Dewatering Calculations, Treatment and Supporting Documentation
|
|
|
- Claud Shepherd
- 9 years ago
- Views:
Transcription
1 Dewatering Calculations, Treatment and Supporting Documentation I. Purpose AECOM conducted the following activities to determine the best approach for management of water generated during the proposed Interim Remedial Measures (IRM) excavation work. General review of treatment options and selection of methods to test, Pumping and chemistry testing, and Treatability tests completed by USFilter. As discussed in more detail in the following sections, the results of this evaluation indicate that off-site disposal/treatment of water generated during the IRM excavation activities is the best management method. The high concentration of hexavalent chromium in groundwater (3,500 to 9,000 ppm) renders conventional on-site treatment very expensive. Further, plant design, construction, and permitting cannot be completed within the desired timeframe for completion of the excavation phase of IRM#1. However, this option is being evaluated for future remedial activities and pilot tests. II. Review of Treatment Options and Selection of Options to Test In evaluating on-site treatment options, AECOM reviewed previous projects, conducted a general literature search, and held discussions with USFilter. The most commonly used treatment method for concentrated chromium impacted water (either groundwater or plating wastes) is chemical reduction followed by precipitation. Potential reducing agents include sodium bisulfite, hydrosulfite, hydrazine, sulfur dioxide gas, ferrous sulfate, iron filings and other agents. Sodium bisulfite is likely the most commonly used reductant. Sodium bisulfite reduction is used extensively for plating wastes and was recommended for testing by USFilter. Essentially, this process reduces the highly soluble Cr6+ anion complexes to Cr3+ which then forms low solubility complexes/compounds, and the Cr3+ precipitates and is filtered-out. Settling and filtration are the most challenging steps in the process. Ion exchange treatment was also considered for testing. In this process, water bearing Cr6+ is passed through a resin bed that exchanges the Cr6+ complexes for another ion such as chloride or hydroxide. Ion exchange is capable of achieving very low treatment levels and is best suited to relatively low influent concentrations. For the Garfield Ave site, the rate of resin usage would be very high due to the high water table. With an estimated influent hexavalent chromium concentration of 3,500 ppm observed from the pumping test described in the following section, the estimated resin cost for treatment of groundwater in the IRM#1 Area is $4.30/gallon. Thus, ion exchange was ruled out as a viable treatment option for the IRM#1 Area. III. Pumping and Chemistry Testing For treatment testing, groundwater extracted from piezometer PZ-8 was provided to USFilter. Piezometer PZ-8 is located within future proposed IRM excavation area and groundwater samples collected from this piezometer exhibited a high hexavalent chromium concentration (9,250 ppm) and ph (12.2). However, these conditions likely reflect an unrealistic scenario for water conditions expected to be observed for the duration of proposed dewatering activities. In an effort to refine these parameters and thus develop a more realistic cost estimate for on-site treatment, a groundwater extraction test was conducted within future proposed area of remediation. Guidance/Workplans/IRMWP-All Phases /Working Files/2010 IRM1 - Exc half/final IRMWP1/Appendices/Appendix A - Dewater Calcs/2010_ 01_14 App A Dewatering Calcs _FD.doc 1
2 Well Construction Extraction well PW-1 was installed in an area proposed for future proposed remedation, as shown on Figure 1, to a depth of 18 feet. The 4-inch diameter extraction well was constructed and developed to allow accommodation of a 2-inch diameter submersible pump, provide the maximum flow rate, and minimize silt or other solids in the extracted water. Well construction consisted of 3 feet of PVC riser, 15 feet of slot well screen, #1 sand pack and a flushmount road box. Soil logging was performed continuously starting at a depth of 10 feet below grade during installation to ensure that the boring did not penetrate the meadow mat layer. The well was developed until an obvious improvement in turbidity was observed. Two new piezometers were also installed and used as observation wells for the groundwater extraction test. The locations of the piezometers are also shown in Figure 1. Piezometers OW- 1, and OW-2 were installed around well PW-1 at horizontal distances of 5 and 10 feet from well PW-1, respectively. Each new piezometer was installed to a depth of 16 feet. The newlyinstalled piezometers were constructed with 2-inch diameter PVC riser with a 5-foot long well screen (0.010-slot size), medium sand (#1 Morie) filter pack, and flush-mount road box. Form Bs, Well Construction and Boring Logs, and Well Records for the new wells are included at the end of this Appendix. As discussed in the previously submitted IRM Work Plan, subsequent to the groundwater extraction test, these three wells (PW-1, OW-1 and OW-2) were abandoned in June 2007 in preparation for future IRM activities. Extraction Test The extraction test was conducted over a 5-day period. While groundwater was pumped from extraction well PW-1, ph measurements and sampling for chromium were conducted at several points during the test. Drawdown of water levels was measured in nearby wells and