Seccua Product Presentation

Similar documents
Innovation and Progress in Water Treatment Technology

MEMCOR membranes for drinking water applications. Water Technologies

HUBER Vacuum Rotation Membrane VRM Bioreactor

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

The use of ultrafiltration in the public drinking water supply in Germany

Case Study: Research Leads To Large-Scale Microfiltration Plants 10/01/1999

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Municipal Standard Solutions. Water Treatment WATER TECHNOLOGIES

Complete. Water Solutions. for Rural India

Indiana s Newest Filtration Facility; East Chicago

Life Sciences USD High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs

Pall Aria AP Series Packaged Water Treatment Systems

Water Treatment and Reverse Osmosis Systems

Craig L. Patterson, P.E. Water Supply and Water Resources Division National Risk Management Research Laboratory Cincinnati, Ohio 45268

Water Water Treatment Plant Tour

Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters

BROADFIELD SECURITY SERVICES WATER FILTRATION AND PURIFICATION SOLUTIONS

inge watertechnologies AG Innovative Ultrafiltration technology Josef Wunram

Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

for Sediment Removal desired levels. The filtered water then can be chemically treated to ensure its safety. Municipal water Preliminary settling

Water Purification Solutions

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

Water Equipment Technologies. Advanced Membrane Technologies for Solving Worldwide Water Problems

Sigma. Groundbreaking multi-screen polymeric, self-cleaning filter for irrigation

INTEGRATED MEMBRANE SYSTEMS. Introduction

To meet the demands of a high-purity deionized (DI) water system, filters must:

Emergency Drinking Water Supply

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper

How To Water System

Basics of UV Disinfection

DOMESTIC WASTEWATER SYSTEMS

Power consumption (kw)

Application Note NEW LOGIC RESEARCH. Treating Fuel Storage Tank Bottom Water With VSEP. Overview

Guidelines for Four-Log Virus Treatment of Ground Water Drinking Water Section Florida Department of Environmental Protection October 2009

Highly Colored Water Removal Using Nanofiltration Membranes at the Colored Water Treatment Facility. Adam Zacheis, Project Manager Carollo Engineers

SOLAR WATER PURIFICATION WITH THE HELP OF CSP TECHNOLOGY

Filtration Solutions for Water Production.

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel Fax

Drinking water for Gaza Elaboration concept 2

EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME. David Aitken. Earth Tech Engineering

The RWO Ballast Water Treatment System

Evaluation of Alternatives to Domestic Ion Exchange Water Softeners. Mara Wiest Dr. Peter Fox Dr. Lee Wontae, HDR Tim Thomure, HDR

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

Water... The essence of life

Watts Family of water quality improvement products and equipment for whole house water treatment.

KİMYA SANAYİ VE DI TİC.LTD. Tİ.

SECTION 11 drinking Water Systems

RiOs 3, 5, 8 Water Purification Systems

CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS APPLICATION INSTRUCTIONS

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Wastewater Reuse. Typical treated wastewater is:

Iron and Manganese BACTERIA AND IRON AND MANGANESE

Producing Safe Drinking Water: Ultra-filtration Membrane for the Removal of Indicator Bacteria

A meaningful, cost-effective solution for polishing reverse osmosis permeate

Advanced Water Treatment and Membrane Technology in Japan

RO Reverse Osmosis equipments

Water Treatment & Purification Chemicals

Mine Water Treatment Solutions for Discharge and Re-Use

Membrane filtration of surface water for the removal of humic substances

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

Coagulation and Flocculation in Water and Wastewater Treatment

1. Inspection and monitoring... 3

Cyanotoxin Removal in Drinking. Recreational Waters. Judy Westrick April 14, Northeast Regional Cyanobacteria Workshop

ROSS Technology Removal of Oil, Solids and Scale Formers

GUIDELINE FOR CONSTRUCTION AND APPROVAL OF PUBLIC WATER THE HEALTH HAZARD REGULATIONS

Longer lifetime for hydraulic oil

4 th & Carey Groundwater. Remediation Project and Reverse Osmosis Water Treatment System

Drinking Water Treatment Systems

Partner for automation Water technology

Rotary screw compressors kw 5,5 7, , bar MODULO

Ultra Violet Disinfection

Royal Caribbean International Advanced Wastewater Purification Systems

Installation Instructions

The 3rd Busan Global Water Forum Multi-Parameter Water Quality Monitoring System. Aqua of Sep 2015 Kyung-Yup Hwang

How To Use A Ds340 (Dsp)

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Contamination Control for the Primary Metals Industry

Technical Paper Presented at Southwest Chemistry Workshop, Farmington, NM, June 23-24, 2009

