Anytime, Anywhere. Remote Maintenance. http://www.mitsubishielectric.co.jp/english/



Similar documents
New Product Release. Web Server Module. An advanced Web server module with powerful remote maintenance tools. Mitsubishi PLC QJ71WS96

MITSUBISHI. New! Excel Communication Support Tool MX Sheet Version No.191E NEW PRODUCT RELEASE. Mitsubishi Integrated FA Software

FINS Gateway For OMRON PLCs

Contents Overview of RD Web Access What is RD Web Access?... 2 What are the benefits of RD Web Access versus thin client?...

The Next Generation in Industrial Programming Mitsubishi FA Integrated Concept

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

M2M/IoT Solutions.

Servo System Network SSCNETIII

Use of wireless LAN makes FA network system comfortable!

S7 for Windows S7-300/400

Open Field Network CC-Link Troubleshooting Guide

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

Contents. 1 VPN Remote Access Service

Wireless Router Setup Manual

How to read this guide

Setting/Monitoring Tools for the C Controller Module Version 4 Operating Manual -SW4PVC-CCPU-E

MDM Mass Configuration Tool User s Manual

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Custom Solutions Center. Users Guide. Low Cost OEM PackML Templates L02 Release. Version LC-1.0

Machine control going www - Opportunities and risks when connecting a control system to the Internet

DSL-2600U. User Manual V 1.0

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Broadband Router ESG-103. User s Guide

Item. Model name. Max. controllable groups. On / Off. Test operation. Group setting. RC prohibition. Failure. Defrosting. Current time.

Mitsubishi Integrated FA Software

The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example. Select [Project] [New].

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Use templates to revolutionize your screen design style

TENVIS Technology Co., Ltd. User Manual. For H.264 Cameras. Version 2.0.0

MN-700 Base Station Configuration Guide

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Think Automation and beyond... IDEC WindSRV. KEPServerEX OPC Server

PN5212/PN5320/PN7212/PN7320

Aeroqual Connect and Cloud

PowerCommand 500/550 Remote Monitoring System

AXIS 262+ Network Video Recorder

4-CH Hybrid Digital Video Recorder

ABB solar inverters. User s manual ABB Remote monitoring portal

Turbo 85 Mbps Powerline Ethernet Adapter Model # APL8512. User s Manual. Ver. 1A

Controller & Service Software

Addonics T E C H N O L O G I E S. NAS Adapter. Model: NASU Key Features

Permissible ambient temperature Operation Storage, transport

ADSL MODEM. User Manual V1.0

C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

SNMP Web Management. User s Manual For SNMP Web Card/Box

TP-LINK TD-W8901G. Wireless Modem Router. Advanced Troubleshooting Guide

Chapter 15: Advanced Networks

ABB solar inverters. User s manual ABB Remote monitoring portal

Industrial Training Schedule Spring 2012

2 Setting Up the Hardware for a Wired Ethernet Network Setting Up the Software for an Ethernet Network... 21

AC750 Multi-Function Concurrent Dual-Band Wi-Fi Router

Automation software Concept V2.6 The flexible IEC development environment to optimize PLC performance

Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)

GV-Data Capture V3 Series User's Manual

3.5 EXTERNAL NETWORK HDD. User s Manual

Internet Access to a DVR365

QUICK START GUIDE. Cisco S170 Web Security Appliance. Web Security Appliance

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)

Release Notes: PowerChute plus for Windows 95 and Windows 98

SAFETY PRECAUTIONS (Read these precautions before using this product.)

Getting started. Creating a Web Server support application

Chapter 2 Preparing Your Network

Temperature & Humidity SMS Alert Controller

Broadband ADSL2+ Modem DM111PSPv2

RFID Logger Software User Manual Rev 1.0

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

SAFETY PRECAUTION. (Always read these instructions before using the products.)

7.7 Ethernet Communication (AFPX-COM5)

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

SNC-VL10P Video Network Camera

P-660HWP-Dx. Quick Start Guide g HomePlug AV ADSL2+ Gateway. Version /2007 Edition 1. Copyright All rights reserved.