piezometers. Analytical results, water level data, and pumping flow rates documented as part of this test are depicted in Tables 1 and 2. Wastes from the drilling activities, which included soil cuttings, well development water, and decontamination water were drummed and disposed off-site. Groundwater extracted as part of the test was stored temporarily in a frac tank on-site, and was subsequently transported off-site for disposal. Disposal documentation will be provided in a future report detailing IRM excavation activities and results. Results Both the ph and chromium concentrations during the pumping test remained elevated throughout the extraction test. Total suspended solids concentrations varied throughout the test. Based upon the results of the extraction test, a hexavalent chromium concentration of 3,500 ppm and a ph of 12 are considered to represent average values for groundwater in the pump test area. In general, these conditions represent a worst-case scenario for groundwater that will be removed during dewatering activities in the 900 Garfield Avenue Slab and 2 Dakota Street Slab IRM areas, where concentrations are typically lower than in the pump test area. Pumping at well PW-1 yielded less than 1 gpm over the course of the test and the area of influence was relatively small (<10-foot radius). Guidance/Workplans/IRMWP-All Phases /Working Files/2010 IRM1 - Exc half/final IRMWP1/Appendices/Appendix A - Dewater Calcs/2010_ 01_14 App A Dewatering Calcs _FD.doc 2
3 IV. Dewatering Calculations The rate of water to be removed during excavation activities was calculated using the results of the pumping test and a simple analytical groundwater flow model. Conceptual Model As the basis for the analytical model, the hydrogeologic conceptual model for the 900 Garfield Avenue Slab IRM area is presented in Table 3. A simple analytical groundwater flow model called WELFLO was used to simulate expected groundwater dewatering rates for the 900 Garfield Avenue Slab IRM Area. This model was published in: Analytical Groundwater Modeling: Flow and Contaminant Migration by William C. Walton, CRC Press, The model allows simulation of pumping wells located at grid nodes in a user-specified grid to predict drawdown or mounding from groundwater extraction or injection, respectively. A series of pumping wells arranged in a rectangular array are used to simulate dewatering from a rectangular-shaped excavation area. The pumping rate of each simulated well is varied until the target drawdown (dewatering) level is achieved. The total pumping rates of all wells are then summed to calculate the total dewatering rate for the simulated excavation under the designated duration or time period. In general, the initial design for the proposed excavation activities in the 900 Garfield Avenue Slab IRM area includes excavation of the upper 10 feet of impacted soil down to the top of the Meadow Mat layer. The actual depth of the Meadow Mat layer may vary, but on average, is approximately 15 feet in most areas beneath 900 Garfield Avenue Slab. However, in the area of the former Morris Canal, located along the southeastern edge of 900 Garfield Avenue Slab, the Meadow Mat layer is missing. In the areas where the Meadow Mat layer is missing, the depth of the excavation will likely extend down to 20 to 25 feet in places. In general, excavations will proceed in strips measuring 20 feet wide and 30 feet long. The anticipated maximum size of an open area of an excavation will be approximately 20 feet by 30 feet. However, due to the need to collect confirmation samples, the actual size of open excavation area may be larger for a short period of time. As soon as the results of confirmation sampling indicate that target soil cleanup levels have been achieved, the completed excavation area will be backfilled with clean fill. In an effort to reduce the amount recharge into the 900 Garfield Avenue Slab IRM area from areas upgradient, a relatively watertight sheet pile wall will be driven along the southeastern side of Garfield Avenue, directly upgradient of 900 Garfield Avenue Slab. The approximate location of the proposed wall is shown in Figure 1. The sheet pile wall will be driven approximately to a depth of 30 feet below grade into an underlying silt unit that is approximately 6 feet thick. Since the WELFLO model is a simple analytical solution, it is unable to simulate the effect of the sheet pile wall, nor the expected flows from the subsurface utility beds below Garfield Avenue. Model Assumptions Based upon the hydrogeologic conceptual model and the initial design of the proposed excavation scheme for the 900 Garfield Avenue Slab IRM area, modeling assumptions and input parameters were selected for the WELFLO model simulations. A summary of the modeling assumptions is presented in Table 4 and the WELFO input parameters are presented in Table 5. The model runs were simulated for a period of 5 continuous work days to generate average weekly dewatering rates. Guidance/Workplans/IRMWP-All Phases /Working Files/2010 IRM1 - Exc half/final IRMWP1/Appendices/Appendix A - Dewater Calcs/2010_ 01_14 App A Dewatering Calcs _FD.doc 3
