1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet



Similar documents
1.25Gbps GBIC Optical Transceiver, 20km Reach

155Mbps DFB SFP Optical Transceiver, 120km Reach

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

4.25Gbps SFP Optical Transceiver, 30km Reach

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

Product Specification 10Gb/s BIDI SFP+ Transceiver

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

DWDM SFP Series. Power budget* (note2) Laser

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

DWDM SFP Series. Power budget* (note2) Laser

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable

Dual Fiber SFP Series

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

LONGLINE 40km XFP Optical Transceiver

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

GPON OLT Optical Transceiver SFP Module RTXM Features

Intel Ethernet SFP+ Optics

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

1000BASE-BX-OLT Transceiver

EPON ONU Optical Transceiver SFF Module

LONGLINE 2km XFP Optical Transceiver

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

** Information Specification ** SFF-8053 Rev 5.5

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

XFP Optical Receiver, 80km Reach

10/100/1000BASE-T SFP Transceiver

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

10GBASE-SR XFP Optical Transceiver AXM751

10GBASE-LR XFP Optical Transceiver AXM752

SFP Copper Transceiver 10/100/1000Base-T

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

155Mbps ATM-Single Mode Transceiver

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

10GBASE -LRM, 220m Reach GX LRMC

GBIC CWDM 40km Part no:

X2 LR Optical Transponder, 10Km Reach

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

Part No. Data Rate Wavelength Interface Temp. DDMI

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

Dispersion penalty test 1550 Serial

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

CISCO 10GBASE X2 MODULES

Cisco SFP Optics for Gigabit Ethernet Applications

Introduction to Optical Link Design

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

DATA SHEET DVI - HDCP Extension Cable

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Enabling the Business Continuity & Change the way business communicates

MASW TB. GaAs SPST Switch, Absorptive, Single Supply, DC-4.0 GHz. Features. Pin Configuration 1,2,3,4. Description. Ordering Information

How To Get A Better Signal From A Fiber To A Coax Cable

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

Golden test for dispersion penalty 1550 Serial

HARTING mcon 1000 Introduction and features

+5 V Powered RS-232/RS-422 Transceiver AD7306

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

DM/SP7041-X 1000BASE-T

SFP Transceiver Specifications

Fiber Optics and Liquid Level Sensors Line Guide

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC

HP ProCurve High-Speed Transceivers Installation Guide

BF15U REV DESCRIPTION DATE APPROVED 2 Preliminary 1/7/2016 RAS/MF

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

FOM-5A, 6A. Asynchronous Fiber Optic Modem

ACT4077 Driver for MACAIR A3818, A5690, A5232, A4905 & MIL-STD-1553

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Perle 10/100 Ethernet Media Converters

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

Perle Fast Fiber to Fiber. Media Converters

AN460 Using the P82B96 for bus interface

Perle Gigabit Fiber to Fiber Media Converters

HARTING econ 3000 Introduction and features

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Gigabit Switching Ethernet Media Converters - Product User Guide

Speed Controller 4-Quadrant PWM configurable via PC

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

Transcription:

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet 3.3V: GBIC-1250A4FS (500m) GBIC-1250B4QS (10km) 5V: GBIC-1250A3FS (500m) GBIC-1250B3QS (10km) Features Compliant with Gigabit Interface Converter (GBIC) Revision 5.4 Compliant with proposed specifications for IEEE 802.3z/Gigabit Ethernet. GBIC-1250Axxx compliant with the 1.0625GBd FC-PI 100-M5-SN-I and 100-M6-SN-I Rev.13 GBIC-1250Bxxx compliant with the 1.0625GBd FC-PI 100-SM-LC-L Rev.13 Single 5V or 3.3V Power Supply Operation TTL Logic TX_DISABLE / TX_FAULT / RX_LOS functions Class 1 Laser Product Compliant with the Requirements of IEC 60825-1 and IEC 60825-2 Hot-Pluggable Description The GBIC-1250A3/A4FS and GBIC-1250B3/B4QS families are compliant with GBIC interface converters specification Rev. 5.4 as well as Gigabit Ethernet standard as specified in IEEE 802.3z. Delta s GBIC transceiver family uses a 20-pin connector to allow hot plug capability. The system designer can make configuration changes or maintenance simply by plugging in different type of converters without removing the power supply from the host system. Applications 1.25 Gigabit Ethernet Fiber Channel Switch to Switch Interface File server interface Performance GBIC-1250A3FS: (5V) 850nm VCSEL, up to 500m in 50/125um MMF or up to 220m in 62.5/125um MMF GBIC-1250B3QS: (5V) 1310nm MQW FP laser, up to 10km in SMF GBIC-1250A4FS: (3.3V) 850nm VCSEL, up to 500m in 50/125um MMF or up to 220m in 62.5/125um MMF GBIC-1250B4QS: (3.3V) 1310nm MQW FP laser, up to 10km in SMF 1 2003/August

