Pyrotracer Video C.A 650



Similar documents
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Panel Meters and Controllers Modular Panel Meter Type EDM 35

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

PCS0100en Persy Control Services B.V. Netherlands

CQM1-SF200/CS1W-SF200

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Voltage Regulator SPAU 341 C. Product Guide

Digital input modules

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Hand-held thermometer Model CTH7000

Quick Connect. quick - simple - efficient.

Telephone- and leased line modem for industrial applications TD-36

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Power Meter Series 700

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

HWg-STE HWg-STE PoE MANUAL

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Duct Humidity Transmitter

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

5000V Graphical Megohmmeter Model 5070

Temperature & Humidity SMS Alert Controller

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

PIEZOMETER AIRFLOW MEASURING RING

Digital Pressure Measuring Instrument MDR480

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Installation manual. Generator Paralleling Controller GPC multi-line C

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

T Substation Maintenance and Commissioning Test Equipment

Applications. diris_826_a_1_gb_cat

Multi-Range Programmable DC Power Supplies 9115 Series

IntesisBox Modbus Server Fidelio IP

Electronic Control Devices The European Product Catalogue 2007

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

DC Electronic Loads 8500 series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Eurotherm Chessell Graphic Data Acquisition Recorders. Ethernet Communication Data Historian, Reports, Real Time Monitor

Analog signal converters CC-E I/I Current / current isolators

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Energy Management Power Analyzer Type WM14-96 Basic Version

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Chassis, Power Supply, and Element Management

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

HMI display Installation Guide

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Multi-Function Ground

Digital multimeters DMG

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

Communicate and view data from meters with one simple device

smart-house Controller Central Unit Module Type SH2WEB24

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

IntesisBox KNX Modbus TCP master

NETWORK ENABLED EQUIPMENT MONITOR

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

PowerCommand 500/550 Remote Monitoring System

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Application/Connection Examples

1. SAFETY INFORMATION

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Short information Parameters are programmed via front-side membrane keypad

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Nardalert S3 Non-Ionizing Radiation Monitor

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Model: DC-A2IO Advanced HVAC Controller

Process Alarm Solutions

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Handheld portable appliance testers

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

OZW30. Central Unit SYNERGYR

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

40.3. Control Relays and Timers

Disturbance Recoder SPCR 8C27. Product Guide

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic Control Devices The European Product Catalogue 2007

Transcription:

Production lot traceability, at your fingertips Pyrotracer Video C.A 650 "Plug & play" paperless recorder for the traceability needs of the most demanding industry environments. Rapid set-up and ease of use. Tamper-proof encrypted files for totally secure "Quality" recording. Very-high-definition 6.1-inch 256 colour TFT screen Up to 18 configurable isolated measurement channels Data back-up using 128 Mb Compact Flash memory Includes as standard Ethernet link + PC processing software

