Technical Report An Analysis on the Use of LED Lighting for Video Conferencing



Similar documents
Lutron Linear Recessed and Video Conference Fixture Solutions

Lutron Linear Recessed and Video Conference Fixture Solutions

A1.5 Classroom Standards

Open Office Plan. Function and Orientation. Space Characteristics. Material Properties Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

The Little black book of lighting For Film and Video

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

Video Conference Indirect Wash LED Fixture

LED DIMMING A HELPFUL GUIDE...

T5 LongLast. GE Lighting DATA SHEET

A Philips Ledalite Chopstick LED Semi-Indirect Luminaire

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Solid State Lighting Definitions for Functional and Decorative Applications

LED Tubular Lamp / Kit Guide

T5 Watt-Miser Linear Fluorescent lamps

Recessed. EvoKit LED Retrofit Kits Gen 3

Beyond Built-in: Why a Better Webcam Matters

Evolve LED Area Light

Videoconferencing Room Guide

LED Fresnel Super Series...1. LED Softlight Series...9. Super LED F Super LED F Super LED Piccolo F Super LED F 10...

Energy efficient lighting for your home find out more.

Lighting Control in the Office Space

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

Light Control and Efficacy using Light Guides and Diffusers

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

D E F I N E V E L O D O. Telemedicine Room Design PROGRAM GUIDE. CTEConline.org

Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4:

Guide to new, energy-efficient lighting technologies for your business

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

High / Low Bay Datasheet

T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO

Linear Recessed Center Basket Fixture. Lutron

Lumination LED Luminaires

General Lighting Recommendations

Lemnis public lighting BETTER VISIBILITY WITH LESS ENERGY

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

DOSSIER EN m CONCISE DESCRIPTION OF THE STANDARD. 2nd edition, june 2012

Low / High Bay Datasheet

Exterior Lighting for Energy Savings, Security, and Safety

Evolve LED Area Light

Basics of Dimming. ISC Learning Centre

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

Visionary, versatile surgical lighting. Harmony vled Surgical Lighting System

Evolve LED Area Light

Indoor/Outdoor Sign Lighters Energy-efficient, modular fixtures for commercial signage and retail displays

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

Session 15 Lighting Fundamentals

Appendices: Ergonomic Case Study of an Audiologist Performing Visual Reinforcement Audiometry

Home lighting. Bright ideas for energy savings

Green Building Handbook for South Africa Chapter: Lighting Luke Osburn CSIR Built Environment

Product specifications

OptimizedIR in Axis cameras

High / Low Bay Datasheet

GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work

Dimmer and Bulb Compatibility

A New Benchmark in LED Lighting Technology and Design.

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

2 Inch LED Recessed LIGHTING

Energy-efficient lighting

Code Compliance Commercial Application Guide

Lighting (Illumination) in Warehouses

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

Innovative. Lum. Flux** [lm]

Industrial Solutions. Made to order. Imagine lighting as versatile as the industries it serves.

LED Luminaire Design Guide

9W T8 LED TUBE 2FT GENERAL INFORMATION

space types - design briefs

WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception

Lighting food. Brightening faces.

Cree XLamp MX-6 LEDs Data Sheet

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Lumination LED Luminaires

Adaptive strategies for office spaces in the UK climate

No-Cost LED street lighting modernization

AOK i Series LED High Bay / Flood / Tunnel Light

Publication II Elsevier Science. Reprinted with permission from Elsevier.

Efficient and reliable operation of LED lighting is dependent on the right choice of current-limiting resistor

Tune the light to meet the specific needs of each crop

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

CA Title Lighting and Receptacle Control Requirements for Commercial Buildings. Michael Jouaneh, CEM, LEED AP July 1, 2014

LED DOWNLIGHT ONE 50XX SERIES

LED Lamp 15W AR111C. A New Experience in Light

Provincial Health Services Authority. Telehealth Room Preparation Generic Guidelines

Technical application guide

Features. High Brightness LED Light source

Why Philips LEDtube? Leander Bloot Product marketing LEDtubes LED Lamps EMEA January January 2014_BG LS & E LEDlamps

How To Use A Lutron Power Supply

WHITE PAPER. P-Iris. New iris control improves image quality in megapixel and HDTV network cameras.