Absolute Maximum Ratings Parameter Symbol Min. Typ. Max. Unit Notes Storage Temperature Ts -40 85 ºC Supply Voltage VCC 0 6 V Recommended Operating Conditions Parameter Symbol Min. Typ. Max. Unit Notes Ambient Operating Temperature T A 0 70 Supply voltage GBIC-1250A3FS GBIC-1250B3QS GBIC-1250A4FS GBIC-1250B4QS Vcc 4.75 4.75 3.135 3.135 5 5 3.3 3.3 5.25 5.25 3.475 3.475 Total Supply I S 300 ma Data Output Load R DL 75 Ω V 2 2003/August

GBIC-1250A3FS and GBIC-1250A4FS GBIC-1250x3xx and x4xx Series Transceiver Transmitter Electro-Optical Performance Specifications: (T A =0 C to 70 C, V CC =3.15V to 3.45V for GBIC-1250A4FS or V CC =4.75V to 5.25V for GBIC-1250A3FS) Parameter Symbol Min. Typ. Max. Unit Notes Differential Data Input Voltage V DI 650 2000 mv TX Current ICC RX 160 ma TX_Fault Load Resistor R TX_FAULT 4.7 10 kω TX_Fault Output Voltage (High) V TF,H Host_Vcc-0.5 Host_Vcc+0.3 V TX_Fault Output Voltage (Low) V TF,L 0 0.5 V TX_Disable Input Voltage (High) V Dis,H 2 Vcc+0.3 V TX_Disable Input Voltage (Low) V Dis,L 0 0.8 V Average Launched Power P O -9.5-4 dbm Optical Rise/fall Time t r/f 0.26 ns Optical extinction ratio ER 9 db Center wavelength λc 830 850 860 nm Spectral Width (RMS) σ 0.85 nm Relative Intensity Noise RIN -117 db/hz Receiver Electro-Optical Performance Specifications: Pullup to Vcc on host board (T A =0 C to 70 C, V CC =3.15V to 3.45V for GBIC-1250A4FS or V CC =4.75V to 5.25V for GBIC-1250A3FS) Parameter Symbol Min. Typ. Max. Unit Notes Differential Data Output Voltage V DO 370 2000 mv RX Current ICC RX 130 ma Receiver Loss of Signal Load R RX_LOS 4.7 10 kω Pullup to Vcc on host board RX Optical Input Power (avg.) P IN -17-3 dbm [1] Optical Wavelength λ 830 850 860 nm Output Data Risetime t r 0.4 ns [2] Output Data Falltime t f 0.4 ns [2] RX_LOS Output Voltage (High) V LOS,H Host_Vcc-0.5 Host_Vcc+0.3 RX_LOS Output Voltage (Low) V LOS,L 0 0.5 RX_LOS Deassert P A -17 dbm RX_LOS Assert P D -30 dbm RX_LOS - Hysteresis P A -P D 1 5 db Note: 1. With BER better than or equal to 1x10-12, measured in the center of the eye opening with 1.25Gb/sec, 2 7-1 NRZ PRBS 2. These are 20%~80% values 3 2003/August

