How is Dew Point Measured Reliably?



Similar documents
Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Rense Product Range. Customized Humidity Solutions. Rense Product Range

ThermoSorb Desiccant Dryers

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

USB-500/600 Series Low-Cost Data Loggers and Accessories

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Continuous Monitoring System. / REDUCE THE RISKS OF NON-COMPLIANCE & LOST PRODUCT IN GxP ENVIRONMENTS

ThermoStar Refrigeration Air Dryers

Instruction Manual. T3111 T3111L T3111P T3111Ex

USB-500/600 Series Low-Cost Data Loggers and Accessories

Dew-Point Measurement Solutions

Fundamentals of Mass Flow Control

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Kompressoren. Adsorption Dryer AD

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Adsorption air dryers ADS 1 215

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

USB-500 Series Low-Cost Data Loggers and Accessories

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Data Loggers for Real Time Temperature Monitoring - WiFi

WiFi Edition

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Pressure Dew Point Probe / Application Information

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

EM Family Datasheet. Overview. Easy to install at any scale

Temperature Alert. LAN-based Temperature and Humidity Data Logger

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Vaisala Weather Transmitter WXT510 The Most Essential of Weather

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

GPC. How do I call up the bid text for a selected unit? Why does the GPC calculate the surface reserve and not the capacity reserve?

HOBO U14 Data Logger User Manual

Medical Air Systems: Scroll

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

HIH-4000 Series Humidity Sensors

Affordable wireless monitoring without compromise

USER S GUIDE Humidity and Temperature USB Datalogger

Desiccant Air Dryers Heatless, Heated and Heated Blower

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Temperature & Humidity SMS Alert Controller

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

FT-1000/GPS-N. System of remote monitoring and control of physical

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

Refrigeration Compressed Air Dryer Buran Ultrapulse

Current Monitoring Kit

A/C refrigerant system, overview

MP-4000 Alarm List (Software version or later)

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Technical data. Danfoss DHP-A

2.24. Pump Controller 704. Data Sheet

Duct Humidity Transmitter

Online Infrared Flue Gas Analyzer Gasboard 3000

Rotary screw compressors kw 5,5 7, , bar MODULO

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

Monitoring manufacturing, production and storage environments in the pharmaceutical industry

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

COMBIMASS. Technical Data COMBIMASS eco-bio +

BIOMEDICAL REFRIGERATORS

Electromagnetic Flow Meter

Typical Aluminum GFM Mass Flow Meter

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

User Guide. Temperature and Humidity Datalogger. Model 42280

Data Logging Solutions from Lascar Electronics

Current Monitoring Kit QUICK START GUIDE

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

THE HUMIDITY/MOISTURE HANDBOOK

Installing a Probe. Typical Installation

Microwave Meter. Instruction Manual

USB-Based Temperature & Humidity Sensor

Models SFP33 & SFP32 Pressure Transmitters

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Technical Overview CM-2 Climate Monitor. Get yours direct at:

TC-9102 Series Surface Mount Temperature Controllers

Freezers - Ultrafreezers. Platilab & Irilab Series

Precision Humidity Measurement for Pharmaceutical Fluid Bed Tablet Coating

REAL-TIME DUST AND AEROSOL MONITORING

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

DUST EMISSION MONITORING SYSTEM

REFRIGERATED COMPRESSED AIR DRYERS

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Wireless Data Logger Monitoring Systems

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Compressed Air Filters

Screw Compressors ESM Fixed Speed & VS Variable Speed

Model: DC-A2IO Advanced HVAC Controller

Heating and air-conditioning industry

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Digital inductive conductivity transmitter

On the Use of Data Loggers in Picture Frames (And Other) Micro Climates

Kompressoren. Oil Water Separators OWS

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Application Requirement

EasyTrack 2 Accessories List

Transcription:

How is Dew Point Measured Reliably? Air compression increases vapor pressure and thus dew point. = water vapor Vapor pressure Frost point Saturation - 0 C + Dew point Monitoring with alarming and real time trending What is dew point? Dew point is the temperature to which air must be cooled for water vapor in it to condense into dew or frost. At any temperature there is a maximum amount of water vapor that the air can hold. This maximum amount is called water vapor saturation pressure. Addition of more water vapor results in condensation. Why is moisture problematic? Condensation in pressurized air is problematic because it causes blockages in pipes, machinery breakdowns, contamination and freezing. What is the effect of pressure on dew point? Air compression increases water vapor pressure and thus dew point. It is important to take this into consideration if you are bleeding the air to atmosphere before taking a measurement. The dew point at the measurement point will be different from the dew point in the process. What is the typical range of dew point? Dew point temperatures in compressed air range from ambient down to -80 C (-112 F), sometimes lower in special cases. Compressor systems without air drying capability tend to produce compressed air that is saturated at ambient temperature. Systems with refrigerant dryers pass the compressed air through a cooled heat exchanger, causing water to condense out of the air stream. These systems typically produce air with a dew point no lower than 5 C (41 F). Desiccant drying systems absorb water vapor from the air stream and can produce air with a dew point of -40 C (-40 F) and drier if required. How Dew Point is Reliably Measured?* Select an instrument with the correct measuring range. Understand the pressure characteristics of the dew point instrument: Some instruments are not suitable for use at process pressure. They can be installed to measure compressed air after it is expanded to atmospheric pressure, but the measured dew point value will have to be corrected if pressure dew point is the desired measurement parameter. Install the sensor correctly: Follow instructions from the manufacturer. Do not install dew point sensors at the end of stubs or other dead end pieces of pipe where there is no airflow. *Some principles of dew point measurement apply to all types of instruments, regardless of manufacturer.

Consider the following when installing a Vaisala dew point instrument: A. The most common installation for a dew point sensor isolates the sensor from the compressed air line. This is accomplished by installing the sensor in a sample cell and connecting the cell to a T in the compressed air line at the point of interest. A small amount of compressed air is then bled past the sensor. The cell should be made of stainless steel and connected to the T with tubing (1/4 or 6 mm). It is useful to install an isolation valve between the cell and the air line. This enables easy installation and removal of the sensor. B. A flow-regulating device is necessary to control to airflow past the sensor. The desired flow rate is only 1 L/min (2 scfh). The regulating device can be a leak screw or a valve. To measure pressure dew point, the regulating device is installed downstream of the sensor, so that when the isolation valve is opened, the sensor is at the process pressure. To measure dew point at atmospheric pressure, the regulating device should be installed upstream of the dew point sensor. C. Do not exceed the recommended flow rate. When measuring pressure dew point, an excessive flow rate will create a local pressure drop at the sensor. Because dew point temperature is pressure sensitive, this will create an error in the measurement. D. The best tubing material is stainless steel (SS). Nonmetallic tubing can absorb and desorb water vapor, creating a lag in measurement response. If SS tubing is not available, consider using PTFE or other materials that do not absorb water. Avoid the use of clear plastic tubing or yellow rubber tubing. E. It is possible to reduce installation costs for permanent dew point instruments by installing the sensor directly in the compressed air line. In these cases it is important to choose a location where the sensor has adequate airflow and where the temperature of the compressed air is at or near ambient Choose the Right Dew Point Instrument for Optimized Compressed Air Quality Hand-held dewpoint and temperature meter Configurable fixed mount transmitter OEM models Optimal measurement range for each product DMT152 DM70 DMT340 DMT143 DPT146 DMT242 DMT132-80 -70-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 Dew point temperature ( C) Increasing the life of your compressed air system, improving process quality and lowering costs is now easier than ever. Our unique sensor technologies cover the full dew point range for practically any compressed air system. Vaisala DRYCAP and HUMICAP sensor technologies ensure accurate, reliable measurements with excellent long term stability and fast response. All Vaisala sensors withstand exposure to contaminants like water spikes, ambient humidity, compressor oil and chemical impurities. They also have the fastest wet-to-dry response time on the market and minimal drift that allows for a long 2-year calibration interval. The DRYCAP polymer sensor technology incorporates unique innovations such as the patented auto-calibration feature. This auto calibration maintains the specified accuracy by warming the sensor at set intervals to indicate a possible offset drift to the measurement electronics for automatic correction.

