Certificate of Analysis



Similar documents
HS 1003 Part 2 HS 1003 Heavy Metals Test

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

EL724. Biodegradable Resin Products [EL /2/ ]

IB Chemistry. DP Chemistry Review

4.2 Bias, Standards and Standardization

Heavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy

RoHS Test Methods. Presented by: Bruce Peterson

OLIVÉR BÁNHIDI 1. Introduction

Solutions and Dilutions

The Empirical Formula of a Compound

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

DMA-80 Direct Mercury Analyzer

DMA-1 Direct Mercury Analyzer

This example of a completed sampling plan worksheet has been included to illustrate the information

Elemental Analyses by ICP-AES

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

MILESTONE H E L P I N G C H E M I S T S

ANALYTICAL REPORT LABORATORY DETAILS. Telephone Facsimile . SGS Reference Report Number Date Reported Date Received

HMHF DIRECT DRIVE BELT DRIVE. Manufactured by UDY Corporation. Cyclone Models Available:

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

OXIDATION-REDUCTION TITRATIONS-Permanganometry

PRETREATMENT TECHNICAL DATA SHEET WATER EMULSIFIABLE RUST PREVENTATIVE PRODUCT DESCRIPTION

Paper Chromatography: Separation and Identification of Five Metal Cations

Hot water extractable acidity or alkalinity of paper (Reaffirmation of T 428 om-08) (No changes from Draft 1)

Physical Changes and Chemical Reactions

Physical & Chemical Properties. Properties

Test Report No: (15) Date: 05-Apr-12 Page 1 of 5

# 12 Condensation Polymerization: Preparation of Two Types of Polyesters

USE OF REFERENCE MATERIALS IN THE LABORATORY

Mechanical Energy. Mechanical Energy is energy due to position or motion.

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Hands-On Labs SM-1 Lab Manual

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

EXPERIMENT 12: Empirical Formula of a Compound

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

DURAPOSIT TM SMT 810 Electroless Nickel

NUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility

CH3 Stoichiometry. The violent chemical reaction of bromine and phosphorus. P.76

1. Qualitative Analysis of Chromium, Iron, and Copper

Additional Lecture: TITRATION BASICS

Mercury Determination in House Dust, NIST SRM-2584, USEPA Method 7473, Using the Teledyne Leeman Labs Hydra II C Combustion CVAAS

Recovery of Elemental Copper from Copper (II) Nitrate

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

CRITERIA DOCUMENTATION VERIFICATION PRINTED PAPER (Commission Decision 2012/481/EU)

Target Mole Lab. Mole Relationships and the Balanced Equation. For each student group Hydrochloric acid solution, HCl, 3 M, 30 ml

2 MATTER. 2.1 Physical and Chemical Properties and Changes

Heterogeneous Homogenous. Mixtures; Solutions. Phases of matter: Solid. Phases of Matter: Liquid. Phases of Matter: Gas. Solid, Liquid, Gas

Determination of a Chemical Formula

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Sensitivity to both h- and i-line makes AZ 9200 photoresist capable for both broadband and i-line steppers.

Grammage of paper and paperboard (weight per unit area) (Revision of T 410 om-08) (underscores and strikeouts indicate changes from Draft 1)

Separation of Amino Acids by Paper Chromatography

Calculation of Molar Masses. Molar Mass. Solutions. Solutions

Cleaning Validation by TOC Analyzer

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

NANYANG TECHNOLOGICAL UNIVERSITY. School of Civil and Environmental Engineering. CV2701: Laboratory 2A. Laboratory Manual. For

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

Name Class Date. What is ionic bonding? What happens to atoms that gain or lose electrons? What kinds of solids are formed from ionic bonds?

Foam Injection Molding:

Chapter Test B. Chapter: Measurements and Calculations

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Identifying Your Hazardous Waste

Warm-Up 9/9. 1. Define the term matter. 2. Name something in this room that is not matter.

3.2 The Department of Environmental Health and Safety is responsible for;

Experiment 7: Titration of an Antacid

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Chapter Test A. Elements, Compounds, and Mixtures MULTIPLE CHOICE. chemically combined? MIXs2 a. element b. compound c. mixture d.