GBIC-1250B3QS and GBIC-1250B4QS GBIC-1250x3xx and x4xx Series Transceiver Transmitter Electro-Optical Performance Specifications: (T A =0 C to 70 C, V CC =3.15V to 3.45V for GBIC-1250B4QS or V CC =4.75V to 5.25V for GBIC-1250B3QS) Parameter Symbol Min. Typ. Max. Unit Notes Differential Data Input Voltage V DI 650 2000 mv TX Current ICC RX 160 ma Transmitter Fault Load Resistor R TX_FAULT 4.7 10 kω Pullup to Vcc on host board TX_Fault Output Voltage (High) V TF,H Host_Vcc-0.5 Host_Vcc+0.3 V TX_Fault Output Voltage (Low) V TF,L 0 0.5 V TX_Disable Input Voltage (High) V Dis,H 2 Vcc+0.3 V TX_Disable Input Voltage (Low) V Dis,L 0 0.8 V Average Launched Power P O -9.5-3 dbm Optical extinction ratio ER 9 db Center wavelength λc 1274 1310 1355 nm Spectral Width σ 4 nm Relative Intensity Noise RIN -120 db/hz Receiver Electro-Optical Performance Specifications: (T A =0 C to 70 C, V CC =3.15V to 3.45V for GBIC-1250B4QS or V CC =4.75V to 5.25V for GBIC-1250B3QS) Parameter Symbol Min. Typ. Max. Unit Notes Differential Data Output Voltage V DO 370 2000 mv RX Current ICC RX 130 ma Receiver Loss of Signal Load R RX_LOS 4.7 10 kω Pullup to Vcc on host board Optical Input Sensitivity (avg.) P IN -19 dbm [1] Optical Input Saturation (avg.) P SAT -3 dbm Optical Wavelength λ 1274 1310 1355 nm Output Data Risetime t r 0.4 ns [2] Output Data Falltime t f 0.4 ns [2] RX_LOS Output Voltage (High) V LOS,H Host_Vcc-0.5 Host_Vcc+0.3 V RX_LOS Output Voltage (Low) V LOS,L 0 0.5 V RX_LOS Deassert P A -19 dbm RX_LOS Assert P D -30 dbm RX_LOS - Hysteresis P A -P D 1 5 db Note: 1. With BER better than or equal to 1x10-12, measured in the center of the eye opening with 1.25Gb/sec, 2 7-1 NRZ PRBS. 2. These are 20%~80% values 4 2003/August

Pin Out Table Pin Name Pin# Sequence Sequence Pin# Pin Name RX_LOS 1 2 1 11 RGND RGND 2 2 1 12 -RX_DAT RGND 3 2 1 13 +RX_DAT MOD_DEF(0) 4 2 1 14 RGND MOD_DEF(1) 5 2 2 15 VDDR MOD_DEF(2) 6 2 2 16 VDDT TX_DISABLE 7 2 1 17 TGND TGND 8 2 1 18 +TX_DAT TGND 9 2 1 19 -TX_DAT TX_FAULT 10 2 1 20 TGND Overview of internal interface signal Definition Pin Name Pin # Name/Function Signal Specification Receiver Signals RGND 2,3,11,14 Receiver Ground (may be connected with TGND in GBIC) Ground, to GBIC VDDR 15 Receiver +5 volt (may be connected with VDDT in GBIC) Power, to GBIC -RX_DAT 12 Receive Data, Differential PECL +RX_DAT 13 Receive Data, Differential PECL RX_LOS 1 Transmitter Signals Receiver Loss of Signal, logic high, open collector compat-ible,4.7 K to 10 K Ohm pullup to VDDT on host High speed serial, from GBIC High speed serial, from GBIC Low speed, from GBIC TGND 8,9,17,20 Transmitter Ground (may be connected with RGND internally) Ground, to GBIC VDDT 16 Transmitter +5 volt (may be connected with VDDR in GBIC) Power, to GBIC +TX_DAT 18 Transmit Data, Differential PECL High speed serial, to GBIC -TX_DAT 19 Transmit Data, Differential PECL High speed serial, to GBIC TX_DISABLE 7 TX_FAULT 10 Control Signals MOD_DEF(0) 4 MOD_DEF(1) 5 MOD_DEF(2) 6 Transmitter Disable, logic high, open collector compatible,4.7 K to 10 K Ohm pullup to VDDT on GBIC Transmitter Fault, logic high, open collector compatible,4.7 K to 10 K Ohm pullup to VDDT on host Low speed, to GBIC Low speed, from GBIC GBIC module definition and presence, bit 0,4.7 K to 10 K Ohm Low speed, from GBIC pullup to VDDT on host GBIC module definition and presence, bit 1,4.7 K to 10 K Ohm Low speed, from GBIC pullup to VDDT on host GBIC module definition and presence, bit 2,4.7 K to 10 K Ohm Low speed, from GBIC pullup to VDDT on host 5 2003/August