Dewpoint Instruments DMT340 Transmitter, Configurable fixed mount -60... +45 C (-76... +113 F) T d with ±2 C (±3.6 F) accuracy Configurable with various options Display/keypad Data logging and Relay module Multiple probe option Integrated data logging with over four years of measured history Multilingual menu (EN, CN, DE, FI, FR, JP, RU, SE, SP) Read more or download the datasheet at www.vaisala.com/dmt340 DMT132 Transmitter for Refrigerant Dryers -20... +50 C (-4... +122 F) T d Affordable, yet highly accurate: ±1 C (±1.8 F) in refrigerant dryer measurement range Excellent long-term stability resistant to compressor oil Low powered, 10... 28 VDC Pressure up to 20 bar HUMICAP sensor technology Read more or download the datasheet at www.vaisala.com/dmt132 DMT143 Miniature Dew Point Transmitter -60... +30 C (-76... +86 F) T d with ±2 C (±3.6 F) accuracy Small size for compact industrial dryer applications Stable and cost-efficient LED alarm for exceeded dew point level Read more or download the datasheet at www.vaisala.com/dmt143 DPT146 Transmitter with Integrated Pressure Measurement -60... +30 C (-76... +86 F) T d with ±2 C (±3.6 F) accuracy The first transmitter with combined dew point and pressure measurement Compatible with Vaisala Hand-Held DM70 for easy spot-checking, local display and data logging Pressure up to 10 bar DRYCAP and BAROCAP sensor technology Read more or download the datasheet at www.vaisala.com/dpt146 DMT242 Transmitter for Industrial Dryer Applications -60... +60 C (-76...+140 F) T d with ±2 C (±3.6 F) accuracy Sensor options for desiccant and refrigeration dryers Pressure up to 20 bar Read more or download the datasheet at www.vaisala.com/dmt242 DMT152 Transmitter for Low Dew Point Measurement -80... -10 C (-112... +14 F) T d with ±2 C (±3.6 F) accuracy Measurement range down to -80 C (-112 F) Read more or download the datasheet at www.vaisala.com/dmt152

Vaisala viewlinc Monitoring, Alarming and Reporting Software viewlinc viewlinc software provides monitoring with alarming and real-time data trending for dew point and more. viewlinc allows users to monitor environments measured with Vaisala devices via any current Web browser. Ideal for large-scale, multifacility systems and standalone applications, viewlinc uses your existing network, eliminating the cost of installing and maintaining a dedicated network for a continuous monitoring system. The newest build of viewlinc version 4.3 features a mobileoptimized interface for remote monitoring, reporting and alarm management. Along with the location-based reporting and data logging capability, mobile optimization allows users to act on alarms immediately via SMS message. viewlinc also provides timezone based reporting, making the reporting functions correlate with the localized time of data collection and alarming. With software versions in English, German, French, Swedish, Chinese, Japanese, Spanish and Portuguese, the system is ideal for applications ranging from singlelocation monitoring up to globally standardized monitoring across hundreds of locations. viewlinc Allows Users to: View real-time data in a graphical format and generate historical data trending and alarm reports delivered automatically and on your schedule; Receive visual, audible or email alarms if conditions go out of specification or if the network goes down; Analyze events, such as alarms, acknowledgements or communication problems; Schedule transfers of data into graphs and tables; Create pre-configured comments for alarm notifications for specific monitored areas Assign permission to restrict users' views, thresholds setting abilities, or alarm acknowledgment by personnel areas of responsibility; Customize alerts according to shift schedules and escalation procedures.

Connectivity Options & Hardware DMT340 Transmitter with LAN or WLAN connectivity Existing Network 40. 1 C 75.8 RH Remote Monitoring, Alarming and Reporting Remote Alarming 40. 1 C 75.8 RH DMT132, DMT143, DMT152, or DPT146 with DL4000 data logger and an Ethernet interface or direct to a PC DL4000 Data Logger Ethernet Interface Existing Network Remote Monitoring, Alarming and Reporting Remote Alarming DL4000 Data Logger For more information, visit www.vaisala.com or contact us at sales@vaisala.com Ref. B211180EN-B Vaisala 2014 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications technical included are subject to change without notice.