PHYSICAL, CHEMICAL AND BIOLOGICAL ASPECTS OF WATER -An Overview of Fouling - T. Reg. Bott



Similar documents
SOLAR WATER PURIFICATION WITH THE HELP OF CSP TECHNOLOGY

Water Treatment and Reverse Osmosis Systems

Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.

Best Practice in Boiler Water Treatment

A Guide to Trouble-Free Cooling Towers

Wastewater Reuse. Typical treated wastewater is:

THE USE OF OZONE IN COOLING TOWERS

Troubleshooting Your RO

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

COOLING WATER MANAGEMENT

The soot and scale problems

Selecting TEMA Type Heat Exchangers

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

ROSS Technology Removal of Oil, Solids and Scale Formers

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Development of Advanced Wastewater Treatment and Reclamation System

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

Ozone in Cooling Towers : Hygiene for us

cmn_lecture.2 CAD OF DOUBLE PIPE HEAT EXCHANGERS

WASTEWATER TREATMENT

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

Remediation of Water-Based Drilling Fluids and Cleaning of Cuttings

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Scaletec Plus. Descaling Overview, Guidelines, Cleanup Tips, And Question & Answers

Cooling Towers: Understanding Key Components of Cooling Towers and How to Improve Water Efficiency

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

Heating Water by Direct Steam Injection

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Heat Transport Study of the Laminar Heat Pipe Heat Exchanger

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

Water Specialists for the Petrochemical Sector. ovivowater.com. creating value in water through innovation, creativity and expertise

The Second Law of Thermodynamics

Evaluation of Alternatives to Domestic Ion Exchange Water Softeners. Mara Wiest Dr. Peter Fox Dr. Lee Wontae, HDR Tim Thomure, HDR

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

How Ground/Water Source Heat Pumps Work

105 Adopted:

REHABILITATION METHOD FOR INCREASING FLOW VELOCITY AND REDUCING SEDIMENTATION

Accurate Air Flow Measurement in Electronics Cooling

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

جامعة البلقاء التطبيقية

GUIDELINES FOR LEACHATE CONTROL

TABLE OF CONTENT

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

More inside :: Tackle even the toughest water treatment piping challenges with

Chapter 2 Basis of design and materials

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

PLANT LOCATION AND LAYOUT

Chemistry at Work. How Chemistry is used in the Water Service

ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Unsteady State Relief Valve Evaluation. External Pool Fire Scenario

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

Mechanical shaft seal types and sealing systems

Environmentally Friendly Solutions for Industry MEXEL 432 CASE STUDY - GEOTHERMAL POWER GENERATION

13.1 The Nature of Gases. What is Kinetic Theory? Kinetic Theory and a Model for Gases. Chapter 13: States of Matter. Principles of Kinetic Theory

Azeri, Chirag & Gunashli Full Field Development Phase 3 Environmental & Socio-economic Impact Assessment. A10.1 Introduction...

Department of Environmental Engineering

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

HUBER Vacuum Rotation Membrane VRM Bioreactor

Which of the following can be determined based on this model? The atmosphere is the only reservoir on Earth that can store carbon in any form. A.

Phosphorus Removal. Wastewater Treatment

KINETIC MOLECULAR THEORY OF MATTER

2014 Service Technician Training Program Closed Loop Systems

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

WASTEWATER TREATMENT OBJECTIVES

RO / NF Cleaning Guidelines

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Case Study: Optimizing Scale Inhibition Costs in Reverse Osmosis Desalination Plants

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

AIR CONDITIONING TECHNOLOGY

steam centre of excellence Steam Boiler System Optimization

PTFE Slide Bearings 04/10 149

North American Stainless

Steam System Best Practices Condensate System Piping

Removing Solids with Automatic Self-Cleaning Filters

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

Pressure drop in pipes...

Case History Report The Dolphin Nonchemical Device Boilers and Cooling Tower

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Chapter 12 - Liquids and Solids

Elucidation of membrane biofouling processes using bioassays for assessing the microbial growth potential of feed water

Optimization of Cleaning-In- Place (CIP) processes in bottled water industry

BRAZED PLATE INSTALLATION MANUAL

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Section 15.2 Water Purification

Energy Efficient Operations and Maintenance Strategies for Boilers

Optimize Pipeline Hydraulics with Multiphase Flow Modeling

The Par-Gel Filter Water Removal Filter Elements

Transcription:

AN OVERVIEW OF FOULING T. Reg. Bott School of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK Keywords : Antiscalant, Biocide, Equilibrium, Cooling tower, Mitigation, Precursor, Nutrient Contents 1. Introduction 2. Categories of Fouling Glossary Bibliography and Suggestions for further study Summary Fouling, the unwanted accumulation of generally solid material on heat exchangers interferes with efficient operation. Foulants vary widely in character ranging from deposits of previously suspended particulate matter, previously soluable salts, living matter in the form of micro or macroorganisms or products of corrosion. The presence of the deposit increases the pressure loss through the exchanger and restricts heat transfer. Unless the problem is controlled, severe malfunction of the equipment may be experienced and the associated additional costs may be high, including lost production, extra energy and maintenance costs. Techniques employed for control may be physical or chemical. 1. Introduction The term "fouling" usually refers to the accumulation of unwanted, generally solid material on surfaces. In many industrial situations these deposits interfere with the operation of the particular process plant in which the fouling occurs. In some operations the deposit may be of benefit. In the biological treatment of waste water, for instance, where the accumulation of biofilms on the surfaces of an inert medium is essential for effective treatment, the establishment of the "fouling" layer is actively encouraged. In most industrial processes however, the presence of deposits represents a problem ranging from a simple nuisance to a serious operating difficulty. Deposit formation can occur from a fluid, whether flowing or stagnant, dependent on the conditions prevailing in the system. The possibility of fouling therefore, has to be recognized and suitable mitigation opportunities taken to alleviate any detrimental effect that may result, in order to maintain satisfactory performance. Fouling is in general, related to the processing of fluids either liquid or gas, and the origins of the associated foulant (or foulants) are diverse. Suspended matter, dissolved solids, breakdown of the fluid being processed, chemical reactions, the presence of living entities such as bacteria, fungi or algae on the microscale, or much larger creatures such as mussels and barnacles, may, depending on the system, contribute to the growth of deposits on surfaces. The deposit itself will often consist of a complex

heterogeneous mass, difficult to define in a comprehensive way. The character of the deposit may change as the accumulation process continues, so that the outer layers are quite different from those directly attached to the surface. In water systems fouling may result from the precipitation of dissolved solids (scaling), deposition of suspended solids, corrosion of metal surfaces or the accumulation of micro or macroorganisms. There may be some synergism between two or more fouling effects, for instance corrosion may be encouraged below biofilms, where the ph level is more aggressive, due to the biological activity, than in the bulk. Precipitation of dissolved salts may occur in evaporators in desalination plant, that restricts heat transfer, reducing evaporation rates, with a general detrimental effect on thermal efficiency. Corrosion can occur in almost any part of a process plant, particularly in equipment fabricated from mild steel, due to the presence of aggressive components in the water. The resultant corrosion layers may restrict flow through pipes and valves and give rise to particulate matter that is carried forward in the water flow. Suspended particulate solids, either corrosion products or material introduced with the water feed, are likely to accumulate in stagnant regions or where velocities are low. Eventually this may present severe restrictions on flow and may even block valves. The performance of reverse osmosis membranes in desalination plant may be affected by the presence of deposits of particles originally suspended in the water. Biofouling can occur in almost any location in a water circuit having conditions that sustain primative life, e.g. availability of nutrients, oxygen, temperatures in the region of 3040 C and ph around 7. The performance of cooling towers, water coolers, e.g. steam condensers, is likely to be affected by reduced heat transfer. Flow restrictions in ducts and pipe lines will also be apparent. Membrane surfaces in reverse osmosis units may provide suitable habitat for microorganisms so that the efficiency of the process is adversely affected. Figure 1. An idealized representation of deposit development with time. The thickness of a foulant layer on a surface in a flowing system will increase over a period of time. The rate of growth will depend on the prevailing conditions and in particular the magnitude of the velocity in flowing systems. An ideal curve for the development of a deposit with time is shown in Figure 1. Essentially it consists of three