Chapter 2 Introduction

How To Set Up An Andsl Modem Router For Internet Access

SOFTWARE SETUP MANUAL. GX Developer-FX

DIGICLIENT 8.0 Remote Agent Software

How To Check If Your Router Is Working Properly

PRODUCT INFORMATION. SICK Remote Service Product and System Support. Secure remote monitoring for efficient service

Smart Telephone System

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

AXIS 211A Network Camera

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

Cisco S380 and Cisco S680 Web Security Appliance

TMA Management Suite. For EAD and TDM products. ABOUT OneAccess. Value-Adding Software Licenses TMA

PE6108/PE6208/PE8108/PE8208

Please use only wired network connections to configure the Router.

Chapter 6 Using Network Monitoring Tools

Broadband Router ALL1294B

Transcription:

Mitsubishi Electric Cpation Nagoya Wks is a facty certified f ISO14001 (standards f environmental management systems) and ISO9001 (standards f quality assurance management systems) http://www.mitsubishielectric.co.jp/english/

MELSEC Compatible Tool Easily handle a range of tasks, from err notification to program debugging and updating, remotely! Guide to MELSEC remote maintenance tools accding to connection. Connection method compatibility list 1 : 1 P.3~4 Configuration administrat Connect to internet away from the office. Warning MELSEC configuration Connection style Client configuration 1A Web server (GX RemoteService-I) MELSEC PLC PC CPU Module (GX RemoteService-I) Modem Personal computer (GX RemoteService-I) Modem personal computer (GX Expler) 1B MELSEC PLC Web server Modem Modem Personal computer (Web browser) Err notification The program cannot be crected with GX Expler. Functions connection environment Perfect f service staff who are always on the move!! Get infmation anywhere, anytime! monit Ladder monit monit debug Ladder monit 1A 1B Phone Line 2 Application examples administrat 1A: Advanced diagnostics and preventive maintenance, such as ladder moniting via the internet. 1B: Diagnostics and preventive maintenance from a remote location using only simple settings without needing a server PC. Facty Flo Connect from office over a public phone line. 2 : Phone Line P.5 monit Ladder monit Configuration MELSEC configuration Connection style 2 MELSEC PLC modem interface Modem debug MELSEC PLC 3 administrat Connect from office over intranet (in-house LAN). Modem personal computer (GX Developer) Functions Ideal f machine makers requiring continuous maintenance and servicing. s can be monited over a public phone line. (LAN) Client configuration monit Ladder monit debug 2 monit Ladder monit Application examples 2: Remote moniting, diagnostics and maintenance using GX Developer where the MELSEC PLC CPU and client device cannot be connected by LAN. debug 3 : (LAN) P.6 Configuration Maintenance Ethernet interface Remote maintenance MELSEC configuration Connection style 3 MELSEC PLC Ethernet interface (LAN) Ethernet board Personal computer GX Developer GX Expler Functions Perfect f maintenance personnel at the facty!! Use a LAN connection to monit devices with a desktop PC. Client configuration 3 monit Ladder monit debug *2 *2 The program cannot be edited with GX Expler. Application examples 3: Remote moniting, diagnostics and maintenance using GX Developer and GX Expler over an existing LAN connection. 1 2

