OKI-T/3-W40 Series Adjustable Output 3-Amp DOSA-SMT DC/DC Converters



Similar documents
OKI-78SR Series Fixed Output 1.5 Amp SIP DC/DC Converters

OKY-T/3,T/5-D12 Series Adjustable Output 3 and 5-Amp DOSA-SMT DC/DC Converters

OKI-78SR Series Fixed Output 1.5 Amp SIP DC/DC Converters

OKR-T/10-W12 Series Adjustable Output 10-Amp SIP-mount DC/DC Converters

OKR-T/30-W12-C Adjustable Output 30-Amp SIP-mount DC-DC Converters

OKR-T/1.5-W12-C Adjustable Output 1.5-Amp SIP-mount DC/DC Converters

OKR-T/30-W12-1C Adjustable Output 30-Amp SIP-mount DC-DC Converters

TS-3GA (Rel10)v Telecommunication management; File Transfer (FT) Integration Reference Point (IRP); Requirements

Grant Request Form. Request Form. (For continued projects)

California Subject Examinations for Teachers

Procedures to file a request to the JPO for Patent Prosecution Highway Pilot Program between the JPO and the HPO

Delphi Series V48SH, 1/16 th Brick 35W DC/DC Power Modules: 48V in, 1.0V, 35A out

SELECTION GUIDE. Nominal Input

JAPAN PATENT OFFICE AS DESIGNATED (OR ELECTED) OFFICE CONTENTS

LDO03C/LDO06C/LDO10C

Application Note TMA Series

Request for Taxpayer Identification Number and Certification 納 税 者 番 号 および 宣 誓 の 依 頼 書

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

Local production for local consumption( 地 産 地 消 ) Worksheet 1. Task: Do you agree with this idea? Explain the reasons why you think so.

Quality of. Leadership. Quality Students of Faculty. Infrastructure

DC/DC Converter 9 to 18Vdc and 18 to 36Vdc and 36 to 75Vdc input, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

TEP 200WIR Series, Watt

Delphi Series V48SC, 1/16th Brick 100W DC/DC Power Modules: 48V in, 12V, 8.3A out

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out

Maximum Input Current Vin=18V, 100% Load A

世 界 のデブリ 関 連 規 制 の 動 向 Current situation of the international space debris mitigation standards

S24SE/S24DE series 20W Single/Dual Output DC/DC Converter

Application Guidelines for International Graduate Programs in Engineering

S24SE/S24DE series 10W Single/Dual Output DC/DC Converter

DC/DC power modules basics

Input and Output Capacitor Selection

28 Volt Input - 40 Watt

Graduate School of Engineering. Master s Program, 2016 (October entrance)

IS MAC Address Restriction Absolutely Effective?

1.5A Very L.D.O Voltage Regulator LM29150/29151/29152

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A Vin=24V ma

JF Standard for Japanese-Language Education 2010

英 語 上 級 者 への 道 ~Listen and Speak 第 4 回 ヨーロッパからの 新 しい 考 え. Script

Introducing DIGNIO and WEB DIGNIO Targeting Male Executives in Japan

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

NSPU510CS Built-in ESD Protection Device RoHS Compliant

Unwillingness to Use Social Networking Services for Autonomous Language Learning among Japanese EFL Students

Limited Ericsson Internal

Quality Risk Management as a Tool for Improving Compliance and E ciency

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

Cost Accounting 1. B r e a k e v e n A n a l y s i s. S t r a t e g y I m p l e m e n t a t i o n B a l a n c e d S c o r e c a r d s

LDS WLED Matrix Driver with Boost Converter FEATURES APPLICATION DESCRIPTION TYPICAL APPLICATION CIRCUIT

LM138 LM338 5-Amp Adjustable Regulators

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Advanced Monolithic Systems

LM1084 5A Low Dropout Positive Regulators

Document and entity information

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

NSSU100CT Pb-free Reflow Soldering Application Built-in ESD Protection Device RoHS Compliant

Special Program of Engineering Science 21 st Century. for Graduate Courses in English. Graduate School of Engineering Science, OSAKA UNIVERSITY

SPI-8001TW. Switching Regulators. Dual 1.5 A, DC/DC Step-Down Converter. SANKEN ELECTRIC CO., LTD.

LM3940 1A Low Dropout Regulator for 5V to 3.3V Conversion

Financial Modeling & Valuation Training

High Accuracy, Ultralow IQ, 1.5 A, anycap Low Dropout Regulator ADP3339

NS9L153AMT-H3 Pb-free Reflow Soldering Application Built-in ESD Protection Device RoHS Compliant

レッドハット 製 品 プライスリスト Red Hat Enterprise Linux2013 新 製 品 (ベースサブスクリプション) 更 新 :2015 年 4 22

DC-DC Converter Module

AVD75-48S1V2. Product Descriptions. Applications. 30 Watts

Cool-Power PI33xx-x0. 8 V to 36 V IN Cool-Power ZVS Buck Regulator Family. Product Description. Features & Benefits. Applications. Package Information

Series AMLDL-Z Up to 1000mA LED Driver


YAS532B MS-3R Magnetic Field Sensor Type 3R

R-78xx-0.5 INNOLINE. Features. 0.5 AMP SIP3 Single Output. Derating-Graph (Ambient Temperature) DC/DC-Converter

Melonbooks DL Howto How to register, purchase and enjoy Doujin contents that are sold in Melonbooks DL and shut-out disgusting excuse of reproduction.

