Combustible Gas Leak Detector 720b



Similar documents
EzFlex Combustible Gas Leak Detector Model EZ40

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Global Water Instrumentation, Inc.

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Light Meter (Foot Candles)

Operating Instructions MA 27

Mold Alert... Operation Manual P0270

AD-01 Slave Auto Dialer. Owner s Manual

Manual for Fire Suppression & Methane Detection System

DSM155 Digital LED Light Meter User s Manual DSM155

ER102. Emergency Crank Weather Radio Owner s Manual.

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

ExStik TM ph Waterproof Meters


User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Wireless Home Security Alarm System AM 500

CoolDrive 5. User s Manual

SINGLE RANGE DS METERS Operation Instructions

Gold Century GC-1023 Metal Detector

CT-001, CT-001-Solar Owner s Manual

Xi-Sign 4400 User Manual

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

SETTING UP YOUR 6000 SERIES TIME RECORDER

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Owner s Manual & Safety Instructions

Bottom Loading Water Dispenser

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

3 WATT LED SPOTLIGHT Model No. SLM

GAS SAFETY PRECAUTIONS

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model ABOUT THIS ALARM

Operating Manual Color Changing Fountains

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

900 MHz Lightweight Wireless Stereo Headphones

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Owner s Manual & Safety Instructions

Automatic Phone-Out Home Monitoring Systems

INSTRUCTION MANUAL DTH Fax: (503)

HAND CRIMP TOOL Specification Sheet Order No

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Tracking Key II User s Guide.

Microwave Meter. Instruction Manual

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Mini-led spotlight with magnetic base

3. Enter the first five digits of desired frequency ( for MHz).

Electric Egg Boiler. Instruction Manual. Model Number: AEB-917

ROTOR LOADER OWNER S MANUAL

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Instruction Manual. A50099 Calibration Device. TIE-DEX CALIBRATION DEVICE A50099

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Advantium 2 Plus Alarm

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Operators Manual SOIL COMPACTION TESTER

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Operating Guide Manuel de l utilisateur

Models CT-001, CT-002 Owner s Manual

TV Ears 5.0 Digital & Dual Digital Quick Start Guide

Operating instructions Cordless K impact wrench

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Dual Laser InfraRed (IR) Thermometer with Color Alert

Installation and Operation Guide PD4600 Series Converter Replacement

Troubleshooting Guide for Dispenser Model #900172

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

IR Repeater. Operation Manual P8620

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

GOLD DIGGER TREASURE DETECTOR. Owner s Manual

Quick start guide smart.power smart.power smart.power

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos , and

Owner s Manual Attention! Please Read First

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Acrylic Walls Installation Instructions

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

7 High-Resolution Digital Photo Frame

CINEMATE 1 SR DIGITAL HOME THEATER SPEAKER SYSTEM. Operating Guide Guía del usuario Guide d utilisation

Intelli-Time Alarm Clock model 13027

WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm.

User Manual (English)

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Gyration Ultra Cordless Optical Mouse. User Manual

Remote Control Repeater

PALLET JACK TON

Installation Instructions

Natural Gas Emergencies

TWO BURNER PROPANE CAMPING STOVE

TABLE OF CONTENTS 11.0 WARRANTY

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Digital Fingerprint safe

MODELS 93/693 By CO2 SEMI-AUTOMATIC

Transcription:

Combustible Gas Leak Detector 720b The Value Leader TM

Contents Specifications Product Features Standard Accessories Optional Accessories General Description Operating Instructions Battery Replacement Operation Check Sensor Replacement Warranty Specifications Power Supply: 2 "C" Alkaline Batteries Sensor: Solid State Sensitivity: 10 ppm Methane Warm up: Approx 1 minute Response time: Instantaneous Duty Cycle: Continuous Battery Life: Approx. 30 hrs. Size: 3.0" x 9.5" x 1.75" (77 x 240 x 47) mm Weight: 1.1 lbs (500g) Probe Length: 16" (406mm) 0.561.8187

Speaker On/Off switch Sensor Visual leak indicator Gooseneck Earphone jack Battery Compartment Standard Accessories Sensor: A739 Instruction Manual: 720b Instruction Manual Soft Pouch A700 Optional Accessories Hard Case A714 Earphone A710

General Description The 720b is an advanced state-of-the-art leak detector capable of detecting many combustible, noncombustible and toxic gases. The following is a partial list of gases that the 720b is sensitive to: Acetone, Alcohol, Ammonia, Steam, Carbon Monoxide*, Butane, Gasoline, Jet Fuel, Hydrogen Sulfide, Smoke, Industrial Solvents, Methane, Lacquer Thinner, Naphtha, Propane, Natural Gas. *Not to be used to quantify the amount of CO present. Operating Instructions: 1. Turn the unit on in an uncontaminated environment (clean air away from the system in question) by moving the switch from the OFF position to the ON position. 2. The GREEN ready light will illuminate if there is ample battery power. The RED LED may flicker and the tick may sound during the warm-up. To silence the tick, rotate the thumb wheel fully counterclockwise. 3. Adjust the TICK ADJUST by rotating the thumb 0.561.8187

wheel in a clockwise direction until a uniform ticking sound is heard. The RED light will flash at the same time the tick sounds. 4. Approach suspected leak areas with the sensor until the tick begins to increase. When the tick increases, do not move the sensor from the area, rotate the TICK ADJUST slightly counterclockwise to slow the ticking and continue to approach the suspected leak area with the sensor. Continue to slow the tick until the location of the leak is found. If the tick stops, the concentration level has decreased. Move back in the opposite direction to find the leak again. 5. If the GREEN LED changes to orange color, change the batteries. 6. An earphone can be plugged into the earphone jack when using the instrument in noisy environments. 9. If the instrument does not perform or it has been damaged, follow the Operation Check section of this manual. Battery Replacement 1. Remove the battery compartment cover from the bottom of the handle by sliding the door away from the front side of the instrument. 2. Remove the batteries and replace by sliding the

negative (-) end of the batteries in first. 3. Replace the battery cover by sliding the door into the slots provided in the handle and allow it to snap into place. 4. For best performance use quality alkaline batteries. Operation Check To verify the operation of the 720b simply turn the unit on and allow it to warm up for approximately 1 minute. Expose the sensor to a known gas source such as an unlit butane lighter. The tick should increase when the gas in applied. The tick will decrease when the gas is removed. If the unit fails to respond, the sensor may need replacing or the unit may need to be sent in for repair: CAUTION: This unit must be sent to a factory authorized repair center for all repairs. Sensor Replacement 1. Turn the 720b off. 2. Pull off the sensor cap. 3. Unplug the old sensor and discard. 4. Replace sensor and sensor cap. 5. Turn on unit and perform Operation Check Warranty and repair/exchange policy 0.561.8187

Your TPI 720b is warranted to be free from defects in materials and workmanship for a period of one year after purchase (excluding sensor, calibration and batteries). If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at our option. This warranty covers normal use and does not cover damage which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. A purchase receipt or other proof of original date of purchase will be required before warranty performance will be rendered. Instruments out of warranty will be repaired for a service charge. Return the unit postpaid and insured to: Test Products International, Inc. 9615 SW Allen Blvd. Beaverton OR 97005 (503) 520 9197 This warranty gives you specific legal rights and you may also have other right which vary from state to state.

The Value Leader TM www.tpi-thevalueleader.com 750a Instruction Manual Copyright 2001, Test Products International, Inc