DLP-PU/E Instruction Manual



Similar documents
GWS250 Series Instruction Manual

MCR1900 Media Converter 19-Slot Chassis

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Power Supplies 3. SDN-P DIN Rail Series

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

IO-RM3 3-Stage Relay Module

Instruction Manual PFE300S 500S SERIES. TDK-Lambda PFE300S 500S Series INSTRUCTION MANUAL

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Adjustment functions for both span and shift have been incorporated

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

CQM1-SF200/CS1W-SF200

Electronic overload relay EF19 and EF45

38 Series - Relay interface modules A

Manual Ranging MultiMeter

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Contents. Document information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

ADM1TE 5/30A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Advantium 2 Plus Alarm

User s Manual AURORA 1.2K/2.2K

38 Series - Relay interface modules A

12 Volt 30 Amp Digital Solar Charge Controller

IO-DIM6 6-Channel, Digital to Analogue Converters

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Electronic overload relay EF65, EF96 and EF146

Telefon (+45) Telefax (+45) Installation and operating manual

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Safety Manual BT50(T) Safety relay / Expansion relay

Mobile Data Power Model: MDP-25

T7560A,B,C Digital Wall Module

RC NETWORKS SALES GUIDE

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

3M Wrist Strap and Footwear Tester 740. User s Guide

Redundancy Module QUINT-DIODE/40

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

OPLC Installation Guide

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Product and functional description

Cross-beam scanning system to detect slim objects. 100 mm in

48 SERIES Relay interface modules 10 A

AutoRanging Digital MultiMeter

HM-W536 Install Guide

is then retained absolutely without interruption.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Square D Clipsal C-Bus Network Analyzer

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

User s Manual Before using the inverter, you need to read and save the safety instructions.

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

MINI MCR-SL-R-UI(-SP)

DALI RC BASIC SO. Control unit Operating instructions

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

49 Series - Relay interface modules A. Features

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Installation and safety instructions for AC/DC built-in devices

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

! WARNING. Before using product, read and understand instructions.

WD-AMX Water Detection Controllers

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Three-phase monitoring relay CM-PFE

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Emergency lighting units EM powerled

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Phase-sequence Phase-loss Relay

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Liquid Leakage Sensor Amplifier

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

650W Single Output Power Supply

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Transcription:

Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. Warning Symbols CAUTION. OPERATION TEMP RANGE 10---+60 C (100% LOAD) +70 C (60% LOAD) SEE. DO NOT MODIFY, DISASSEMBLE THE POWER SUPPLY.. INSTALLATION BY TRAINED PERSONAL ONLY. NOTICE: (1) Installing/Storage Environment 1. Store the product with ambient temperature 30 to +85 C, and relative humidity 10 to 95% (No Dewdrop). 2. Never operate the unit under over current or shorted conditions for 30 seconds and out of Input Voltage Range in specification which could result in damage or insulation failure or smoking or burning. 3. Confirm connections to input/output terminals are correct as indicated in the instruction manual. 4. Use the product where the relative humidity is 30 to 90% (No Dewdrop). 5. Avoid places where the product is subjected to direct sun light. 6. Avoid penetration of metal chips when processing mounting holes. DWG NO. : CA738-04-01/E-A APPD CHK DWG

7. Avoid places where the products is subjected to penetration of liquid, foreign substance, or corrosive gas. 8. Avoid places subject to shock or vibration. A device such as a contact breaker may be a vibration source. Set the product as far as possible from possible sources of shock or vibration. 9. If the product is used in an area with excessive electronic noise, be sure to separate the unit as far as possible from the noise sources. Precautions in Using the product: When the product is used under the circumstance or environment below, ensure adherence to limitations of the ratings and functions. Also take countermeasures for safety precautions such as fail-safe installations. 1. Under the circumstances or environment which are not described in the instruction manual. 2. For nuclear power control, railway, aircraft, vehicle, incinerator, medical equipment, entertainment equipment, safety device etc 3. For applications where death or serious property damage is possible and extensive safety precautions are required. 4. Don t recommond using input power source with large inductance, which may cause unit operate unstablely. 5. The end equipment manufacturer must provide protection to service personal against inadvertent contact with terminals. These terminals must not be user accessible. 6. Ensure power supply with over current protection (less than 24A) function. 1. Terminal Explanation 1 OK: OK signal terminal of relay A 2 +: + Signal terminal of relay A (relay A common) 3 F: F signal terminal of relay A 4 OK: OK signal terminal of relay B 5 +: + Signal terminal of relay B (relay B common) 6 F: F signal terminal of relay B 7 A+: DC input + of channel A 8 B+: DC input + of channel B 9 +V: Output terminal + -V: Ground of both input voltage and output voltage

