LK Electric Boiler - 4,5



Similar documents
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Overheating limit control

Description of functions

Laddomat Charging unit

Installation and maintenance instructions. Danfoss Vent

Technical data. Danfoss DHP-A

ELECTRIC CENTRAL HEATING FLOW BOILER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Electric Flow Boiler

Operators manual Basic water heater

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

SF15K SF05KSS, SF10KSS

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

For installation guide see reverse of book

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Operating instructions

Drayton Digistat +2RF/+3RF

Aquamax Australia Pty Ltd ABN

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Product and functional description

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

TMS TANK MANAGEMENT SYSTEM

V94 BULK TAPE DEGAUSSER

INSTALLATION & TECHNICAL MANUAL

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

ECOCIAT. Domestic hot water heat recovery unit

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Cooling system components, removing and installing

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Air Source Heat Pump Installation and Maintenance Manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

ELECTRIC INSTANTANEOUS WATER HEATER

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Series description: Wilo-Star-Z

STERILIZERS, LABORATORY DRYING OVENS

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Conlift1, Conlift2, Conlift2 ph+

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Please also see 10 golden rules for correct Saniflo installation on

Heating, air-conditioning, cooling

BERMAD Fire Protection

SunMaxx Solar Filling Station Operating Instructions

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

TIG INVERTER INSTRUCTION MANUAL

Portable Air Conditioner

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Cooling system components, removing and installing

Stove Guard Kit User Manual

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

PD 100A. Printing data system


with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

RRV934. Multi-controller. Synco living

User's Instructions. Alpha HE CB25/33 and HE SY25

DALI RC BASIC SO. Control unit Operating instructions

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

HEAVY DUTY STORAGE GAS

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

User Manual THR840DUK Digital Thermostat

This section gives you some helpful information and tips on running your home and the equipment in it.

Servicing manual. Gas wall hung boiler condensing 600 Series - 11S / 19S / 24S / 24C /2006 GB(EN) For trade use

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HERZ-Thermal Actuators

INFRARED QUARTZ WALL HEATER

Aerona Air Source Heat Pumps

Topvex SX/C, Topvex TX/C. Air Handling Unit

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

HeatSource HS1800 Heater

ACS-30-EU-EMDR-10-MOD

Transcription:

LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered as a complete unit. The boiler is ready for use once the water and electricity are connected. The boiler includes: Thermostat Overheating (maximum safe temperature) protection Indication power on and triggered overheating (maximum safe temperature) protection Control switch Circulation pump, Grundfos UPM, - Expansion vessel Pressure gauge Thermometer Safety valve,, bar Automatic air bleeding valve Bypass valve The electric boiler is not fitted with a water heater, this is installed separately. Function/Requirements The boiler output meets the heat requirements for up to 9 m² of living space, depending on the insulation and ventilation. Depending on the connection the boiler can supply,,,, or, kw. The boiler is controlled by an in-built thermostat. If necessary, the boiler can also be controlled by an external thermostat, for more information please refer to the heading External switching/room thermostat. Assembly The boiler is mounted to the wall, or in a cabinet. The boiler dimensions x 7 x mm (W x H x D) mean that it can be installed in most kitchen cabinets. Pipe installation Installation should be carried out according to the applicable regulations and standards. The boiler should be assembled indoors, mounted to a wall or similar with the pipe connections underneath. The ambient temperature must not exceed C. The gap between the underside of the boiler and the surface beneath it must be at least mm to enable electric cartridges to be replaced, if necessary. Hard, calciferous water is not suitable for use with this heating system. To avoid corrosion damage the ph value should not be too low. The blow-off pipe from the electric boiler safety valve flows into a drip tray in the boiler cabinet. The installation inspection should be carried out according to the applicable regulations on a unit with a sealed expansion vessel, before the unit is operated. The inspection should be conducted by a suitably qualified person. The replacement of parts and the expansion vessel must not occur without a repeat inspection of the installation. A counter torque wrench should be used during connection to avoid damaging the internal piping.