MELSEC Compatible Tool 1A This Connect to internet away from the office. connection allows e-mailing, device moniting, device testing, ladder moniting, and program uploading/downloading. 1B Connect to internet away from the office. This connection allows e-mailing, device moniting, device testing and logging. Advanced diagnostics and preventive maintenance, such as ladder moniting, over the internet. Enables remote moniting, diagnostics and preventive maintenance via the internet with simple settings. A server PC does not need to be installed. monit test Ladder monit upload /download monit test The high-function MELSOFT products realize complete maintenance. Easily access over the internet using a Web server. administrat Facty Flo Present/away from the office connection environment Mobile [Laptop personal computer, etc.] GX Expler Version2 Equipment Err notification Warning Maintenance monit Ladder monit upload/ download MELSEC PLC Q, QnA, and A Series connection environment xdsl/ethernet Web server PC CPU Module, *2 Personal computer *3 GX RemoteService-I Version2 LAN connection and analog modem are also suppted. *2 The PC CPU can be used with the Q series. *3 Web server software (supplied from Microsoft) is required. Personal Web Server 0 (PWS): Windows 98/NT0 Infmation Services (IIS0): Windows 2000 *3 administrat Present/away from the office connection environment Mobile [Laptop personal computer, etc.] Web browser Err notification Warning Maintenance monit Facty Flo MELSEC PLC Q Series connection environment xdsl/ethernet Web server LAN connection and analog modem are also suppted. Access method administrat Q Series QJ71WS96 / Personal computer GX Expler Version2 MELSEC PLC Web server GX RemoteService-I Version2 Modem Modem xdsl modem Broadband router Points f selecting facty side connectiondevices A new system can be configured with the Q series by using web server s and PC CPUs. This system is perfect when a PC cannot be installed due to the industrial environment. Equipment Access method administrat / Personal computer Facty MELSEC PLC PC CPU GX RemoteService-I Version2 Modem Q Series MELSEC PLC Personal Computer GX RemoteService-I Version2 Modem Q, QnA, and A Series Web server software PWS IIS Web server software PWS IIS When using the QnA A series, when adding to an existing configuration, the system can be easily configured by installing a PC. Facty Q Series QJ71WS96 MELSEC PLC Web server Modem Modem xdsl modem Broadband router 3 4

MELSEC Compatible Tool 2 Connect from office over a public phone line. This connection allows device moniting, device testing, ladder moniting, program uploading/downloading, and program crections. 3 Connect from office over an. This connection allows e-mailing, device moniting, device testing, ladder moniting, program uploading/downloading, and program debug. Ideal f machine makers requiring continuous maintenance and servicing. Protect delivered facilities using a public phone line. Realize remote maintenance over an, enabling easy and efficient maintenance. monit test Ladder monit upload /download debug monit test Ladder monit upload /download debug The program cannot be edited with GX Expler Access the facty via a public phone line using a modem interface. Access LAN using Ethernet interface. administrat From office Facty Flo administrat At the office Err Notification Facty Flo connection environment Mobile [Laptop personal computer, etc.] GX Developer Public phone line Maintenance monit Ladder monit debug MELSEC PLC Q, QnA, A, and FX series connection environment Modem interface LAN connection environment Personal computer GX Developer GX Expler Warning Router LAN extension over routers possible Router Maintenance monit Ladder monit debug MELSEC PLC Q Series LAN connection environment Ethernet interface Equipment Access method Equipment administrat Personal computer GX Developer Modem Access method Facty MELSEC PLC Modem interface Q, QnA, A, and FX Series F MELSEC-Q: QJ71C24N (-R2) External modem (Possible with GX Developer Ver.4 and higher) F MELSEC-A/QnA: Q6TEL External modem (Possible with GX Developer Ver.3 and higher) F MELSEC-FX: RS-232 interface External modem (Possible with GX Developer Ver.3. and higher) administrat Facty Personal computer GX Developer GX Expler Ethernet interface MELSEC PLC Ethernet interface Q Series QJ71E71-100 QJ71E71-B5 QJ71E71-B2 5 6

