This document outlines: 1 Update Instructions 2 Appliance Firmware Version Information 3 Features and Enhancements 4 Known Issues / Restrictions 5 Service Processor Support Universal Management Gateway 2000 Appliance Release Notes Version 1.0.3.5 March 5, 2012 1 Update Instructions Please refer to your installer/user guide for detailed instructions on updating the Universal Management Gateway 2000 appliance. In order to have features listed in this release available through DSView 4 management software, DSView 4 software version 4.0.0.76 or later and the Universal Management Gateway appliance plug-in version 1.0.3.5 are required. Support for Trellis management software is not included in this version and will be provided in a future update. 2 Appliance Firmware Version Information Product Universal Management Gateway 2000 appliance Version 1.0.3.5
Appliance 3 Features and Enhancements Firmware Version 1.0.3.5 is an update to the initial release of the Universal Management Gateway 2000 appliance software. Please refer to your installer/user guide for a detailed list of features supported by the Universal Management Gateway appliance. Issue Description 7415 Inconsistent display of Status in the DSView software and the web user interface 8108 With LDAP pointing at root AD server, unable to login into Universal Management Gateway appliance as a user on child AD server 8133 Access Rights are not implemented 8184 authentication leveraging DSView software credentials is not supported 8192 s rights are not applied for Outlets and Power Distribution Unit (PDU) targets 8275 Service Processor (SP) Session: Sessions Table does not display any session information 8294 Groups do not appear in the Access List for Users & User Groups 8557 There is an occasional user interface (UI) hang- up with an endless spinning cursor at the VGA console. 8558 PDU- level operations should not be presented for metered- only PDUs 8562 Factory Default caused Service Processor service issue 8612 Cannot Create User After Web UI Firmware Upgrade 8694 SP M1000E Sensor information not updated after Refresh button is selected 8728 Monitor authentication services and restart if stopped 8790 IBM Blade Center Module SEL, Alert and Sensor info not displayed
4 Known Issues / Restrictions This release contains the following known issues. 1. Only temperature sensors connected to Power Distribution Units (PDUs) are supported. Other sensor types such as Dry-Contact, airflow and humidity are not supported. 2. VGA Console: a. The VGA console does not support the Universal Management Gateway appliance firmware upgrade feature. You can, however, use the firmware upgrade feature via the Universal Management Gateway Command Line Interface (CLI) console by logging in as an admin user and selecting Update Firmware from the menu. 3. DirectCommand: a. Service Processor (SP) browser session functionality is achieved through TCP port forwarding to client systems through an SSH tunnel. Web interfaces of some SPs may behave abnormally through the DirectCommand framework due to the client interacting with non-native SP ports and IP addresses. b. If the same client PC is used to simultaneously launch DirectCommand from the Universal Management Gateway web UI and the DSView 4 software, there will be a conflict between the two DirectCommand applets for the two sessions. This will cause an error message to be displayed when the DirectCommand session is started. To avoid this issue, always exit the DirectCommand applet when switching between the Universal Management Gateway web UI and the DSView software. c. AutoLogin fails on Internet Explorer 9 and Firefox 10. d. AutoLogin may fail to login to blades discovered through a chassis such as HP BladeSystem. 4. The Clear Log operation will clear the logs and prevent future data collection and is not suggested for use at this time. Issue Area Description Work- Around 2932 Service Processor Excessive time to load the system page None. May be seen with large numbers of SP s (70+) 4011 Architecture Still able to access the serial port even when it's already been disabled 5016 Architecture Get Selected button displayed in Access tab in User Groups page Access permissions can be used to restrict access 7070 Service Processor SPM text boxes on the UI need to be bigger and consistent 7164 Web UI Logging as admin/admin found that Administration field is lost after the Universal Management Gateway appliance is rebooted This issue is seen when logging into the web UI immediately after booting the appliance. Work- around is to log out and back in again.