4 In an effort to evaluate the ranges of dewatering rates that may be expected due to seasonal effects, the model simulated both late summer and early spring conditions. Based on water levels collected at the site over time, low and high groundwater conditions are experienced in the late summer and early spring periods, respectively. For the modeling effort, it was assumed that the dewatering level (thickness of the saturated zone to be dewatered) varied from 5 to 10 feet in locations outside of the former Morris Canal and from 15 to 20 feet in the former Morris Canal of the 900 Garfield Avenue Slab (see Table 4). Not surprisingly, the fine-grained nature of the fill material in the shallow aquifer beneath the 900 Garfield Avenue Slab IRM area results in a relatively low aquifer permeability. As previously discussed, the measured hydraulic conductivity (K) of this material ranges from 1 to 3 ft/d. Previous numerical modeling efforts (using MODFLOW) suggest that a K = 1.5 ft/d provides a good match between observed and simulated heads. The pumping test results conducted in the area proposed for future remediation indicate a K = 3 ft/d. Therefore, the WELFLO modeling effort used a range of K values (1.5 and 3 ft/d) to predict dewatering rates. Model Results As expected, the simulated dewatering rates varied depending upon aquifer permeability, season, and location (inside or outside of the former Morris Canal). The majority of the 900 Garfield Avenue Slab IRM area is outside of the former Morris Canal, and predicted weekly dewatering rates in this area varied from 4,320 to 7,776 gpd in the summer versus 8,640 to 15,552 in early spring. In areas within the former Morris Canal, the predicted dewatering rates varied from 12,960 to 23,328 gpd in late summer versus 17,280 to 31,104 gpd in early spring. Since the K=3 ft/d dewatering rates are more conservative, these rates should be used for design purposes. A summary of the WELFLO dewatering modeling results is presented in Table 6. The WELFLO output screens are presented as an attachment to this appendix. V. Treatability Testing USFilter conducted a series of tests on groundwater collected from well PZ-8 to evaluate the most appropriate process to reduce chromium concentrations in the groundwater to below 0.1 ppm. The selected process consisted of the following: Reduce ph to with sulfuric acid Reduce chromium with sodium bisulfite Increase ph with lime to 10.3 Add flocculating agent Settle for one hour and filter (separation method for full-scale treatment may include settling tanks, conventional filtration of microfiltration) The estimated cost for chemicals and sludge disposal using the data provided during the extraction test is $0.14/gallon. The estimated cost for plant operation, utilities, and discharge fees is $0.30/gallon. Thus, the cost to treat water removed during the IRM is approximately $0.44/gallon. USFilter estimates the cost to design and install a 17 gpm plant is approximately $500,000 to $750,000. Because of the high chemical demand and poor economics of the conventional sodium bisulfite treatment, USFilter experimented with other processes. Those tests included: Sodium bisulfite treatment at higher ph values as ph increased, sodium sulfite demand increased Guidance/Workplans/IRMWP-All Phases /Working Files/2010 IRM1 - Exc half/final IRMWP1/Appendices/Appendix A - Dewater Calcs/2010_ 01_14 App A Dewatering Calcs _FD.doc 4
5 Hydrogen peroxide treatment not effective in meeting chromium treatment goal Hydrosulfite treatment not effective at meeting chromium treatment goal Use of sodium hydroxide to increase ph during treatment process treated water did not settle out Hydrazine treatment effective at higher ph (additional study needed) Magnetic separation total suspended solids appear too high for efficient use of this technology VI. Conclusions For the IRM work, minimizing the generation of water by extending relatively watertight sheet piling along Garfield Avenue and off-site disposal of water is recommended. It is estimated that the cost of off-site disposal/treatment of extracted water from the 900 Garfield Avenue Slab IRM area would be $0.62/gallon ($1.12MM per 1,800,000 gallons). The cost of a conventional sodium bisulfite treatment system is approximately $500,000 to $750,000 for construction plus $0.44/gallon for treatment (total cost $1.29MM to $1.54MM). Onsite treatment and discharge to municipal sewer is currently being evaluated for future remedial activities including a potential full site remediation at a later date. Because the sewer system in Jersey City is a combined system, provision to store groundwater onsite is required during and up to 24 hours following a rain event. Proceeding with onsite treatment would also result in schedule delays related to permitting the facility with the PVSC and plant construction; however, the proper permits and treatment options are being pursued. Thus, comparing treatment options, costs, and potential scheduling and permitting issues, off-site disposal of dewatering water will be initially utilized for the 900 Garfield Avenue Slab IRM. Guidance/Workplans/IRMWP-All Phases /Working Files/2010 IRM1 - Exc half/final IRMWP1/Appendices/Appendix A - Dewater Calcs/2010_ 01_14 App A Dewatering Calcs _FD.doc 5
6
7 Table 1 Groundwater Levels and Pumping Rates During Extraction Test Privileged and Confidential Attorney-Client Communication Attorney Work Product Prepared at Request of Counsel Notes Date Pre-Extraction Test 8/14/2006 Pre-Extraction Test 8/15/2006 After 21 hrs. 8/16/2006 After 25 hrs. 8/16/2006 After 43 hrs 8/17/2006 After 50 hrs 8/17/2006 After 72 hrs 8/18/2006 After deactivation 8/18/2006 After 3 day recovery 8/21/2006 Weather Sunny Light rain in AM Sunny Sunny Sunny Sunny Overcast and wind Sunny and breezy Well ID DTW (ft) Time DTW (ft) Time DTW (ft) Time DTW (ft) Time DTW (ft) Time DTW (ft) Time DTW (ft) Time DTW (ft) Time DTW (ft) Time MW6A : : : : : :55 MW11A : : : : : : :50 PZ : : : : : : :32 PZ : : : : : : :43 PZ : : : : : : :46 PZ : : : : : : :27 PW : : : : : : : : :39 OW : : : : : : : : :38 OW : : : : : : : : :37 Frac Tank water depth (ft) : : : : :55 Est'd volume in tank (gal.) Measured Flow Rate (gpm) : : : :48 Approx. Avg. flow rate Measured Flow Rate (gpm) = measured with bucket and stopwatch Approx. Avg. flow rate = flow rate based upon (Est'd volume in tank) / (number of minutes test has run)