High Accuracy, Ultralow IQ, 1 A, anycap Low Dropout Regulator ADP3338

Let s ask Tomoko and Kyle to the party. A. accept B. except C. invite D. include

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

1.0A LOW DROPOUT LINEAR REGULATOR

LM117 LM317A LM317 3-Terminal Adjustable Regulator

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Power Supplies 3. SDN-P DIN Rail Series

STRATO LED Drivers 70W, Single output

レッドハット 製 品 プライスリスト Red Hat Enterprise Linux 製 品 (RHEL for HPC) 更 新 :2015 年 4 22

SC728/SC729. 2A Low Vin, Very Low Ron Load Switch. POWER MANAGEMENT Features. Description. Applications. Typical Application Circuit SC728 / SC729

Panasonic AC-DC Power Supply Design Support Service

Industrial Safety and Health Act ( Act No. 57 of 1972)

28 V, 56 m, Load Switch with Programmable Current Limit and Slew Rate Control

LM2704 Micropower Step-up DC/DC Converter with 550mA Peak Current Limit

Kumiko Sakamoto, Ms., Acad, Social Science, Japan: Women and men in changing societies: Gender division of labor in rural southeast Tanzania [A2]

NF2L757DRT-V1 Pb-free Reflow Soldering Application Built-in ESD Protection Device RoHS Compliant

Data Mining for Risk Management in Hospital Information Systems

Datasheet. 2A 380KHZ 20V PWM Buck DC/DC Converter. Features

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

(2) 合 衆 国 では, 人 口 の 増 加 のほぼ 三 分 一 が 移 民 [ 移 住 ]によってもたらさている

Internal USB port kit installation

Introduction to the revised Child Care and Family Care Leave Law

VT-802 Temperature Compensated Crystal Oscillator

Preliminary Datasheet

PRELIMINARY Absolute Maximum Rating

Silvertel. Ag9800M. 1. Features. 2. Description. Miniature PoE Module. Small SMT package. IEEE802.3af compliant. Low cost

SPECIFICATION. Not recommend for new design. MS6M Power Integrated Module 7MBR15UF060 MS6M Fuji Electric Device Technology Co.,Ltd.

UL/ RAILWAYS Certified Constant Current LED Driver Wide Input and Output Voltage Range Digital PWM and Analogue Voltage Dimming

AVD120-48S12. Product Descriptions. Applications. 120 Watts

Transcription:

www.murata-ps.com OKI-T/3-W40 Series Typical unit FEATURES Non-isolated SMT POL DC/DC power module 16-40Vdc input voltage range Programmable output voltage from 0.7525-5.5Vdc 3 Amp output current models Drives 1000 μf ceramic capacitive loads High power conversion effi ciency 86% at 5 Vout Outstanding thermal derating performance Over temperature and over current protection On/Off control UL/EN/IEC 60950-1 safety, 2nd Edition Industry-standard (DOSA) surface-mount package RoHS-6 hazardous substance compliance PRODUCT OVERVIEW The OKI-T/3 series are non-isolated Point-of- Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifi cations (www.dosapower. com). Applications include powering CPU s, industrial 24V transducers and POS terminals. The wide input range is 16 to 40 Volts DC. The maximum output current is 3 Amps. Based on fi xed-frequency synchronous buck converter switching topology, the high power conversion effi cient Point of Load (POL) module features programmable output voltage and On/Off control. These converters also include under voltage lock out (UVLO), output short circuit protection, overcurrent and over temperature protections. These units are designed to meet all standard UL/EN/IEC 60950-1 safety certifications (2nd Edition) and RoHS-6 hazardous substance compliance. +Vin Connection Diagram +Vout F1 On/Off Control Controller External DC Power Source Open = On Closed = Off (Positive On/Off) Reference and Error Amplifier Trim Common Figure 1. OKI-T/3 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See specifi cations. Common For full details go to www.murata-ps.com/rohs MDC_OKI-T/3-W40 Series.A08 Page 1 of 13