7277 PDU PDU informational requests timing out 7480 Service Processor M610 DirectCommand AutoLogin launched from web UI very slow 7912 Web UI The Landing page shows SP Status as 'Idle' even if the server is Off. 7958 Other We should manually create snmptrapd_mss.conf on appliance in order to receive SNMP traps for engine; it is not convenient for users. 8009 CLI Add Emergency Password Unlock entry into Universal Management Gateway appliance local console 8038 Serial s Serial Access Rights - Session Access, Kill Multi Session, Multi Session Notification should not be configurable. Server power status can be viewed from the System Tab after selecting a in the pane. None. This feature is not fully supported at present. 8065 Service Processor The default name of new detected SP is different with the IP of the SP. 8250 Local port UI Factory Defaults - Retaining Specified Range of Network SPs Settings must be manually reset 8296 Service Processor On Administration Discovery page, clicking Search range start or Search range stop will cause UI to hang This issue occurs if a discovery range is not selected when the Start / Stop button is selected. Work- around is to select a discovery range first then select the button. 8424 User Authentication Administrator can change the Role of appliance- admin and of power- user groups It's possible to lose Admin access if the role of the Appliance- Admin group is set to something other than Admin. 8479 User Authentication Couldn't get SID from pamh This error may be seen when logging in when the appliance is still starting up. Work- around is to retry. 8513 Local port UI Service Processor Calling Function Errors Error messages may be displayed when viewing SP Alerts if the SP is busy or does not support Alert
configuration 8573 User Authentication LDAP authentication server given as domain name instead of IP address then the functionality is found to be broken Numeric IP address should be supplied 8629 Service Processor Web UI & DSView software DirectCommand AutoLogin fails on Internet Explorer 8 running on Win7/Win2008 (64- bit O/S) 8666 Local port UI Authentication - Adding DSVIEW Server does not work 8729 CLI Emergency Password Unlock Does not work on putty 8792 Web UI DirectCommand Session failure for IPMI 2.0 8812 Local port UI When time zone setting is changed, the screen size on the local UI changes 8825 Web UI Unable to launch Sol, Telnet and SSH session for IPMI 2.0 8839 PDU Admin- Power Distribution screen crashes Adobe Flash Player 8841 Platform Firmware upload should not allow downgrade DSView software Authentication requires that the appliance be enrolled from the DSView software. It's not currently possible to push the enrollment up from the appliance via the web UI. Use the serial console via Alt+F2 on the VGA Console "Downgrade" should be performed by selecting a previous firmware image on startup 8877 Service Processor Directcommand_Only SP cannot be added thru web UI or DSView software 8915 Authentication s and Groups listed in the Access page do not match the currently defined s and Group This issue occurs once the Access page is first displayed when editing either a User or User Group. Changing the user permissions of a new or Group subsequently requires the appliance to be rebooted.
