Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC



Similar documents
Dispersion penalty test 1550 Serial

Golden test for dispersion penalty 1550 Serial

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

Intel Ethernet SFP+ Optics

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

How To Get A Better Signal From A Fiber To A Coax Cable

LONGLINE 40km XFP Optical Transceiver

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

CISCO 10GBASE X2 MODULES

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

10GBASE -LRM, 220m Reach GX LRMC

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

LONGLINE 2km XFP Optical Transceiver

X2 LR Optical Transponder, 10Km Reach

1.25Gbps GBIC Optical Transceiver, 20km Reach

Multi-Gigabit Interfaces for Communications/Datacomm

DWDM SFP Series. Power budget* (note2) Laser

4.25Gbps SFP Optical Transceiver, 30km Reach

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

155Mbps DFB SFP Optical Transceiver, 120km Reach

Attaching the PA-A1-ATM Interface Cables

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

DWDM SFP Series. Power budget* (note2) Laser

SFP Transceiver Specifications

Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features

The 10G Ethernet Link Model

XFP Optical Receiver, 80km Reach

Introduction to Optical Link Design

Product Specification 10Gb/s BIDI SFP+ Transceiver

Your Network. Our Connection. 10 Gigabit Ethernet

Designing Fiber Optic Systems David Strachan

PCI Express: The Evolution to 8.0 GT/s. Navraj Nandra, Director of Marketing Mixed-Signal and Analog IP, Synopsys

10GBASE-LR XFP Optical Transceiver AXM752

8B/10B Coding 64B/66B Coding

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet

Dual Fiber SFP Series

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Cisco SFP Optics for Gigabit Ethernet Applications

Optical Communications Analysis of transmission systems. Henrique Salgado Point-to-point system

Prisma IP 10 GbE VOD Line Card

Georgia Tech 100G Center

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Fibre Channel Fiber Cabling

Simulation and Best Design of an Optical Single Channel in Optical Communication Network

GBIC CWDM 40km Part no:

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

Advanced Modulation Formats in Data Centre Communications Michael J. Wale Director Active Products Research

Plastic Optical Fiber for In-Home communication systems

Enabling the Business Continuity & Change the way business communicates

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

Network Topologies and Distances

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

With the advent of Gigabit Ethernet

Trends In Data Rate And Link Length In Evolving Optical Standards

Optical transmission systems over Plastic Optical Fiber (POF) at high bit rate

Recent developments in high bandwidth optical interconnects. Brian Corbett.

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

Preparing Infrastructure for 10 Gigabit Ethernet Applications

5 PMD Proposal and 850 nm Serial Specifications and Criteria. List of Supporters

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

10GBASE-SR XFP Optical Transceiver AXM751

A Gigabit Transceiver for Data Transmission in Future HEP Experiments and An overview of optoelectronics in HEP

1000BASE-BX-OLT Transceiver

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Cable Systems

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

GPON OLT Optical Transceiver SFP Module RTXM Features

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

PCI-SIG ENGINEERING CHANGE NOTICE

Wavelength Division Multiplexing

Modeling and Performance Analysis of DWDM Based 100 Gbps Low Power Inter-satellite Optical Wireless Communication (LP-IsOWC) System

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Understanding Ethernet and Fibre Channel Standard-Based Test Patterns An explanation of IEEE and NCITS standard test patterns By Todd Rapposelli

Implementation of Short Reach (SR) and Very Short Reach (VSR) data links using POET DOES (Digital Opto- electronic Switch)

Pericom PCI Express 1.0 & PCI Express 2.0 Advanced Clock Solutions

155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper

The ABC of Direct Attach Cables

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

Optimux-134, Optimux-125

Cisco 10GBASE SFP+ Modules

Transcription:

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC John Crow,, IBM Watson Research Center, jdcrow@us.ibm.com Dan Kuchta,, IBM Watson Research Center, kuchta@us.ibm.com Mounir Meghelli,, IBM Watson Research Center, meghelli@us.ibm.com Petar Pepeljugoski,, IBM Watson Research Center, petarp@us.ibm.com Israel Ury,, Ortel Corporation, iury@ortel.com

Features of Low Cost High Speed ICs (SiGe and CMOS) are Less Expensive than OE Chips Uncooled Optics for LAN spans Adapt Technology from Multiple, Existing Suppliers Transceivers developed by many suppliers Capitalize on high BW MMF's; & existing SMF cable suppliers Multiple IC Foundries Extensions of Existing Standard Serial Package Technology User Familiarity with TDM 1 GbE, FCS Can use existing LAN installation methodology/infrastructure