Performance Specifications Summary and Ordering Guide ORDERING GUIDE Root Model ➁ VOUT (Volts) ➅ IOUT (Amps max) Power (Watts) Output Input Package, C72 R/N (mvp-p) ➃ Regulation (Max.) IIN, IIN, Efficiency VIN Nom. Range no load full load Max. Line Load (Volts) (Volts) ➅ (ma) ➄ (Amps) Min. Typ. Case C72 ➀ Pinout OKI-T/3-W40N-C 0.7525-5.5 3 15 20 ±0.2% ±0.25% 24 16-40 40 0.71 86.5% 88% 0.82 x 0.47 x 0.34 (20.8 x 11.9 x 8.5) P78 OKI-T/3-W40P-C 0.7525-5.5 3 15 20 ±0.2% ±0.25% 24 16-40 40 0.71 86.5% 88% 0.82 x 0.47 x 0.34 (20.8 x 11.9 x 8.5) P78 ➀ Dimensions are in inches (mm). ➁ These are partial model numbers. Please refer to the part number structure for complete ordering part numbers. ➂ All specifications are at nominal line voltage, Vout=nominal (5V for W40 models) and full load, +25 C. unless otherwise noted. Output capacitors are 1 μf ceramic and 10 μf electrolytic in parallel. Input cap is 22 μf. See detailed specifications. I/O caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE ➃ Ripple/Noise is shown at Vout = 1V. ➄ No load input current is shown at Vout = 0.75V. ➅ For Vout = 1V, Vin 32V. For Vout = 0.75V, Vin 24V. OK I - T / 3 - W40 N - C Okami Non-isolated PoL Surface Mount Trimmable Output Voltage Range 0.7525-5.5V Maximum Rated Output Current in Amps Input Voltage Range 16-40V RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS exemption 7b lead in solder) On/Off Logic P = Positive Logic N = Negative Logic Note: Some model number combinations may not be available. Contact Murata Power Solutions for availability. Product Label Because of the small size of these products, the product label contains a character-reduced code to indicate the model number and manufacturing date code. Not all items on the label are always used. Please note that the label differs from the product photograph on page 1. Here is the layout of the label: Model Number OKI-T/3-W40N-C OKI-T/3-W40P-C Product Code I00103 I01103 The manufacturing date code is four characters: Mfg. date code XXXXXX YMDX Rev. Product code Revision level Figure 2. Label Artwork Layout The label contains three rows of information: First character Last digit of manufacturing year, example 2009 Second character Month code (1 through 9 and O through D) Third character Day code (1 through 9 = 1 to 9, 10 = O and 11 through 31 = A through Z) Fourth character Manufacturing information First row Murata Power Solutions logo Second row Model number product code (see table) Third row Manufacturing date code and revision level MDC_OKI-T/3-W40 Series.A08 Page 2 of 13

Performance and Functional Specifications See Note 1 Input Input Voltage Range See Ordering Guide and Note 7. Isolation Start-Up Voltage Not isolated 15 V Undervoltage Shutdown (see Note 15) 14 V min., 15.5V max. Overvoltage Shutdown None Refl ected (Back) Ripple Current (Note 2) 20 ma pk-pk Internal Input Filter Type Capacitive Recommended External Fuse 1.2A fast blow Reverse Polarity Protection None. Install external fuse. Input Current: Full Load Conditions See Ordering Guide Inrush Transient 0.4 A2Sec. Shutdown Mode (Off, UV, OT) 5 ma Output in Short Circuit 60 ma Low Line (Vin=Vmin) 1.03A. Remote On/Off Control (Note 5) Negative Logic ( N model suffi x) ON = -0.3V to +1.2V OFF = (Vin -2.5V) to 40V or open Current 1 ma max. Positive Logic ( P model suffi x) ON = Open pin (internally pulled up) or = (Vin -2.5V) to 40V or open OFF = -0.3V to +1.2V Current 1 ma max. Output Output Power 15W max. Minimum Loading No minimum load Accuracy (50% load, untrimmed) ±2 % of Vnominal Voltage Output Range (Note 13) See Ordering Guide Overvoltage Protection (Note 16) None Temperature Coeffi cient ±0.02% per C of Vout range Ripple/Noise (20 MHz bandwidth) See Ordering Guide and note 8 Line/Load Regulation See Ordering Guide and note 10 Effi ciency See Ordering Guide Maximum Capacitive Loading (Note 14) Cap-ESR=0.001 to 0.01 Ohms 1,000 μf Cap-ESR >0.01 Ohms 3,000 μf (min. cap. load 0 μf) Current Limit Inception (Note 6) (98% of Vout setting, after warm up) 5.5 Amps Short Circuit Mode Short Circuit Current Output 0.0 A Protection Method Hiccup autorecovery upon overload removal. (Note 17) Short Circuit Duration Continuous, no damage (output shorted to ground) Prebias Startup Converter will start up if the external output voltage is less than Vnominal. Dynamic Characteristics Dynamic Load Response 125μSec max. to within ±2% of fi nal value (50-100 load step, di/dt=2.5a/μsec, 5 Vout, Cout = 1&10µF ceramic) Start-Up Time 8 msec for Vout=nominal (Vin On) (Vin on or On/Off to Vout regulated) 6 msec for Vout=nominal (Remote On/Off) Switching Frequency 300 KHz Environmental Calculated MTBF Telecordia method (4a) TBD Calculated MTBF MIL-HDBK-217N2 method (4b) TBD Operating Temperature Range (Ambient) See derating curves -40 to +85 C. with derating (Note 9) Operating PC Board Temperature -40 to +100 Celsius max., no derating (12) Storage Temperature Range -55 to +125 deg. C. Thermal Protection/Shutdown +130 Celsius Relative Humidity to 85%/+85 C., non-condensing Physical Outline Dimensions See Mechanical Specifi cations Weight 0.072 ounces (2.04 grams) Safety Meets UL/cUL 60950-1, CSA- C22.2 No. 60950-1, IEC/EN 60950-1, 2nd Edition Restriction of Hazardous Substances RoHS-6 (does not claim EU RoHS exemption 7b lead in solder) MSL Rating 2 Absolute Maximum Ratings Input Voltage (Continuous or transient) 0 V.to +40 Volts max. On/Off Control 0 V. min. to +Vin max. Input Reverse Polarity Protection None. Install external fuse. Output Current (Note 7) Current-limited. Devices can withstand a sustained short circuit without damage. The outputs are not intended to accept appreciable reverse current. Storage Temperature -55 to +125 C. Lead Temperature See soldering specifi cations Absolute maximums are stress ratings. Exposure of devices to greater than any of any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifi cations Table is not implied nor recommended. Specification Notes: (1) Specifi cations are typical at +25 C, Vin=nominal (+24V.), Vout=nominal (+5V), full load, external caps and natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced airfl ow. All models are tested and specifi ed with external 1 μf paralleled with 10μF ceramic/tantalum output capacitors and a 22 μf external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specifi ed performance in your applications. However, Murata Power Solutions recommends installation of these capacitors. All models are stable and regulate within spec under no-load conditions. (2) Input Back Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input fi ltering is Cin=2 x 100 μf tantalum, Cbus=1000 μf electrolytic, Lbus=1 μh. (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airfl ow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the Derating curve. (4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fi xed conditions, Tpcboard=+25 C, full output load, natural air convection. (4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground benign, +25ºC., full output load, natural convection. MDC_OKI-T/3-W40 Series.A08 Page 3 of 13