5 Service Processor Support Tested Service Processors SP Firmware Version Cisco UCS 1.3(2d) Dell 10G idrac 1.53 (Build 3) Dell DRAC 4 1.75 (Build 06.03) Dell DRAC 5 1.20 (07.03.02) Dell DRAC/MC 1.4 Dell 10G idrac 1.53 (Build 3) Dell idrac M600 1. 50 (Build 13) Dell idrac M605 1.52 (Build 2) Dell idrac M610 2.2 (Build 33) Dell idrac M710 2.10 (Build 33) Dell idrac M805 1.52 (Build 2) Dell idrac6 R210 1.30 (Build 24) Dell idrac6 R410 1.13.01 Dell M1000E Chassis 2.11 FSC irmc 2.20G FSC irmc S2 3.95A (Base: V1.01A52) 3.44A HP BladeSystem OA: 3.00 Mar 19 2010 HP ilo 1.91 Device: 1.81 Jan 15 2010 HP ilo 2 1.22 1.77 1.81
HP ILO3 1.26 IBM BladeCenter AMM Firmware 54 IBM x3550 M2 (IMM) IBM x3650 M2 (IMM) IPMI 1.5 IPMI 2.0 SUN ALOM YUOO73M YUOO73M N/A N/A Unknown SUN ELOM 3.2 SUN ILOM 2.0.2.6 Dell DRAC3, DRAC4 and DRAC5 1. If a Java Applet in the web browser running on a Linux client does not have privileges to listen on port 443 of the local IP address (127.*.*.*), the DRAC3 DirectCommand functions will not be functional. Please ensure that the listen privilege is available for port 443. 2. When the maximum number of sessions in DRAC4 or DRAC5 has been reached, a new AutoLogin or vkvm DirectCommand session will fail. The failure can be recovered by resetting the SP via Telnet or SSH. The command for SP reset is: racadm racreset. 3. If DirectCommand launches for DRAC5 servers are unsuccessful, ensure that the JRE is set to allow temporary file storage and that previous temporary files are deleted through the Java Control Panel. 4. The DRAC5 does not support use of the forward slash in login passwords. Avoid use of the forward slash in the password definition. Dell DRAC/MC Chassis and Blades 1. The vkvm/vm operations for the DRAC/MC blades initiated through a DirectCommand browser session will function properly only if the client can directly communicate with the native SP web interface. 2. Sometimes, the AutoLogin DirectCommand operation to DRAC-MC servers does not complete and either displays the Internet Explorer cannot display the webpage message for the Internet Explorer 7 browser, or displays a blank page for the Firefox 3 browser. The AutoLogin DirectCommand operation has been observed to complete if the page is refreshed. 3. FRU information is not available for the Drac MC. Dell M1000e CMC 1. The M1000e native web interface cannot be opened using the Firefox 3 browser, which also affects the browser link within the Universal Management Gateway appliance when using the Firefox 3 browser. Instead, the AutoLogin DirectCommand option can be used or Internet Explorer 7 can be used as the browser. 2. M1000e AutoLogin DirectCommand sessions are not automatically restarted upon session timeout. Click the AutoLogin DirectCommand link again to restart the session. 3. The M1000e "Single Sign-in" functionality cannot be supported when logged in using the Browser DirectCommand login. Use the AutoLogin DirectCommand for this functionality. 4. When connecting to an idrac blade using the M1000e "Single Sign-in" feature, the blade s vkvm connection is only functional if the default vkvm ports are configured in the blade. If the vkvm ports are redefined, then vkvm is only supported through a DirectCommand session to the blade.
5. The idrac blade can be accessed using the M1000e "Single Sign-in" feature when the blade is selected from the M1000e server status page that shows links to all blades, and not from a link on an individual blade status page. 6. Occasionally, connections to an idrac blade using the M1000e "Single Sign-in" feature or to an idrac blade managed within the M1000e chassis will not complete. Clear the browser cache and re-launch the session if this situation occurs. 7. The CMC web interface login selection within the idrac blade web interface is not accessible through the Universal Management Gateway appliance. Instead, the M1000e AutoLogin DirectCommand option should be used to access the CMC web interface. 8. The login process for the M1000e may take up to 20 seconds after proper username and credentials are presented and therefore it may take several seconds to access some features in the Universal Management Gateway appliance web interface (e.g., displaying power information may take 15-20 seconds for an M1000e chassis). 9. The Dell M1000e CMC chassis requires that all servers within the chassis must first be turned off successfully before the chassis can be turned off. Please follow this sequence when controlling the CMC power through the Universal Management Gateway appliance to avoid inconsistent behavior in power states and/or error messages. Dell idrac Blades 1. Occasionally, AutoLogin DirectCommand attempts to connect to an idrac blade are rejected, and a DirectCommand Applet Error is presented that contains an error string from the blade, such as Failure_Session_Creation. Workarounds include retrying the AutoLogin DirectCommand operation after a few minutes, retrying blade login through the chassis Single Sign-in feature, or resetting the blade. 