MELSEC Compatible Tool TOOLS Compatible tools Mitsubishi Integrated FA Software GX Expler Version2 Easy to use maintenance functions Improved maintenance capability with this version upgrade 1. 3. View netwk status easily With GX Expler, the netwk number, station number, and project data content is presented in an easy to view graphic fmat. Therefe, program maintenance can be done efficiently, without having to reconfigure the netwk. The system configuration can be confirmed easily by using GX Expler, without needing pri knowledge of the netwk configuration. Also, project data can be uploaded and confirmed from a remote location, without having to be present on the shop flo. 2. Easy program With its smart drag & drop features, even first-time users can upload, download, edit programs easily when using GX Expler. Editing the programs is done simply just by double clicking on the selected program comment icons, which automatically starts the MELSEC PLC programming tool GX Developer. Also, the project data sted on the desktop PC is uploaded automatically, just by double clicking on the selected program. PLC and netwk diagnostics via the netwk Diagnostics can be perfmed just by selecting and right clicking on the station. Diagnostic targets: PLC, MELSECNET/H, netwk, CC-Link, and system monit Extensive maintenance functions Conventional diagnostic and monit functions have been increased extensively, providing an optimum maintenance tool. Connection specifications and access device settings distinguished by using logical names Monit CPUs in a multi CPU system simultaneously via device monits Fault diagnostics f user-defined fault help and troubleshooting displays Improved maintenance using timing chart and ladder monit Enhanced fault diagnostics using detailed sampling and analysis functions Improved project management tools Expanded features ranging from project search to referencing. Utilize project management features between PC and PLC and between PCs (FTP transmission). Mask selected data during a project search Compatibility with user documentation system Consistent result checking via ladder displays Suppt online program change (PLC download) Direct CPU connection Remote access is suppted. Remote access to GX Expler through, in addition to direct CPU connection. *GX RemoteService-I Ver.2 must be installed Web server QJ71WS96 mounted on QCPU system. 8. 9. Useful functions Focus on maintenance using user-friendly functions. Return customized settings to defaults. Display guidance via help tool tips. Compatibility with intelligent mouse and scroll button Operation log Easy-to-use menu Customized screens Security settings Extensive range of suppted CPUs These functions are available from Version2. Screen cols, menu configurations, tool bars, and hot-key settings are user-customizable. The user settings can be saved, and activated as "My Tools" f each individual user. User A Function use and access device connection and selection are set f each user setting. Set data is passwd-protected. 10. User B User-customized User C All CPU series and s suppted by Web connection, MELSOFT connection, GX Developer, and GX Expler Ver.2 are suppted. GX Expler Version2 User D List multiple data Mitsubishi Integrated FA Software GX RemoteService-I Direct CPU connection Expanded project control further improves maintenance efficiency. Maintenance using ladder monit Maintenance using timing charts New MELSOFT connection makes remote diagnostics easy. monit simultaneously moniting multiple CPUs Maintenance using GX Expler Ver.2 practical maintenance functions 7 is possible locally and remotely. 8 Version2 Execute GX Expler maintenance functions over the an intranet using GX Expler and GX RemoteService-I. 1. Automatic e-mail when a system fault occurs When a system err occurs, the system status is automatically notified by e-mail. Therefe, when a system fault occurs, the appropriate personnel can be notified immediately via e-mail, reducing the time taken f diagnostics of the problem and recovery. 2. diagnostics via cellular phone. Diagnostics can be perfmed from a remote location by using the cellular phone's mobility. Therefe maintenance service personnel do not need to be on-site to rectify the problem, once a system err has been notified. 3. Easy setup without program The system is set up without complicated programming via the setup Wizard, just by answering simple systemquestions on screen. Web functions moniting and testing can be done using the Web server installed with GX RemoteService-I Ver.2. This is done by accessing the cresponding URL from the client web browser cellular phone. The cresponding URL suppts automatic sending of e-mail by setting the automatic trigger conditions in the Web server, sent manually. MELSOFT connection functions With GX RemoteService-I Ver.2 installed on a server, The PLC can be accessed remotely via / from a PC installed with MELSOFT software. *Maintenance functions are enhanced using Ver.2 with GX Expler Ver.2. Install GX RemoteService-I Ver.2 MELSOFT Increased suppted netwks In addition to connection, s are also suppted. Connection choices include analog modems, and xdsl, making it easy f users to configure optimum systems and incpate this software into an existing system. 8. Analog modem xdsl GX RemoteService-I Powerful security features Authentication using a user name and passwd is executed when connecting the client and server to prevent the server from being accessed illegally. Security has been upgraded f Web functions and MELSOFT connections. Setting enabling connection without a user name passwd is selectable f use over an intranet. 9. Extensive range of suppted operating environments. This software is compatible with the Web server, PC CPU, and conventional Windows PC. Therefe an ideal solution can be provided accding to the application. No further devices are needed when using the Web server PC CPU, as these products do not use I/O allocation points, no extra parameter setup is needed on the QCPU system. Choose the system accding to the application requirements. Web server PC CPU Windows PC Extensive range of suppted CPUs Web and MELSOFT connection access all CPU series and s suppted by GX Developer and GX Expler Ver.2. Individual functions are improved with version upgrades! Using both software's together, provides an extensive remote maintenance solution. Upload Download Web server PC CPU These functions are available from Version2. Windows PC Version2