Secondary Lead Smelting

Chapter 3 Student Reading

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Work hard. Be nice. Name: Period: Date: UNIT 1: Introduction to Matter Lesson 4: A Fine Line Between Compounds and Mixtures

Molar Mass of Butane

MOLES AND MOLE CALCULATIONS

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

Materials for the production of primary aluminium

Chapter 8 - Chemical Equations and Reactions

ATI Wah Chang Laboratory and Technical Services: Analytical Laboratory

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Performance and advantages of qnmr measurements

EXPERIMENT 9 (Organic Chemistry II) Pahlavan - Cherif Synthesis of Aspirin - Esterification

CHEMICAL REACTIONS OF COPPER AND PERCENT YIELD KEY

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

CHM220 Addition lab. Experiment: Reactions of alkanes, alkenes, and cycloalkenes*

Name: Unit 2- Elements, Compounds and Mixtures and Physical/Chemical Properties and Changes. Elements, Compounds and Mixtures

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Santa Monica College Chemistry 11

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Laboratory Hazardous Waste Disposal Guidelines

FMA-80 Fluorescence Mercury Analyzer

Proficiency testing schemes on determination of radioactivity in food and environmental samples organized by the NAEA, Poland

The Properties of Water (Instruction Sheet)

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory.

Chemistry: Chemical Equations

Organic Chemistry Calculations

Physical Properties of a Pure Substance, Water

M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE

Transcription:

The Japan Society for Analytical Chemistry Certificate of Analysis Certified Reference Material JSAC 0602-3 Plastics (tip form) for Chemical Analysis of Hazardous Metals This certified reference material (CRM) consists of polyester resin tips whose trace concentrations of lead (Pb), cadmium (Cd), chromium (Cr) and mercury (Hg) were certified. Certified values are shown in Table 1 together with their uncertainties. This CRM is intended primarily for use in evaluating methods of analyses used in the determination of trace metallic elements in polymer moldings or other products made of plastics by comparing the certified values with the analytical results of the CRM obtained from the analysis executed in parallel with the sample to be analyzed. This CRM is crushed polyester resin tips, 0.5 ~ 1 mm in tip size. 50 g of CRM is filled in an amber glass bottle and the bottle is packed in a carton box. Table 1 Certified values Elements Certified value uncertainty 1) Interlaboratory Number of Main methods g/g standard deviation 2) data applied of analyses 3) (SD) g/g (N) Pb 112.0 ± 1.4 2.9 19 (1),(2),(3),(4),(5),(6),(8) Cd 50.4 ± 0.5 1.1 18 (1), (2), (3), (4), (6), (8) Cr 112.6 ± 1.8 3.8 20 (1), (2), (3), (4), (6),(8) Hg 12.1 ± 0.6 1.1 17 (1),(6),(7),(8) Note 1) Uncertainties were 95% confident limit of each medians (U95%). They were calculated with the following equation. U95% = (t SD) N t : in the Student t distribution table 2) In case of evaluation of analytical results by the user of the CRM, it is recommended to consider not only uncertainties but also SDs. 3) For method No., refer Procedure for certification, 1 in next page. Instructions for use 1. Be careful of contamination from environment in handling the CRM. 2. Plug the bottle immediately after putting out the contents except when the bottle had been 1

made empty. 3. The CRM once taken out from the bottle should not be return to the bottle. 4. Notice related to the safety data sheet for chemical product: this CRM contains slight amount of compounds of Hg that is indicated legally as poisonous/deleterious materials. Be careful at handling. Storage of CRM and expiration of certification 1. The CRM should be stored in the dark and cool place. It is a safe way to keep the CRM in a box or in a plastic film bag in order to avoid the CRM from environmental contamination. 2. There will be no change on certified values if the CRM stored in dark and cool place. It is planned the periodical stability test for this CRM. It will be reported on JSAC journal or the homepage after test result will be obtained. Preparation of CRM and confirmation of its homogeneity 1. Weighed necessary amount of organic complexes, Cr( )-acetyl acetonate, Cd-cyclohexane butyrate, tetraphenyl-pb and Hg-cyclohexane butyrate were dissolved in toluene. The toluene solution was poured to the polyester oligomer (liquid) and mixed well. After addition of curing catalyst, the mixed solution was poured to molds in order to make polyester plates, approximately 50 cm square and 3 mm thick. Hardened plates were broken in small pieces by hand, and then crushed with a cutter mill (steel body, rotor edge and stator edge are made of high speed steel). Polyester fragments discharged from exit screen of the mill were sieved to get fragments, passing 1 mm screen and stopped on 0.5 mm screen. Obtained fragments were put in a polypropylene bottle, 17 L of capacity. Then the bottle was rotated using a roll mill to homogenize the contents. 2. Homogenized polyester tips were packed 50 g each in 243 amber glass bottles (cap:110 ml). Small amount of tips were sampled in 2 times from 10 bottles, and applied acid decomposition. Concentrations of Cd, Pb and Cr in the solutions were measured by ICP atomic emission spectrometric analysis. The standard deviations between bottles were so small that they cannot be calculated. From the results it is proved that the polyester tips are homogeneous well. Procedure for certification of the concentration The certified values of metals in this CRM were obtained by statistical calculation of the results of an interlaboratory comparison study performed with 20 laboratories. In the study, numbers of elements to be measured were four as shown in Table 1, and analytical methods were limited as shown in Manual for analysis sent to laboratories from JSAC. 1. Briefings of analytical methods in the manual. (1) Closed system acid decomposition inductively coupled plasma mass spectrometry The sample was digested with suitable reagents such as nitric acid using microwave digester 2