2. Sometimes after a session expires, the idrac blade logout selection is not processed. If this occurs, close the browser window or tab. 3. The login session associated with an idrac blade vkvm session is not automatically terminated and must be allowed to time out. 4. Some anomalies have been seen with the Dell M610 and M710 blades when it is either directly managed or managed through the Universal Management Gateway appliance. These anomalies include: a. The default root/calvin uid/password does not always allow access, yet another user-defined username does seem to work (M610 only). b. Virtual Media does not connect (M610 only) c. Virtual Media disconnect when launched under the Internet Explorer browser causes vkvm abort. (M610 and M710). d. Single Sign-on through the M1000e chassis to the blade fails to complete. (M610 only). Please check the Dell web site for release note updates. Dell idrac6 Monolithics and Blades 1. Errors may occur when attempting to add a Dell idrac to a Universal Management Gateway appliance if the SP is already managed by another Universal Management Gateway appliance. Fujitsu Technology Solutions (FTS) irmc S2 1. If AutoLogin DirectCommand operations for irmc2 servers present an additional login prompt or are otherwise unsuccessful, ensure that the JRE is set to disallow temporary file storage and that previous temporary files are deleted through the Java Control Panel. 2. irmc S2 SPs that use login passwords containing the ampersand character cannot be discovered or managed by the Universal Management Gateway appliance. The SP can be discovered and managed when the login passwords do not contain the ampersand character. 3. The Remote Storage applet provided by irmc2 servers is only accessible through the Universal Management Gateway appliance using the Native IP feature. If there are problems connecting to the Remote Storage applet, a tech note is available upon request.
HP ilo, ilo2 1. The ilo2 vkvm runs with ActiveX in an Internet Explorer browser and with a Java applet in other browsers such as Firefox 3. The vkvm with ActiveX integrates Virtual Media, while vkvm with a Java applet does not. Multi-session operation is not supported for vkvm DirectCommand operations in the Internet Explorer browser. 2. The ilo 2 does not support use of the single or double quotation marks in login passwords. Avoid use of quotation marks in password definition. HP BladeSystem and blades 1. The HP Integrity blade product line is not supported as these blades use a different management interface than the Proliant blades 2. The vkvm/vm operations for the HP blades initiated through a DirectCommand browser or AutoLogin session will function properly only if the client can directly communicate with the native SP web interface. 3. In limited testing with the HP BladeSystem OA version 1.81, it was noted that blade power, sensor and SoL operations are not functional when the blade is managed through the OA. These operations are functional when the ilo blade is discovered and managed separately from the BladeSystem. 4. The HP BladeSystem "Single Sign-in" functionality cannot be supported when logged in using the Browser DirectCommand login. Use AutoLogin DirectCommand for this functionality. IBM RSA-II 1. When a vkvm session is connected on an RSA-II server, a second login with the same userid will cause the original vkvm session to be disconnected. This includes a second login through the Universal Management Gateway appliance which will use the same userid. This behavior is by design in the RSA-II servers. 2. Intermittent load failures of the vkvm and VM applets on RSA-II servers are seen when the JRE is allowed to keep temporary files on the computer. When using these vkvm and VM applications on RSA-II servers, Avocent recommends setting the JRE to disallow temporary file storage through the Java Control Panel. 3. vkvm operation to RSA-II servers launched through a DirectCommand browser login session may not be successful. Avocent recommends using the DirectCommand AutoLogin operation. 4. vkvm operation to RSA-II servers is incompatible with JRE-6u13. Avocent recommends using JRE-6u11 or JRE-6u14 or later for these applications. 5. When managing RSA-II servers through a Universal Management Gateway appliance using the DSView 3 software, DirectCommand sessions sometimes cannot be successfully launched when using JRE versions above 6u7 without disabling the next-generation Java Plug-in setting through the Java Control Panel. If these issues continue to occur while disabling the next-generation Java Plug-in, Avocent recommends downgrading the JRE to 6u7. 6. The native web interface for the IBM 3950 RSA-II server will not allow login if the password contains special characters unless the SP firmware is upgraded to A3EP40A or later. Please upgrade the SP firmware to use special characters passwords with DirectCommand functionality. IBM BladeCenter and Blades 1. The IBM BladeCenter native web interface provides access to vkvm and vmedia functions for its blades. DirectCommand operations for blades should be initiated through the BladeCenter interface. 2. AutoLogin and vkvm DirectCommand operations for the IBM BladeCenter fail by presenting a login prompt when the BladeCenter is automatically discovered and/or managed. To establish AutoLogin DirectCommand functionality, please delete the BladeCenter from the Universal Management Gateway appliance web interface and then manually add it back into the appliance. IBM IMM Monolithics 1. The vkvm DirectCommand sessions for IMM-based monolithic servers do not successfully launch on some IE7 and IE8 installations. To correct this issue from the IE browser menu, select Tools, then Internet Options, then select the Security tab and click the Custom Level button. Scroll down to the Downloads settings group and click the Enable radio button for the Automatic prompting for file downloads setting.