MELSEC Compatible Tool TOOLS Compatible tools Mitsubishi Integrated FA Software GX Expler Version2 Easy to use maintenance functions Improved maintenance capability with this version upgrade 1. 3. View netwk status easily With GX Expler, the netwk number, station number, and project data content is presented in an easy to view graphic fmat. Therefe, program maintenance can be done efficiently, without having to reconfigure the netwk. The system configuration can be confirmed easily by using GX Expler, without needing pri knowledge of the netwk configuration. Also, project data can be uploaded and confirmed from a remote location, without having to be present on the shop flo. 2. Easy program With its smart drag & drop features, even first-time users can upload, download, edit programs easily when using GX Expler. Editing the programs is done simply just by double clicking on the selected program comment icons, which automatically starts the MELSEC PLC programming tool GX Developer. Also, the project data sted on the desktop PC is uploaded automatically, just by double clicking on the selected program. PLC and netwk diagnostics via the netwk Diagnostics can be perfmed just by selecting and right clicking on the station. Diagnostic targets: PLC, MELSECNET/H, netwk, CC-Link, and system monit Extensive maintenance functions Conventional diagnostic and monit functions have been increased extensively, providing an optimum maintenance tool. Connection specifications and access device settings distinguished by using logical names Monit CPUs in a multi CPU system simultaneously via device monits Fault diagnostics f user-defined fault help and troubleshooting displays Improved maintenance using timing chart and ladder monit Enhanced fault diagnostics using detailed sampling and analysis functions Improved project management tools Expanded features ranging from project search to referencing. Utilize project management features between PC and PLC and between PCs (FTP transmission). Mask selected data during a project search Compatibility with user documentation system Consistent result checking via ladder displays Suppt online program change (PLC download) Direct CPU connection Remote access is suppted. Remote access to GX Expler through, in addition to direct CPU connection. *GX RemoteService-I Ver.2 must be installed Web server QJ71WS96 mounted on QCPU system. 8. 9. Useful functions Focus on maintenance using user-friendly functions. Return customized settings to defaults. Display guidance via help tool tips. Compatibility with intelligent mouse and scroll button Operation log Easy-to-use menu Customized screens Security settings Extensive range of suppted CPUs These functions are available from Version2. Screen cols, menu configurations, tool bars, and hot-key settings are user-customizable. The user settings can be saved, and activated as "My Tools" f each individual user. User A Function use and access device connection and selection are set f each user setting. Set data is passwd-protected. 10. User B User-customized User C All CPU series and s suppted by Web connection, MELSOFT connection, GX Developer, and GX Expler Ver.2 are suppted. GX Expler Version2 User D List multiple data Mitsubishi Integrated FA Software GX RemoteService-I Direct CPU connection Expanded project control further improves maintenance efficiency. Maintenance using ladder monit Maintenance using timing charts New MELSOFT connection makes remote diagnostics easy. monit simultaneously moniting multiple CPUs Maintenance using GX Expler Ver.2 practical maintenance functions 7 is possible locally and remotely. 8 Version2 Execute GX Expler maintenance functions over the an intranet using GX Expler and GX RemoteService-I. 1. Automatic e-mail when a system fault occurs When a system err occurs, the system status is automatically notified by e-mail. Therefe, when a system fault occurs, the appropriate personnel can be notified immediately via e-mail, reducing the time taken f diagnostics of the problem and recovery. 2. diagnostics via cellular phone. Diagnostics can be perfmed from a remote location by using the cellular phone's mobility. Therefe maintenance service personnel do not need to be on-site to rectify the problem, once a system err has been notified. 3. Easy setup without program The system is set up without complicated programming via the setup Wizard, just by answering simple systemquestions on screen. Web functions moniting and testing can be done using the Web server installed with GX RemoteService-I Ver.2. This is done by accessing the cresponding URL from the client web browser cellular phone. The cresponding URL suppts automatic sending of e-mail by setting the automatic trigger conditions in the Web server, sent manually. MELSOFT connection functions With GX RemoteService-I Ver.2 installed on a server, The PLC can be accessed remotely via / from a PC installed with MELSOFT software. *Maintenance functions are enhanced using Ver.2 with GX Expler Ver.2. Install GX RemoteService-I Ver.2 MELSOFT Increased suppted netwks In addition to connection, s are also suppted. Connection choices include analog modems, and xdsl, making it easy f users to configure optimum systems and incpate this software into an existing system. 8. Analog modem xdsl GX RemoteService-I Powerful security features Authentication using a user name and passwd is executed when connecting the client and server to prevent the server from being accessed illegally. Security has been upgraded f Web functions and MELSOFT connections. Setting enabling connection without a user name passwd is selectable f use over an intranet. 9. Extensive range of suppted operating environments. This software is compatible with the Web server, PC CPU, and conventional Windows PC. Therefe an ideal solution can be provided accding to the application. No further devices are needed when using the Web server PC CPU, as these products do not use I/O allocation points, no extra parameter setup is needed on the QCPU system. Choose the system accding to the application requirements. Web server PC CPU Windows PC Extensive range of suppted CPUs Web and MELSOFT connection access all CPU series and s suppted by GX Developer and GX Expler Ver.2. Individual functions are improved with version upgrades! Using both software's together, provides an extensive remote maintenance solution. Upload Download Web server PC CPU These functions are available from Version2. Windows PC Version2