Pyro-Contrôle presents a "plug & play" paperless recorder equipped with an 18-bit converter, offering extremely high precision measurements and a polling speed of 200 ms per channel! With a very high definition 6.1" TFT display screen, and 18 isolated measurement channels, the Pyrotracer Video measures up to the most demanding of thermal process industry requirements. Trend Mode The replacement of conventional recorders by paperless recorders offers the following advantages: Simpler maintenance - no longer the need to replace used parts; The increased benefits of digital precision over electromechanical precision; Computerised processing of data via PC link; Remote adjustment and calibration via field bus; Possibility of both on-site and remote processing of data. Vertical or horizontal display of 6 curves in real time Curves identified by colour and process indicators Simplified "Page" display function Permanent date-time display Automatic "Alarm" and "Memory Full" Warning icon Histogram mode Whatever the industry - food processing, laboratories & hospitals, chemicals, metallurgy, steel-making, petrochemicals or glass manufacturing - these instruments permit the acquisition, recording & display of the physical quantities of processes, thereby providing on-demand traceability to quality departments; as well as data for testing and calibration, the analysis and development of processes, and their troubleshooting and maintenance. In addition to the simplicity of access provided by its system of "plug & play" cards, the Pyrotracer Video ensures total security of use, thanks to 18 fully-isolated channels and tamper-proof file encryption. Data is recorded in the instrument's integrated 8Mb memory, and automatically transferred to the memory card when the memory use reaches 95%. 6-column bar graph display Individual scale configuration for each histogram Curves identified by colour and process indicators "Hi/Lo" alarm status indicators Permanent date-time display Automatic "Alarm" and "Memory Full" Warning icon Digital input display With total autonomy of use guaranteed by its 8 Mb memory capacity, very-high-definition screen and Windows CE ergonomy, the recorder offers greatly enhanced data representation and analysis capabilities thanks to their direct processing on PC. For this reason, the Ethernet link and data processing software are included as standard. Data may also be accessed via a field bus connected to an RS 232 or RS 485 link. Real-time display of 6 analogue inputs Colour differentiated value and process indicators "Hi/Lo" alarm status indicators Permanent date-time display Automatic "Alarm" and "Memory Full" Warning icon

Historical mode DIMENSIONS Vertical or horizontal display of 6 time series curves Automatic display of numerical values - selected by cursor "ZOOM" function for expanding and reducing Time scale Curves identified by colour and process indicator Alarm log Subdivisions of the panels Log includes full date/time listing of all alarms "Browse" function to select and clear alarms Uncleared alarms displayed in red for High, green for Low Configuration of entry settings of analogue inputs Pt100, TC, mv, V, ma of analogue outputs Configuration of input/output/name/event pens Page configuration (colours, pens, decimal format, pen + link, etc.) Configuration of timer Configuration of internal functions (storage memory, display, communication, real-time clock, etc.) of logical inputs of relay outputs

Ethernet connection Power supply Front panel 6 x slots Rear view Infrared sensor for screen saver 6 slots for input/output boards Each type of board is recognized individually. Up to 18 analogue inputs possible (3 inputs x 6 slots) 6 Programming keys View of the programming keys and memory card protection strip Memory card Type of input/output boards Logical input Relay output Analogue input Portable version On/Off switch Input configuration microswitch Carrying handle Memory card