and the digested solution was sprayed into inductively coupled plasma. Intensities of ion currents of Cd, Cr, Pb were measured at their m/z. Cd, Cr and Pb are quantified from their intensity ratios of ion current to internal standard. (2) Closed system acid decomposition inductively coupled plasma atomic emission spectrometry The sample was digested with suitable mixed acids including nitric acid using microwave digester and the digested solution was sprayed into inductively coupled plasma. Cd, Cr and Pb are quantified from their intensities of emission spectra. (3) Open system acid decomposition inductively coupled plasma atomic emission spectrometry The sample was digested with suitable mixed acids including nitric acid, and the digested solution was sprayed into inductively coupled plasma. Cd, Cr and Pb were quantified from their intensities of emission spectra. (4) Sulfuric acid carbonization-ashing-fusion high frequency plasma atomic emission spectrometry The sample was carbonized by sulfuric acid at first, ashed at low temperature, and then fused. Metallic constituents in fused material were extracted by acid. Pb, Cd and Cr in the extract were analyzed by inductively coupled plasma atomic emission spectrometry (5) Closed system acid decomposition reduction airlation atomic absorption spectrometry The sample was digested with suitable reagent including nitric acid using microwave digester. To the digested solution, SnCl2 solution was added to reduce mercury compounds to elemental Hg. The product solution was made for airlation to evaporate mercury vapor. The vapor was introduced to the cold vapor atomic absorption spectrometer to quantify Hg. (6) Reflux cooling acid decomposition reduction airlation atomic absorption spectrometry The sample was decomposed with nitric acid, sulfuric acid and potassium permanganate. After decomposition of residual nitrous acid by addition of urea solution, potassium permanganate in excess was reduced by addition of hydroxylammonium chloride solution. Hg compound in the solution was reduced by addition of SnCl2 solution. Generated Hg vapor by airlation into this solution was introduced to cold vapor atomic absorption spectrometer. (7) Thermal vaporization-gold amalgam atomic absorption spectrometry The sample was heated to produce mercury vapor from mercury compounds. The vapor is introduced to the surface of golden plate. After mercury in vapor was caught as gold amalgam, the amalgam was heated to release concentrated mercury vapor. Mercury vapor was introduced to atomic absorption spectrometer. (8) Other methods 2. Operation of interlaboratory comparison study The study was operated in the term, December, 2007 through January, 2008 3. Evaluation of results and their certification z scores in robust method # for each reported analytical results were calculated, and the values providing absolute value of z score more than 3 were rejected as outliers. Then, Average, 95 % 3

confident interval(u95%) and standard deviation(sd) were calculated with the usual way. These values are shown in Table 1, average as certified value, U95% as uncertainty. Date of certification March 27, 2008 Laboratories cooperated for the certification (members of the interlaboratory comparison study) Analysis Center Co. Canon Corp., Torite Factory Chemicals Evaluation and Research Institute, Japan Environmental Giken Co., Dept. of Technology Environmental Technology Service Co., Hibiki Research Laboratory Harison Toshiba Lighting Corp., Development Technology Management Div. Horiba Ltd., Analysis Center Jo-etsu Environmental Science Center, Dept. of Inspection Kobelco Kaken Co., Applied Chemistry Div. Konika-Minolta Technology Center Inc., Material Technology Laboratory Mitsui Kagaku Analysis Center Co., Structural Analysis Lab. Nissan Arc Co., Research Div. Nittech Research Corp., Material Technology Div. Nitto Analysis Center Co., Trace Analysis Lab. Shimadzu Technoresearch Corp., Quality Assurance Div. SII Nanotechnology Co., Dept. of Applied Technology Sumika Chemical Analysis Service Ltd., Ehime Branch Sumitomo Metal Technology Inc., Wakayama Branch Tokai Techno Co., Environment Div. Toray Research Center Co., Inorganic Chemical Analysis Lab. 20 laboratories Distributor Japan Society for Analytical Chemistry Laboratory of preparation Environmental Technology Service Co., Ltd. ( Kitakyushu, Japan) Certification Officer Dr. Toshiyuki Hobo, Chairman of JSAC Committee on Reference Material, Japan Society for Analytical Chemistry (JSAC) 4

Information Service Japan Society for Analytical Chemistry Office: 26-2-304, Nishi-Gotanda 1 chome, Shinagawa, Tokyo 141-0031, JAPAN Phone (81)3-3490-3351 Fax (81)3-3490-3572 Issued: Apr. 16, 2008 5