STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM



Similar documents
PERC-RITE DRIP DISPERSAL DESIGN GUIDE FOR SEPTIC TANK OR ADVANCED TREATMENT EFFLUENT MAINE

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

16 12 INDIVIDUAL SEWAGE DISPOSAL CODE OF HOPEWELL TOWNSHIP.

Louisiana Administrative Code Title 51 Part XIII. Sewage Disposal

Septic Systems and Their Maintenance

SPDES PRIVATE, COMMERCIAL, INSTITUTIONAL GENERAL PERMIT FOR SANITARY WASTEWATER DISCHARGES TO GROUNDWATER FACT SHEET

Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia

Glen Hills Area: Septic System and Public Sewer Q & A Information Sheet Page 1

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

On Site Treatment Systems

SECTION 6 EXISTING WASTEWATER MANAGEMENT SYSTEMS

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

RECOMMENDED PROGRAM FOR WELL AND SEPTIC SYSTEM REAL ESTATE TRANSACTION INSPECTIONS

CONTAMINANT SOURCES. JUNE 1998 Printed on recycled paper

HOW A SEPTIC SYSTEM FUNCTIONS

GUIDANCE DOCUMENT FOR DEVELOPMENTS AND SUBDIVISIONS WHERE ONSITE WASTEWATER TREATMENT SYSTEMS ARE PROPOSED

#4.43 HYDRAULIC WASTEWATER LOADING RATES TO SOIL. E.J. Tyler* ABSTRACT INTRODUCTION

COST AND PERFORMANCE REPORT

Planning and Installing an Onsite Wastewater Management System

Understanding and Living With Your Septic System

Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System

Lance DeClue, REHS Environmental Health Specialist II County of San Diego Department of Environmental Health

INDEX. Introduction 3. The Septic System 3. What Does The Septic Tank Do? 4. Where It All Goes 5. Problems 7. Some Dontʼs 8

STATUS REPORT: Bacteria and Other Contaminants in Domestic Water Wells in the Jackson Purchase Region

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

SECTION III. LEACHING AREA REQUIREMENTS Residential square footage requirements are based on sidewall area only: Minimum square feet per bedroom

Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It

Town of Ware Board of Health. Regulations for Percolation Tests, Soil Evaluations, Design, and Technical Review of Subsurface Sewage Disposal Systems

SHORELINE SANITATION

Homeowner s Guide to Maintaining a Sewage Treatment System

Ground Water in the Piedmont and Blue Ridge Provinces of North Carolina

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

YOUR SEPTIC SYSTEM UNCOVERED

ON-LOT SEWA G E S Y S T E M S

Type of Sewer Systems. Solomon Seyoum

A MODEL PROGRAM FOR ONSITE SYSTEM MANAGEMENT IN THE CHESAPEAKE BAY WATERSHED

Designing Septic Systems

Specifications for Residential Property Owners Connection to New Public Sewer

Disposal of Municipal Wastewater Treatment Plant Effluent by Indirect Discharge to Surface Water via Groundwater or Hyporheic Water

Septic Systems. A Buyer s & Seller s Guide. First American Title Insurance Company of Oregon

So... now you own a septic system

FARM A SYST Farmstead Assessment System. Drinking Water Well Condition

Understanding and Caring for Your Septic System

Conserving Natural Resources in Illinois

Septic System Management Plan for Below Grade Systems

CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810

Texas Natural Resource Conservation Commission Page 1 Chapter 285- On-Site Sewage Facilities

Northeast Tri County Health District

Assessing Your Septic System

FREQUENTLY ASKED QUESTIONS. New Subsurface Sewage Treatment System (SSTS) Ordinance

What Is An On-Lot Sewage Disposal System?

APPENDIX F. RESIDENTIAL WATER QUALITY PLAN: ALLOWABLE BMP OPTIONS

Well Records and Maintenance Guidelines

TECHNICAL BULLETIN. Location of the system. Percolation tests for drainage fields. Cesspool sizing. Suggested Information notices

ources of Drinking Water

Appendix D.1. Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils

CHAPTER 2 HYDRAULICS OF SEWERS

ENVIRONMENTAL CODE OF PRACTICE FOR CONCRETE BATCH PLANT & ROCK WASHING OPERATIONS

INFORMATION SHEET ORDER NO. R XXXX TRIANGLE ROCK PRODUCTS, INC. FLORIN ROAD AGGREGATE PLANT SACRAMENTO COUNTY

WASTEWATER TREATMENT AND DISPOSAL BY ON-SITE WASTEWATER TREATMENT SYSTEMS

Vulnerability Assessment

Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program Checklist for Stormwater Report

Fact Sheet #1 Reducing the Risk of Groundwater Contamination by Improving Drinking Water Well Condition

Onsite Wastewater Concepts, Materials, Regulations & The Application Process Part I

Septic Tank Maintenance Information

Dewatering Calculations, Treatment and Supporting Documentation

Aerobic Treatment Systems Guidance Document

OFFALY COUNTY COUNCIL Comhairle Chontae Uibh Fhailí

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems


Septic System Design Manual

GUIDELINE 39 SEPTAGE, SUMP AND PIT WASTE, AND RESTAURANT GREASE TRAP WASTE MANAGEMENT

IAC 7/11/12 Environmental Protection[567] Ch 68, p.1 CHAPTER 68 COMMERCIAL SEPTIC TANK CLEANERS

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

Understanding Septic Tank Systems

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

Pipeline. Too good to be true?