Power supply 90-264 VAC, 47-63 Hz, 60 VA, 30 W maximum 11-18 or 18-36 VDC 60 VA, 30 W maximum Display / Screen 6.1" LCD TFT, 640 x 480 pixels, 256 colours Memory Basic storage memory: 8 MB Compact Flash: 16 MB standard 64 or 128 MB optional Analogue input board Channels: 3 per board Resolution: 18 bits Polling time: 200 ms Maximum value: -2 VDC minimum, 12 VDC maximum (1 minute max. for ma) Temperature drift: ±1.5µV/ C except ma inputs ±3.0µV/ C for the ma inputs Influence of line resistance: TC: 0.2 µv/w Pt100, 3 wires: 2.6 C/Ω of difference between two branches Break-induced sensor current: 200 na Common mode rejection: 120 db Serial mode rejection 55 db Insulation voltage between channels: at least 430 VAC min Detection of sensor failure: Sensor open-circuit for TC, Pt100 and mv inputs, below 1 ma for the 4-20 ma input, below 0.25 V for the 1-5 V input, not applicable to the other inputs Response time after a sensor failure: 10 seconds for TC, Pt100 and mv, 0.1 second for 4-20 ma and 1-5 V. Type Scale Precision at 25 C Impedance J 120...1 000 C ±1 C 2.2 MΩ K -200...1 370 C ±1 C 2.2 MΩ T -250...400 C ±1 C 2.2 MΩ E -100...900 C ±1 C 2.2 MΩ B 0...1 820 C ±2 C 2.2 MΩ S 0...1 767.8 C ±2 C 2.2 MΩ R 0...1 767.8 C ±2 C 2.2 MΩ N -250 1300 C ±1 C 2.2 MΩ L -200 900 C ±1 C 2.2 MΩ Pt100 (DIN) -210 700 C ±0.4 C 1.3 kω Pt100 (JIS) -200 600 C ±0.4 C 1.3 kω mv -8 70 mv ±0.05% 2.2 MΩ ma -3 27 ma ±0.05% 70.5 Ω V -0.12 1.15 mv ±0.05% 32 kω 0/5 V -1.3 11.5 V ±0.05% 332 kω 1/5 V -1.3 11.5 V ±0.05% 332 kω 0/10 V -1.3 11.5 V ±0.05% 332 kω Logical inputs board Channels: 6 per board Low level: 0 V minimum, 0.8 V maximum High level: 2 V minimum, 30 V maximum External pull-down resistance: 1 kω maximum External pull-up resistance: 1.5 kω maximum Relay outputs board Relays: 6 per board Type of contact: N.O. (normally open). Type of relay: 5 A/240 VAC, number of cycles: 200,000 (resistive load). Communication module Interface: RS232 (1 x C.A 650), RS485, or RS422 (up to 247) Protocol: Modbus RTU Address: 1-247 Speed: 0.3~38.4 kbits/sec. Data bits: 7 or 8 bits Parity bit: None, Even, or Odd Stop bit: 1 or 2 bits Ethernet communication module Protocole : ModBus TCP/IP, 10 BaseT Self-bias correction for 10 BaseT Ports: AUI and RJ-45, auto-detect capability Infrared sensor Detection of human presence up to 2m (screen saver) Dimensions and environment conditions Operating temperature: 5 C to 50 C Storage temperature: -25 C to 60 C Humidity: 20 to 80% RH (without condensation) Insulation resistance: at least 20 MΩ (at 500 VDV) Dielectric strength: 3 kvac 50/60 Hz for 1 minute Vibration resistance: 10-55 Hz, 10 m/s 2 for 2 hours Impact resistance: 30 m/s 2 (3 g) in operation, 100 g during transport Dimensions: 166 mm (W) x 144 mm (H) x 174 mm (D), cabinet mounting Compliance with standards Safety: UL873 (11 th edition, 1994) CSA C22.2 No. 24-93 CE: EN61010-1 (IEC1010-1) Overvoltage category II, Pollution degree 2 Protection class for indoor use: IP30 for front panel of cabinet, IP20 for wiring EMC Emission: EN50081-1, EN61326 (EN55011 class B, EN61000-3-2, EN61000-3-3) Immunity: EN50082-2, EN61326 (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4 11, EN50204) TO ORDER C.A 650 1 2 3 4 5 6 7 8 9 10 Caution: the recorder has a maximum of 6 slots 1 Power supply Code 4 : 90-264 VAC 47-63Hz standard 6 : 11-18 VDC LR00110-000 7 : 18-36 VDC LR00111-000 2 Analogue inputs LR00112-000 0 : no analogue inputs 0 3 : 3 Analogue inputs 1 slot 6 : 6 Analogue inputs 2 slots A : 9 Analogue inputs 3 slots B : 12 Analogue inputs 4 slots C : 15 Analogue inputs 5 slots D : 18 Analogue inputs 6 slots 3 Logical inputs LR00113-000 0 : no logical inputs 0 1 : 6 Logical inputs 1 slot 2 : 12 Logical inputs 2 slots 4 Relay outputs LR00114-000 0 : no relays 0 1 : 6 relays 1 slot 2 : 12 relays 2 slots 5 Communication 0 : standard Ethernet communication 1 : RS232/422/485 (3 in 1) + Ethernet interface LR00116-000 6 Configuration software 1 : Standard: "Observer 1" software 7 Software of the C.A 650 0 : basic 1 : Calculation, metering, and totalling accumulator function LR00117-000 8 Compact Flash 1 : 16MB standard 9 Mounting the C.A 650 1 : Standard: cabinet mounting version 2 : Portable version with carrying handle LR00118-000 10 Option 0 : no option 1 : 24 VDC transmitter power supply (up to 6) [1 slot] LR00115-000 ACCESSORIES: "Observer 2" software LR00122-000 16 MB Compact Flash memory LR00119-000 64 MB Compact Flash memory LR00120-000 28 MB Compact Flash memory LR00121-000