8 Table 2 Analytical Results During Extraction Test Privileged and Confidential Attorney-Client Communication Attorney Work Product Prepared at Request of Counsel Sample ID Sample Date Analysis Result Reporting Limit Unit PT-INIT 8/15/2006 Total Suspended Solids mg/l PT-INIT 8/15/2006 Chromium ug/l PT-INIT 8/15/2006 Chromium VI (7196A) ug/l PT-INIT 8/15/2006 ph SU PT-21HR 8/16/2006 Total Suspended Solids mg/l PT-21HR 8/16/2006 Chromium ug/l PT-21HR 8/16/2006 Chromium VI (7196A) ug/l PT-21HR 8/16/2006 ph SU PT-41HR 8/17/2006 Total Suspended Solids U 10 mg/l PT-41HR 8/17/2006 Chromium ug/l PT-41HR 8/17/2006 Chromium VI (7196A) ug/l PT-41HR 8/17/2006 ph SU PT-72HR 8/18/2006 Total Suspended Solids mg/l PT-72HR 8/18/2006 Chromium ug/l PT-72HR 8/18/2006 Chromium VI (7196A) ug/l PT-72HR 8/18/2006 ph SU INIT - collected at initiation of pumping 21HR - collected after 21 hours of pumping 41HR - collected after 41 hours of pumping 72HR - collected after 72 hours of pumping (test terminus) Guidance/Workplans/IRM WP -Phase I Excavation/IRMWP Appendix C Extraction Test/Analytical data summary.xls
9 Table 3. Hydrogeologic Conceptual Model for 900 Garfield Avenue Slab IRM Area Description Value Ground Surface Elevation: Average groundwater elevation (late summer): Average depth to water (late summer): Average groundwater elevation (early spring): Average depth to water (early spring): Bottom of aquifer elevation (top of 2 silty-clay unit): Aquifer thickness: Aquifer Hydraulic conductivity: 15 ft amsl 9 ft amsl 6 ft 13 ft amsl 2 ft -2 ft amsl 11 to 15 ft 1.5 to 3 ft/d Aquifer Specific Yield 0.1 Amsl = above mean sea level Table 4. WELFLO Modeling Assumptions for 900 Garfield Avenue Slab IRM Area Description Aquifer type Maximum excavation area open at any one time Target saturated zone dewatering interval (outside Morris Canal Area in late summer): Target saturated zone dewatering interval (outside Morris Canal Area in early spring): Target saturated zone dewatering interval (inside Morris Canal Area in late summer): Target saturated zone dewatering interval (inside Morris Canal Area in early spring): Starting aquifer thickness: Value water table that is homogeneous and isotropic 20 ft x 30 ft 5 ft 10 ft 15 ft 20 ft 20 ft Aquifer hydraulic conductivity: 1.5 to 3 ft/d Aquifer specific yield 0.1 Wells for dewatering simulation Duration of dewatering period fully penetrate the designated aquifer thickness Assumed 5-day construction work week to generate an average weekly dewatering rate PRIVILEGED AND CONFIDENTIAL. ATTORNEY CLIENT PRIVILEGED. PREPARED AT THE REQUEST OF COUNSEL. Guidance/Workplans/IRMWP-All Phases /Working Files/2009 IRMWP/Appendices/Appendix B - Dewatering Calcs/2010_ 01_14 App B Dewatering Calcs_ID.doc
10 Table 5. WELFLO Model Input Parameters for 900 Garfield Avenue Slab IRM Area Description Value Aquifer type water table Well type Fully penetrating wells with no wellbore storage Number of simulation periods 1 Duration of simulation period 5 days # of grid columns 10 # of grid rows 10 Grid spacing 10 ft x-coordinate of upper left grid node 10 y-coordinate of upper left grid node 10 # of production wells for simulation 12 Coordinates of production wells (3 rows of 4) 30, 40-60,40 then 30,50 60,50 then 30,60 60,60 Well discharge Varies from 0.25 gpm to 1.8 gpm Duration of pump operation during simulation 5 days Well radius 0.3 ft # of observation wells 0 Aquifer transmissivity gpd/ft for K = 1.5 ft/d gpd/ft for K = 3.0 ft/d Aquifer specific yield 0.1 Note: Used screen capture program to capture output of drawdowns at each grid node. PRIVILEGED AND CONFIDENTIAL. ATTORNEY CLIENT PRIVILEGED. PREPARED AT THE REQUEST OF COUNSEL. Guidance/Workplans/IRMWP-All Phases /Working Files/2009 IRMWP/Appendices/Appendix B - Dewatering Calcs/2010_ 01_14 App B Dewatering Calcs_ID.doc
11 ATTACHMENT 1 MODEL RESULTS AND WELFLO OUTPUT SCREENS
12 Table 6 PPG Garfield Avenue Site 114 Summary of Dewatering Calculations for 900 Garfield Avenue Slab IRM Area K = 1.5 ft/d K = 3 ft/d Notes: Excavation Dimensions Season Inside or Outside Morris Canal Area Target Dewatering Interval (feet) Average Dewatering Rate Over 5-Day Period* Average Dewatering Rate Over 5-Day Period* (gpm) (gpd) (gpm) (gpd) 20' x 30' late summer outside ' x 30' early spring outside ' x 30' late summer inside ' x 30' early spring inside It is assumed that the intial water levels are 5 feet higher on average in early spring than in late summer. * It is assumed that dewatering is continuous over a 5-day work week. 2010_01_14 Table_6_Dewatering Calcs Summary_ID 1 of 1 January 2010
13
14
15
16
17 ATTACHMENT 2 WELL ABANDONMENT REPORTS
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM
STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM Solid Waste Management Program Waste Management Division 103
COST AND PERFORMANCE REPORT
COST AND PERFORMANCE REPORT Pump and Treat of Contaminated Groundwater at the United Chrome Superfund Site Corvallis, Oregon September 1998 Prepared by: SITE INFORMATION Identifying Information: United
Removing Heavy Metals from Wastewater
Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides
California Department of Transportation Doyle Drive Test Program Contract No. 04A3362
California Department of Transportation Doyle Drive Test Program Deep Soil Mixing (DSM) /Cutter Soil Mixing (CSM) Testing Report By Malcolm Drilling Company, Inc. 3524 Breakwater Ave., Suite 108 Hayward,
CHAPTER 4 WELL COMPLETION AND MAINTENANCE
CHAPTER 4 WELL COMPLETION AND MAINTENANCE Section 1: Disinfection. (a) Each person who repairs, modifies, works on, or otherwise affects the physical components of a well shall clean and disinfect the
DEPARTMENT OF ENVIRONMENTAL REGULATION. Technical Document DETERMINING REPRESENTATIVE GROUND WATER SAMPLES, FILTERED OR UNFILTERED
DEPARTMENT OF ENVIRONMENTAL REGULATION Technical Document DETERMINING REPRESENTATIVE GROUND WATER SAMPLES, FILTERED OR UNFILTERED JANUARY 1994 BUREAU OF DRINKING WATER AND GROUND WATER RESOURCES 2600 BLAIR
Ion Exchange Softening
Ion Exchange Softening Ion-exchange is used extensively in small water systems and individual homes. Ion-exchange resin, (zeolite) exchanges one ion from the water being treated for another ion that is
U. S. Army Corps of Engineers Ground Water Extraction System Subsurface Performance Checklist
U. S. Army Corps of Engineers Ground Water Extraction System Subsurface Performance Checklist Installation Name Site Name / I.D. Evaluation Team Site Visit Date This checklist is meant to aid in evaluating
Dewatering - Time and Cost Relief by way of Trenchless Construction
North American Society for Trenchless Technology (NASTT) NASTT s 2015 No-Dig Show Denver, Colorado March 15-19, 2015 TA-T3-04 Dewatering - Time and Cost Relief by way of Trenchless Construction Jenn Stillman,
State of Rhode Island Department of Environmental Management Division of Site Remediation. Policy Memo 95-01
State of Rhode Island Department of Environmental Management Division of Site Remediation Policy Memo 95-01 Guidelines for the Management of Investigation Derived Wastes 1.0 Purpose The purpose of this
How To Water System
Mid-Monroe Water System: Soluble Iron and Manganese Removal via Oxidation & Filtration Daniel Rickard, P.E. Engineering Project Manager Pennsylvania-American Water Company Who Is American Water We are
SOIL AND GROUNDWATER MANAGEMENT PLAN For Site Located at 420 South Avenue Rochester, New York NYSDEC Spill No. 1000563 PREPARED FOR: PREPARED BY:
SOIL AND GROUNDWATER MANAGEMENT PLAN For Site Located at 420 South Avenue Rochester, New York NYSDEC Spill No. 1000563 PREPARED FOR: FLOWER CITY MANAGEMENT & DEVELOPMENT THE MEDICAL ARTS BUILDING (USGBC
Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia
Georgia Department of Public Health Georgia Onsite Sewage Management Systems Background and Use of Onsite Wastewater Treatment Systems in Georgia Background On-site sewage management systems are designed
Iron and Manganese BACTERIA AND IRON AND MANGANESE
Iron and Manganese Iron and manganese control is the most common type of municipal water treatment in Minnesota. Iron and manganese occur naturally in groundwater. Neither element causes adverse heath
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems What every homeowner should know about living with a well and a private sewage system. YOUR ENVIRONMENTAL SYSTEMS Out of sight out of
Guidelines For Sealing Groundwater Wells
Guidelines For Sealing Groundwater Wells Government of Newfoundland and Labrador Department of Environment and Conservation Water Resources Management Division Government of Newfoundland and Labrador Department
Environmental Technology March/April 1998
Treating Metal Finishing Wastewater Sultan I. Amer, Ph.D. AQUACHEM INC. Environmental Technology March/April 1998 Wastewater from metal finishing industries contains high concentrations of contaminants
Specifications For Rehabilitation Hudson #1A Hudson #2 Foster Island Well #41
Specifications For Rehabilitation Hudson #1A Hudson #2 Foster Island Well #41 ITEM #6 1) Scope of Work The scope of this proposal is: Hudson Street Well #1A and Hudson Street Well #2 - clean and rehabilitate,
Appendix B: Water Treatment Scenarios from AMD Treat
Appendix B: Water Treatment Scenarios from AMD Treat 103 of 104 Jeddo Tunnel Abandoned Mine Drainage Passive vs. Active Treatment Cost Estimates Provided by Office of Surface Mining AMD Treat Software
Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities
Water Efficiency Water Management Options Boilers for Commercial, Industrial and Institutional Facilities Boiler Water Impurities All boiler make-up water contains impurities. As clean steam is released
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
Water remediation: Passive Treatment Technologies
Presenter: Jacques Meyer Project design: Adrian Haagner, Piet Smit & Jacques Meyer Water remediation: Passive Treatment Technologies Using a sub-surface flow wetland on a rehabilitated decommissioned coal
INFORMATION SHEET ORDER NO. R5-2011-XXXX TRIANGLE ROCK PRODUCTS, INC. FLORIN ROAD AGGREGATE PLANT SACRAMENTO COUNTY
ORDER NO. R5-2011-XXXX INFORMATION SHEET Background Triangle Rock, Inc. (Discharger) submitted a Report of Waste Discharge (RWD) on 23 August 2010. The Discharger is expanding the mining operations at
STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
Louisiana Administrative Code Title 51 Part XIII. Sewage Disposal
Louisiana Administrative Code Title 51 Part XIII. Sewage Disposal Regulations Regarding Septic Tank Installations with Field Beds/Absorption Trenches For Individual Residential Installations Chapter 3.