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

ECOPTIMO T8. Version IRIS 2002,S.A. C/San Agustin, Madrid SPAIN T F

Analog and Digital Fluorescent Lighting Dimming Systems

GUIDE TO THE ARTIFICIAL LIGHTING OF HOCKEY PITCHES

FLEX by 3M Light Module System

Business Energy Rebates Application

Evolve LED Flood Lighting EFH1

2D & 3D TelePresence

8. EXTERIOR SITE LIGHTING

Why Philips LEDtube? LED Lamps EMEA February February 2015_BG LS & E LEDlamps

Transcription:

An Analysis on the Use of Lighting for Video Conferencing Jim Yorgey, PE Frank Neher, Joe Volkert, and Christina Katrinak March 14, 2016 03/2016 Lutron Electronics Co., Inc. I P/N 367-2622 REV A

1) Abstract... 3 2) Executive Summary... 3 3) Types of Fixtures... 4 4) Types of Spaces... 4 5) Fluorescent vs Fixture Solutions.............................................. 5 6) Optimized Solutions... 6 7) Modeling vs Performance... 6 8) Case Study... 7 a) Procedure... 8 b) Results... 9 c) Discuss Results...13 9) Conclusion...14 10) Further Reading...14 11) Appendix A: Raw Data...15 2 Lutron

Abstract Lighting a Video Conferencing (VTC) environment presents a unique challenge simultaneously providing equal, excellent visual access to both verbal and non-verbal communications of participants in the room as well as participants in remote locations. Lighting for VTC applications must accommodate the visual requirements of the people and the camera, and provide visibility of any display materials, especially to remote participants. Achieving the proper lighting balance requires the right combination of fixtures and the right combination of control strategies. Linear fluorescent sources have long been used to provide effective, uniform lighting in VTC environments. The purpose of this paper is to show that similar, or better, results can be achieved using solutions, and to present the additional benefits associated with using s. Dimming controls are essential to creating the correct solution in VTC environments regardless of the source, and appropriate control solutions are also detailed. Presented in this whitepaper Look at both fluorescent and fixture options in a typical VTC space Detail the optimized lighting layout and control scenarios Discuss lighting selection, advantages, and important considerations Demonstrate that the performance and savings can be easily and accurately modeled The overall goal of this paper is to help designers and users become more comfortable with the use of fixtures and controls in VTC environments, to understand the advantages of the sources, and to be able to confidently design with them. Executive Summary Even, flicker-free lighting for VTC rooms can be achieved using either fluorescent or fixtures with the proper controls. From a facility management and performance perspective, using fixtures provides additional and important advantages including Significant energy savings Long product life reduces maintenance and operations costs Ability to comply with current and pending energy code changes Lower environmental impact sources contain no mercury and no disposal risks 3 Lutron

Types of fixtures During a video conference the camera doesn t see the way the human eye does. Improper lighting can cause the camera to produce saturated images or images with dark shadows on them, resulting in poor picture quality for remote participants. The right combination of strategically placed fixtures improves vertical illumination, creates uniform lighting on surfaces and participants, and with the addition of controls, enhances the ability to adjust contrast in the space. Critical contrasts include participant-to-rear-walls participant-to-side-walls participant-to-work-surface display-wall-to-video-display Other factors, including room color and color/texture of furnishings, can also contribute to or detract from effective VTC room design. To further ensure image clarity, it is important to use a manufacturer that offers fluorescent fixtures with dimming ballasts and/or fixtures with dimmable drivers in various form-factors to fit a variety of different space types, and applications. In either case, a combination of 1x2 and 2x2 indirect fixtures provides both vertical and horizontal illumination, and helps produce images that have better contrast and sharpness. The right combination of fixtures ensures high-quality lighting on the participants, walls, and table surfaces, and the area around the display, screen, or monitor. Types of Spaces These lighting guidelines are particularly advantageous in the following space types: VTC rooms Telepresence rooms Distance learning spaces Training rooms Board rooms and conference rooms that incorporate video capabilities 4 Lutron

Fluorescent versus Fixture Solutions Fluorescent fixtures have proven to provide even, controllable lighting in VTC spaces, and lighting designers may be hesitant to veer away from fluorescent solutions without a clear understanding that s offer equivalent lighting with additional advantages. fixtures and controls are becoming less expensive and more widely available, and now they offer a viable alternative design solution, delivering benefits that make fixtures highly desirable in virtually any VTC application: Efficient s use less energy initially, and they save energy at a roughly 1:1 ratio as they are dimmed Uniform light levels/consistent color temperature s deliver more consistent color temperature, with little degradation or color shift over their lifetimes Longer lifetime s consistently deliver 50,000+ hour life, even longer when s are dimmed Lower heat dissipation s dissipate very little heat, further increasing energy savings by reducing demand on HVAC cooling systems Guaranteed compatibility The light source is included in the fixture, ensuring compatibility between module and driver. By choosing a manufacturer who specifically provides fixtures and controls together, you can guarantee compatibility and smooth, flicker-free dimming fixtures provide the same glare free lighting as their fluorescent counterparts The selection of an appropriate driver is not limited to just making sure it matches the module being used. The driver is the primary component that determines the best-possible dimming capabilities of the lamp or fixture. It is also important to understand what mechanism the driver uses to achieve dimming: pulse-width modulation (PWM) or constant current reduction (CCR). Drivers using CCR are critical for video conference applications in order to ensure good performance on camera. More information about PWM vs CCR is available in the Whitepaper, Dimming s via PWM and CCR from Lutron Electronics. 5 Lutron