Fox Township On-lot Sewage Program

Soil depth: meters Type of restrictive layer:

Stormwater/Wetland Pond Construction Inspection Checklist

INTRODUCTION. AEROBIC TREATMENT UNITS (ATUs)

Septic System Owner s Manual

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

Coping With Contaminated Wells

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems

How To Calculate An Average Daily Flow

Vernal Pools: Introduction. Massachusetts state regulations that provide vernal pool protection

Guidelines For Sealing Groundwater Wells

KY-A-Syst for the Home Environmental Stewardship for Homeowners. Household Wastewater: Septic Systems and Other Treatment Methods

Characterizing Beauty Salon Wastewater for the Purpose of Regulating Onsite Disposal Systems

SEPTIC SYSTEM. Taking care of your. ... what you need to know

Guidance on applying for approval of installation of a commercial onsite wastewater system

FREQUENTLY ASKED QUESTIONS

Nature's Cleaning Process

septic systems What is a Septic System? How does a Septic System Work?

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

Table of Contents. Introduction

PROPERTY OWNERS ON-LOT SEWAGE MANAGEMENT PROGRAM GUIDANCE

City of Shelbyville Site Inspection Checklist

Transcription:

STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM Solid Waste Management Program Waste Management Division 103 South Main Street Waterbury, Vermont 05671-0404 (802) 241-3444 FAX (802) 241-3296 PROCEDURE ADDRESSING THE DISPOSAL OF CLOGGED SEPTIC SYSTEM STONE Original: June 30, 1996 Revised : February 8, 1999

Procedure, Disposal of Clogged Septic System Stone Page 1 of 2 PROCEDURE ADDRESSING THE DISPOSAL OF CLOGGED SEPTIC SYSTEM STONE I. Introduction Leach fields are used to treat liquid waste from septic tanks. Typically Leach fields are 1 to 3 feet deep with 4 feet wide trenches or greater if beds are used. Each leach field is filled with washed stone which acts as a highly permeable medium for distribution of the liquids from the pipe into the soil below where treatment occurs. Occasionally, the soil interface between the stone and soil becomes clogged with solids, preventing the liquids from percolating into the soil below the system. This results in a failed septic system. In many cases, the existing field is abandoned and a new leach field is designed. In general, all materials are left in place in the old leach field. In some cases, the removal and disposal of the clogged septic system medium ("clogged medium") is necessary to make room for a new leach field due to a lack of other available space for the new leach field. This Procedure addresses this latter case. While it is not always convenient to transport the clogged medium for disposal in a double lined landfill, disposal of this material at an unrestricted location is not appropriate. Controls on disposal are needed because the clogged medium may contain pathogens, including viruses and bacteria, that could be harmful to human health. Also, because the clogged medium consists primarily of rock and stone, it is not generally suitable for use as alternative daily cover in a landfill. This procedure supersedes the June 30, 1996, "Procedure Addressing The Disposal of Clogged Septic Stone". This procedure contains minor revision to reflect the revisions to the Vermont Solid Waste Management Rules ("Rules") (eff. January 15, 1998). II. Disposal Requirements This procedure provides an acceptable alternative to the disposal of leach field material in a lined landfill. Upon receipt of a written request submitted by the owner of the property where disposal of the leach field stone is proposed, by a registered professional engineer, or by a certified site technician, the Secretary of the Agency of Natural Resources (Agency) may determine that the on-site or off-site disposal of clogged medium generated from the repair or replacement of a failed on-site disposal system constitutes an Insignificant Waste Management Event Approval (IWMEA), as provided in Section 6-301(c) of the Rules. Information shall be submitted with the request which demonstrates that the following criteria are met: A. Minimum distances for the disposal location: 1. Edge of disposal area to adjoining property line - 50 feet; 2. Edge of disposal area to perennial stream or other waters of the state - 50 feet; 3. Bottom of waste to seasonal high groundwater - 3 feet;