GROUND WATER CONTAMINATION INFORMATION
Ohio Department of Natural Resources Division of Oil and Gas Resources Management GROUND WATER CONTAMINATION INFORMATION Presence of Salty Water The salt that is normally found in contaminated water wells
CHAPTER 2 HYDRAULICS OF SEWERS
CHAPTER 2 HYDRAULICS OF SEWERS SANITARY SEWERS The hydraulic design procedure for sewers requires: 1. Determination of Sewer System Type 2. Determination of Design Flow 3. Selection of Pipe Size 4. Determination
Treatment options for hydrogen sulfide. Testing for hydrogen sulfide
Sometimes hot water will have a sour smell, similar to that of an old damp rag. This smell often develops when the thermostat has been lowered to save energy or reduce the potential for scalding. Odor-causing
PERC-RITE DRIP DISPERSAL DESIGN GUIDE FOR SEPTIC TANK OR ADVANCED TREATMENT EFFLUENT MAINE
PERC-RITE DRIP DISPERSAL DESIGN GUIDE FOR SEPTIC TANK OR ADVANCED TREATMENT EFFLUENT MAINE This Perc-Rite Design Guide is intended to simplify the design process of a Perc-Rite Drip Dispersal System. This
Nutrient Reduction by Use of Industrial Deep Injection Wells, Miami-Dade County, Florida
GWPC September 27, 2015 Nutrient Reduction by Use of Industrial Deep Injection Wells, Miami-Dade County, Florida Virginia Walsh, PhD, P.G. Miami-Dade Water and Sewer Department Ed Rectenwald, P.G. MWH
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media ASME Research Committee Power Plant and Environmental Chemistry Overland Park, Kansas April 2-4, 2007 Prepared by: W. H. Stroman Primary
ources of Drinking Water
The drop on water Sources of Drinking Water Did you know that 40 per cent of Nova Scotians get their water privately from a drilled well, a dug well, or a surface water source? The other 60 per cent rely
TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL
TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL SCOPE This section of the specifications includes requirements for the Slurry Trench Cutoff Wall and related work as indicated on the
Appendix D.1. Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils
Appendix D.1 Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils General Notes Pertinent to All Testing 1. For infiltration trench (I-1) and basin (I-2) practices, a minimum field
Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems
Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems The septic tank-absorption field sewage treatment system is composed of two major elements; the
Technical Support Services Accelerated Learning Through the Visual Presentation of Technical Information
TSS Module 11 Waste Neutralization pdf documents Text in pdf documents may appear fuzzy or blocky due to file compression. To change the appearence in Acrobat TM Reader TM 3.X, go to the menu item: File
Design Criteria & Service Goals
4.1 Design Life of Improvements The design life of a water system component is sometimes referred to as its useful life or service life. The selection of a design life is a matter of judgment based on
Guidelines for Precast Concrete Grease Interceptors
Guidelines for Precast Concrete Grease Interceptors Purpose Provide an overview of the basic design principals that govern why gravity grease interceptors work Provide a forum for discussion of common
14.330 SOIL MECHANICS Assignment #4: Soil Permeability.
Geotechnical Engineering Research Laboratory One University Avenue Lowell, Massachusetts 01854 Edward L. Hajduk, D.Eng, PE Lecturer PA105D Tel: (978) 94 2621 Fax: (978) 94 052 e mail: [email protected]
WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )
Page 1 of 76 1.0 PURPOSE The purpose of the Wastewater Treatment System is to remove contaminates from plant wastewater so that it may be sent to the Final Plant Effluent Tank and eventually discharged
MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES
MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES John van Rijn INDEVELOPMENT MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES Any part of this publication may be
Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
CREATING A GREEN FUTURE THROUGH WATER REMEDIATION
CREATING A GREEN FUTURE THROUGH WATER REMEDIATION Cornerstone Principles for Conducting Business Active Treatment Systems, Inc. goes to great lengths to instill in every employee the importance of ethical
Septic System Owner s Manual
Septic System Owner s Manual Sponsored by: copyright 2013 No part of this publication may be reproduced without our consent. www.callbrownies.com Brownie s Septic and Plumbing has provided quality service
SECTION 10 WATER WELL SUPPLY 10.01 SCOPE OF WORK
10.01 SCOPE OF WORK The work covered by this section of the specifications consists in furnishing all labor, equipment and material necessary to perform the installation of a Type I water supply well per
Coagulation and Flocculation
Coagulation and Flocculation Groundwater and surface water contain both dissolved and suspended particles. Coagulation and flocculation are used to separate the suspended solids portion from the water.