Specification Notes, Cont.: (5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed +Vin. (6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. (7) For Vout = 1V, Vin must not exceed 32V. For Vout = 0.75V, Vin must not exceed 24V. (8) Output noise may be further reduced by adding an external fi lter. At zero output current, the output may contain low frequency components which exceed the ripple specifi cation. The output may be operated indefi nitely with no load. (9) All models are fully operational and meet published specifi cations, including cold start at 40 C. (10) Regulation specifi cations describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. (11) Other input or output voltage ranges will be reviewed under scheduled quantity special order. (12) Maximum PC board temperature is measured with the sensor in the center of the converter. (13) Do not exceed maximum power specifi cations when adjusting the output trim. (14) The maximum output capacitive loads depend on the the Equivalent Series Resistance (ESR) of the external output capacitor and, to a lesser extent, the distance and series impedance to the load. Larger caps will reduce output noise but may change the transient response. Newer ceramic caps with very low ESR may require lower capacitor values to avoid instability. Thoroughly test your capacitors in the application. Please refer to the Output Capacitive Load Application Note. (15) Do not allow the input voltage to degrade lower than the input undervoltage shutdown voltage at all times. Otherwise, you risk having the converter turn off. The undervoltage shutdown is not latching and will attempt to recover when the input is brought back into normal operating range. (16) The outputs are not intended to sink appreciable reverse current. (17) Hiccup overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again. This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation. MDC_OKI-T/3-W40 Series.A08 Page 4 of 13

PERFORMANCE DATA OKI-T/3-W40 95 Effi ciency vs. Line Voltage and Load Current @ +25 C (VOUT = 5V) 4 Maximum Current Temperature Derating at Sea Level (VIN= 24-40V, VOUT = 5V, transverse airfl ow, mounted on 10" x 10" PCB). 90 85 3 Efficiency (%) 80 75 70 VIN = 16V VIN = 24V VIN = 40V Output Current (Amps) 2 1 65 LFM 65 60 0 0.5 1 1.5 2 2.5 3 3.5 Load Current (Amps) 0 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (ºC) Output Ripple and Noise (Vin=24V, Vout=5V, Iout=3A, Cload=0, ScopeBW=100MHz) On/Off Enable Startup (Vin=24V, Vout=5V, Iout=3A, Cload=0) Step Load Transient Response (Vin=24V, Vout=5V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. Step Load Transient Response (Vin=24V, Vout=5V, Cload=0, Iout=3A to 1.5A) Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. MDC_OKI-T/3-W40 Series.A08 Page 5 of 13

PERFORMANCE DATA OKI-T/3-W40 100 95 90 85 Effi ciency vs. Line Voltage and Load Current @ +25 C (VOUT = 3.3V) Efficiency (%) 80 75 70 65 60 55 VIN = 16V VIN = 24V VIN = 40V 50 0 0.5 1 1.5 2 2.5 3 3.5 Load Current (Amps) Output Ripple and Noise (Vin=24V, Vout=3.3V, Iout=3A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=24V, Vout=3.3V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. Step Load Transient Response (Vin=24V, Vout=3.3V, Cload=0, Iout=3A to 1.5A) Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. MDC_OKI-T/3-W40 Series.A08 Page 6 of 13