Installation - system outline Below is a system outline. Units should always be installed according to regulations and standards. When the system is filled with water it should be air-bled at the electric boiler and the manifolds. Flow - circulation pump The flow must be secured. The boiler requires a flow which produces a maximum Δt of C (The temperature difference between the boiler s flow pipe and return).. LK Electric Boiler -,. Filling valve/drain valve. Manifolds under floor heating. Under floor heating system Expansion vessel Expansion vessel: litres, delivery pre-pressure, bar. The vessel supplies a heating system volume of 7 litres at 6 C and a static pressure of metres. At lower static heights or temperatures the vessel supplies a greater volume. If glycol mix is used the capacity of the expansion vessel is reduced in relation to the amount of glycol mixed. Connection output (kw) Recommended flow (litres/min),,,,,,, 6, The diagram shows the maximum permissible pressure drop in the heating system for the capacity of the circulation pump to produce a Δt of C at the maximum pump speed, with the dial positioned at III. (kpa) Pressure resistance 6 8 Flow (l/min) Bypass valve The circulation pump may be damaged if operated if it is applied to closed valves. The bypass valve reduces this risk. With the pump at maximum speed, position III, the adjustment valve should be open by at least half a revolution. Safety valve The safety valve,, bar, is mounted to the boiler, the blow-off pipe flows into a drip pan in the boiler cabinet. Filling - air bleeding The heating system should be filled with water up to a pressure higher than the pre-pressure of the expansion vessel,, bar. bar is recommended.. Isolation valve supply and return. By-pass valve, accessible after the protective plug has been unscrewed.

Pipe installation Circulation pump Delivery setting: Constant pressure curve. If parts of the heating system do not get hot, this can be changed to Constant pressure curve. Selecting a higher curve increases energy consumption and operating costs. Push button LEDs In operating mode, the first LED lights up green, and between one and four LEDs light up yellow. The yellow LEDs indicate the operating capacity of the pump. - % - % - 7 % 7 - % Pressing the button displays the pump setting for sec before the pump returns to normal display. PROP. PRESSURE: CURVE PROP. PRESSURE: CURVE PROP. PRESSURE: CURVE If the button is depressed for sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of curves can be selected by turning the button. When the button has been released for sec, the pump returns to operating mode, the LEDs stop flashing and the selected curve becomes active. A lit red LED indicates an alarm or warning. Indication Fault Status Measure Motor blocked Red + fourth yellow Red + third yellow Red + second yellow Low voltage Electrical fault Pump tries to restart at. sec intervals Warning only, pump continues to operate Pump stopped Release motor/ impeller or wait Check voltage to pump Check voltage/replace pump A button lock prevents accidental adjustments to the pump settings. The button can be locked/unlocked by depressing the button for seconds. After seconds, all the LEDs will flash quickly to indicate that the lock is locked/unlocked. Pump capacity p [kpa] H [m] CONST. PRESSURE: CURVE CONST. PRESSURE: CURVE CONST. PRESSURE: CURVE CONST. CURVE: KURVA CONST. CURVE: KURVA CONST. CURVE: KURVA CONST. CURVE: KURVA....6.8....6.8....6.8 Q [m³/h]. P......6.7.8 Q [l/s] [W]....6.8....6.8....6.8 Q [m³/h]

