162300 536204 162345 162301 (shown twice size) Yankauer Suction Tubes YANKAUER SUCTION TUBES Standard adult size. 10 mm diameter. Tip has 2 mm central opening and four 2 mm side openings. 162300 12 1/2" (31.8 cm) length 162301 Tip only for 162300 Yankauer YANKAUER SUCTION TUBE With detachable handle. 536204 12 1/2" (31.7 cm) length YANKAUER SUCTION TUBE TIP Removable tip 9 mm. Shaft diameter 6.5 mm. 536203 Tips only, package of 6 YANKAUER SUCTION TUBE WITH SWITCH VALVE For use with wall suction. Stopcock type valve allows reliable on-off action. Tube is detachable for cleaning. 162345 12 1/4" (31.1 cm) length 77
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 MILLIMETERS 78 351500 351508 351503 351506 351501 (shown twice size) DeBakey Suction Tubes DEBAKEY SUCTION TUBE 351500 12 1/4" (31.1 cm) length, 9 mm diameter DEBAKEY SUCTION TUBE TIP 351501 Tip for 351500 FIBEROPTIC ILLUMINATED SUCTION TUBE A modification of the DeBakey-Yankauer tube but with special tip to provide for greater volume of aspirated fluids. Large distal central opening is surrounded by circular perforations and slots in the sides. 351508 Tip is 9 mm diameter DEBAKEY SUCTION TUBES Small diameter, curved tubes with finger valve control. 351502 11 1/8" (28.2 cm) length, diameter 3 mm 351503 12 1/8" (30.7 cm) length, diameter 4.5 mm DEBAKEY-ADSON CORONARY SUCTION TUBE Distal opening with four side openings 3 mm long, 4 mm diameter. 351504 6 1/16" (15.3 cm), 4" (10.2 cm) working length 351506 8 1/16" (20.4 cm), 6" (15.2 cm) working length
536220 351505 162310 351545 351547 351733 351734 Andrews Suction Tubes ANDREWS PYNCHON SUCTION TUBE 536220 10 1/2" (26.6 cm) length, tip 6 mm, removable shaft, diameter 3 mm MORSE-ANDREWS SUCTION TUBE Short length, small 3 mm outside diameter tube, terminating in 6 mm diameter tip which has one distal and four side openings. 351505 10 1/4" (26 cm) length ANDREWS INFANT SUCTION TUBE 162310 10" (25.4 cm) length, tip permanently attached, 6 mm diameter tip Cooley Suction Tubes COOLEY INTRACARDIAC SUCTION TUBE 3/16" plastic tubing may be slipped inside to the tip to provide smooth, disposable inner lining. Detachable 9 mm diameter distal tip contains four large side and one end aperture. 351545 7 1/8" (18 cm) length COOLEY SUMP SUCTION TUBE Long, removable perforated outer tube with internal extension provides for fluid removal by sump-drain principle. Entire tube removable from handle for cleaning and rotatable for convenience. Tip diameter 7.5 mm. 351547 Angled, 13" (33 cm) length Atrial Suction Tubes ATRIAL SUMP SUCTION TUBES 351733 Atrial sump, left 7 3/16" (18.2 cm) length 351734 Atrial sump, right 4 5/8" (11.7 cm) length 79
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 MILLIMETERS 80 162210 162212 536107 162422 162415 Miscellaneous Suction, Aspirating Tubes POOL ABDOMINAL SUCTION TUBES Removable inner tube in multi-perforated outer tube. 162210 Large 30 Fr. diameter, straight connector 9 1/4" (23.5 cm) length 162212 Small 23 Fr. diameter, curved connector 10 1/4" (26 cm) length PEDIATRIC POOLE SUCTION TUBE 536107 16 Fr., 7 3/4" (19.5 cm) length FERGUSON-FRAZIER (NEURO) SUCTION TUBES Stainless steel tubes, block-type finger valve, complete with cleaning stylette. Angled. 162410 #0, 6 Fr. 162411 #1, 7 Fr 162412 #2, 8 Fr. 162413 #3, 9 Fr. 162414 #4, 10 Fr. 162415 #5, 12 Fr. 162416 #6, 14 Fr. 162421 Ferguson Stylet #0 162422 Ferguson Stylet #1-2-3 162423 Ferguson Stylet #4-5-6
