CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS



Similar documents
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

ASX7-4-IOM-7 J

Fuels Safety Program FS DIRECTOR S PUBLIC SAFETY ORDER

MODELS WATER HEATER VENT PACKAGE. For Natural Gas or LP

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

HVAC Code Requirements

CHAPTER 5 WATER HEATERS

Arapahoe County Residential Water Heater Installation and Inspection Guide

Cooktop Low-Profile Ventilation Hoods

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Your safety and the safety of others are very important.

Installation & Operation Manual Models: ER152, ER202, ER252, ER302, and ER402

2010 Residential Water Heater Replacement Check List

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

CARING FOR YOUR WATER HEATER

Installation Operation & Maintenance Manual

3 IN 1 BATHROOM HEATER

NAVIEN AMERICA INC FITCH AVENUE

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

DRYER VENTING SPECIFICATIONS DRYER SAFETY

AUTO-DRAFT INDUCER INSTALLATION INSTRUCTIONS MODELS D-3 XL


Gas-Fired, Residential Storage Type Water Heaters

Installation Instructions

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Amendment: Combustion Appliance Testing Standards Removal. Proponent: Brett Dillon, Chair Standards Development Committee

Contents. Hazard definitions

SL280UHV SERIES GAS FURNACE WARNING

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Attachment #23 Health Safety Table. Client Education Inform issue and document. How to clean & maintain gutters. How to adjust sprinklers

Exhaust Calculation Booklet

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Installation and Service Instructions LoganoUS/CA GC 144 II

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

G670 Intermittent Pilot Ignition Controls

Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, USA. Venting Guide

Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

GAS SAFETY PRECAUTIONS

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

HEAT WAVE DUCT KIT KIT #

INSTALLATION INSTRUCTIONS

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

1 DESCRIPTION OF THE APPLIANCE

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ANSI/BPI-1200-S-2015:

Air Conditioning Sign-Off Sheet

D248 Series Cast Iron Commercial Steam Boiler

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Thermo Top - Troubleshooting Tree

Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Crawford Inspection Services C.C.B. #

XL PREMIUM OIL COOLER KIT

Cooling Capacity CFM in. w.c. (125 Pa)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Home inspectors are not mold inspectors, however they do inspect for defects that

User's Instructions. Alpha HE CB25/33 and HE SY25


PLP - TERMS AND CONDITIONS

Installation Instructions ERV/PRV Downdraft Vent

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Tankless Water Heater

High efficiency, cast-iron gas boiler

Troubleshooting Draft Problems in Chimneys

Baxi Combi 80e & 105e

DESIGNER S GUIDE EFFICIENCY+ BOILER

Fundamentals of Venting and Ventilation

Service Handbook Commercial / Residential gas water heater

Oil - kerosene burners

Munchkin Heat Exchanger Maintenance

Boiler and Burner Cleaning and Servicing Specifications

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Boiler Installation and Maintenance Manual

Orlando Home Inspection Services

prestige Water Boiler * I N S T A L L A T I O N A N D M A I N T E N A N C E * M A N U A L

Boiler Plan II Table of Contents

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Guidelines for Earthquake Bracing Residential Water Heaters

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

HV AC CODE CHECKLISTS

Home Maintenance Checklist

GENUINE PARTS INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

READ AND SAVE THESE INSTRUCTIONS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

NFPA31FuelOilPiping 1 Revised

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Transcription:

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause property damage, injury, or loss of life. For assistance or additional information, consult a qualified installer, service agency, or the gas supplier. I Product Description The BWF Category I vent kit is used to vent the BWF series boiler into a Category I ( Chimney ) vent system. This kit consists of a special box-shaped adapter which is used to connect single wall smoke pipe or B vent to the fan discharge of a BWF boiler. This adapter is equipped with a spill switch designed to shut down the burners and fan in the event of a vent blockage. When connected to a properly sized and constructed vent system, all parts of the vent system, including the adapter box, are under negative pressure. II Before Installing 1) Read the installation instructions provided with the boiler. The instructions provided with the boiler cover all aspects of the boiler installation except for venting. These instructions cover the installation of the Category I vent kit and connection of the boiler to a Category I vent system. 2) Vent installation must be in accordance with the latest edition of the National Fuel Gas Code (NFPA54/ANSI Z223.1) and all applicable local codes: Make sure that the boiler can be vented using a suitable chimney in accordance with all applicable codes. In the context of the National Fuel Gas Code, the BWF is classified as a Category I fan-assisted appliance only when this kit is installed. When this kit is not installed, the BWF is classified as a Category III appliance and must be vented using one of the stainless steel special vent systems shown in the installation manual. Make sure that you have the correct vent kit for the size boiler being installed: BWF061 - BWF128: Crown #650140 (equipped with 5 collar) BWF162 - BWF-229: Crown #650141 (equipped with 6 collar) III Vent Kit Installation 1) Screw the four 10-32 studs supplied into the fan flange 2) Verify that the boiler model number marked on the outlet orifice matches that of the boiler being installed (see Fig. 1). 3) Slip a gasket, the outlet orifice, and the second gasket over the studs as shown in Figure 1. 4) Install the adapter box over the studs with the spill switch facing the right side of the boiler. Secure with the 10-32 nuts and washers provided. 5) Route the wire harness from the spill switch into the boiler vestibule through knockout A shown in Figure 1. 6) Locate the 3/16 male/female quick-connect in the orange wire leading from the high limit. This quick-connect is located near the right side of the vestibule where the conduit from the high limit enters the vestibule (Figure 2). 7) Unplug this quick connect. 8) Plug the spill switch harness into quick connects opened in Step 7 (also see connection and ladder diagrams). 9) Boiler is now ready to be connected to the vent system. 1 PN 980490 Rev. 0