Recommend Circuit Schematic GBIC-1250x3xx and x4xx Series Transceiver 6 2003/August

GBIC module definition parameters Module MOD_DEF(0) MOD_DEF(1) MOD_DEF(2) Definition Pin 4 Pin 5 Pin 6 Interpretation by host Reference 0 NC NC NC GBIC not present clause 1 NC NC TTL LOW Copper Style 1 or Style 2 connector, 1.0625 Gbd, 100-TW-EL-S or 100-TP-EL-S, active inter-enclosure connection and IEEE802.3 1000BASE-CX 2 NC TTL LOW NC Copper Style 1 or Style 2 connector, 1.0625 Gbd, 100-TW-EL-S, or 100-TP-EL-S, active or passive intra-enclosure connection 3 NC TTL LOW TTL LOW Optical LW, 1.0625 Gbd 100-SM-LC-L 4 TTL LOW SCL SDA Serial module definition protocol 5 TTL LOW NC TTL LOW Optical SW, 1.0625 Gbd 100-M5-SN-I or 100-M6-SN-I 6 TTL LOW TTL LOW NC Optical LW, 1.0625 Gbd 100-SM-LC-L and similar to 1.25 Gbd IEEE802.3z 1000BASE-LX, single mode 7 TTL LOW TTL LOW TTL LOW Optical SW, 1.0625 Gbd 100-M5-SN-I or 100-M6-SN-I and 1.25 Gbd, IEEE 802.3z, 1000BASE-SX GBIC timing parameters for GBIC management Parameter Symbol Min. Max. Unit Unit Conditions Rising edge of TX_DISABLE to fall of output signal TX_DISABLE assert time t_off 10 µsec below 10% of nominal TX_DISABLE negate Falling edge of TX_DISABLE to rise of output t_on 1 mec time signal above 90% of nominal Time to initialize, includes reset of TX_FAULT t_init From power on or hot plug fter V DD T > 4.75 volts 300 msec or From negation of TX_DISABLE during reset of TX_FAULT. TX_FAULT from fault to From occurrence of fault (out-put safety violation or t_fault 100 µsec assertion V DD T < 4.5 volts) TX_DISABLE time to start reset t_rest 10 µsec TX_DISABLE HIGH before TX_DISABLE set LOW From detection of loss of signal to assertion of RX_LOS assert delay t_loss_on 100 µsec RX_LOS From detection of presence of signal to negation of RX_LOS negate delay t_loss_off 100 µsec RX_LOS 7 2003/August