Optimized Solutions The IES standard IESNA DG-17-05 goes into great detail to explain the importance of environment in creating a space ideal for VTC functions. It provides background on optics and details explaining what needs to be done to successfully implement a VTC space. Among the details, it describes what efforts should be taken to ensure appropriate lighting within a space. The standard calls out ideal specifications for light sources, including a 3000-3500K range for CCT and a CRI of 80 or higher. It also emphasizes the importance of meeting the minimum light level requirements of the camera and providing even contrasts in lighting throughout different parts of the room in order to prevent saturation and washouts. The standard strongly suggests the use of controls in order to achieve this balance of light levels, to provide the minimum quantity of light without being over lit, and to provide good contrast ratios. A dimming system facilitates the ability to adjust the light levels within the space in order to ensure the proper balance of light. Modeling vs Performance When designing a space with such specific requirements, it is vital that the solution can be modeled and the results accurately predicted. Predictive models allow for a designer to see what the solution will look like in terms of fixture layout and light output, without investing the time and money in a physical mockup of the space. A trusted model delivers confidence that the proposed solution will meet the space requirements prior to purchasing a piece of equipment. Predictive modeling can be done using IES files and modeling software. By modeling the space, designing and tweaking the fixture layout, and including the IES file photometric data for the specific fixtures the actual photometric layout of the room can be created and analyzed. The model enables the user to observe and/or analyze the light levels throughout the space as well as the contrasts between dark and bright spots. This allows for further consideration regarding fixture type and placement as well as the application of control systems. 6 Lutron

CASE STUDY IMS Example of a typical VTC space a combination of fixtures is used to provide the right light on every room surface. Figure 1 - Fixture layout. Room is 23' 3" x 12' 10" with 8' ceilings. 1. Wallwash fixtures Uniformly illuminate rear and side walls from task height to ceiling, providing good contrast between participants and the background for a quality video image. 2. Indirect wash fixtures Illuminate participants with vertically focused lighting (between a 45º and 60º angle), minimizing shadows on their faces 3. Recessed downlights Illuminate the tabletop surfaces horizontally, minimizing shadows on faces and providing adequate task lighting, illuminate the presentation area with flexible lighting, and adjust contrast on presenters and wall displays. 7 Lutron

Procedure: STEP 1 fixtures were installed in the selected VTC room, and measurements were taken at 100% light output. Table 1 shows the resulting measurements, taken at critical locations, of the lighting installation. STEP 2 The fixtures were replaced with fluorescent fixtures, and measurements were taken again, (Table 1) as shown below. The measured data was used to determine whether an system performs as well as a fluorescent system in a VTC environment (Table 2). STEP 3 The next issue is to determine whether significant energy savings are realized by using s in a VTC-optimized scenario. The energy consumption of the fluorescent fixtures and the fixtures was measured in a test setup, and performed over the entire dimming range (Table 3). This information allowed for comparison of potential energy savings between the two solutions. STEP 4 The lighting was dimmed to the correct levels for optimal VTC purposes as outlined in the IES standard (Tables 4 and 5). STEP 5 The next thing to consider was how the performance of the system lined up with the model. A model of the test setup was prepared using the IES files and software. The collected data from the case study was then compared to what the model predicted (Table 6). 8 Lutron

Measurement Points: Figure 2 - Wall Measurement Points Figure 3 - Table Measurement Points IMS Case Study Results This white paper specifically addresses the results of a case study that compared the use of fluorescent fixtures and controls versus fixtures and controls in a VTC room. The data will demonstrate that solutions can provide the same, flicker-free 1% dimming that was previously only available with a fluorescent solution. Summarized data from the case study can be found below. The raw data can be found in Appendix A. 9 Lutron