Electric installation Electric installation should be carried out in accordance with the applicable regulations, under the supervision of an authorized electrician., kw / V~ / 6, A P X N N L L L The boiler must not be connected to the electrical supply before it is filled with water. The boiler should be preceded by all-pole circuit switches. The ambient temperature must not exceed C. Feeding Feed cable: x, mm² Protection fuse: A Jumper: N-X, kw / V N~ /,6 A P X N N L L L Feed cable: x, mm² Protection fuse: x A, kw / V N~ / 7, A P X N N L L L Feed cable: x, mm² Protection fuse: x A Jumper: N-X The boiler works with two outputs,, och kw.. Connection terminal. Electric shock protection. Knock-out hole (cabling from wall). Cable bushes With a single or two phase connection not all of the boiler s main fuses are stressed. Other large current consumers should therefore be connected to the phase lines which are not stressed by the boiler. Alternative connections The boiler is connected according to (some of) the alternatives below, depending on the desired output., kw / V N~ / 6, A P X N N L L L Feed cable: x, mm² Protection fuse: x A The boiler works with two outputs,, och, kw. At, kw only phases L and L (,6A) are stressed. Note! Intervention in the boiler which requires tools may only be carried out under the supervision of an authorized installer!

External switching/room thermostat The boiler can be blocked by external equipment, e.g. room thermostat, with potential-free contact. Connection is carried out at terminals & on the boiler connection terminal. P X N N L L L Wiring diagram, kw / V N~ / 6, A Feed cable: x, mm² Protection fuse: x A The boiler operates in two power steps,, and, kw. At, kw, only phases L and L (, 6 A) are loaded. 6 8 C T - 6 C T 7 L T 8. kw. Alarm indication, overheating (maximum safe temperature) protection triggered. On/off indicating light, goes on when voltage is supplied to the boiler. Contacts Alternative connection, kw / V ~ /, A Output, kw / V ~ /, A Feed cable: x, mm² Protection fuse: x 6 A Move jumper from terminal X-N to N-L. Disconnect neutral wire to electric heating element. Enclosed D-cable is connected as shown in wiring diagram below. ALARM OPERATION ELECTRIC CARTRIDGE D-CONNECTED RECONNECT DISCONNECT L T 9 N N L T L T A ALARM N A OPERATION N N MOVE N Alternative connection,, kw / V ~ /, A P X N N L L L Execution upon delivery,, kw / V N~ / 6, A, kw / V ~ / 9,6 A Feed cable: x mm² Protection fuse: A. External switching. Jumper, for, and kw connection. Connection terminal. Suppressor capacitor. Circulation pump 6. Overheating (maximum safe temperature) protection 7. Thermostat 8. Electric cartridge 9. Control switches

Mount DIN-rail, -pole terminal block with end plate, and connect cables supplied as shown in wiring diagram below. Operation and maintenance 6 bar C 8 Min., Bar Max, Bar ALARM OPERATION 7 6 6 Tillse att pannan är vattenfylld innan den startas Boiler must be filled with water before start LK Systems Alternative connection,, kw / V ~ / 9,6 A Control panel. Thermometer. Manometer. Resetting overheating (maximum safe temperature) protection. Thermostat/temperature setting. Control switches 6. On/off indicating light, goes on when voltages is supplied to the boiler 7. Indication, overheating (maximum safe temperature) protection triggered Inspect, together with installer, after the installation, that the unit is in a satisfactory condition. Have the installer demonstrate how the unit works, and should be handled. The boiler and the heating system must be filled with water before the circuit switch is set to on. The boiler cover should be assembled during operation. 6