PERFORMANCE DATA OKI-T/3-W40 90 Effi ciency vs. Line Voltage and Load Current @ +25 C (VOUT = 1.5V) 80 70 Efficiency (%) 60 50 VIN = 16V VIN = 24V VIN = 40V 40 30 0 0.5 1 1.5 2 2.5 3 3.5 Load Current (Amps) Output Ripple and Noise (Vin=24V, Vout=1.5V, Iout=3A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=24V, Vout=1.5V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. Step Load Transient Response (Vin=24V, Vout=1.5V, Cload=0, Iout=3A to 1.5A)Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. MDC_OKI-T/3-W40 Series.A08 Page 7 of 13

PERFORMANCE DATA OKI-T/3-W40 80 75 70 65 Effi ciency vs. Line Voltage and Load Current @ +25 C (VOUT = 1.2V) Efficiency (%) 60 55 50 45 40 35 VIN = 16V VIN = 24V VIN = 40V 30 0 0.5 1 1.5 2 2.5 3 3.5 Load Current (Amps) Output Ripple and Noise (Vin=24V, Vout=1.2V, Iout=3A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=24V, Vout=1.2V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. Step Load Transient Response (Vin=24V, Vout=1.2V, Cload=0, Iout=3A to 1.5A) Trace 2=Vout, 100 mv/div. Trace 4=Iout, 1A/div. MDC_OKI-T/3-W40 Series.A08 Page 8 of 13

MECHANICAL SPECIFICATIONS 11.9 0.47 NOZZLE PICKUP POINT TOP VIEW PIN #1 THIS CORNER (FARSIDE) 20.8 0.82 8.4 0.33 REF 4.3 0.17 INPUT/OUTPUT CONNECTIONS OKI-T/3 (P78) Pin Function 1 On/Off Control* 2 Positive VIN 3 Ground (Common) 4 Trim 5 Positive VOUT *The Remote On/Off can be provided with either positive (P suffi x) or negative (N suffi x) logic SIDE VIEW 8.5 0.34 END VIEW PIN #1 ISOMETRIC VIEW MTG PLANE 1.59 0.063 Dimensions are in inches (mm shown for ref. only). 1.60 0.063 TYP 8.63 0.340 0.25 0.010 2.29 0.090 TYP 2 BOTTOM VIEW 3 4 5 8.63 0.340 12.69 0.500 1 1.53 0.060 4.57 0.180 1.78 0.070 2 [17.52] 0.690 [12.69] 0.500 [8.63] 0.340 [4.57] 0.180 1 [1.52] 0.060 REF Third Angle Projection Tolerances (unless otherwise specified):.xx ± 0.02 (0.5).XXX ± 0.010 (0.25) Angles ± 2 Components are shown for reference only. [1.8] 0.070 REF 17.52 0.690 [11.9] 0.47 REF 4 5 3 [8.63] 0.340 DIMENSIONS ARE IN INCHES [mm] TOLERANCES: 2 PLACE 0.02 ANGLES: 1 3 PLACE 0.010 COMPONENTS SHOWN ARE FOR REFERENCE ONLY MATERIAL: SMT PINS: COPPER ALLOY FINISH: (ALL PINS) GOLD (5μ"MIN) OVER NICKEL (50μ" MIN) [3.05] 0.120 MIN [3.43] 0.135 MAX [20.8] 0.82 REF RECOMMENDED PAD LAYOUT [2.41] 0.095 MIN [2.79] 0.110 MAX MDC_OKI-T/3-W40 Series.A08 Page 9 of 13

TAPE AND REEL INFORMATION FEED (UNWIND) DIRECTION ------- 2.00 0.079 4.00 0.157 PIN #1 ROUND HOLES 1.75 0.069 44.00 1.732 18.2 0.72 (P/U) 40.40 1.591 4.00 0.157 NOZZLE DIA 16.00 0.630 KEY IN POCKET OBLONG HOLES 0.365 Dimensions are in inches (mm shown for ref. only). TOP COVER TAPE Third Angle Projection Tolerances (unless otherwise specified):.xx ± 0.02 (0.5).XXX ± 0.010 (0.25) Angles ± 1 Components are shown for reference only. PIN #1 THIS CORNER (FARSIDE) 4.2 0.17 44.0 1.73 REF 8.4 0.33 20.8 0.82 330.2 13.00 PICKUP NOZZLE LOCATION ( 3-4mm) 11.9 0.47 PICK & PLACE PICKUP (P/U) 101.6 4.00 (CORE) 13.00 0.512 REEL INFORMATION (250 UNITS PER REEL) MDC_OKI-T/3-W40 Series.A08 Page 10 of 13