MELSEC Compatible Tool TOOLS Compatible tools MELSEC Q Series Web server QJ71WS96 Remote moniting, diagnostics, and preventive maintenance are realized. Therefe, no need to include a separate server PC. 1. 2. Collect and display tag data. A group of device data can be registered as a block using tag names, f each PLC CPU on the netwk. The web server samples this data in tag units. The collected data can be displayed on the web browser by specifying the tag name. Data logging functions (2) data is collected in blocks, depending on the tag settings. U P Tag data High-speed data logging at 100ms intervals is triggered by events. Useful f determining errs befe/after they occur. Setting file names f logging files Efficient file management by adding, file name and date/time stamp. Me improved functionality f logging monit Standard logging monit is far easier to use because of added functions. Web sever Tag setting Tag name 01: A process Web server Component name CPU name Pressure Concentration Water level Temperature Product Qty. CPU1 CPU1 CPU1 CPU1 CPU2 New function (3)Specifying the tag name, displays the block data. D100 D200 D300 D400 D10 (1) Tag name and tag components (devices and names), are set using the web browser. High-speed! 100ms interval New setting Tag name Process A Process B Process C data (1) setting in Web browser interval Set interval: 100ms Set interval: 60ms Fixed time: 05:00:00 U P (2)Relative to settings, web server logs tag data. Improved function External device (Client) Tag data monit (3) Log data is displayed by setting a logging name. External device (Client) monit User screen creation function Graphical User definition screen Web server includes applet parts such as level and graphic parts, and they gives graphical interface to user defined screens. Change states values using parts Turn bit data ON/OFF and change data values from customized web pages. User screen f personal computer Read/write file data to PLC CPU Event occurrence Download files to the PLC CPU Files, such as recipe data, are downloaded to the PLC CPU (Select the file fmat from binary CSV). Upload files from the PLC CPU Produce data in list fm, etc., in the PLC CPU (Select the file fmat from binary CSV). <Downloading files to PLC CPU> Download files to the PLC CPU <Uploading files from PLC CPU> Download Upload U P New notification Exceeding max temp. Create data with Excel, etc. Open data with Excel, etc. Customized web page Create separate web pages f each user. Increased functions f creating customized web pages Text only customized pages Create simple to use pages Enhanced security functions Basic authentication Web server can authenticate user accding to user name and passwd. An access log is also included. IP filter New Enhanced security features by incpating an IP filtering system, therefe only allowing access to permitted IP addresses. Therefe by combining this feature with HTTP Basic Authentication features, higher security is achievable as standard. 8. Checking details with a Mobile [Laptop personal computer, etc.] Various communication Type Compatible with internet connections using xdsl analog modem, allowing the user to select the connection style that matches the system. The LAN connection enables this system to beused in an internet environment. Universal Plug and Play compatibility New Easily connect to a broadband router using the Universal Plug and Play function. 