Table 1: Fluorescent vs Average Luminance Fluorescent (Cd/m^2) (Cd/m^2) Average from walls at 6 ft (sides) 60.3 67.9 Average from walls at 3 ft (sides) 63.4 67.3 Average from Right Wall 102.3 108.0 Average from Front Wall 25.5 21.4 Average from Back Wall 55.9 76.3 Average from Table 78.00 71.7 Average from Face Looking at Camera 59.4 67.7 Average from Face 45 degree down 11.4 11.6 Average from Face Left Light 45.7 45.2 Average from Face Right Light 46.0 42.6 Table 2: Fluorescent vs Data Variance Fluorescent (Cd/m^2) (Cd/m^2) Variance from walls at 6 ft 1038 1584 Variance from Walls at 3 ft 1736 1965 Variance from Right Wall 286 295 Variance from Front Wall 9 13 Variance from Back Wall 40 139 Variance from Table 117.8 82.0 Variance from Face Looking at Camera 150.2 27.7 Variance from Face 45 degree down 6.2 21.0 Variance from Face Left Light 76.0 59.7 Variance from Face Right Light 62.5 31.3 10 Lutron

Table 3: FL vs Energy Usage throughout Dimming Range 2 x 2 2 Lamp 50 W T5 Fluorescent VTC Fixture H3DT550GU210 2 x 2 45 W VTC Fixture (1.07 A) L3DA4U1UMN-LA107 % Light Level Fixture Input Power (W) % Power Savings Fixture Input Power (W) % Power Savings 100% 92.5 0% 44.8 0% 90% 86.9 6% 39.9 11% 80% 80.1 13% 35.0 22% 70% 69.0 25% 30.6 32% 60% 60.0 35% 25.7 43% 50% 52.1 44% 21.3 53% 40% 42.3 54% 16.9 62% 30% 37.1 60% 13.4 70% 20% 28.2 69% 9.3 79% 15% 25.4 73% 7.2 84% 10% 22.8 75% 5.3 88% 5% 21.1 77% 3.3 93% 1% 20.1 78% 1.7 96% 11 Lutron

Table 4: Optimized Average Luminance (Cd/m^2) Average from walls at 6 ft 29.0 Average from walls at 3 ft 26.0 Average from Table 21.7 Average from Face Looking at Camera 17.9 Table 5: Optimized Maximum Ratio (Max:Min) (Cd/m^2) Max Ratio from walls at 6 ft 1.44:1 Max Ratio from walls at 3 ft 1.8:1 Max Ratio from Right Wall 1.44:1 Max Ratio from Back Wall 1.6:1 Max Ratio from Faces - Looking at Camera 1.3:1 Table 6: Predicted vs Measured Luminance % Difference Table: Point A 7.7% Table: Point B 18.6% Table: Point C 26.1% Table: Point D 3.9% Table: Point E 14.4% Table: Point F 2.9% Table: Point G 2.9% Average 10.9% 12 Lutron

DISCUSS RESULTS sources applied in the same way as their fluorescent counterparts can provide equivalent light with lower energy use. As shown by the average luminance data in Table 1 for for the two solutions at 100%, the light output of the solution is capable of producing the same quantity of light as the fluorescent solution. Looking at the variance data in Table 2, we can see that the variation in light output across the different surfaces is also very similar. The variance in the data set is a measurement in the spread of the values away from the mean of the set. In this analysis, the measurements can be used to represent overall difference in light measurements along a surface. It cannot be determined from this data set, what an acceptable variance is for each surface, but to compare the overall light environment provided by the two solutions. If looked at surface-by-surface, the data set variances between the fluorescent and solutions tend to mirror each other along a surface. This illustrates that the fluorescent and solutions provide equivalent light outputs, and the variance in light level is most likely due to the fixture layout, rather than differences in the light sources themselves. As discussed previously, solutions have intrinsic benefits. The primary benefit addressed by the data in this analysis is that of energy savings. The direct comparison of equivalent 2 x 2 and fluorescent fixtures shows that at 100% output, the fixture uses about half the power of the fluorescent fixture. This also saves energy linearly resulting in even further energy savings as the fixture is dimmed. This is especially true as the fixtures are dimmed toward their low end. This is very important to consider since these fixtures should be paired with a dimming system and dimmed down in order to optimize the light output. For this analysis, the optimized solution was implemented with all light source types present in the room, including the wallwash fixtures, indirect wash fixtures, and recessed downlights. Having already tested, analyzed, and determined that the VTC fixtures could output light equivalent to a fluorescent VTC fixture, it was most prudent to analyze an optimized solution as it would appear in normal use than to prepare an optimized solution with just the indirect wash fixtures. The values for this optimization were found to be wallwash at 30%, indirect wash at 20%, and recessed downlights at 10%. The IES standard suggests a maximum luminance ratio of 1.5:1 from the maximum to minimum of the walls behind the participants or from the faces of participants in order to provide quality video feed from the space. The results in Table 5 show that the optimized solution maximum to minimum ratios were all around 1.5:1. Table 4 shows that the average light level on the table while achieving these proportions was at an acceptable meeting light level. 13 Lutron

