Combustible Dust Booklet



Similar documents
Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

AIHA Professional Development Conference by Daniel Brechko, Managing Consultant

Explosion Prevention

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

Combustible Dust: - The Basics You Need to Know. Presented by: Mary Ann Heaney, CIH, CSP ohsm, llc.

Is This Combustible Dust?

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

Combustible Dust Ensuring Safety and Compliance. Brian Edwards, PE Conversion Technology Inc. ENVIRONMENTAL & SAFETY CONSULTING ENGINEERS

Combustible Dust. Overview

Assessing the Potential for a Dust Explosion and Navigating the Current Regulatory Environment

COMBUSTIBLE DUST EXPLOSIONS

Use of Combustible Dust Risk Assessments in the Agricultural and Food Processing Industries. by Douglas Moilanen

Combustible Dust. The Basics. Presented by: Mary Ann Heaney, CIH, CSP ohsm, llc.

Combustible dust. How to use this guide. Combustible Dust

Electrical Classification

COMBUSTIBLE DUST in the WOOD PRODUCTS INDUSTRY

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

WEEKLY SAFETY MEETING All Euramax Subsidiaries COMBUSTIBLE DUST. Safety Meeting Contents. Meeting Notice. Leaders Guide.

The Status of Combustible Dust Regulation

Illinois Manufacturers Best Practices January 2016 Webinar

Combustible Dust CAN HURT YOU

Anew combustible dust standard from the National. Get ready for NFPA 652: The new combustible dust standard

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

MINIMUM IGNITION TEMPERATURES OF FOOD DUST CLOUDS DETERMINATED BY PLANNED EXPERIMENT

A strategic guide to characterisation & understanding

Dust Explosion Fundamentals: Ignition Criteria and Pressure Development

The American Iron and Steel Institute (AISI) appreciates the opportunity to submit these

99/92/EC (ATEX 137) USE

Combustible Dust Fire and Explosion Protection:

The Minimum Ignition Energy of Coal Dust in an Oxygen Enriched Atmosphere

Uline NFPA. SECTION 1 : CHEMICAL PRODUCT AND COMPANY IDENTIFICATION MSDS Name: Collapsible Bulk Containers

Combustible Dust Basics

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Group A/B Dust Explosion Classification Chilworth Hazard and Risk Profile (CHARP) - Standard package of tests

NFPA Combustible Dust Compliance and the Industrial Ventilation System

Ethanol Vehicle and Infrastructure Codes and Standards Citations

EXPLOSION SAFETY DOCUMENT FOR THE ATEX 137 DIRECTIVE NEW NAME FOR A FIRE AND EXPLOSION HAZARD ASSESSMENT?

INTERNATIONAL STANDARD

During Various Aluminum Fabricating Operations

Making sense of Intrinsic Safety and Intrinsically Safe Tools

12.85 Enforcement and Consultation Guidance for Combustible Dust Hazards December 30, 2008

Safety Data Sheet for Whole Grain

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Controlling fire and explosion risks in the workplace

SAFE TRANSFER OF POWDERS INTO FLAMMABLE LIQUIDS David E. Kaelin Sr., Senior Process Safety Specialist

To provide guidelines for the safe inspection of potential combustible worksites and for the safe collection and shipment of combustible dust

How to be Sure Your Dust Collector Design and Installation are NFPA Compliant. Presented by: Jeff Kice Kice Industries, Inc.

Combustible Dust Hazards

Hazard Communication Guidance for. Combustible Dusts

Combustible Dust in the Workplace An overview of its recognition, evaluation, and control

Process Safety Training (Shanghai)

TR2. Recommendations for storage and. handling of aluminum powders and paste

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

PARALOID KM-1 Acrylic Impact Modifier

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Minimum Ignition Temperature of Hybrid Mixtures Of Burnable Dusts and Gases

Presented by: Rich Perry Marsh Risk Consulting

Flammable and Combustible Liquids. Slide 1 (of 23)