Procedure, Disposal of Clogged Septic System Stone Page 2 of 2 4. Bottom of waste to bedrock - 4 feet; and 5. Edge of disposal area to a drinking water supply - Establish the minimum distance to a drinking water supply by using the presumptive methods listed in Vermont Water Supply Rule - Chapter 21 Section 11.4.1.1 or 11.4.1.2, assuming a disposal design flow of less than 2,000 gallons per day. B. Clogged medium may not be disposed of: 1. In a Class I or Class II groundwater area; 2. Within Class I or Class II wetland or associated buffer zone (100 feet for Class I, 50 feet for Class II); or 3. In a watershed for a Class A Waters: or 4. Within Zone 1 of a Public Community Water Supply (typically a 200' radius). C. Disposal of the clogged medium shall occur in accordance with the following procedures: 1. Clogged medium must be buried in a location not generally frequented by the public; 2. The medium must be covered with a minimum of 1 foot of soil to control vectors; and 3. The medium should be placed in layers or lifts not to exceed 12 inches in depth. Lime (Ca(OH)2) should be applied on the top surface of each layer in order to reduce pathogens. D. The recipient of the IWMEA shall ensure that the clogged medium be left in place, undisturbed for no less than 2 years. E. Following this procedure does not relieve the applicant from obtaining any local approvals that may be required for the disposal of clogged septic system stone. Effective Date: This procedure is effective upon date of signature Signature Signature 2/8/99 Canute Dalmasse, Commissioner Date Department of Environmental Conservation

TABLE B - REOUIRED SEPARATION DISTANCES VERMONT WATER SUPPLY RULE - CHAPTER 21 Required Minimum Separation Distances To Sewage System Disposal Fields (ft) 1,2 POTENTIAL SOURCE OF CONTAMINATION MAXIMUM DAILY DEMAND (gpm) Domestic Sewage System Disposal Fields (design flows): 0-1.9 2.0-4.9 5.0-7.9 >8.0 <2,000 gpd 100 150 200 200+ a ---------------------------------------------------------------------------------------------------------------------------------- 2.000 gpd -6,499 gpd 150 I50 200 200+ a ---------------------------------------------------------------------------------------------------------------------------------- >=6,500 gpd 200++ b 200++ b 200++ b 200+ a ---- ------------------------------------------------------------------------------------------------------------------------------- I the minimum separation distance, (X), is used to determine the minimum separation zone (see Subpart 11.4.1 and Figure 1). 2 For shallow water sources the minimum separation distance, X, per Subpart 1 1.4.1, shall not be less than 150 feet, and the minimum upslope separations distance shall be 500 feet instead of 2X regardless of the minimum separation distance, X, listed. If the bottom of the well or spring is higher than the ground surface at the disposal field then the minimum separation distance. X, may be reduced to 50 feet.. a Hydrogeologic evaluation required to define potential recharge area of the source and two year time of travel. b For all water sources with less than 8 gpm maximum daily demand, the minimum presumptive upslope separation distance to greater than 6.500 gpd leachfields, per Subpart 11.4.1, shall be 1,000 feet instead of 2X.

VERMONT WATER SUPPLY RULE - CHAPTER 21 11.4.1.0 Separation Distances to Sewage System Disposal Fields Wells and sewage system disposal fields should be located to optimize the hydrogeologic separation within the project limitations. The applicant's designer must establish a separation zone around the water source which defines the probable area of groundwater recharge to the water source. The separation zone may be established by a presumptive method which uses ground surface topography and minimum distances. The minimum separation distances for leachfields can be also estimated by using methods to define Well Head Protection Areas in accord with procedures defined in this rule (see Part 3 of this Appendix), or with other methods approved by the Agency. 11.4.1.1 Presumptive Minimum Separation Zone Methods for a Water Well To determine the size and shape of the required minimum separation zone between sewage disposal fields and a water well the following steps should be taken (see Figure 1): (a) (b) draw a circle with a radius equal to the required minimum separation distance. X, from Table B. around the well head or water source; now either: (1) if the circle drawn intersects with the contour elevation of the source. then draw lines beginning at these intersections, extending upslope and perpendicular to the contours, until these lines intersect an arc with a radius equal to twice the minimum separation distance (2X) from the source. If necessary, to provide closure of the area draw an arc with radius 2X from the source; or (2) if the circle drawn in Step I is in all cases at a lower elevation than the source elevation, no further delineation may be required (resulting in the smallest possible minimum separation zone of a circle with radius X); or, (3) if the circle drawn in Step I is in all cases is above the elevation of the well, the water shed area or a circle with a radius of 2X. whichever is smaller, shall represent the minimum separation zone (resulting in the largest possible minimum separation zone of a circle with a radius 2X). 11.4.1.2 Presumptive Minimum Separation Zone Methods for a Shallow Water Source To determine the size and shape of the required minimum separation zone between sewage disposal fields and a shallow water source, the following steps should be taken (see Figure 1): (a) (b) draw a circle with a radius equal to the required minimum separation distance, X. from Table B, around the well head or water source; now either: (1) if the circle drawn intersects with the contour elevation of the source, then draw lines beginning at these intersections. extending upslope and perpendicular to the contours, until these lines intersect an arc with a A-I I-8