TECHNICAL NOTES Input Fusing Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. For greatest safety, we recommend a fast blow fuse installed in the ungrounded input supply line. The installer must observe all relevant safety standards and regulations. For safety agency approvals, install the converter in compliance with the end-user safety standard, i.e. IEC/EN/UL 60950-1. Input Under-Voltage Shutdown and Start-Up Threshold Under normal start-up conditions, converters will not begin to regulate properly until the ramping-up input voltage exceeds and remains at the Start-Up Threshold Voltage (see Specifi cations). Once operating, converters will not turn off until the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent restart will not occur until the input voltage rises again above the Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a single input voltage. Users should be aware however of input sources near the Under-Voltage Shutdown whose voltage decays as input current is consumed (such as capacitor inputs), the converter shuts off and then restarts as the external capacitor recharges. Such situations could oscillate. To prevent this, make sure the operating input voltage is well above the UV Shutdown voltage AT ALL TIMES. Start-Up Time Assuming that the output current is set at the rated maximum, the Vin to Vout Start-Up Time (see Specifi cations) is the time interval between the point when the ramping input voltage crosses the Start-Up Threshold and the fully loaded regulated output voltage enters and remains within its specifi ed accuracy band. Actual measured times will vary with input source impedance, external input capacitance, input voltage slew rate and fi nal value of the input voltage as it appears at the converter. These converters include a soft start circuit to moderate the duty cycle of its PWM controller at power up, thereby limiting the input inrush current. The On/Off Remote Control interval from On command to Vout regulated assumes that the converter already has its input voltage stabilized above the Start-Up Threshold before the On command. The interval is measured from the On command until the output enters and remains within its specifi ed accuracy band. The specifi cation assumes that the output is fully loaded at maximum rated current. Similar conditions apply to the On to Vout regulated specifi cation such as external load capacitance and soft start circuitry. For best performance, we recommend installing a low-esr capacitor immediately adjacent to the converter s input terminals. The capacitor should be a ceramic type such as the Murata GRM32 series or a polymer type. Initial suggested capacitor values are 10 to 22 μf, rated at twice the expected maximum input voltage. Make sure that the input terminals do not go below the undervoltage shutdown voltage at all times. More input bulk capacitance may be added in parallel (either electrolytic or tantalum) if needed. Recommended Output Filtering The converter will achieve its rated output ripple and noise with no additional external capacitor. However, the user may install more external output capacitance to reduce the ripple even further or for improved dynamic response. Again, use low-esr ceramic (Murata GRM32 series) or polymer capacitors. Initial values of 10 to 47 μf may be tried, either single or multiple capacitors in parallel. Mount these close to the converter. Measure the output ripple under your load conditions. Use only as much capacitance as required to achieve your ripple and noise objectives. Excessive capacitance can make step load recovery sluggish or possibly introduce instability. Do not exceed the maximum rated output capacitance listed in the specifi cations. Input Ripple Current and Output Noise All models in this converter series are tested and specifi ed for input refl ected ripple current and output noise using designated external input/output components, circuits and layout as shown in the fi gures below. The Cbus and Lbus components simulate a typical DC voltage bus. Please note that the values of Cin, Lbus and Cbus will vary according to the specifi c converter model. TO OSCILLOSCOPE VIN + + CBUS LBUS CURRENT PROBE CIN CIN = 2 x 100μF, ESR < 700mΩ @ 100kHz CBUS = 1000μF, ESR < 100mΩ @ 100kHz LBUS = 1μH Figure 3: Measuring Input Ripple Current +INPUT -INPUT Recommended Input Filtering The user must assure that the input source has low AC impedance to provide dynamic stability and that the input supply has little or no inductive content, including long distributed wiring to a remote power supply. The converter will operate with no additional external capacitance if these conditions are met. MDC_OKI-T/3-W40 Series.A08 Page 11 of 13