INVESTIGATION REPORT COMBUSTIBLE DUST HAZARD STUDY KEY ISSUES: U.S. CHEMICAL S AFETY AND H AZARD INVESTIGATION BOARD FEDERAL REGULATIONS

ISMA StuvEx PAGG IExT. Product Guide

HOT WORK PERMIT PROCEDURES

Guidelines for Use and Handling of HFO-1234yf

REVISION NO : 3 August 2010

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

MATERIAL SAFETY DATA SHEET High Pressure Laminate Fire Retardant

Flammable Liquids 29 CFR

Dust Collector Fire and Explosion Highlights Need for Combustible Dust Considerations In System Designs

MATERIAL SAFETY DATA SHEET

Flammable Liquids Storage

SOLVENT CLEANER MSDS Page 1 of 5 SAFETY DATA SHEET. (To comply with OSHA s Hazard Communication Standard 29CFR /ANSI z400.

SAFETY DATA SHEET. Trade name: Master Clear Seal-5 Revised: 5/29/2015

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

Safety Data Sheet Avesta Neutralization Agent 502

The Globally Harmonized System and OSHA Hazard Communication Revision

An Introduction to ATEX -

Designing your dust collection system to meet. triangle: fuel (combustible dust), an ignition source, and

The Effect of Coating Process Conditions and Coating Formula Type on the Quantity and Location of Water in Film Coated Tablets

Comparison Between ATEX 94/9/EC. and NFPA 85

Combustible Dust... Elements of Dust Hazard Assessment

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Material Safety Data Sheet

Material Safety Data Sheet

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

HOT WORK PERMIT PROGRAM TRAINING. John Braun

Compressed Gas Cylinder Storage and Handling Guide

Basics of Explosion Protection

MRC Polymers Inc. Material Safety Data Sheet. Product Name: Naxaloy PC/ABS blends Product Series: 750, 760, 770, 770A3, 770A4, 770A5, 770A6, 770L, 772

Transcription:

Introduction In general, over 70% of organic dusts are explosible if given an adequate ignition source and appropriate dust/air concentration. Unless the material is combustible and finely divided (generally less than 420 microns/40 mesh) it cannot sustain flame propagation in a suspended dust/air atmosphere. The earliest explosions involving industries handling powder materials, like the coal industry and flour mills, were attributed to a flammable gas, which was thought to be produced by the dispersed dust. It was not until the latter part of the nineteenth century that it was realized that coal dust could ignite and explode in the absence of a flammable gas, or that flour dust alone was responsible for the increasing number of explosions in mills. Recent statistics from the USA and some European countries indicate that dust fires and explosions are not uncommon in industries handling or processing bulk solids and powders. So which industries are at risk? Materials in powder form are used in a wide variety of industries, including pharmaceutical, chemical, plastics and food, among others. Many powders handled by these industries will explode if dispersed in the presence of an ignition source. The purpose of this booklet is to provide necessary information to Colorcon customers regarding our products. Dust Fire or Explosion Hazards A chemical dust deflagration occurs when the right concentration of finely divided chemical dust suspended in air is exposed to a sufficient source of ignition to cause ignition (combustion) of the dust. If the deflagration is in a confined area, an explosion potential exists. These materials can also cause other fires. Combustible dust is often either organic or metal dust that is finely ground into very small particles. The actual quantity of dust that may accumulate in an affected area may vary, depending upon air movement, particle size, or any number of other factors. 1 1 From OSHA Combustible Dust National Emphasis Program, CPL 03-00-008 Page 1 of 6 September 2015

Dust Hazard Properties Minimum Dust Cloud Ignition Energy or Powder Minimum Ignition Energy (MIE) This value is a measure of the ease of ignition of a suspended dust cloud by low energy ignition sources, such as electrostatic sparks. Materials that have low MIE values are more likely to ignite from low energy electrostatic ignition sources. Such ignition sources include electrostatic charges created when electrically resistant powders are transferred through equipment and the charges built up on personnel. MIEs less than 100 mj are considered to represent a hazard of ignition from weak electrostatic sources. The charge generated on personnel is of the order of 20-30 mj. Figure 1 Significance of Minimum Ignition Energy 2 For materials having a MIE of less than 1,000 mj, and a Minimum Ignition Temperature <500 C, there is a possibility of ignition by sparks caused by friction/impact of steel objects. 2 From NFPA 77, FIGURE 5.3.1 Approximate Energies of Types of Discharges Compared with Minimum Ignition Energies (MIEs) of Typical Combustible Materials. (Adapted from H. L. Walmsley, Avoidance of Electrostatic Hazards in the Petroleum Industry, p. 26.) Page 2 of 6 September 2015