2. Terminal Connecting Method Pay attention to the input wiring. If it is connected to wrong terminal, the unit may be damaged. Input must be off when making connections. Connect ground of input channel A, input channel B and output together to -V terminal. When connecting or removing input and output wire, do not apply stress to PCB. A B 3. Explanation of Functions and Precautions 3-1. Simplified connection block A+ B+ +V +V -V 3-2. Input Voltage Range LED LED Nominal input voltage range is 21 ~ 28VDC. Input voltage above 35VDC (continuous), or reverse output voltage more than 35VDC may cause unit damage. 3-3. Output Voltage Range Output voltage is the higher input voltage of both channels decrease 0.5VDC (output drop voltage). + F OK + F OK A B 3-4. Nominal Input Current and Maximum Output Current Nominal input current is 20A (A,B total), maximum output current is 20A. 3-5. Input Voltage Supervision Each channel is supervised. For voltages above low input voltage alarm level (19.2VDC+1%), a relay is activated closing a galvanically free contact, + to OK (Normally Open, NO). For voltages above high input voltage alarm level (30VDC+5%) a relay is activated closing a galvanically free contact, + to F. The relay also has a Normally Closed, NC contact set, eg. + to F (Fail). This voting device also is equipped with green Light Emitting Diodes, lighting simultaneously with the respective activated relay. LED lights when input voltage within input voltage range, goes off when input voltage below low input voltage alarm level or above high input voltage alarm level. 3-6. Supervision Built-in Relay Specification Maximum relay contacts ratings is 28VDC, 1A. Minimum relay contacts ratings is DC 1mA (5mA recommended). The relay outputs need maximum 4A over current protection.

3-7. Operation Schematic Fig. A Dual Input Mode 3-9. Withstand Voltage This model is designed to withstand 500VAC between input, output and FG (Chassis), input, output and relay contact, relay contact and FG each for 1 minute. When testing withstand voltage, set current limit of the withstand voltage test equipment to 100mA. The applied voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down. When timer is used, the power supply may be damaged by high impulse voltage at timer switch on and off. (Ref. to Fig C) 1 Input,Output ~ FG(Chassis) -- 500VAC 100mΑ 2 Input,Output ~ Relay Contact --500VAC 100mΑ 3 Relay Contact ~ FG(Chassis) -- 500VAC 100mΑ Note: please use the same model power supplies (#1 and #2) in conformance with UL508 safety requirement. Fig. C Test Method Fig. B Singal Input Mode 3-8. Isolation Test Isolation resistance shall be more than 10MΩ at 500VDC for safety operation, voltage setting of DC isolation tester must be done before the test. Ensure that it is fully discharged after the test. (Ref. to Fig C) 1 Input,Output ~ FG(Chassis) -- 500VDC 10MΩ 2 Input,Output ~ Relay Contact --500VDC 10MΩ 3 Relay Contact ~ FG(Chassis) -- 500VDC 10MΩ

LAMBDA 4. Mounting Directions 4-1. Output Derating according to the Mounting Directions Recommended standard mounting method is ( A ). Please do not use installation method ( B ). Refer to the derating below. Do not exceed the load deratings. Normal mounting (A) Air Flow 5. Wiring Method The output load line and input line shall be separated and twisted to improve noise sensitivity. Use all lines as thick and short as possible to make lower impedance. Noise can be eliminated by attaching a capacitor to the load terminals. Recommened screw torque is 0.49N.m (5kg.cm). Recommened wire type: solid and stranded single wire, AWG 12~20 (wire strip length: 7mm). Below appropriate over current protection is required when make connection. 20mm minimum 20mm minimum Over current protection rating is based on the smallest wire connection to either the input or output Wire size (AWG) Wire size (mm 2 ) Maximum over current protection rating (A) 20 0.52 5 18 0.82 7 16 1.3 10 14 2.1 20 12 3.3 25 Back Down Mounting (B) 6-1. Power supply mounting on DIN RAIL (TS35 or equivalent) (1) Tilt the unit slightly rearwards, fit the unit over top hat rail. Output Derating (100% load = 20A) Vin=21~28VDC 100 80 Load (%) 60 40 20 0-10 0 10 20 30 40 50 60 70 Ambient Temperature ( C)

(4) In order to tighten the unit mounting, the Din rail stopper attached on both sides of the unit is recommended. 6-2. Power supply removal from DIN RAIL (1) Switch main power off and disconnect your system from the supply network. Push the button on the rear upper edge of the unit or move the removal hole on the rear down edge downwards by screw driver. Gently lift lower front edge of the unit (tipping) and remove it. (2) Slide it downward until it hits the stop. (3) Press against the bottom front side for locking. Shake the unit slightly to check the locking action. 7.Before concluding that the unit is at fault... Before concluding that the unit is at fault, make the following checks. Check if the rated input voltage is connected. Check if the wiring of input and output is correct. Check if the wire material is not too thin. Check if the output current and output wattage do not over specification. 8. Notes 1 ) Meet EN50178 over voltage Category I. 2 ) Radio Interference Suppression Test is not performed. 9. Repair In case of damage or repair of this product, please return to our service center or factory.