East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE



Similar documents
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

SECTION /600 VOLT CABLE, WIRE AND CONNECTORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851

ELECTRICAL: WIRE, CABLE, AND TERMINATIONS

STABILOY BRAND FeeDeR SOLuTIONS

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

STABILOY BRAND FeeDeR SOLuTIONS

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

BASIC NEC CODE RULES AND DESIGN PRACTICE

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Voltage Drop (Single-Phase)

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

CHAPTER 2 EXAMPLES AND TABLES

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

A. Shop Drawing submittals shall include, but not be limited to, the following:

SECTION SIGNAL WIRE AND CABLE

CalMod Design-Build Electrification Services

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Exhibit C Design Review Guidelines

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Requirements for Electrical Installations

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

C. Conform to requirements of Americans with Disabilities Act (ADA).

SECTION COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

How to Estimate the Cost of a Clean Room and Data Center Equipment Electrical Work. Section 2 Types of Methods of Measurements page 4

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

SECTION LOW VOLTAGE LIGHTING CONTROLS

MANUFACTURER S CERTIFICATE OF COMPLIANCE

Electrical Extension Cords & Relocatable Power Taps: (RPT s)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TC Grounding and Bonding for Telecommunications Systems

Building Cables and Wires

STREETLIGHT SYSTEM GROUNDING AND BONDING

TABLE OF CONTENT

Electrical Code Regulation

CITY OF LOS ANGELES CALIFORNIA

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Installation and Application Guide. for 600V Conductors

KNOW YOUR OPTIONS: 230 KV POWER CABLES

THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER

Top Commercial / Residential Electrical Requirements *

Insulation Resistance Testing of Low Voltage Cables in the Field

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

800 Communications Circuits

INSPECTION GUDELINES

Section kv Power Cables

Recommended Practices for Designing and Installing Copper Building Wire Systems

City of Riverside Building & Safety Division Phone: (951)

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Engineers Edge, LLC PDH & Professional Training

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

SERVICE - GENERAL Residential, Commercial, Industrial

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

GUIDELINES HAS/PDC/DESIGN DIVISION TITLE

Extension Cord Safety Policy

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

CONDUCTOR SHORT-CIRCUIT PROTECTION

Uptown Campus, Primary Electric Master Plan - Program Study State University of New York At Albany, SUCF Project No V.

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Electrical Design Training Class Ampacity WSDOT Winter 2008 BZA

San Diego Area Chapter International Code Council

ELECTRICAL INSPECTION BULLETIN (Effective )

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

NEC 2014 Code Changes

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Evaluating Water-Damaged Electrical Equipment

2011 NEC Summary of Changes. Chapter Summary of Changes. Article Section Summary of Change

Transcription:

SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders, branch circuit power, lighting systems and other systems specified. b. Wiring connectors and connections. 1.2 RELATED SECTIONS A. Section 260533 - Conduit. B. Section 260534 - Boxes. C. Section 260526 - Grounding and Bonding. D. Section 260553 - Identification. 1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code, 2008 edition. 1.4 QUALIFICATIONS A. Manufacturer: Company specializing in manufacturing products specified in this Section with minimum 3 years experience. 1.5 SUBMITTALS A. Submit shop drawings and product data per Division 1. B. Indicate material specifications, dimensions, capacities and color coding. C. Provide product data for all wire and cable. D. Submit manufacturer s installation instructions. 1.6 REGULATORY REQUIREMENTS BUILDING WIRE & CABLE 260519-1

A. Conform to requirements of ANSI/NFPA 70. B. Furnish products listed and classified by UL as suitable for purpose specified and shown. 1.7 REFERENCES A. If conflict between referenced standards and contract documents, notify Architect/Engineer immediately. Do not proceed with the work until the Architect/Engineer issues instructions. B. National Electrical Manufacturers Association (NEMA): 1. WC 3 - Rubber-Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy. 2. WC 5 - Thermoplastic-Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy. 3. WC 7 - Cross-Linked-Thermosetting-Polyethylene-Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy. C. National Fire Protection Association (NFPA): NFPA 70- National Electrical Code. D. Manufacturers Catalogs: Specified manufacturers catalogs are incorporated by reference to same force and effect as if repeated herein full. 1.8 PROJECT CONDITIONS A. Verify that field measurements are as shown on Drawings. B. Conductors shall be copper. C. Where wire and cable routing is not shown, and destination only is indicated, determine exact routing and lengths required. 1.9 COORDINATION A. Determine required separation between cable and other work. B. Determine cable routing to avoid interference with other work. PART 2 - PRODUCTS 2.1 BUILDING WIRE AND CABLE A. Thermoplastic insulated building wire: NEMA WC 5, UL-83 ICEA S-61-402 or S-66-524. B. Feeders and branch circuits 250 MCM and larger: Copper, stranded conductor, 600 volt insulation THHN/THWN. BUILDING WIRE & CABLE 260519-2