+OUTPUT CAUTION: If you routinely or accidentally exceed these Derating guidelines, the converter may have an unplanned Over Temperature shut down. Also, these graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. -OUTPUT C1 C2 SCOPE RLOAD Output Fusing The converter is extensively protected against current, voltage and temperature extremes. However your output application circuit may need additional protection. In the extremely unlikely event of output circuit failure, excessive voltage could be applied to your circuit. Consider using an appropriate fuse in series with the output. C1 = 1μF CERAMIC C2 = 10μF TANTALUM LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 4: Measuring Output Ripple and Noise (PARD) Minimum Output Loading Requirements All models regulate within specifi cation and are stable under no load to full load conditions. Operation under no load might however slightly increase output ripple and noise. Thermal Shutdown To prevent many over temperature problems and damage, these converters include thermal shutdown circuitry. If environmental conditions cause the temperature of the DC/DC s to rise above the Operating Temperature Range up to the shutdown temperature, an on-board electronic temperature sensor will power down the unit. When the temperature decreases below the turn-on threshold, the converter will automatically restart. There is a small amount of hysteresis to prevent rapid on/off cycling. CAUTION: If you operate too close to the thermal limits, the converter may shut down suddenly without warning. Be sure to thoroughly test your application to avoid unplanned thermal shutdown. Temperature Derating Curves The graphs in this data sheet illustrate typical operation under a variety of conditions. The Derating curves show the maximum continuous ambient air temperature and decreasing maximum output current which is acceptable under increasing forced airfl ow measured in Linear Feet per Minute ( LFM ). Note that these are AVERAGE measurements. The converter will accept brief increases in current or reduced airfl ow as long as the average is not exceeded. Note that the temperatures are of the ambient airfl ow, not the converter itself which is obviously running at higher temperature than the outside air. Also note that natural convection is defi ned as very fl ow rates which are not using fan-forced airfl ow. Depending on the application, natural convection is usually about 30-65 LFM but is not equal to still air (0 LFM). Murata Power Solutions makes Characterization measurements in a closed cycle wind tunnel with calibrated airfl ow. We use both thermocouples and an infrared camera system to observe thermal performance. As a practical matter, it is quite diffi cult to insert an anemometer to precisely measure airfl ow in most applications. Sometimes it is possible to estimate the effective airfl ow if you thoroughly understand the enclosure geometry, entry/exit orifi ce areas and the fan fl owrate specifi cations. Output Current Limiting Current limiting inception is defi ned as the point at which full power falls below the rated tolerance. See the Performance/Functional Specifi cations. Note particularly that the output current may briefl y rise above its rated value in normal operation as long as the average output power is not exceeded. This enhances reliability and continued operation of your application. If the output current is too high, the converter will enter the short circuit condition. Output Short Circuit Condition When a converter is in current-limit mode, the output voltage will drop as the output current demand increases. If the output voltage drops too low (approximately 98% of nominal output voltage for most models), the magnetically coupled voltage used to develop primary side voltages will also drop, thereby shutting down the PWM controller. Following a time-out period, the PWM will restart, causing the output voltage to begin ramping up to its appropriate value. If the short-circuit condition persists, another shutdown cycle will initiate. This rapid on/off cycling is called hiccup mode. The hiccup cycling reduces the average output current, thereby preventing excessive internal temperatures and/or component damage. A short circuit can be tolerated indefi nitely. The hiccup system differs from older latching short circuit systems because you do not have to power down the converter to make it restart. The system will automatically restore operation as soon as the short circuit condition is removed. Remote On/Off Control On the input side, a remote On/Off Control can be ordered with either logic type. Please refer to the Connection Diagram on page 1 for On/Off connections. Positive-logic models are enabled when the On/Off pin is left open or is pulled high to +Vin with respect to Vin. Positive-logic devices are disabled when the On/Off is grounded or brought to within a low voltage (see Specifi cations) with respect to Vin. Negative-logic devices are on (enabled) when the On/Off is left open or brought to within a low voltage (see Specifi cations) with respect to Vin. The device is off (disabled) when the On/Off is pulled high (see Specifi cations) with respect to Vin. Dynamic control of the On/Off function should be able to sink appropriate signal current when brought low and withstand appropriate voltage when brought high. Be aware too that there is a fi nite time in milliseconds (see Specifi cations) between the time of On/Off Control activation and stable, regulated output. This time will vary slightly with output load type and current and input conditions. MDC_OKI-T/3-W40 Series.A08 Page 12 of 13

Output Capacitive Load These converters do not require external capacitance added to achieve rated specifi cations. Users should only consider adding capacitance to reduce switching noise and/or to handle spike current load steps. Install only enough capacitance to achieve noise objectives. Excess external capacitance may cause regulation problems, degraded transient response and possible oscillation or instability. Output Voltage Adustment The output voltage may be adjusted over a limited range by connecting an external trim resistor (Rtrim) between the Trim pin and Ground. The Rtrim resistor must be a 1/10 Watt precision metal fi lm type, ±1% accuracy or better with low temperature coeffi cient, ±100 ppm/oc. or better. Mount the resistor close to the converter with very short leads or use a surface mount trim resistor. In the tables below, the calculated resistance is given. Do not exceed the specifi ed limits of the output voltage or the converter s maximum power rating when applying these resistors. Also, avoid high noise at the Trim input. However, to prevent instability, you should never connect any capacitors to Trim. Output Voltage Calculated Rtrim (KΩ) 5 V. 1.472 3.3 V. 3.122 2.5 V. 5.009 2.0 V. 7.417 1.8 V. 9.024 1.5 V. 13.047 1.2 V. 22.464 1.0 V. 41.424 0.7525 V. (open) Resistor Trim Equation: RTRIM ( ) = 10500 1000 VOUT 0.7525V Soldering Guidelines Murata Power Solutions recommends the specifi cations below when installing these converters. These specifi cations vary depending on the solder type. Exceeding these specifi cations may cause damage to the product. Your production environment may differ therefore please thoroughly review these guidelines with your process engineers. Recommended Lead-free Solder Reflow Profile Temperature ( C) 250 200 150 100 50 Reflow Solder Operations for surface-mount products (SMT) For Sn/Ag/Cu based solders: Preheat Temperature Time over Liquidus Maximum Peak Temperature Cooling Rate For Sn/Pb based solders: Preheat Temperature Time over Liquidus Maximum Peak Temperature Cooling Rate <1.5 C/sec 0 0 30 60 90 120 150 180 210 240 270 300 High trace = normal upper limit Low trace - normal lower limit Peak Temp. 235-260 C Soaking Zone 120 sec max Preheating Zone 240 sec max Less than 1 ºC. per second 45 to 75 seconds 260 ºC. Less than 3 ºC. per second Less than 1 ºC. per second 60 to 75 seconds 235 ºC. Less than 3 ºC. per second Time (sec) Reflow Zone time above 217 C 45-75 sec Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. 2013 Murata Power Solutions, Inc. MDC_OKI-T/3-W40 Series.A08 Page 13 of 13