Objectives of These Presentations IBM Presentation Demonstration of a serial optical link prototype exceeding the requirements of 10 GbE, 10 km, LAN, PHY Relates this link technology to Extensions of the 1 GbE Tables of Link and Transmitter / Receiver Specifications Ortel Presentation Presents Data Supporting Manufacturability

Link Demonstration Stressed the 12.5Gbd/10km option: operated at 13 Gbd, 14 km Ortel Transmitter and Receiver Modules IBM SiGe Clock & Data Recovery IC Ortel Tx Ortel Rcv Receiver Output 'eye" Recovered Data and Clock

Link Components Transmitter Ortel DFB laser with isolator Driven by Pattern Generator with 2 7-1 5 bias conditions tested, near I th for high extinction and to stress jitter 12.5 Gbaud and 13.0 Gbaud tested Receiver Ortel PD with preamp External AC coupled post-amp for 200 mv pp to CDR IC Clock and data recovery IC (CDR) SiGe BiCMOS from IBM Foundry, f t > 45 GHz (HBT), 0.5 mm (CMOS) Single chip CDR, 3.3-3.6 V Designed for 12.5 Gbaud

Long Wavelength Transmitter Characteristics (extension of IEEE 802.3z Table 38.7) Description Current Link Stressed Measurements Tentative Spec. Unit Signaling speed 13.0 12.5 GBd Wavelength 1310 1290-1325 nm τ rise /τ fall (20-80%) 14.6 ps / 31 ps 25 ps Spectral width 0.30 0.5 nm, cw Launch power (max) +1.9 +2 dbm, avg. Launch power (min) -4 dbm, avg. Extinction Ratio(min) 10 6 db RIN -132.6-140 db/hz SMSR 40.2 30 db

Long Wavelength Receiver Characteristics (extension of IEEE 802.3z Table 38.8) Description Current Link Stressed Measurements Tentative Spec. Unit Signaling Speed 13.0 12.5 GBd Wavelength 1310 1290-1325 nm Receiver power (max) Receiver power (min) +1.9 +2 dbm,avg -16 @ BER 10-12 -14 dbm,avg Return loss 40 26 dbm

Worst case link power budget & penalties (extension of IEEE 802.3z Table 38.9) Long Wavelength Description Current Link Tentative Spec. Unit Measurement SMF-DFB Modal Bandwidth N/A N/A MHz*km Link power budget 17.9 10 db Operating distance 14 10 km Channel insertion loss 5.3 7 db Link power penalties - 2.7 db Unallocated margin - 0.3 db

Link Jitter Budget (extension of IEEE 802.3z Table 38-10) TP1 TP2 TP3 TP4 PMA T- T+ Optical Transmit- Patch Cord Optical Receiver R- R+ PMA Fiber Optic Cable (Channel) Table 38-10,802.3z Figure 1. Definition of jitter test points. Deterministic Jitter, UI Total Jitter, UI TP1 0.1 0.24 TP1 to TP2 0.1 0.287 TP2 0.2 0.431 TP2 to TP3 0.05 0.170 TP3 0.25 0.510 TP3 to TP4 0.212 0.332 Does jitter just scale according to UI? Initial measurements made on one link at 12.5 Gbaud. TP4 0.462 0.749

Link Jitter Budget (cont.) (extension of IEEE 802.3z Table 38-10) Deterministic Jitter Scaled from 1GbE (psec) Deterministic Jitter measured (psec) 1 s of RJ ( psec) @ TP1 8 7 1.7 @ TP2 16 20.4 1.9 @ TP3 20 21.7 2 @ TP4 37 18.7 2.1 DJ,RJ difficult to measure/correlate to TP's, but overall RJ,TJ looks manageable. Link driven close to I th to enhance jitter Used 2 7-1 run length (~8B/10B) Might be worse at 10 Gbaud and with long run length codes Jitter Budget allocation to be resolved by 802.3ae sub-group

Implications of Link Demonstration 10 Gigabit/sec links with 12.5 Gbaud signaling rates are feasible Allows robust codes for reliable link operation Compatible with 1 GbE and FCS standards. Optical Transceiver Products From Current Production can be adapted to 10 GbE LAN Requirements Elimination of cooling allows migration to smaller, lower power, lower cost Transceiver Modules SiGe BiCMOS From Foundry can provide CDR function as IC All high speed functions? In single IC? This Demonstration Supports the Group Claim of a Volume Manufacturable, Low Cost PHY Technology