C. Feeders and branch circuits larger than 8 AWG and smaller than 250 MCM: Copper, stranded conductor, 600 volt insulation THHN/THWN. D. Feeders and branch circuits 8 AWG and smaller: Copper conductor, 600 volt insulation THHN/THWN, solid or stranded conductor. E. Control Circuits: Copper, stranded conductor, 600 volt insulation THW, THHN/THWN. F. Underground feeders and circuits: Copper, stranded conductor, 600 volt insulation, type XHHW. G. Color code conductors as specified in Section 260553 - Electrical Identification. 2.2 JOINTS AND SPLICES A. Make terminations, taps and splices with an indent type pressure connector with insulating cover for 8 AWG and smaller. B. Instead of indent type connectors insulated spring compression connectors may be used for 10 AWG and smaller. C. Use mechanical compression or bolted type connector for 6 AWG or larger. Cover connector with insulating type or heat shrinkable insulation equivalent to 150% conductor insulation. 2.3 WIRE PULLING LUBRICANT A. Pulling lubricant shall be UL listed, water-based, polymer solution. Lubricants containing waxes or soaps are not acceptable. B. The lubricant shall be compatible with the cable insulation and shall not cause any premature deterioration of the insulating material. When use on high voltage cable, the lubricant shall not affect the volume resistivity of any semi-conducting jacket or insulation shield present. C. Dried residue from lubricant shall not become tacky or gum-up. Cables shall remain pullable after lubricant has dried. D. The lubricant shall be approved by the cable manufacturer for use with their cables. E. Acceptable Manufacturers/Products: 1. American Colloid/Poly-X. 2. American Polywater/Polywater J. 3. ARNCO/Hydra-Lube. 4. Buchanan/Quick Slip. 5. Condux/Super-Lube. 6. Ideal/Aqua-Gel. PART 3 - EXECUTION BUILDING WIRE & CABLE 260519-3

3.1 EXAMINATION A. Verify that interior of building has been protected from weather. B. Verify that mechanical work likely to damage wire has been completed. 3.2 PREPARATION A. Completely and thoroughly swab raceway before installing wire. 3.3 WIRING METHODS A. Concealed Dry Interior Locations: Use only building wire. B. Exposed Dry Interior Locations: Use only building wire, in raceway. C. Above Accessible Ceilings: Use only building wire, in raceway. D. Wet or Damp Interior Locations: Use only building wire, in raceway. E. Exterior Locations: Use only building wire, in raceway. F. Underground Installations: Use only building wire, in raceway. G. Use wiring methods indicated on Drawings. 3.4 INSTALLATION A. Install products in accordance with manufacturer s instructions. B. Use conductor not smaller than 12 AWG for power and lighting circuits. C. Use conductor not smaller than 14 AWG for control circuits. D. Use 10 AWG conductors for 20 ampere, 120 volt branch circuits longer than 80 feet. E. Use 10 AWG conductors for 20 ampere, 277 volt branch circuits longer than 140 feet. F. Pull all conductors into raceway at same time. G. Use suitable wire pulling lubricant for building wire 4 AWG and larger. H. Protect exposed cable from damage. I. Use suitable cable fittings and connectors. J. Neatly train and lace wiring inside boxes, equipment, panelboards and switchboards. BUILDING WIRE & CABLE 260519-4

K. Clean conductor surfaces before installing lugs and connectors. L. Make splices, taps and terminations to carry full ampacity of conductors with no perceivable temperature rise. M. Place an equal number of conductors for each phase of a circuit in same raceway or cable. N. Splice only in accessible junction, outlet boxes, cable tray or surface metal raceway. O. Make conductor lengths for parallel circuits equal. P. Provide dedicated neutral conductor for each computer lab circuit. 3.5 IDENTIFICATION A. Identify wire and cable under provisions of Section 260553. B. Identify each conductor with its circuit number or other designation indicated on Drawings. 3.6 FIELD QUALITY CONTROL A. Inspect wire and cable for physical damage and proper connection. B. Measure tightness of bolted connections and compare torque measurements with manufacturer's recommended values. C. Verify continuity of each branch circuit conductor. END OF SECTION 260519 BUILDING WIRE & CABLE 260519-5