2. IMM-based monolithic servers purchased with the IMM Standard option do not support vkvm. The Universal Management Gateway appliance cannot detect the IMM Standard configuration prior to web interface login, so the user is not notified until after the vkvm login attempt. 3. Occasionally, AutoLogin and vkvm DirectCommand sessions for IMM-based monolithic servers do not successfully launch when switching the session launch between the DSView 3 software and the Universal Management Gateway appliance web interface. Clear the browser cache and re-launch the session if this situation occurs. 4. The IMM Monolithic servers do not support use of the special characters ':', '&', '\' and '<' in login passwords. Avoid use of these characters in the password definition. 5. If you use the Universal Management Gateway appliance discovery feature to manage any type of IBM IMM server, the IMM needs to be configured so that its 'lockout period 5 login failures' is 1 minute. On the IMM Web UI, this is under System -IMM Control-Login Profiles- Global Login Settings. IPMI 1.5 / IPMI 2.0 1. IPMI 1.5 or IPMI 2.0 servers have no native management web interface by default, but these servers can be integrated with a web interface. In this case, a user-defined SP profile can be created for the IPMI SP with the appropriate web port and web scheme to enable the DirectCommand Browser session option in the Universal Management Gateway appliance web interface. Sun ALOM, ELOM, ILOM 1. ILOM servers must have their http service running to be properly discovered using the autodiscovery mechanism. If the http server is not running, the server can still be manually added. 2. ALOM servers have no native management web interface by default, but these servers can be integrated with a web interface. In this case, a user-defined SP profile can be created for the ALOM SP with the appropriate web port and web scheme to enable the DirectCommand Browser session option in the Universal Management Gateway appliance web interface. 3. The ELOM native web interface vkvm operation may conflict with other network services commonly run on server machines. If conflicts occur, we suggest performing these operations on a workstation computer instead of a server computer. 4. The ILOM KVM/VM applet requires the username and password to be entered manually. 5. ELOM and ALOM SPs that use login passwords containing special characters cannot be discovered or managed by the Universal Management Gateway appliance. These SPs can be discovered and managed when the login passwords do not contain special characters. Emerson and Emerson Network Power are trademarks or registered trademarks of Emerson Electric Co. Avocent, DSView and Trellis are trademarks or registered trademarks of Avocent Corporation. Internet Explorer is a registered trademark of Microsoft Corporation. Firefox is a registered trademark of The Mozilla Foundation. HP is a trademark of Hewlett-Packard Development Company, L.P., Dell is a registered trademark of Dell Corporation. All other marks are the property of their respective owners. This document may contain confidential and/or proprietary information of Avocent Corporation, and its receipt or possession does not convey any right to reproduce, disclose its contents, or to manufacture or sell anything that it may describe. Reproduction, disclosure, or use without specific authorization from Avocent Corporation is strictly prohibited. 2012 Avocent Corporation. All rights reserved.