Determining Actual Aquarium Volume
Name Period Date Determining Actual Aquarium Volume Objective The learner will explore the factors that affect the actual volume of an aquarium. The learner will calculate the actual volume of the classroom
http://septic.umn.edu
for Holding Tank Systems The goal of a septic system is to protect human health and the environment by properly treating wastewater before returning it to the environment. Your holding tank system is designed
Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System
Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System An application for the construction or alteration of an individual subsurface sewage disposal system shall
Marcellus Fast Facts
1 Marcellus Fast Facts Covers about 95,000 square miles in 6 states Occurs at depths of up to 9,000 feet Thickness of 250 feet or more Largest natural gas reservoir in North America (est. 500 TCF recoverable
Residuals Management Somersworth Drinking Water Treatment Facility. Ian Rohrbacher, Treatment Operator IV
Residuals Management Somersworth Drinking Water Treatment Facility A HISTORICAL OVERVIEW OF SURFACE WATER TREATMENT RESIDUALS HANDLING Ian Rohrbacher, Treatment Operator IV Background We are a Grade III
DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS
DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS Phase I MS4 permits require continuous updating of the stormwater system inventory owned and operated by the MS4. They also include inspection
Northeast Tri County Health District
Northeast Tri County Health District Standards and Guidance for Performance, Application, Design, and Operation & Maintenance Holding Tank Sewage System Based on the Washington State DOH of Health Recommended
Soil depth: meters Type of restrictive layer:
Job Name: Date: Designer: Sand mound design worksheet UNITS: Liters and Meters See diagrams page 6, below for dimension letters. See pressure distribution worksheet for conversions. A. DESIGN INPUTS, FLOW
Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System
River Treatment for Ultrapure Production A cost-effective and environmentally-sound solution Abstract New Logic International installed its Vibratory Shear Enhanced Processing (VSEP) Phase I system in
Saudi Aramco Project Development
Saudi Aramco Project Development Wastewater Treatment Facilities Jeddah Refinery And Marine Area December 2007 Facilities Planning Dept. OBJECTIVE: Provide an overview of the complexities of developing
Water Supply and Wells
Re-issued under new categorization in August 2009 as Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-4 Buildings Department Practice Note
Ground Water in the Piedmont and Blue Ridge Provinces of North Carolina
Ground Water in the Piedmont and Blue Ridge Provinces of North Carolina Prepared by: R.L. Huffman Extension Agricultural Engineering Specialist Published by: North Carolina Cooperative Extension Service
APPENDIX G SETTLEMENT
APPENDIX G SETTLEMENT TABLE OF CONTENTS G.1 IN T R O D U C T IO N... 1 G.2 MATERIAL PLACEMENT AND COMPACTION... 1 G.2.1 Incom pressible M aterials... 1 G.2.2 Compressible Materials... 2 G.2.3 Soil P lacem
Principles of groundwater flow
Principles of groundwater flow Hydraulic head is the elevation to which water will naturally rise in a well (a.k.a. static level). Any well that is not being pumped will do for this, but a well that is
Underground Injection Control Storm Water Information
Underground Injection Control Storm Water Information Best Management Practices DEQ has reviewed the EPA definition of a subsurface fluid distribution system and the infiltration design best management
Laboratory and Field Performance Assessment of Geocomposite Alternative to Gravel Drainage Overliner in Heap Leach Pads
Laboratory and Field Performance Assessment of Geocomposite Alternative to Gravel Drainage Overliner in Heap Leach Pads Aigen Zhao, PhD, PE, GSE Environmental, LLC, USA Mark Harris, GSE Environmental,
DEIONIZATION IN A "NUT SHELL"
Deionized Water (DI) DEIONIZATION IN A "NUT SHELL" City water is passed through dark amber colored, caviar sized plastic beads called cation ion exchange resin. The cation resin is in the hydrogen form
GUIDELINES FOR LEACHATE CONTROL
GUIDELINES FOR LEACHATE CONTROL The term leachate refers to liquids that migrate from the waste carrying dissolved or suspended contaminants. Leachate results from precipitation entering the landfill and
CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER
CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER There are a number of technologies that are being use to remediate contaminated groundwater. The choice of a certain remediation technology
CHECKLIST FOR FILING AN APPLICATION FOR A GROUND AND/OR SURFACE WATER WITHDRAWAL PROJECT IN THE DELAWARE RIVER BASIN
CHECKLIST FOR FILING AN APPLICATION FOR A GROUND AND/OR SURFACE WATER WITHDRAWAL PROJECT IN THE DELAWARE RIVER BASIN PLEASE COMPLETE CHECKLIST AND ENCLOSE WITH THE APPLICATION. If you need assistance,
FY08 SEWER POINT REPAIRS BID TABULATION
6-07-831 Page 1 of 12 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING "
Preventing Basement Flooding
Preventing Basement Flooding Perry Lindquist Land Resources Manager Waukesha County Dept. of Parks & Land Use Waukesha County Storm Water Workshop April 10, 2013 Presentation Outline Background Case study
MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION
MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION Moser and Associates Engineering for CDOT Region 6 Date: 9/30/10 Memorandum to File: Recommendations for Pipe Material Selection for Construction
GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION
GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION Prepared by: Purolite International Date: November 2003 Operating Puropack Plant 2 GUIDELINES FOR SELECTING
CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM
CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM OTCO Water Workshop March, 2011 Frank Woyma Plant Manager Nick Pizzi Vice-President EE&T ENVIRONMENTAL ENGINEERING & TECHNOLOGY, INC. Objectives Review the
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
Wastewater Reuse. Typical treated wastewater is:
Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution
MARYLAND DEPARTMENT OF THE ENVIRONMENT 1800 Washington Boulevard Baltimore Maryland 21230-1719 1-800-633-6101 http://www.mde.state.md.
MARYLAND DEPARTMENT OF THE ENVIRONMENT 1800 Washington Boulevard Baltimore Maryland 21230-1719 1-800-633-6101 http://www.mde.state.md.us Colonial Pipeline Dorsey Junction Facility 929 Hood s Mill Road,
Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.
