Introducing the AccuVein AV300 The first portable, non-contact vein illumination device It weighs only 10 ounces, fits in the palm of your hand and uses an easy point and click technology. An Essential Tool The AccuVein AV300 is as essential for venipuncture as a stethoscope is for examining the heart and lungs. Once put into use, the benefits of the AccuVein AV300 will become so evident it will become part of the standard of care for all blood draws and IV starts. Designed for the Medical Professional The AccuVein AV300 has been designed with medical professionals in mind, as even in the hands of a skillful professional, starting an IV or drawing blood can be a challenge. Imagine how much more ef fective nurses, phlebotomists, EMTs and any caregiver performing venipuncture could be if a patient s veins could be located beneath the skin.
Product Data Sheet AccuVein AV300 AV300 Features Easy to learn and use No pre-use calibration or adjustments are necessary-it can be used immediately. Small size The AV300 fits in your hand and weighs only 10 ounces. Hands-free option Either hand-hold the AV300 or set it in a hands-free accessory. No patient contact Because the AV300 has been designed to be non-contact, it may not have to be sterilized after every use. Establishing IV access in difficult patients can take up to 10 minutes * 2.7 million venipunctures are attempted every day in the U.S. * Venipuncture is the most common invasive medical procedure * Rechargeable battery The AV300 doesn¹t need to be plugged into an electrical outlet. Real World Ruggedness Designed to take the wear and tear of hospital and field applications. Movement tolerant Because the AV300 shows the veins in real time, when operated properly, the device can accommodate patient movement. For more information please visit our website at www.accuvein.com or contact AccuVein sales by calling 888.909.8888 toll-free or 816.997.9400 How It Works Hemoglobin in the blood absorbs infrared light. When the AccuVein AV300 is held about seven inches above the skin, veins appear noticeably different than the surrounding tissue. The vasculature shows up clearly on the skin s surface, aiding in vein location for blood draws and IV starts. Specifications Weight Size Continuous run time on full charge (vein light on) Charge Time Viewing procedures per charge Battery 10 oz. 1.9 x2.4 x7.8 Typically 2 hours Typically 2 hours 360 AccuVein BA300 Lithium Ion 3.7 V 2,400 mah VISIBLE AND INVISIBLE LASER RADIATION DO NOT STARE INTO BEAM. CLASS 2 LASER PRODUCT. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. Wavelength 642 nm/785 nm, Peak Power 40 mw/25 mw, Pulse Energy 2.57µJ /1.58µJ, Pulse Length 900 ns. IEC/EN 60825-1 (2001/07) Options and Accessories In addition to the AV300 device, the following components are included in the base system: Battery (Already installed) Charging cradle (shown above), universal power supply, and multinational adapters USB cable To simplify transport for EMT and home healthcare workers we offer various carrying cases. With AccuVein hands-free solutions, the device can quickly switch from hand-held to hands-free allowing both hands to be free to perform a procedure. * Sources available upon request 2009, AccuVein, LLC. AccuVein is a registered trademark of AccuVein, LLC. 40 Goose Hill Road Cold Spring Harbor, NY 11724 T816.997.9400 F631.270.3960 www.accuvein.com FS-0509-REVE
VEFI200 Introducing the AccuVein HF350 A secure, portable, hands-free solution for the AV300 With the sound of a click you can secure the AV300 and take it where ever you go. Designed for the Medical Professional An Essential Tool The AccuVein HF350 is an essential accessory for the AV 300 if you are a medical professional who is always on the go. This snap in solution can be used with both the HF 300 Powered HandsFree Device or the HF320 Unpowered HandsFree Device. - The AccuVein HF350 has been designed with medical professionals on the go in mind. Since the hands of a professional are key to starting an and IV or drawing blood we have made the AV300 easier to use than ever before. Imagine how much more quickly nurses, phlebotomists, and any caregiver performingvenipuncture could be if a the AV300 can be moved from bed to bed by simply sliding it across the floor.
Ref. Certif. No. US/2209/ITS-A1/M2 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME CB TEST CERTIFICATE SYSTEM CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CERTIFICAT D'ESSAI OC Product Produit Name and address of the Applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Rating and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) Vein Viewer AccuVein LLC 40 Goose Hill Road Cold Spring Harbor, NY 11724 Benchmark Electronics Inc., Minnesota Div. 3535 Technology Dr. Rochester MN, 55901 Benchmark Electronics Inc., Minnesota Div. 3535 Technology Dr. Rochester MN, 55901 Internally powered: 3.7VDC, 2400mAh, 9Wh Lithium-Ion Battery External Power supply: Input: 100-240V~, 50-60Hz, 0.4A Output: +5VDC, 2.0A AccuVein Type of manufacturer's Testing Laboratories used Type de programme de laboratoire d'essais constructeur Model / Type Ref. Ref. De type Additional information (if neccessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqué sur la 2ème page) A sample of Product was tested and found to be in conformity with IEC Un échantillon de ce produit a été essayé et été considéré conforme à la CEI National differences / Comments Les différences nationales / Commentaires As show in the Test Report Ref. No. which forms part of this certificate Comme indiqué dans le Rapport d'essais numéro de référence qui constitue partie de ce certificat AV300 A1: Additional factory location added. M2: Revised pcb part numbers. M1: Report was corrected to reflect the non use of an appliance coupler. Original certificate issued: January 11, 2010. 60601-1(ed.2);am1;am2 AU, BR, CA, DK, IL, US 3170813MIN-011 This CB Test Certificate is issued by the National Certification Body: Ce Certificat d'essai OC est établi par l'organisme National de Certification Intertek Testing Services, N.A. 165 Main Street, Cortland, NY 13045, USA Date: 2010-07-21 Signature: John Quigley
Ref. Certif. No. US/2209/ITS-A1/M2 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEM CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC Additional factory Benchmark Electronics, Inc. 4155 Theurer Blvd. Winona, MN 55987 This CB Test Certificate is issued by the National Certification Body: Ce Certificat d'essai OC est établi par l'organisme National de Certification Intertek Testing Services, N.A. 165 Main Street, Cortland, NY 13045, USA Date: 2010-07-21 Signature: John Quigley