351560 351573 351574 351575 351576 351577 351578 351586 351587 Heparin Cannulae HEPARIN CANNULA WITH LUER-LOK A complete line of stainless steel, re-usable Heparin Cannula. A selection of sizes, shapes and lengths provides for a variety of uses in flushing, irrigation and injection. Applications include peripheral vascular, cardiac, general, orthopedic, urology and neuro surgery. 351560 Stoney Heparin Injector 1 7/8" (4.7 cm) length 351573 Zanger Heparin Cannula Malleable, 4 mm tip, 2 1/2" (6.3 cm) length 351574 Horsley Heparin Cannula 2 5/16" (5.8 cm) length 351575 DeBakey Heparin Cannula Malleable, 3 mm tip, 2 1/2" (6.3 cm) length 351576 DeBakey Heparin Cannula Malleable, 3.7 mm tip, 2 1/8" (5.5 cm) length 351577 DeBakey Heparin Cannula Malleable, 4 mm tip, 5 15/16" (15 cm) length 351578 I.M.A. Heparin Cannula Malleable, 1.5 mm tip, 2 1/8" (5.3 cm) length 351586 Garrett Heparin Injector Malleable, 5/16" (8 mm) tip, 4 5/16" (10.9 cm) length 351587 Garrett Heparin Injector Malleable, 1/2" (12 mm) tip, 4 3/4" (12 cm) length 351593 Samson Heparin Injector Malleable, small 7 mm tip, 3 3/8" (8.5 cm) 351594 Samson Heparin Injector Malleable, medium 9 mm tip, 3 1/4" (8.2 cm) 351595 Samson Heparin Injector Malleable, large 11 mm tip, 3 1/4" (8.2 cm) 351593 351594 351595 81
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 MILLIMETERS 82 507335 507336 161525 161530 161540 351558 Luer Lok Connectors CHRISTMAS TREE ADAPTERS 507335 Bonnier Catheter Adapter 507336 Luer-Lok Catheter Adapter Air Vent NEVILLE ASCENDING AORTIC AIR VENT NEEDLE 18 ga. Designed to release entrapped air following open heart surgery. The needle has a side vent to assure complete air escape above the point. The stop is provided with two holes for temporary suture placement. 351558 13/16" (2 cm) length Biopsy and Infusion Needles BIOPSY NEEDLES-SILVERMAN TYPES These needles consist of needle with fitted stylette for insertion and a split cannula for biopsy taking. 161525 Silverman liver, 14 ga., 3 3/8" (8.6 cm), Split cannula 17 ga. 161530 Silverman liver, thin wall, 14 ga., 3 3/8" (8.6 cm), Split cannula 16 ga. 161540 Modified Franklin-Silverman, Liver biopsy needles, thin wall
161543 161550 161562 343295 161650 Biopsy and Infusion Needles (continued) BIOPSY NEEDLES-SILVERMAN TYPES (continued) These needles consist of needle with fitted stylette for insertion and a split cannula for biopsy taking. 161543 Split cannula has sharp-edged tabs to slice biopsy out and give better specimen retention. Split cannula 16 ga. 14 ga., 3 3/8" (8.6 cm) 14 ga., 4 1/2" (11.4 cm) 161550 Conrad-Crosby modified Silverman for iliac crest 14 ga., 2" (5 cm) outer cannula Blunt, tapered split cannula MENGHINI TECHNIQUE ASPIRATING NEEDLE Special bevel, thin wall needle. With initial puncture trocar, biopsy retaining pin stop and obturator for specimen removal. Used with suction syringe for biopsy of liver or kidney. 161562 18 ga. x 2 3/4" (7 cm) 161565 17 ga. x 2 3/4" (7 cm) 161567 16 ga. x 2 3/4" (7 cm) 161585 17 ga. x 4 3/4" (12 cm) 161592 16 ga. x 4 3/4" (12 cm) ABRAMS PLEURAL BIOPSY Inner cannula acts as a guillotine to cut and retain specimen. Luer lock syringe fitting. 343295 Needle, with trocar point 13 gauge needle 5 5/8" (14.2 cm) long COPE NEEDLE Consists of an 11 ga. outer needle with square cut end tapered to a sharp edge and a special needle stop for penetration control, plus a 13 ga. inner puncture needle with fitted stylet and a 13 ga. curette-like (hook-like) needle to serve as a very sharp biopsy snare. 161650 11 ga. 3" (7.6 cm), for pleural biopsy 83