200350 and 200355 Accelerometers



Similar documents
High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Velomitor Piezo-velocity Sensor

9000 Series Accelerometers Specifications

Low Frequency Velocity Sensor

Proximity Transmitters and Seismic Vibration Transmitters

3500/40M Proximitor* Monitor

1701/22 FieldMonitor Management Interface Module

3500/62 Process Variable Monitor

Dynamic Pressure Charge Amplifier

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

2100 Eddy Current Probe Systems Specifications

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

3500/25 Enhanced Keyphasor*Module

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

IMVIB. Online vibration monitoring for Ariel compressors

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Givare NC-SRS 280 och 880

3500/93 System Display

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

How To Power A Schen

SEISMIC VELOCITY TRANSDUCER T1-40

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

3DLevelScanner II TECHNICAL DATA SHEET

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

Redundancy Module QUINT-DIODE/40

3500/22M Transient Data Interface

Inductive sensor NI10-M18-Y1X-H1141

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Technical Data Sheet. 3DLevelScanner

Power Supplies 3. SDN-P DIN Rail Series

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Combustion Dynamics Instrumentation

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Ten Port Multi-Band Antenna

PROXPAC XL Proximity Transducer Assembly

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

VIBRATION SWITCHES SOLID STATE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Differential Charge Amplifier

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

QR12 (1.22 ) Diameter Optical Encoder

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Product Overview 9100D

Differential-Hall-Effect based Sensors Series A5S

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Analog signal converters CC-E I/I Current / current isolators

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring

1788 Linking Device Specifications

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Relative pressure transmitter type 520

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

PRODUCT DATA 4397A/ 8A/ 9A. Description. Miniature DeltaTron Accelerometer Type 4397A DeltaTron Accelerometers Types 4398A, 4399A FEATURES USES

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Description. Dimensions. Features. precision works better

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Electronic, Digital and Mechanical Vibration Switches

CompactLogix Power Supplies Specifications

2002 IS Catalog. Page

Vibration Sensors. SKF Condition Monitoring

Product Data. Brüel & Kjær B. DeltaTron Range

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

TEIP11 I/P signal converter for standard signals. Measurement made easy

Capacitive Prox E2K-X

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SKF Microlog Analyzer Accessories Catalog

How To Use A Flowmeter

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

1442 Eddy Current Probe Systems Specifications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

3-Component Measuring System

Adjustment functions for both span and shift have been incorporated

HMI display Installation Guide

Pressure transmitter For general industrial applications Model A-10

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Mobrey Hydrastep and Hydratect

Transcription:

and Accelerometers Bently Nevada Asset Condition Monitoring Description The and Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster Pro Constant Current Direct Input Card 149811-02 and the Seismic Direct Input Card 164746-01. ACCELEROMETER The and Accelerometers are contained within a hermetically sealed, stainless steel case. The design provides an extremely rugged transducer, well suited for harsh industrial environments. Each transducer s top mounted, 2-pin connector (MIL-C- 5015) allows for easy installation and removal of the interconnecting signal cable. A ¼-28 threaded hole on the bottom of the casing accommodates multiple mounting options. The and Accelerometers contain a piezoelectric sensing device, which generates charge when subjected to vibration. This charge is then converted electronically to a differential voltage signal, which is proportional to the acceleration that is parallel to the sensitive axis of the transducer. Application Alert If housing measurements are being made for overall protection of the machine, consider the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. For housing measurements alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, exercise care in the physical installation of the transducer. Improper installation can result in a degradation of the transducer s performance and/or the generation of signals that do not represent actual machine vibration. Upon request, we can provide engineering services to determine the suitability of housing measurements for the machine in question and/or to provide installation Page 1 of 11

Specifications Application Alert Operation outside the specified limits will result in false readings or loss of machine monitoring. Parameters are specified from +20 to +30 C (+68 to +86 F) and 100 Hz unless otherwise indicated. Electrical Specification English Units SI Units Sensitivity (± 20%) (± 5%) Frequency Range (± 3dB) (± 3dB) 100 mv/g 100 mv/g 30 to 600,000 cpm 12 to 600,000 cpm 10.2 mv/(m/s 2 ) 10.2 mv/(m/s 2 ) 0.5 to 10,000 Hz 0.2 to 10,000 Hz Temperature Sensitivity See Graph See Graph Measurement Range ± 50 g ± 490 m/s 2 Transverse Sensitivity = 7% = 5% = 7% = 5% Amplitude Linearity ± 1% ± 1% Mounted Resonant Frequency Broadband Electrical Noise (1-10kHz) 1500 kcpm 1250 kcpm 350 µg 50 µg 25 khz 20.8 khz 3434 µm/s 2 491 µm/s 2 Output Bias Voltage 8 to 12 VDC 8 to 12 VDC Excitation Voltage 18 to 28 VDC 18 to 28 VDC Constant Current Excitation 2 to 20 ma 2 to 20 ma Settling Time (within 1% of bias) Output Impedance Discharge Time Constant = 2.0 sec = 5.0 sec < 150 ohms < 100 ohms = 0.3 sec = 0.8 sec = 2.0 sec = 5.0 sec < 150 ohms < 100 ohms = 0.3 sec = 0.8 sec Electrical Isolation (Case) > 10 8 ohms > 10 8 ohms Page 2 of 11