Minimum Dust Layer Ignition Temperature, MITlayer or LIT ( C) This temperature is the point at which a deposited dust layer will ignite if exposed to a hot surface. Typical values for organic dusts are 300 to 450 C. This property is used when specifying the maximum surface temperature for devices and equipment surfaces, such as hot air dryers, that could be exposed to an ignitable dust layer and in the specification of electrical device surface temperatures for use in hazardous locations. Minimum Explosible Concentration (MEC) The minimum explosible concentration (MEC) is the minimum concentration of dispersed dust capable of being ignited and supporting flame propagation. MEC data can be used to specify ventilation and extraction as a means of dust explosion prevention. NFPA 69 3 recommends that when control of the flammable atmosphere is used as a basis of safety, ventilation should be sufficient to maintain the average fuel concentration to less than 25 percent of the lower flammable limit (LFL). Thus, ventilation should be sufficient to limit the average concentration of dispersed dust to less than 25 percent of the MEC, since the MEC can be thought of as the LFL for an explosible dust. Typical MECs for many combustible dusts lie in the 20 to 120 gm/m 3 range. The use of ventilation is generally not recommended as a sole basis of safety for an operation; however, since the evolution of localized dust concentrations exceeding the MEC may be inevitable even when adequate ventilation is provided. Maximum Pressure, PMAX This is the maximum closed system pressure caused by a confined fuel(dust)/air explosion. Typical deflagration explosions such as dust/air explosions will produce closed system pressures of about 8 to 10 barg (116 to 145 psig). This property can be used to specify containment design criteria for new equipment as a basis of safety. 3 NFPA 69 Standard on Explosion Prevention Systems; National Fire Protection Association (NFPA); Page 3 of 6 September 2015

Dust Explosion Class and Deflagration Index, KSt One aspect of explosion risk of dusts is the level of consequence of an uncontrolled confined explosion. The Deflagration Index, K St is calculated from the maximum rate of pressure rise and the size of the test sphere. This property is a scaling factor used to predict confined explosion behavior in different size enclosures based on a fixed test enclosure, usually 20-liters in accordance with ASTM E-1226. This index has application in the design of explosion protection systems such as vents or suppression systems and is an indicator of the level of hazard presented by the material. Dusts are classified based on the value of the Deflagration Index, as described in the next paragraph. Four classes of dust explosion hazard are used for rating dusts, ST-0, ST-1, ST-2 and ST-3. A range of deflagration index values as shown below defines each class. Hazard Class Dust Hazard Classes Deflagration Index, K ST Range Bar-m/sec Descriptive Phrase ST-0 0 No Explosion ST-1 Less Than 200 Weak Explosion ST-2 200-300 Strong Explosion ST-3 Greater Than 300 Very Strong Explosion Explosible dusts with K ST values below 200 bar-m/sec are classified as ST-1 dusts (weak explosive dusts). This type of material, should ignition occur in a confined space, will produce a relatively weak explosion. Even a weak explosion can have extreme consequences and should not be taken lightly. Most dust handling equipment is not designed to survive dust explosion pressures and will fail catastrophically if exposed. Properties of Colorcon Product Lines 1. Materials on the following chart are combustible particulate solids and could explode if suspended in air in an adequate concentration and subjected to an adequate ignition source. Such events can cause significant equipment and building over-pressurization leading to damage and threat to life. Handling of this material requires special precautions. Page 4 of 6 September 2015