Murata Power Solutions 社 (MPS 社 ) 製 品 の 取 り 扱 い 上 の 注 意 1. 製 品 の 運 搬 時 電 子 部 品 等 に 力 を 加 えたり 力 が 加 わる 様 な 作 業 をしないで 下 さい 2. 以 下 のような 環 境 条 件 では 絶 縁 劣 化 を 引 き 起 こす 危 険 性 がありますので 設 置 及 び 保 管 しないでください 本 仕 様 書 の 規 格 外 の 高 温, 高 湿 の 保 存 や 直 射 日 光 の 当 たるところ 腐 食 性 ガス 雰 囲 気 (Cl2 H2S NH3 SO2 NOX 等 ) 水 油 有 機 溶 剤 等 の 液 体 がかかるところ 塵 埃 の 多 いところ その 他 上 記 に 準 ずるところ 3. 低 分 子 シロキサン(ジメチルポリシロキサン) 含 有 率 の 高 いシリコンゴム シリコンボンド 等 の 使 用 により ボリウ ムやポテンショメータ 摺 動 子 やスイッチ 類 の 接 点 の 接 触 不 良 が 発 生 する 場 合 があります 低 分 子 シロキサン 含 有 率 は0.1% 以 下 のものをご 使 用 ください 4. 製 品 に 使 用 されている 個 々の 部 品 は 周 囲 温 度 により その 信 頼 性 と 寿 命 (MTBF)は 極 端 に 短 くなります 当 データシートに 定 められている 温 度 条 件 の 範 囲 内 で 使 用 してください お 願 い 1. 本 データシートは 特 に 規 定 しない 限 り 電 源 単 体 での 品 質 を 規 定 するものです ご 使 用 に 際 しては 御 社 製 品 に 実 装 された 状 態 で 必 ず 評 価 確 認 をして 下 さい 2. 当 製 品 に 万 が 一 異 常 や 不 具 合 が 生 じた 場 合 でも 2 次 災 害 防 止 の 為 に 完 成 品 に 適 切 なフェールセーフ 機 能 を 必 ず 付 加 して 下 さい 3. 当 データシートに 記 載 の 製 品 について その 故 障 や 誤 動 作 が 人 命 又 は 財 産 に 危 害 を 及 ぼす 恐 れがある 等 の 理 由 により 高 信 頼 性 が 要 求 される 以 下 の 用 途 でのご 使 用 をご 検 討 の 場 合 又 は 当 データシートに 記 載 され た 用 途 以 外 でのご 使 用 をご 検 討 の 場 合 は 必 ず 事 前 に 弊 社 営 業 部 又 は 最 寄 りの 営 業 所 までご 連 絡 下 さい 1 航 空 機 器 2 宇 宙 機 器 3 海 底 機 器 4 発 電 所 制 御 機 器 5 防 災 / 防 犯 機 器 6 交 通 用 信 号 機 器 7 輸 送 機 器 ( 自 動 車 列 車 船 舶 等 ) 8 医 療 機 器 9 情 報 処 理 機 器 10その 他 上 記 機 器 と 同 等 の 機 器 4. 記 載 内 容 について 改 良 のため 予 告 なく 変 更 することや 供 給 を 停 止 することがございますので ご 注 文 に 際 してはご 確 認 下 さい 記 載 内 容 にご 不 明 の 点 がございましたら 弊 社 営 業 部 までお 問 い 合 わせ 下 さい 5. 製 品 によっては お 守 りいただかないと 発 煙 発 火 等 に 至 る 可 能 性 のある 定 格 や 注 意 ( 保 管 使 用 環 境 定 格 上 の 注 意 実 装 上 の 注 意 取 扱 上 の 注 意 )を 記 載 しておりますので 必 ずご 覧 下 さい 6. 当 データシートに 記 載 の 製 品 の 使 用 もしくは 当 データシートに 記 載 の 情 報 の 使 用 に 際 して 当 社 もしくは 第 三 者 の 知 的 財 産 権 その 他 の 権 利 にかかわる 問 題 が 発 生 した 場 合 は 当 社 はその 責 を 負 うものではありません ま た これらの 権 利 の 実 施 権 の 許 諾 を 行 うものではありません 7. 当 データシートの 製 品 が 外 国 為 替 及 び 外 国 貿 易 法 に 定 める 規 制 貨 物 等 に 該 当 するものについては 輸 出 する 場 合 同 法 に 基 づく 輸 出 許 可 が 必 要 です 8. MPS 社 の 製 造 工 程 では モントリオール 議 定 書 で 規 制 されているオゾン 層 破 壊 物 資 (ODS)は 一 切 使 用 しており ません