2

IV Vent System Installation Figure 3 shows a typical BWF Category I vent system. The major components of this system are the adapter box, the vent connector, and the chimney. 1) Acceptable Chimneys - The following chimneys may be used to vent BWF series boilers: Listed Type B or L gas vent - Install in accordance with the manufacturer s instructions, the terms of its listing, and applicable codes. Masonry Chimney (lined with a listed metal lining system) - Install in accordance with the liner manufacturer s instructions, the terms of the liner s listing, and applicable codes. Masonry Chimney (lined with a ceramic liner) - In many cases, the National Fuel Gas Code does not permit installation of fan assisted appliances such as the BWF into clay lined masonry chimneys. Consult the National Fuel Gas Code before attempting to connect a BWF series boiler into a ceramic lined masonry chimney. 2) Acceptable Vent Connectors - The following may be used for vent connectors: Listed type B or L Gas Vent Single Wall Galvanized Pipe - Use 0.018 (26 gauge or heavier). The size and location of the chimney may not permit the use of a single wall connector in some cases. See Chapter 10 of the National Fuel Gas Code. Do not use single wall pipe for vent connectors in attics. Other Vent Connectors Permitted by the National Fuel Gas Code. 3) Chimney and Vent Connector Sizing - Size the chimney and vent connector in accordance with the National Fuel Gas Code. 4) Exterior Chimneys - An exterior chimney has one or more sides exposed to the outdoors below the roof line. There are two conditions under which an exterior chimney may be used: In some very restrictive cases, the BWF series boiler may be vented into an exterior ceramic lined masonry chimney. See the National Fuel Gas Code for information on when exterior ceramic lined chimneys may be used. An exterior masonry chimney may be used if it is lined with B vent or a listed chimney lining system. 5) Do not connect the vent of this appliance into any portion of a mechanical vent system operating under positive pressure. 6) Do not connect the boiler into a chimney flue serving an open fireplace or other solid fuel appliance. 7) Prior to boiler installation, inspect chimney for obstructions or other defects and correct as required. Clean chimney as necessary. 8) Vent connector should slope upward from the vent adapter box not less than 1/4 inch per foot. No portion of the vent connector should run downward or have sags. All vent piping must be securely supported. 9) The vertical section of the vent pipe coming off the boiler should be as tall as possible, while still maintaining the proper clearance from the horizontal vent connector to combustibles and the proper pitch called for in (9) above. 10) Vent connector should be installed above the bottom of the chimney to prevent blockage. 11) Vent connector must be inserted flush with inside face of the chimney liner and the space between vent pipe and chimney sealed tight. 3

IV Removing an Existing Boiler from a Common Chimney In some cases, when an existing boiler is removed from a common chimney, the common venting system may be too large for the remaining appliances. At the time of removal of an existing boiler, the following steps shall be followed with each appliance remaining connected to the common venting system placed in operation, while the other appliances remaining connected to the common venting system are not in operation. a) Seal any unused opening in the common venting system. b) Visually inspect the venting system for proper size and horizontal pitch and determine there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition. c) Insofar as practical, close all building doors and windows and all doors between the space in which all the appliances remaining connected to the common venting system are located and other spaces of the building. Turn on clothes dryers and any appliance not connected to the common venting system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers. d) Place in operation the appliance being inspected. Follow the lighting instructions. Adjust thermostat so the appliance will operate continuously. e) Test for spillage at the draft hood relief opening after five (5) minutes of main burner operation. Use the flame of a match or candle, or smoke from a cigarette, cigar, or pipe. f) After it has been determined that each appliance remaining connected to the common venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas-burning appliances to their previous condition of use. g) Any improper operation of the common venting system should be corrected so the installation conforms with the National Fuel Gas Code, ANSI Z223.1. When resizing any portion of the common venting system, the common venting system should be resized to approach the minimum size as determined using the appropriate tables in Part 10 of the National Fuel Gas Code, ANSI Z223.1. 4

V Service and Maintenance Perform all service and maintenance shown in the BWF installation manual. In addition, inspect the adapter box and vent system for the following: Blockages (including blockages in the blocked vent switch spillway) Corrosion or other deterioration Missing or loose supports If the blocked vent switch opens, both the burners and fan will shut down. In order to restart the boiler, it will be necessary to push the red reset button on the top of the spill switch. WARNING A shutdown of the boiler due to the blocked vent switch is an indication that there is a problem with the vent system, such as a blockage Reset the switch only after a qualified heating technician has diagnosed and corrected the venting problem that caused the switch to open. Do not replace the blocked vent switch with any other switch not specifically approved by Crown Boiler Company for use on this vent kit. 5

VI Parts (See Figure 1 for Illustrations) KIT PART # KIT PART # 650140 650141 DESCRIPTION QTY. OR USED WITH USED WITH CROWN P.N. BWF061 - BWF128 BWF162 - BWF229 ADAPTER BOX (5" COLLAR) 650145 1 ea. ADAPTER BOX (6" COLLAR) 650146 1 ea. BLOCKED VENT SWITCH 960650 1 ea. 1 ea. B.V.S. HARNESS 960651 1 ea. 1 ea. CABLE CLAMP 960655 1 ea. 1 ea. #10 X 1/2 SHEET METAL SCREW 90-212 2 ea. 2 ea. 10-32 X 1" STUD 900229 4 ea. 4 ea. 10-32 NUT 90-219A 4 ea. 4 ea. #10 FLAT WASHER 90-057 4 ea. 4 ea. 6