GBIC timing parameters 8 2003/August

GBIC-1250A3FS EEPROM Serial ID Memory Contents (2-Wire Address A0h) Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII 00 01 25 20 50 33 3 75 SN 100 00 125 00 01 04 26 20 51 46 F 76 SN 101 00 126 00 02 01 27 20 52 53 S 77 SN 102 00 127 00 03 00 28 20 53 20 78 SN 103 00 04 00 29 20 54 20 79 SN 104 00 05 00 30 20 55 20 80 SN 105 00 06 01 31 20 56 30 81 SN 106 00 07 20 32 20 57 30 82 SN 107 00 08 40 33 20 58 30 83 SN 108 00 09 0C 34 20 59 30 84 DC Note 3 109 00 10 01 35 20 60 00 85 DC 110 00 11 01 36 00 61 00 86 DC 111 00 12 0D 37 00 62 00 87 DC 112 00 13 00 38 00 63 CB Note 1 88 DC 113 00 14 00 39 00 64 00 89 DC 114 00 15 00 40 47 G 65 1A 90 DC 115 00 16 32 41 42 B 66 00 91 DC 116 00 17 16 42 49 I 67 00 92 00 117 00 18 00 43 43 C 68 SN Note 2 93 00 118 00 19 00 44 2D - 69 SN 94 00 119 00 20 44 D 45 31 1 70 SN 95 CS2 Note 4 120 00 21 45 E 46 32 2 71 SN 96 00 121 00 22 4C L 47 35 5 72 SN 97 00 122 00 23 54 T 48 30 0 73 SN 98 00 123 00 24 41 A 49 41 A 74 SN 99 00 124 00 GBIC-1250A4FS EEPROM Serial ID Memory Contents (2-Wire Address A0h) Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII 00 01 25 20 50 34 4 75 SN 100 00 125 00 01 04 26 20 51 46 F 76 SN 101 00 126 00 02 01 27 20 52 53 S 77 SN 102 00 127 00 03 00 28 20 53 20 78 SN 103 00 04 00 29 20 54 20 79 SN 104 00 05 00 30 20 55 20 80 SN 105 00 06 01 31 20 56 30 81 SN 106 00 07 20 32 20 57 30 82 SN 107 00 08 40 33 20 58 30 83 SN 108 00 09 0C 34 20 59 30 84 DC Note 3 109 00 10 01 35 20 60 00 85 DC 110 00 11 01 36 00 61 00 86 DC 111 00 12 0D 37 00 62 00 87 DC 112 00 13 00 38 00 63 CC Note 1 88 DC 113 00 14 00 39 00 64 00 89 DC 114 00 15 00 40 47 G 65 1A 90 DC 115 00 16 32 41 42 B 66 00 91 DC 116 00 17 16 42 49 I 67 00 92 00 117 00 18 00 43 43 C 68 SN Note 2 93 00 118 00 19 00 44 2D - 69 SN 94 00 119 00 20 44 D 45 31 1 70 SN 95 CS2 Note 4 120 00 21 45 E 46 32 2 71 SN 96 00 121 00 22 4C L 47 35 5 72 SN 97 00 122 00 23 54 T 48 30 0 73 SN 98 00 123 00 24 41 A 49 41 A 74 SN 99 00 124 00 Notes: 1) Byte 63: Check sum of bytes 0-62. 2) Byte 68-83 (SN): Serial number. 3) Byte 84-91 (DC): Date code. 4) Byte 95 (CS2): Check sum of bytes 64-94. 9 2003/August