3. Ladder program moniting New Event monit Remote moniting and diagnostics f ladder program. Functions include upload, download, edit of ladder program(s). *2 Upload GX RemoteService-I Ver.2 Download GX Expler Ver.2 GX Expler Ver.2 and GX RemoteService-I Ver.2 (coming soon) are required. *2 GX Developer is required f editing the ladder programs. 9 Ladder monit Web server Tag data U P * View logging data in list graph fmat. Increased functionality f event moniting The number of CPUs and tag data (devices) that can be monited simultaneously has been increased, therefe larger systems can be monited. Useful f determining errs befe/after they occur. CPU event monit: Up to 64 points Event histy monit Tag event monit: Up to 256 points Event triggered netwk connection Netwk connection/disconnection can be triggered by events. This method is ideal f applications where the netwk connection is charged cresponding to "online time". (2) CPU monit and data monit are setup from the web server event settings. Tag data monit Time interval monit CPU status monit Event setting Tag name Component name Condition Trigger value A process A process A process (3)Event histy is displayed on the event histy monit screen. Pressure Temperature Water level (1) Event settings are done using web browser. 120 30 200 data External device (Client) Tag data (4) If necessary, e-mail can be sent when an event occurs. Upload from PLC CPU Connection Configuration s Analog modem xdsl modem Broadband router service provider Web server interface Data communication control command DR Signal Control Web server interface Protocol Connection style Web server side interface NAT UPnP Protocol Authentication method IP address (When being set) Available f Web server CH2 (RS232) interface. Suppting Hayes compatible AT commands. Independently turn on DR (DSR) signal. Available f Web server CH1 (10BASE-T/100BASE-TX) interface. PPPoE (PPP over Ethernet) PPPoA (PPP over ATM) Bridge router (having same functions as broadband router) Available f Web server CH1 (10BASE-T/100BASE-TX) interface. Must have NAT (address conversion) function Must be compatible with Universal Plug and Play (UPnP)*2 PPP (Point to Point Protocol) PAP CHAP (Operable without authentication) Global IP address must be assigned. *2 SMTP server must be prepared.. Refer to item (1) of the perfmance specifications f details on the Web server CH1/CH2 transmission speed. *2. If the product is incompatible with UPnP, a fixed IP address contract must be bound with the internet service provider, and the router NAT settings must be made by the user. Perfmance specifications Type Compact FlashTM card Interface Data transmission speed 10BASE-T/ Transmission method 100BASE-TX Maximum number of cascade connection Maximum segment length *2 RS-232 Suppted function Interface method Synchronization method Transmission speed Transmission distance Data fmat Parity check Start bit Data bit Stop bit Transmission control Recommended cable External wiring connect Supplied power voltage Size Number of mountable cards 10BASE-T 10Mbps Cascade connection Maximum 4 tiers QJ71WS96 Base band 100m 100BASE-TX 100Mbps Cascade connection Maximum 2 tiers Auto negotiation function (automatically recognizes 10BASE-T/100BASE-TX) RS-232 compliant (D-sub 9 pin) Full duplex communication Start-stop synchronization 9600,19200,38400,57600,115200bps Maximum 15m 1 8 1 None Flow control (RS/CS control) is available. 0.127 _P HRV-SV outside diameter 8.5mm me (Oki Electric Cable Co., Ltd. _: indicates No. of pairs.) 9-pin D-sub (male) fixed 3.3V5% TYPE I card 1 10