VERMONT WATER SUPPLY RULE - CHAPTER 21 radius equal to 500 feet from the source. If necessary, to provide closure of the area draw an arc with radius of 500 feet from the source: or (2) if the circle drawn in Step I is in all cases at a lower elevation than the source elevation, no further delineation may be required (resulting in the smallest possible minimum separation zone ofa circle with radius X); or (3) if the circle drawn in Step I is in all cases above the elevation of the well, the water shed area or a circle with a radius of 500 feet, whichever is smaller, shall represent the minimum separation zone (resulting in the largest possible minimum separation zone of a circle with a radius of 500 feet). 11.4.2.0 Requirements for Investigation of Potential Hydrogeologic Connections Between Water Sources and Sewage Disposal Fields This subpart applies when a hydrogeologic connection may exist between a sewage system disposal field and a potable water source. These distances listed in Table A & B provide a minimal level of protection for water sources. These distances may be increased or reduced based on site specific data. 11.4.2.0.1 Increasing the Minimum Separation Zone These distances may be increased up to a maximum of 500 feet if a sewage disposal field is discharging upgradient of a water source and to the same unconsolidated, unconfined aquifer from which the water source is withdrawing. 11.4.2.0.2 Reductionof the Minimum Separation Zone These distances may be reduced with the use of site specific data under the following conditions: (a) If there is a continuous impeding layer from the sewage system disposal field to the well head, and the well is properly sealed to prevent contaminant migration along the well casing then the minimum separation zone around the well head may be reduced to a radius of not less than 100 feet; or (b) If the groundwater flow from beneath the sewage system disposal fields is not toward a minimum separation zone around the well head that has a radius of X; or (c) If a detailed hydrogeologic investigation reveals that groundwater flow from beneath the sewage system disposal field does not flow toward the source under pumping conditions the minimum separation zone around the well head may be reduced to a radius of not less than 100 feet; or (d) If a detailed hydrogeologic investigation demonstrates a time of travel exceeding two years in accordance with Subpart 11.4.2.1, then the minimum separation zone around the well head may be reduced to a radius of not less than 100 feet. 11.4.2.1 Two Year Time of Travel If required elsewhere in Subpart 11.4.2. then a minimum travel time of two years must exist in the materials between a potential source of contamination that may contain pathogenic microorganisms and the drinking water source. The two year travel time is based on the reasonable assurance of pathogen attenuation. Calculations of travel time

VERMONT WATER SUPPLY RULE - CHAPTER 21 must take into account hydraulic gradient, porosity, saturated hydraulic conductivities in the materials with the largest saturated hydraulic conductivity, the cone of influence of production wells or the recharge area of springs being considered, and mounding of the water table due to groundwater recharge by discharge of the sewage effluent. 11.4.2.2 Increased Level of Contamination The potential source(s) of contamination may not increase the level of contamination in any drinking water source to more than the Maximum Contaminant Levels (MCL) of the Drinking Water Standards in Subchapter 21-6 of this rule. Nitrate (expressed as N) may be used as an indicator when dealing with domestic (non-industrial) wastes. Calculations must take into account the concentration of nitrate-nitrogen at the base of the leachfield, which is assumed to be 40 mg/l dilution by precipitation and groundwater flow, dispersion, background concentrations of nitrate-nitrogen, and other existing sources of nitrate-nitrogen, including fertilizers, in the subsurface drainage basin, using the assumption that no denitrification takes place in the subsoil. Methods of calculation and evaluation must closely approximate actual conditions and should be determined in consultation with the Agency before any work is done. The minimum separation distances for leachfieids can be also estimated by using methods to define Well Head Protection Areas as contained in Part 3 of this appendix, or with other methods approved by the Agency. 11.5 Well and Spring Construction Standards 11.5.0 Water Well The requirements of this subpart presume that water wells are constructed in compliance with Vermont Water Well Construction Standards. 11.5.1 Spring and Shallow Well Construction 11.5.1.1 Materials Acceptable materials include: (a) (b) (c) (d) concrete tiles; poured in place concrete; well casing; other casing may be approved upon review by the Agency. 11.5.1.2 Site Work Spring and shallow well site construction shall include the following: (a) screened ventilation or overflow openings; (b) surface water diversion berm at least 50 feet upslope when feasible; - (c) back fill material of high clay content sloping away from source; (d) minimum of 4 inches of top soil over the clay; (e) a watertight, rodent-proof sanitary cover.

11.6 Water Quantity Testing