Chauvin Arnoux expertise PYRO-CONTROLE Export Sales Department TEST & MEASUREMENT Hand-held test and measurement instruments for field and laboratory Hand-held testers and multimeters Current measurements Electrical testing and safety Power, Energy, Perturbation Physical testing and measurement Data acquisition Laboratory and educational instrumentation RF and microwave measurements Testing of computer and telecommunication networks Accessories Tel.: +33 1 44 85 44 85 Fax: +33 1 46 27 73 89 E-mail: export@chauvin-arnoux.fr ENERDIS Systems and equipment for the measurement, control, metering and monitoring of electrical networks Measuring transformers and shunts Transducers Analogue and digital panel meters Power monitors Energy meters Energy supervision and management systems Network analysers and graphic recorders Measuring relays Industrial relays Displacement sensors Meteorological measurements Tel.: +33 1 47 46 78 00 Fax: +33 1 42 53 64 78 E-mail: export@enerdis.fr MANUMESURE Calibration, repair, maintenance, qualification, and other services for industry Repair and Maintenance of "All brand" instruments Testing and calibration Instrument fleet management Electromagnetic compatibility tests Electrical safety tests Atmospheric pollution monitoring Biomedical apparatus maintenance Maintenance and metrology training Tel.: +33 2 31 64 51 43 Fax: +33 2 31 64 51 09 E-mail: export@manumesure.fr AUSTRIA Tel.: (43) 1 616 19 61 Fax: (43) 1 616 19 61 61 E-mail : vie-office@chauvin-arnoux.at CHINA Tel.: (86) 21 65 08 15 43 Fax: (86) 21 65 21 61 07 E-mail : enerdisb@online.sh.cn GERMANY Tel.: (49) 78 51 99 260 Fax: (49) 78 51 99 26 60 E-mail : info@chauvin-arnoux.de ITALY Tel.: (39) 039 2 45 75 45 Fax: (39) 039 48 15 61 E-mail: info@amra-chauvin-arnoux.it LEBANON Tel.: (961) 1 890 425 Fax: (961) 1 890 424 E-mail : camie@chauvin-arnoux.com Your distributor Subsidiaries and sales departments abroad SPAIN Tel.: (34) 93 459 08 11 Fax: (34) 93 459 14 43 E-mail : comercial@chauvin-arnoux.es SWEDEN Tel.: (46) 8 50 52 68 00 Fax: (46) 8 50 52 68 10 E-mail: jb@camatsystem.com SWITZERLAND Tel.: (41) 1 727 75 55 Fax: (41) 1 727 75 56 E-mail: info@chauvin-arnoux.ch UNITED KINGDOM Tel.: (44) 1 628 788 888 Fax: (44) 1 628 28 099 E-mail : info@chauvin-arnoux.co.uk USA Tel.: (1) 508 698 2115 Fax: (1) 508 698 2118 E-mail: sales@aemc.com PYRO-CONTROLE for export For all other countries Tél.: (33) 4 72 14 15 55 Fax: (33) 4 72 14 15 41 E-mail: export@pyro-controle.tm.fr 906 211 113 - Ed.1-01/05 - Non contractual document - Confirm specifications before ordering. Pyro-Contrôle 244, avenue Franklin Roosevelt 69516 VAULX-EN-VELIN Cedex - France Tél.: +33 4 72 14 15 55 Fax : +33 4 72 14 15 41 info@pyro-controle.tm.fr www.pyro-controle.com