Water Softeners Industrial Water Purification (800) CAL-WATER By Dave Peairs, Cal Water, Technical Director Rev: 06/08/2004 Before any discussion of water softeners, we must first define what hard water
WISCONSIN WASTEWATER OPERATORS ASSOCIATION
Integrity. People. Knowledge. WISCONSIN WASTEWATER OPERATORS ASSOCIATION ANNUAL CONFERENCE GREEN BAY Resources. MEETING LOW LEVEL PHOSPHORUS LIMITS BY CHEMICAL ADDITION WHAT IS PHOSPHORUS Atomic # 15 Electron
Environmental Remediation Examples and Remediation Strategic Planning
Environmental Remediation Examples and Remediation Strategic Planning Yasuo Onishi ([email protected]) October 16, 2011 Pacific Northwest National Laboratory, and Washington State University, Civil
Construction sites are dewatered for the following purposes:
9. DEWATERING CONTROL OF GROUNDWATER Construction of buildings, powerhouses, dams, locks and many other structures requires excavation below the water table into water-bearing soils. Such excavations require
Presented by: Craig Puerta, PE, MBA December 12, 2012
Presented by: Craig Puerta, PE, MBA December 12, 2012 Established in 2010 under charter from New York State to transfer lower priority sites from State s program. First municipally-run brownfield cleanup
Texas Commission on Environmental Quality Page 1 Chapter 217 - Design Criteria for Domestic Wastewater Systems
Texas Commission on Environmental Quality Page 1 217.31. Applicability. SUBCHAPTER B: TREATMENT FACILITY DESIGN REQUIREMENTS 217.31-217.39 Effective August 28, 2008 This subchapter details the design values
TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES
TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES JOHN F. BOSSLER, SIEMENS Water Technologies Corp., Hoffman Estates, IL RONALD TRAVIS, SIEMENS Water Technologies
Wastewater Collection Practice Test #3 Page 1 of 15
Wastewater Collection Practice Test #3 Page 1 of 15 1) A 54 in. storm sewer flowing half full, at a velocity of 1.35 Ft./sec., will discharge how much flow into a creek in MGD? 13.85 MGD 10.73 MGD 1.85
CHAPTER 13 LAND DISPOSAL
CHAPTER 13 LAND DISPOSAL Supplemental Questions: Which of Shakespeare's plays is the source of the opening quote? The Tempest [1611-1612],Act: I, Scene: i, Line: 70. 13-1. Cite four reasons landfills remain
Mark A. Lehar, P.Geo. Regional Environmental Lead and Senior Environmental Geologist
Mark A. Lehar, P.Geo. Regional Environmental Lead and Senior Environmental Geologist Exova Seminar: 15 January 2016 HYDRASleeve TM Focused Sampling - Monitoring Well Sampling Using No Purge HYDRASleeves
Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology
Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology TAB0411 Typical crossflow cooling tower installation Due to the large air-water interface needed to obtain good evaporative
Well gauging results LNAPL in Benzol Processing Area
Well gauging results LNAPL in Benzol Processing Area 3.59 ft 0.62 ft 4.64 ft Context Scope & Methods Onshore Results Offshore Results Summary & Conclusions 13 Page 1 of 4 Underground Storage Tanks Last
Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources
Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources Matthew L. Haikalis Veolia Water Solutions & Technologies April 24, 2013 Operational Priorities
Shale Energy Fluids Management Practices
Shale Energy Fluids Management Practices Forum on Hydraulic Fracturing Bogota, Colombia, December 1, 2014 Presented by Dave Yoxtheimer, PG Hydrogeologist Penn State Marcellus Center for Outreach and Research
for Sediment Removal desired levels. The filtered water then can be chemically treated to ensure its safety. Municipal water Preliminary settling
Treating Water for Sediment Removal J.R. Miner Lakes, ponds, and streams are important sources of water for many farms, rural camps, and households as well as for many municipalities in Oregon. Even under
Water Water Treatment Plant Tour
Water Water Treatment Plant Tour Don Rankin, Superintendent Topeka, KS 66606 785-368-3111 Tel 785-368-3825 FAX For a complete list of contacts with phone numbers, FAX numbers and email addresses, click
Retention/Irrigation. Design Considerations. Soil for Infiltration Area Required Slope Environmental Side-effects
Description Retention/irrigation refers to the capture of stormwater runoff in a holding pond and subsequent use of the captured volume for irrigation of landscape of natural pervious areas. This technology
ABC & C 2 EP Formula/Conversion Table for Water Treatment, Distribution, & Laboratory Exams
ABC & C EP Formula/Conversion Table for Water Treatment, Distribution, & Laboratory Exams Alkalinity, as mg CaCO 3 /L = (Titrant, ml) (Acid Normality)(50,000) Sample, ml Volts Amps = Ohms * of Circle =
THE NWF WATER PURIFICATION PROCESS FRESH WATER IN A NATURAL WAY. Esko Meloni Ferroplan Oy
THE NWF WATER PURIFICATION PROCESS FRESH WATER IN A NATURAL WAY Esko Meloni Ferroplan Oy 1 The NWF Water Purification Process: list of contents 1. NWF biological purification of groundwater Iron and manganese
SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.
SEPTIC SYSTEMS Who Has A Septic System? Approximately 30 percent of Connecticut s population is served by on-site subsurface sewage disposal systems (a.k.a. septic systems). This means a large percentage
1.34 WASTE CONTAINMENT AND SITE REMEDIATION TECHNOLOGY TAKE-HOME FINAL EXAM DUE FRIDAY MAY 7, 2004 AT 9:30 AM
1.34 WASTE CONTAINMENT AND SITE REMEDIATION TECHNOLOGY TAKE-HOME FINAL EXAM DUE FRIDAY MAY 7, 2004 AT 9:30 AM This is an open-book exam, but the work should be yours alone. Please do not work with others
Remediation of Sodium Contaminated Sites
Remediation of Sodium Contaminated Sites Environmental Challenges and Innovations Conference: Gulf Coast 2007 Mark Landress P.G. Project vigator, Ltd. 10497 Town & Country Way Suite 830 Houston, TX 77024