Note! Monitor the amount of water in the vessel, which accrues waste water from the safety valve, regularly. This is important in a new system! Temperature setting Set the thermostat to a suitable temperature. The maximum temperature for concrete floor joists is approx. - C and for wooden joists approx. - C. The desired temperature varies according to the time of year. Safety valve The safety valve should be exercised regularly to maintain the safety function. Overheating (maximum safe temperature) protection The overheating (maximum safe temperature) protection on the boiler is triggered when the boiler temperature exceeds 8. The protection is restored on the control panel, when the boiler temperature has fallen below 6 C. Inform the installer! When resetting push overheat protection button hard with a sharp object. Note! Always check the reason to overheating! Thermometer The thermometer shows the boiler s feed temperature. Air bleeding Air may remain in the system for some time after installation, which is the why water may need to be replenished. Measures to counter the risk of freezing If the unit should be switched off for longer periods of time care should be taken that it does not freeze. All of the water in the unit must be drained out if there is a risk of freezing, and the power supply to the boiler should be switched off. Alternatively, the heating system can be filled with an appropriate amount of anti-freeze. The boiler must not be in operation if any part of the heating system is suspected of being frozen. Inform the installer! Draining Before the water is drained out of the system the electric boiler should be switched off. Always switch off the power to the boiler before: Water is drained out Intervention or maintenance work is carried out inside the boiler, or any other units supplied with electricity from the boiler Expansion vessel The pre-pressure of the expansion vessel should be inspected annually, see the data plate attached to the vessel. Water pressure in the system The boiler cover must be removed in order to check the water pressure. The pressure gauge shows the pressure in the heating system. Check regularly that there is sufficient water in the system. The pressure gauge should display, -, bar. The water volume changes with the temperature, which in turn affects the pressure. The higher the temperature, the greater the volume and pressure. The expansion vessel gathers changes in the volume. Check the water pressure in the system regularly! 7

Troubleshooting Intervention in the boiler which requires the use of tools should be carried out by an authorized electrician. Begin all troubleshooting tasks by looking at the status indicators, see the Control panel section. Error Possible cause Measures On/off indication The electric boiler is currentless. Check the fuses. is off, there is no Circuits switched off. Check that the main and control switches are on. heat in the heating system. The electric boiler is blocked externally. Check if the boiler is blocked by external switching/room thermostat. Alarm light is on. Overheating (maximum safe temperature) protection is triggered. If the overheating (maximum safe temperature) protection goes off, the function should be controlled at the circulation pump and valves. During resetting the button on the overheating (maximum safe temperature) protection is pushed in when the boiler temperature falls below 6 C (push the button hard for reset). No or insufficient heat. Group fuses for boiler are triggered. Thermostatic valves on the heating system or boiler thermostat set at too low temperature. Faulty adjustment of bypass valve. The electric cartridge is broken. Inspect and adjust. Inspect and adjust. Inspect the electric cartridge by testing it in isolation. Measure between the outward side on the contacts, and earth. Inform the installer! Intervention in the boiler, which requires the use of tools, must only be carried out under the supervision of an authorized installer! Drawings 7 6. Cable bushes. Automatic bleeding valve. Expansion vessel. Sensor clip, thermometer bulb. Boiler vessel of stainless steel with electric cartridge, insulated 6. Circulation pump 7. Electric-shock protection over electric cartridge cable connections 8. Bypass with shut-off valves 9. Flow pipe, ¾ male thread. Return connection, ¾ male thread. Collection vessel, waster water from safety valve. Safety valve. Electric-shock protection. Knockouts for cables, where these come from the wall 8 9 8

Dimensional drawings 6 7 9 7 89 Technical data Article no. 6 Height Width Depth Weight Output Voltage Current 7 mm mm mm 7 kg, kw V N~, Hz 6, A Protection Class IP Output circulation pump Volume Volume expansion vessel Calculation pressure Test pressure Safety valve - W, litres litres, bar,6 bar, bar Calculation temperature 8 C Control temperature Manufactured in accordance with: Fuse -6 C AFS 999: 8 97/ EG article x A Without cover Condensing boiler no Low-temperature no B boiler no Cogeneration space heater no Combination heater no Rated heat output P rated kw Useful heat output at rated P, kw heat output Energy class D Seasonal space heating energy efficiency boiler boiler with η s η s 6 8 % % UTK Useful efficiency η 9,7 % Auxiliary electricity consumption in standby mode P SB,9 kw Standby heat loss P stby,7 kw 7 Material recycling After dismantling the boiler must be recycled. The insulation is removed and recycled as insulation. Boiler Body recycled as scrap steel. Electrical and electronic components are sorted as electronic waste. Boiler casing recycled as plastic. With cover 9