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

ADVANCED TREATMENT OF RAINWATER USING METAL MEMBRANE COMBINED WITH OZONATION

Dr. Kornder. Anlagen- und Messtechnik GmbH & Co. KG. Company Profile

Preventing Travellers' Diarrhoea: How to Make Drinking Water Safe

COOLING WATER MANAGEMENT

Laboratory water purification systems

CHEMICAL CLEANING EXPERIMENTS FOR PERFORMANCE RESTORATION OF NF MEMBRANES OPERATED ON SEAWATER FEED 1

Cross-Flow for Wine. Gentle and efficient filtration

Kompressoren. Oil Water Separators OWS

Water Info. What is Reverse Osmosis?

MOBILE WATER TREATMENT FACILITY UMUV 01

Transcription:

Seccua Product Presentation

Technology

Membrane Technology Color Turbidity Endocrines Bacteria Virus Dissolved Solids 1000 nm 100 10 1 0,1 nm 100 µm 10 1 0,1 0,01 0,001 µm Reverse Osmosis dp = 15 bar 80 bar Ultrafiltration dp = 0,5 bar 2 bar Nanofiltration dp = 5 bar 12 bar

Raw Water Turbidity Virus, Bacteria & other Color Residuals of Medicals Pesticides Ultrafiltration Flocculation Ultrafiltration Activated Carbon Ultrafiltration Drinking Water

Filtration Raw water flows into capillary and through the walls of the hollow fiber All particles, bacteria and virus are rejected by the membrane surface A fouling layer from rejected substances is building up on the membrane

Forward Flush A rapid cross-flow flush using raw water cleans out the inside of the hollow-fibers. Non-compressed fouling layers are being removed. Sticky or compressed fouling layers remain on membrane.

Backwash Filtered water is flowing through the membrane in reverse filtration-direction. Compressed fouling layers are lifted of the membrane and flushed out. On industrial and municipal systems chemicals can be added to improve backwashperformance.

Low-Energy-Ultrafiltration High tolerance for suspended solids (> 20 FNU) Low-fouling, state-of-the-art polymer membrane Up to 50% lower pressure required than with conventional UF membranes. Uniform, strong fiber-walls reduce risk fiber damages

Ultrafiltration-Modules Surface Areas ranging from 2 to 50 m 2 (20 to 540 ft 2 ) DVGW and NSF - approved ISO-conforming production Temperature resistant up to 60 C (175 F) Made in Germany

Products

Phoenix up to 35 m3/h X-Spot Pro up to 2 m3/h Virex Pro up to 4 m3/h 0 m3/h 2 m3/h 4 m3/h 8 m3/h 35 m3/h Seccua UF Product Range Point-of-Entry up to high-performance industrial, commercial and municipal

X-Spot Pro Filtration capacity up to 15 gpm during peak loads Removes turbidity and pathogens, including Crypto, E-Coli and Virus Flushes only when fouled and required or at time-of-day Postpones flush when water-usage is detected.

Case A: Low turbidity Performance, (Permeability) Settings: 1. Minimum Filtration Duration: 4 hours 2. Cleaning at 60% of initial performance 3. Do not clean when water is used 4. Clean at 2 a.m. no matter if fouled 5. Duration of cleaning 20 seconds 100 % New, clean filter e.g. 60 % 2 a.m. cleaning-by-time initiated Threshold for cleaning 12 p.m. 6 p.m. 12 a.m. 6 a.m. Time

Case B: High turbidity Performance, (Permeability) Settings: 1. Minimum Filtration Duration: 4 hours 2. Cleaning at 60% of initial performance 3. Do not clean when water is used 4. Clean at 2 a.m. no matter if fouled 5. Duration of cleaning 20 seconds 100 % New, clean filter e.g. 60 % Threshold for cleaning Cleaning at fouling-threshold Cleaning at fouling-threshold delayed due to water usage 12 p.m. 6 p.m. 12 a.m. 6 a.m. Time

Case C: High, varying turbidity Performance, (Permeability) min. filtration time Settings: 1. Minimum Filtration Duration: 4 hours 2. Cleaning at 60% of initial performance 3. Do not clean when water is used 4. Clean at 2 a.m. no matter if fouled 5. Duration of cleaning 20 seconds 100 % Increase of turbidity New, clean filter e.g. 60 % Cleaning at fouling-threshold Threshold for cleaning Cleaning at fouling-threshold delayed until min. filtration time is reached 12 p.m. 6 p.m. 12 a.m. 6 a.m. Time