GBICP-1250B3QS EEPROM Serial ID Memory Contents (2-Wire Address A0h) Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII 00 01 25 20 50 33 3 75 SN 100 00 125 00 01 04 26 20 51 51 Q 76 SN 101 00 126 00 02 01 27 20 52 53 S 77 SN 102 00 127 00 03 00 28 20 53 20 78 SN 103 00 04 00 29 20 54 20 79 SN 104 00 05 00 30 20 55 20 80 SN 105 00 06 02 31 20 56 30 81 SN 106 00 07 12 32 20 57 30 82 SN 107 00 08 00 33 20 58 30 83 SN 108 00 09 01 34 20 59 30 84 DC Note 3 109 00 10 01 35 20 60 00 85 DC 110 00 11 01 36 00 61 00 86 DC 111 00 12 0D 37 00 62 00 87 DC 112 00 13 00 38 00 63 09 Note 1 88 DC 113 00 14 00 39 00 64 00 89 DC 114 00 15 64 40 47 G 65 1A 90 DC 115 00 16 37 41 42 B 66 00 91 DC 116 00 17 37 42 49 I 67 00 92 00 117 00 18 00 43 43 C 68 SN Note 2 93 00 118 00 19 00 44 2D - 69 SN 94 00 119 00 20 44 D 45 31 1 70 SN 95 CS2 Note 4 120 00 21 45 E 46 32 2 71 SN 96 00 121 00 22 4C L 47 35 5 72 SN 97 00 122 00 23 54 T 48 30 0 73 SN 98 00 123 00 24 41 A 49 42 B 74 SN 99 00 124 00 GBIC-1250B4QS EEPROM Serial ID Memory Contents (2-Wire Address A0h) Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII 00 01 25 20 50 34 4 75 SN 100 00 125 00 01 04 26 20 51 51 Q 76 SN 101 00 126 00 02 01 27 20 52 53 S 77 SN 102 00 127 00 03 00 28 20 53 20 78 SN 103 00 04 00 29 20 54 20 79 SN 104 00 05 00 30 20 55 20 80 SN 105 00 06 02 31 20 56 30 81 SN 106 00 07 12 32 20 57 30 82 SN 107 00 08 00 33 20 58 30 83 SN 108 00 09 01 34 20 59 30 84 DC Note 3 109 00 10 01 35 20 60 00 85 DC 110 00 11 01 36 00 61 00 Note 1 86 DC 111 00 12 0D 37 00 62 00 87 DC 112 00 13 00 38 00 63 0A 88 DC 113 00 14 00 39 00 64 00 89 DC 114 00 15 64 40 47 G 65 1A 90 DC 115 00 16 37 41 42 B 66 00 91 DC 116 00 17 37 42 49 I 67 00 92 00 117 00 18 00 43 43 C 68 SN Note 2 93 00 118 00 19 00 44 2D - 69 SN 94 00 119 00 20 44 D 45 31 1 70 SN 95 CS2 Note 4 120 00 21 45 E 46 32 2 71 SN 96 00 121 00 22 4C L 47 35 5 72 SN 97 00 122 00 23 54 T 48 30 0 73 SN 98 00 123 00 24 41 A 49 42 B 74 SN 99 00 124 00 Notes: 1) Byte 63: Check sum of bytes 0-62. 2) Byte 68-83 (SN): Serial number. 3) Byte 84-91 (DC): Date code. 4) Byte 95 (CS2): Check sum of bytes 64-94. 10 2003/August

Package Outline Drawing Regulatory Compliance Test Item Reference Qty Evaluation (#1) Electromagnetic Interference EMC (#2) Immunity: Radio Frequency Electromagnetic Field (#3) Immunity: Electrostatic Discharge to the Duplex SC Receptacle (#4) Electrostatic Discharge to the Electrical Pins FCC Class B EN 55022 Class B CISPR 22 EN 61000-4-3 IEC 1000-4-3 EN 61000-4-2 IEC 1000-4-2 IEC 801.2 MIL-STD-883C Method 3015.4 EIAJ#1988.3.2B Version 2, Machine model 5 5 5 5 (1) Satisfied with electrical characteristics of product spec. (2) No physical damage 11 2003/August

Ordering information for GBIC modules GBIC-1250x3xx and x4xx Series Transceiver GBIC-1250X 1 X 2 X 3 X 4 X1: Fiber types A: Multi-mode Fiber B: Single-mode Fiber X2: Power Supply Voltage 3: 5V 4: 3.3V 5: 3.3/5V X3: Distance F: 500m (Multi-mode Fiber) Q: 10km (Single-mode Fiber) L: 25km M: 40km X4: S: Standard part Others: customized parts Available Products GBIC-1250A3FS: Single supply voltage (5V), 850nm VCSEL, 50um MMF 500m. GBIC-1250B3QS: Single supply voltage (5V), 1310nm MQW FP LD, SMF 10km. GBIC-1250A4FS: Single supply voltage (3.3V), 850nm VCSEL, 50um MMF 500m. GBIC-1250B4QS: Single supply voltage (3.3V), 1310nm MQW FP LD, SMF 10km. GBIC-1250A5FS: Dual supply voltage (3.3/5V), 850nm VCSEL, 50um MMF 500m. GBIC-1250B5QS: Dual supply voltage (3.3/5V), 1310nm MQW FP LD, SMF 10km. GBIC-1250B5LS: Dual supply voltage (3.3/5V), 1310nm DFB-LD, SMF 25km. GBIC-1250B5MS: Dual supply voltage (3.3/5V), 1550nm DFB-LD, SMF 40km. 12 2003/August