Product Family Explosion Class A=explosible, B=not explosible St Class Pmax (bar g) Kst (bar* m/s) Minimum ignition energy MIE (mj) Minimum ignition Temperature of a dust cloud, MIT (deg C) Minimum ignition Temperature of a dust layer, LIT (deg C) Acryl-EZE A 1 as high as 200 as low as 100 as low as 480 as low as 275 D&C Red #7/Lithiol Rubin CL 47%-53% A 2 as high as 8.2 as high as 201 as low as 100 25/30 Sugar Spheres A 1 as high as 8.0 as high as 170 as low as 10 as low as 400 Starch 1500 Starcap A 1 as high as 7.5 as high as 145 as low as 500 as low as 400 Opadry A 1 as high as 9.0 as high as 200 as low as 100 as low as 360 as low as 275 Opadry Enteric A 1 as high as 200 as low as 10 as low as 420 as low as 275 Opadry II A 1 as high as 6.0 as high as 50 as low as 100 as low as 360 as low as 150 Opadry NS A 1 as high as 7.0 as high as 200 as low as 500 as low as 380 as low as 270 Opalux A 1 as high as 7.0 as high as 100 Opalux Dry A 1 as high as 6.5 as high as 92 as low as 1000 as low as 400 Pigment Blend A 1 as high as 200 as low as 100 as low as 275 FD&C Lake B 0 Phthalavin PVAP (Jet-Milled) A 2 as high as 8.5 as high as 230 as low as 25 Phthalavin PVAP A 1 as high as 7.5 as high as 170 as low as 25 as low as 420 as low as 400 Rapid Subcoat A 1 as high as 6.1 as high as 65 as low as 1000 as low as 400 POLYOX A 1 182 under 10 METHOCEL A 1 8.9 88 as low as 29 360 ETHOCEL A 1 8 as high as 200 as low as 3 380 Sureteric A 2 as high as 7.5 as high as 220 as low as 10 as low as 400 Page 5 of 6 September 2015

Dust fire and explosion properties vary significantly from material to material and are strongly dependent on a powder s moisture content, particle size, and particle shape. The finest particles will exhibit greater ignition sensitivity and explosion violence when compared to larger ones. Also, the presence of flammable vapors or gases in a dust laden atmosphere can dramatically increase the severity and ignition sensitivity of a given atmosphere. This data represents only particular samples tested. This data may not represent the dust explosion hazards associated with fugitive dust deposits because particle size segregation often occurs as dusts are lofted onto elevated surfaces. Please consult with OSHA regulations, applicable regional regulations, and National Fire Protection Association (NFPA) consensus codes and standards for the processing and handling of combustible particulate solids. Specific codes, standards, and reference sources considered are listed below: 1. NFPA 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids. 2. NFPA 61 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities 3. NFPA 77 Recommended Practice on Static Electricity 4. NFPA 68 Standard on Explosion Protection by Deflagration Venting 5. NFPA 69 Standard on Explosion Prevention Systems 6. NFPA 70 National Electrical Code 7. NFPA 499 Recommended Practice for the Classification of Combustible Dusts and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas. 8. DSEAR-Dangerous Substances and Explosive Atmospheres Regulations, UK 9. EU Directive 99/92/EC (ATEX 137 Directive) 10. OSHA Combustible Dust National Emphasis Program, CPL 03-00-008 11. Dust Explosions in the Process Industries, Rolf Eckhoff 12. Electrostatic Hazards in Powder Handling, Martin Glor The information contained herein, to the best of our knowledge is true and accurate. Any recommendations or suggestions are made without warranty or guarantee, since the conditions of use are beyond our control. Any information contained herein is intended as a recommendation for use of our products so as not to infringe on any patent. 2010 Colorcon, Inc. The information contained in this document is proprietary to Colorcon, Inc. and may not be used or disseminated inappropriately. Global Headquarters Colorcon 275 Ruth Road, Harleysville, PA 19438 Tel: +1 215.256.7700 Fax: +1 215.256.7799 Website: www.colorcon.com BPSI Holdings LLC, 2010. All trademarks, except where noted, are property of BPSI Holdings LLC. Page 6 of 6 September 2015