regions: 1. A period of time when little or no deposition occurs (labeled A in the diagram). Often this region is referred to as the "initiation" or "conditioning" time. It ranges from minutes to months. In many examples of fouling the conditioning of the surface is not fully understood, but it would seem that in most examples of fouling surface effects are necessary before fouling can commence at a measurable rate. In biofouling, for instance, it is understood that an adsorbed conditioning layer of organic macromolecules on the surface, is required before microorganisms can attach. The function of this adsorbed layer is not clear but it may well be that in natural conditions, the quantity of organic breakdown products is large compared with the concentration of microorganisms, and therefore these macromolecules are first to attach. Under these circumstances, it would be expected that bacteria for instance, will have adapted so that they require the presence of this conditioning layer before attachment is possible. It is entirely possible also that this organic conditioning layer represents a nutrient source, which further encourages the microorganisms to the surface. Once deposition begins, provided the foulant or precursors are present in sufficient quantity, the foulant layers may be laid down quite rapidly, in relative terms (see section of the curve labeled B in Figure 1). After a period of time the rate of growth of accumulation slows down and may even cease altogether (region C in Figure 1). The usual explanation for this observation is as follows: The laying down of the deposit is a dynamic process so that removal of foulant from the surface and deposition are occurring at the same time. In the initial stages, the rate of deposition far exceeds the rate of removal, but as the deposit grows the rate of removal increases until the plateau, or equilibrium, condition is reached and the two rates are the same, thereby giving a constant thickness. This is brought about by the fact that as the flow area reduces due to the presence of the deposit, for a given flow rate, the velocity increases. As a result the shear forces acting on the deposit surface increase and the rate of removal increases. It has to be stressed that this is an ideal representation of the fouling process (see Figure 1), many variations may be observed in practice. Some fouling processes may show a straight line relationship with time (this implies a tenacious deposit), while others show a falling rate but never reaching a constant deposit thickness. Under static conditions, such as might occur in a tank, the presence of a deposit is more likely to represent a contamination risk to the fluid as it is used from the tank, rather than interference with operations associated with fluid movement. Where a fluid is flowing in pipes and ducts, the effect of deposits is felt in terms of increased pressure loss through the system. There are a number of reasons for this effect, but principally it results from the reduction of flow area due to the presence of the deposit. As the flow area becomes restricted for a given volumetric flow rate, the velocity is increased. As the pressure loss is proportional to the square of velocity, a small reduction in cross sectional area can represent a relatively large increase in pressure required to drive the fluid through the system. As an example, if a deposit of 1 mm thickness resides on the

inner surface of a 20 mm I.D. pipe the flow area is reduced by a factor of 18 2 /20 2 = 0.81. If a fluid flows at 1 m s 1 in the clean pipe, in order to give the same volumetric flow in the fouled pipe the velocity has to increase to 1.23 m s 1, i.e. the pressure loss is increased by a factor of (1.23) 2 = 1.51 or over 50 per cent. Reduction in flow area is not the only result of the presence of deposit on the pipe surface that affects pressure loss. In general, the surface topography of deposits is rough. An example is given in Figure 2 which shows the rippled surface of a deposit formed by the precipitation of silica from flowing geothermal water. The effect of increased roughness is to increase frictional losses still further, with an accompanying additional pressure loss through the system. It is very possible that the frictional pressure loss could be more than doubled as a result. Figure 2. A rippled silica deposit on the inside of a heat exchanger tube. Apart from roughness, the energy absorbed as a result of the presence of the foulant, can be increased by other deposit characteristics. For instance, a biofilm which in general terms is a matrix of microorganisms, extracellular organic material, debris and water filled interstices, is flexible, so that under the influence of flowing water, it deforms thereby absorbing energy from the system. The increased energy demand in a flowing system can be considerable, but there are further energy implications where heat exchangers are subject to deposit accumulation. The purpose of a heat exchanger is to transfer heat effectively between two streams. TO ACCESS ALL THE 11 PAGES OF THIS CHAPTER, Visit: http://www.desware.net/deswaresampleallchapter.aspx

Bibliography and Suggestions for further study Bott T R (1990) Fouling Notebook. Rugby: Institution of Chemical Engineers. Bott T R (1995) Fouling of Heat Exchangers. Amsterdam: Elsevier. Charackerlis W G and Marshall K C (1990) Biofilms. New York: John Wiley and Sons Inc. D. Feng, J.S.J. van Deventer, C. Aldrich (2006),Ultrasonic defouling of reverse osmosis membranes used to treat wastewater effluents, Separation and Purification Technology, Volume 50, Issue 3, 15, 318323 F. A. Abd El Aleem, K. A. AlSugair and M. I. Alahmad (1998),Biofouling problems in membrane processes for water desalination and reuse in Saudi Arabia,International Biodeterioration & Biodegradation Volume 41, Issue 1, 1923 Glater, J.(1998), The History of Reverse Osmosis Membrane Development, Desalination, 117, 297309 Hewitt G F, Shires G L and Bott T R (1994) Process Heat Transfer. Boca Raton: CRC Press. J.S.Vrouwenvelder C. Picioreanu, J.C. Kruithof, M.C.M. van Loosdrecht(2010),Biofouling in spiral wound membrane systems: Threedimensional CFD model based evaluation of experimental data,journal of Membrane Science,346, 71 85 Melo L F, Bott T R, Fletcher M and Capdeville B (eds) (1992) Biofilms Science and Technology. Dordrecht: Kluwer Academic Publishers. WenYi Shih, K. Albrecht, J. Glater and Y. Cohen((2004)), A Dual Probe Approach for Evaluation of Gypsum Crystallization in Response to Antiscalant Treatment, Desalination, 169 (3), 213221. WooNyoung Lee, InSoung Chang, ByungKook Hwang, PyungKyu Park, ChungHak Lee, Xia Huang (2007), Changes in biofilm architecture with addition of membrane fouling reducer in a membrane bioreactor,process Biochemistry 42, 655 661