Virex Pro Filtration capacity up to 85 Liters per Minute Removes turbidity and pathogens, including Crypto, E-Coli and Virus Long-term safety through integrated, automatic membrane-integrity-testing Fully automated cleaning when membrane is fouled, if required chemically enhanced Controls feed-, backwash- and dosingpumps SMS alert transmission and full remote control through PC software

Built in PLC

Scale up

Phoenix Filtration capacity up to 35 m3/h Removes turbidity and pathogens, including Crypto, E-Coli and Virus Long-term safety through integrated, automatic membrane-integrity-testing Fully automated cleaning when membrane is fouled, if required chemically enhanced Controls feed-, backwash- and dosingpumps SMS alert transmission and full remote control through PC software

Take full control

Unique propositions Certified virus removal, greater than 99,99% Certified bacteria and parasites removal, greater than 99,9999% Full removal of turbidity, independent of feed-water quality. Automatic adaption of cleaning-cycles to variations in feed-water-quality. System minimizes risk of membrane damage by too high differential pressure through smart control. Industrial material- and workmanship-quality for long life-time.

Unique propositions Integrated Membrane Integrity test grants long-term reliable removal of pathogens during operation (Virex Pro and Phoenix). Virex Pro and Phoenix - Series control all required peripherals, no further PLC necessary. Remote alert transmission and full remote access and control with Virex Pro and Phoenix controls, together with a GPRS modem.

Selected Applications

Selected Applications Drinking water desinfection in homes, commercial and industrial. Pathogens and algae removal in mineral water bottling. Removal of pathogens, micro-organisms and particles from process- and ingredient-water in food-production. Particle-removal and desinfection of circulating swimming-pool water. Swimming-pool filter-backwash water treatment for irrigation. Legionella-removal in wellness-areas, schools, hotel and industry. Treatment of grey- and tertiary-wastewater.

Benchmarking

Benchmarking 1 2 3 n.v. Virus removal Fiber shock-protection Membrane-testing Comfortable automation Flush when fouled only Remote control and alert transmission Virex Pro Virex Pro Phoenix GE Homespring Pentair Freshpoint AJA UF/UFL TAP Pall Filtrix Lineguard

Filtrate performance 90,0 67,5 +22% Virex Pro X-Spot Pro Filtrix LineGuard UF-100 Homespring Freshpoint, AJA 45,0 22,5 Virex +15% X-Spot 0 Flow (l/min at 2 bar)

Removal performance Virus >25 nm E-Coli Removal rates (examples): 1.000 pathogens in Feed, rejection 4 log = 0 pathogens in filtrate Seccua UF >4 log >6 log 10.000 pathogens in Feed, rejection 3 log = 40 pathogens in filtrate AJA UF/UFL/TAP >3,5 log >6 log Germs in feed 2 log 1.000 10.000 100.000 10 100 1000 3 log 1 10 100 Pentair Freshpoint >3,5 log >4 log 4 log 0 1 10

Cleaning and testing Cleaning in place Chemically enhanced cleaning Membrane integrity-test Virex Pro, Phoenix fully automated combined caustic/acid cleaning fully automated and integrated X-Spot Pro AJA UF/UFL/TAP GE Homespring Freshpoint adapting to feed-waterquality, no flush when water is used fixed intervals (time or flow), frequency set to worst-case fixed intervals (time or flow), frequency set to worst-case fixed intervals (time or flow), frequency set to worst-case n/v n/v n/v n/v n/v n/v n/v n/v

Dimensions: Phoenix Phoenix 4 Phoenix 7 Phoenix 10 Aria Pall Aria LT 1 Pall Aria LT 2 Pall Aria LT 4 Phoenix: modular set-up, units smaller than 80x59x187 cm fits through every door, can be set-up around a corner Pall Aria: cannot be broken down, 133x80x260 cm Ceiling heights >260 cm Doesn t fit through doors!

Control technology Feed-pump Chemical dosing Backwashpump Feed-buffertank Bus connection Virex Pro Digital or 4-20 ma Feed and backwash Digital Feed CAN-Bus to all standards Phoenix Digital or 4-20 ma Feed and backwash Digital Feed CAN-Bus to all standards Pall Aria Digital -- Digital -- -- Homespring -- -- -- -- --

Monitoring and Alert-Transmission Alert transmission Alarmeingang Remote Access Telemetry Data logging Virex Pro Cold Contact SMS Cold Contact Digital via GPRS, USB, Bus up to 90 days Phoenix Cold Contact SMS Cold Contact Digital via GPRS, USB, Bus up to 90 days Pall Aria Cold Contact -- -- -- -- Homespring -- -- -- -- --

Join us!