.0 EN

LiveAction Application Note

Cisco - Catalyst 2950 Series Switches Quality of Service (QoS) FAQ

Transcription:

Network configuration for the IBM PureFlex System Note: The initial configuration of your IBM PureFlex System will be performed by IBM services that are included with your purchase. To ensure their success, it is important that you not change the default shipped configuration until these services are complete. 1 Introduction The IBM PureFlex System comes with three networks, each of which is isolated from the others by Virtual LAN (VLAN) assignment within the Ethernet switches. Your view to each network is through one or more "uplink" ports, which are untagged. (That is, the frames coming out of those ports do not have any IEEE 802.1q VLAN tags, and incoming untagged frames are automatically sent to the right network.) The networks can be differentiated by the color of the cabling used: Green, Purple, and Gold. Green Network The green network is for your data and it is assigned to VLAN 4092. There are no IP addresses assigned to this network in IBM Manufacturing, so you can assign them to meet your needs. Purple Network The purple network is assigned to VLAN 4091. All entities on the purple network are assigned IPv4 addresses within the 10.91.0.0/16 network (that is, 10.91.*.* with netmask 255.255.0.0). This is the network where you access the IBM Flex System Manager node on its external Ethernet (eth1) interface. It also enables you to directly access the following: The Virtual I/O Server (VIOS) on Power Systems compute nodes The ESXi hypervisor on X-Architecture compute nodes In addition, any guest operating systems that you want to manage using the IBM Flex System Manager need to have an IP address on this network. Gold Network The gold internal device management network is assigned to VLAN 4093 on singlechassis systems without any top-of-rack switches, and is entirely isolated on the top-of-rack switches, if present. This network contains the following: The IBM Flex System Manager node's internal Ethernet (eth0) interface Chassis Management Modules (CMMs) The management interfaces for any Ethernet or SAN switches T flexible service processors of Power Systems compute nodes and integrated management modules (IMMs) of X-Architecture compute nodes The IBM Storwize V7000 management interfaces 1

Each of these endpoints is assigned a fixed IPv4 address on the 192.168.93.0/24 network (that is, 192.168.93.* addresses with netmask 255.255.255.0), and an IPv6 Unique Local Address (ULA) that is guaranteed not to conflict with any address on the customer's network. The IBM Flex System Manager node manages all of these endpoints using the IPv6 addresses, so you can choose to reassign the IPv4 addresses as desired to fit into your network. The details of what IP addresses are assigned to which endpoints are described in Default IP addressing on page 5. As noted above, the IBM Flex System Manager is able to communicate on both the purple and gold networks. 2 Compute node connections Each compute node has connections to the internal ports of its chassis' 10 Gb switches. Those ports are configured with Port VLAN ID (PVID) 4091 (purple), with access to VLAN 4092 (green) through explicit VLAN tags. Every Power Systems compute node ships with a virtual server with the Virtual I/O Server (VIOS) software installed on it (or two VIOS virtual servers for a 4S compute node). Each VIOS virtual server is configured to have its IP address on the purple network, and a shared Ethernet adapter (SEA) that provides access to both the green and purple networks for "guest" virtual servers. The single template virtual server has two virtual Ethernet adapters: one with untagged access to the purple network (in virtual slot 2), and another with untagged access to the green network (in virtual slot 3). Each Ethernet connection from a compute node is limited to a single port: the appropriate internal port A compute node slot. The internal port B ports are only enabled by adding more license keys to the inchassis 10 Gb Ethernet switches. Even if those ports are enabled using license keys, they are not configured by IBM Manufacturing. 3 Uplinks Every PureFlex System has at least 2 10Gbps short-range optical Ethernet interfaces associated with the green network, at least 1 1Gbps BASE-T (RJ45, CAT-5/CAT-6 cable) interface for the purple network, and 1 BASE-T interface for the gold network. All switches have the Per-Vlan Rapid Spanning Tree (PVRST) protocol enabled, with each virtual LAN (VLAN) assigned to a separate Spanning Tree Group (STG). The in-chassis 10 Gb Ethernet switches ship with bridge priority 61440, and the top-of-rack switches with bridge priority 32768. This should prevent any routing loops, regardless of how many cables you plug into each uplink group. If you have top-of-rack switches, the green and purple uplink ports are on the G8264 switches, and all of the empty ports on the G8052 switches serve as uplink ports for the yellow network. In these 2

configurations, there is no need for you to directly access the 10 Gb Ethernet switches that are in the chassis. If there are no top-of-rack switches, all of the uplink ports are on the 10 Gb Ethernet switches that are in the chassis. Within a given switch, all green uplink ports have Link Aggregation Control Protocol (LACP) enabled with a common key. If you connect with an LACP-aware partner, those ports form a common aggregate (also called a trunk or portchannel), that lets traffic run in parallel across all of the ports. Likewise, if you use a top-of-rack G8264 switch, the purple uplink ports are configured to share an LACP key. 3.1 Customer uplink map in each configuration The following table describes the switch configuration for each uplink group. Unless stated otherwise, all of the uplink ports have the appropriate transceivers. If there's a links statement, that means that only those ports have transceivers plugged, but more transceivers can be added to empty ports in that group to offer more bandwidth. Green - 10 Gb Ethernet switch 1-4 o PureFlex Express links in 1-2 o PureFlex Standard links in 1-2 or 1-4 (optional) Purple - 10 Gb Ethernet switch 5 Yellow - 10 Gb Ethernet switch 6 3.2 Single chassis configurations The IBM PureFlex System comes with two CMMs. The CMMs are configured in an IP failover environment. The IBM Storwize V7000 is configured with three IP addresses consisting of service IP addresses for each of the two controller nodes and a cluster IP address which both nodes can respond to for management purposes. 3

4 Cabling diagram for a single chassis configuration The following diagram shows the cabling and VLAN tagging that will be done in the Ethernet IO Module in bay 1 of the chassis. The E# values are the port numbers on the switch. 4

5 Default IP addressing Following are the default IP addresses that are assigned to your IBM PureFlex System for single and multiple chassis. The color coding matches the VLANs listed above: 5

Note about IPv6 Addressing: An IPv6 address is represented by 8 groups of 16-bit hexadecimal values separated by colons (:). The default addresses in the table above only reflect the first 4 groups. The last four groups are calculated using the MAC address of the adapter in question or can be the last four groups in the link-local address (LLA). 6