Finally, the predicted vs measured data in Table 6 proves that the results of using a video conferencing fixture layout with control system can be accurately predicted. In this data set, there is an average variation of 10.9% between what was predicted and what was experienced on site. The difference can be attributed to the slight variation in fixtures, variations in the surfaces within the room, as well as slight changes in the control system adjusting the light levels up and down. What this data does confirm is that the results can be predictably modeled within a reasonable margin of error. This allows for designing and tweaking of VTC room lighting and control design to gain the desired results prior to the investment in equipment or time on site. Conclusion As sources become more available and more cost effective, lighting designers can be confident that s deliver the performance and flexibility their clients have come to expect from fluorescents. Knowing that s can offer equivalent light levels empowers the client to focus on the intrinsic benefits of an solution, namely energy savings and longer life. Understanding those benefits, it becomes critical to be able to reliably design a solution with confidence and without requiring substantial investment. The fact that these solutions can be accurately modeled, and the results reliably predicted, is great news for good design and experimentation without requiring investment of time and resources. Seeing the equivalence between sources, understanding the intrinsic benefits, and being able to accurately model and predict performance removes any obstacles for solution and opens the door for them to be used as the new standard for VTC spaces. Further Reading For more information on how to select the correct combination of lamps, drivers and controls, read the Controlling s whitepaper from Lutron. 14 Lutron

Appendix A: Raw Data from IMS Case Study Fluorescent vs at 100% Wall Data Location Placement Height* Right wall Front wall Back wall A B C D E F G H Fluoresecent (Cd/m 2 ) (Cd/m 2 ) 6 ft 82 75 3 ft 93 107 6 ft 112 119 3 ft 123 123 6 ft 87.5 114 3 ft 116 110 6 ft 26 24 3 ft 25.5 17 6 ft 31 26 3 ft 24 22 6 ft 24 22 3 ft 22.5 17.5 6 ft 64 90 3 ft 55 80 6 ft 56 73 3 ft 48.5 62 Table Data Location Placement Fluorsecent (Cd/m 2 ) Table (Cd/m 2 ) A B 60 77 C 69 86 D 85.7 70.5 E 84.5 71 F 83.8 65.5 G 85 60 Notes: See Measurement Points 1 diagram * Height is measurement from the floor # See Measurement Points 2 diagram 15 Lutron

Simulated Occupant Data Location Placement Fluorsecent (Cd/m 2 ) Looking at camera 45 Degree angle down Left Light Right Light (Cd/m 2 ) H 45.5 66 I 74.4 64 J 65 77 K 64 66 L 48 65.5 H 8.3 8.5 I 11.8 12.7 J 14.3 18.6 K 13.2 11.5 L 9.6 6.7 H 35.4 42 I 58.8 57 J 42.3 44 K 48.7 47 L 43.3 36 H 46.7 38 I 43 44 J 47.7 51 K 57.1 43 35.3 37 Notes: See Measurement Points 1 diagram * Height is measurement from the floor # See Measurement Points 2 diagram 16 Lutron

Optimized 2 x 2 VTC is 20%; IW is 30%; Finiré at 10% Wall Data Location Placement Height* (Cd/m 2 ) 6 ft 25 A 3 ft 28 6 ft 36 Right wall B 3 ft 34 6 ft 27 C 3 ft 31 6 ft 9 D 3 ft 8 6 ft N/A Front wall E 3 ft screen 6 ft 9 F 3 ft 7 6 ft 30 G 3 ft 19 Back wall 6 ft 27 H 3 ft 18 Table Data Simulated Occupants Location Table Placement# (Cd/m 2 ) A 19 B 29 C 18 D 24 E 18 F 24 G 20 Location Table Placement# (Cd/m 2 ) H 15.5 I 20 J 19.5 K 18.5 Looking at 16 camera Notes: See Measurement Points 1 diagram * Height is measurement from the floor # See Measurement Points 2 diagram 17 Lutron

Optimized Predicted vs Measured Table Data Location Placement (fc) Predicted (fc) % Difference Table A 30 27.7 7.7% B 34.5 28.1 18.6% C 37.5 27.7 26.1% D 35.5 34.1 3.9% E 37.5 32.1 14.4% F 34.5 35.5 2.9% G 34.5 35.5 2.9% Notes: See Measurement Points 1 diagram * Height is measurement from the floor # See Measurement Points 2 diagram 18 Lutron