Environmental Specification English Units SI Units Operating Temperature Range -65 to +250 ºF -54 to +121 ºC Shock Survivability 5,000 g pk 49,050 m/s 2 pk Relative Humidity 100% relative, condensing, nonsubmerged Enclosure Rating IP68 IP68 Physical Specification English Units SI Units Size (Hex * Height) Weight 11/16 in * 1.65 in 7/8in * 2.06in 1.8 oz 3.3 oz 18 mm * 42.2 mm 22mm * 52.3mm 51 gm 94 gm Mounting Thread ¼-28 Female ¼-28 Female Mounting Torque (Max) 2 to 5 ft*lb 2.7 to 6.8 N*m Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear Housing Material Stainless Steel Stainless Steel Sealing Welded Hermetic Welded Hermetic Electrical Connector 2-Pin Mil-C-5015 2-Pin Mil-C-5015 Electrical Connection Position Top Top Page 3 of 11

Hazardous Area Approvals **Note: The does not have hazardous area approvals at this time. North America: ATEX: Ex ia / AEx ia IIC T4 Class I, Div 1 Groups A, B, C & D When installed per dwg 175825 T4 @ -54 C = Ta = 121 C Ex nl/aex na IIC T4 Class I, Div 2 Groups A, B, C & D When installed per dwg 175825 T4 @ -54 C = Ta = 121 C CSA 2007 1971585 II 1 G Ex ia IIC T4 LCIE 07 ATEX 6096 X T4 @ -54 C = Ta = 121 C II 3 G Ex nl IIC T4 LCIE 07 ATEX 6097 X T4 @ -54 C = Ta = 121 C EMC Directive (CE Mark) Standards to which Conformity is Declared CISPR 11 / EN 55011 Emissions: Class B, Group 1 EN61326 / A1 Emissions: Industrial Location EN61326 / A1 Immunity: Industrial Location Page 4 of 11

Ordering Options AA BB CC AA Mounting Stud 0 0 1/4-28 SS w/brass tip, 0.5 in 0 1 1/4-28 to M6 x 1.0 BeCu 0 2 1/4-28 to M8X1.25 BeCu 1 0 1/4-28 Adhesive Stud Mount 1 1 M6X1 Adhesive Stud Mount 1 2 M8X1.25 Adhesive Stud Mount BB Tolerance Option 0 0 100 mv/g +/- 20 % CC Approvals Option 0 0 No Approvals 0 1 Multi Approvals (North America, ATEX) AA BB CC AA Mounting Stud 0 0 1/4-28 SS w/brass tip, 0.5 in 0 1 1/4-28 to M6 x 1.0 BeCu 0 2 1/4-28 to M8X1.25 BeCu 1 0 1/4-28 Adhesive Stud Mount 1 1 M6X1 Adhesive Stud Mount 1 2 M8X1.25 Adhesive Stud Mount BB Tolerance Option 0 2 100 mv/g +/- 5 % CC Approvals Option 0 0 No Approvals Page 5 of 11

Accessories Title Part Number Notes and Accelerometer Manual Trendmaster Pro System Manual 164803-01 162411 Trendmaster DSM Datasheet 149831-01 Trendmaster DSM Manual 149823-01 M6X1 Mount Stud 164372 ¼ - 28 Mount Stud 164373 M8X1.25 Mount Stud 167559 ¼-28 Adhesive Mount Kit 167563-10 See Description Below M6X1 Adhesive Mount Kit 167563-11 See Description Below M8X1.25 Adhesive Mount Kit 167563-12 See Description Below Splash Proof Cable **Not recommended for the CB2W100 AAA AAA = 015 ft AAA = 125 ft AAA = 032 ft AAA = 150 ft AAA = 064 ft AAA = 200 ft AAA = 112 ft Page 6 of 11

Standard Cable No Armor 2-conductor twisted, shielded 22 AWG cable with 2-socket moisture-resistant female connector at one end, terminal lugs at the other end. Standard Cable with Armor 2-conductor twisted, shielded 22 AWG cable with 2- socket moisture-resistant female connector at one end, terminal lugs at the other end. 9571 AA Minimum Length - AA = 02 ft Maximum Length - AA = 99 ft Increments of 01 ft 84661 AA Minimum Length - AA = 03 ft Maximum Length - AA = 96 ft Increments of 01 ft Adhesive Mounting Kits Adhesive studs are sold in kits containing two threaded studs and two mounting pads. Also in the kit is a packet of acrylic adhesive and materials to mix its two components. A scouring pad and alcohol wipe are provided for preparing the mounting surface. Adhesive Specification English Units SI Units Temperature Range -67 to +250 ºF -55 to 121 ºC Cure Time 24 Hour 24 Hour Application Alert Use of adhesive will attenuate high frequency components that may be present Page 7 of 11

DIMENSIONAL DIAGRAM ACCELEROMETER Page 8 of 11

Page 9 of 11

Temperature Sensitivity Curve FREQUENCY AND PHASE RESPONSE CURVES Frequency Response db 1 0-1 -2-3 0.1 1 10 100 1000 10000 Hz Phase Phase Angle 100 50 0-50 -100 0.1 1 10 100 1000 10000 Hz Page 10 of 11

Frequency Response 1 0 db -1-2 -3 0.1 1 10 100 1000 10000 Hz Phase 100 Phase Angle (deg) 50 0-50 -100 0.1 1 10 100 1000 10000 Hz Copyright 2003. Bently Nevada LLC. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-energy.com/bently All rights reserved. Bently Nevada and Trendmaster are trademarks of General Electric Company. Page 11 of 11