MELSEC Compatible Tool TOOLS Compatible tools Mitsubishi Integrated FA Software MELSOFT GX Developer Version8 General programming tool f greatly improving wk efficiency from designing, debugging to maintenance 1. Dramatically improving operability by utilizing Windows functions. With compliance to Windows 95, Windows 98, Windows Me, Windows NT 0, Windows 2000 Professional and Windows XP programs can be easily designed and debugged using Windows user-friendly operability. Multiple programs and comments, etc., can be edited and monited simultaneously. copy, paste and undo operations can be carried out with a mouse. Copying circuit blocks and commands is available between programs. Data can be input in list fmat on the ladder display screen. (Data is automatically converted into a circuit.) Data can be easily registered from ladder screen with drag & drop, and debugging is available with simple operation such as device tests using Shift double-click on the ladder. 2. Q/QnA/A/FX Series program editing is possible with one package As editing and debugging can be carried out with the same operations f the MELSEC-Q, QnA, A and FX Series, there is no need to learn specified operations f each series. s can be converted and re-used among the Q, QnA and A Series. s can also be converted and re-used between the A and FX Series. As the program can be edited with ladder diagram, lists SFC in each series, designs are suitable f specific application. Comments can be set f each device, to improve the program readability. 3. Use as a remote maintenance tool from a remote location. This software can be used as a maintenance tool remotely by using a public phone line (serial communication, modem interface ) intranet (Ethernet ) as the connection. Motion controller CNC Suppting motion controller, CNC and inverter The PLC functionality built-in inside the following motion controller, CNC and inverter products can be programmed with GX Developer. Compatible models Inverter A171SHCPUN, A172SHCPUN, A173UHCPU, A273UHCPU M60S Series, M600 Series, C6/C64 Series FR-C500 Series Label programming f improving design efficiency s can be standardized by programming with labels. s can be created without having to consider the actual device. s f other systems can be used easily just by changing the device assignment to match the device configuration. s are automatically assigned to labels used internally, so there is no need to consider the devices. (Target CPU: Q00(J), Q01, Q02(H), Q06H, Q12H, Q25H, and QnA Series) Common programs can be translated as parts with function blocks. Large-scale programming can be structured easily. s can be reused to eliminate coding mistakes. Standard programs are displayed as blocks, making the program easy-to-view, and thereby improving the editing and debugging efficiency. Function block can wk with ladder diagram and ST. (Target CPU: Q00(J), Q01, Q02(H), Q06H, Q12H, Q25H, and QnA Series) Improved design efficiency with function blocks Structured text f easy programming of data and communication processes Processes that are difficult to represent with ladders can be programmed easily using structured text (ST). Design efficiency can be improved by representing control processes with ladders, also operation processes, data processes and communication processes with ST. ST programming is equivalent to high level language. The same programming style is applicable f PLC. Design efficiency using parts can be improved as function blocks created with ladders ST can be utilized by ST. (Target CPU: Q00(J), Q01, Q02(H), Q06H, Q12H, and Q25H) MELSEC Q Series Ethernet Interface Module Utilizing fastest industrial standard netwking speed of 100Mbps. Therefe expanding the range of connectable products, and increasing the scope of applicable systems. Version Ver.2 August 1998 Ver.3 Ver.4 Ver.5 Ver.6 Ver.7 Compatible CPU Q Series QnA Series A Series FX Series English version released in March 1999 January 2000 October 2000 May 2001 Ver.8 February 2003 A0J2H, A1S, A1FX, A1SJ, A1SH, A1SJH, A1N, A2C, A2CJ, A2N(S1)A2S, A2SH, A171SH, A172SH, A3N, A2A(S1), A3A, A2U(S1), A2US(S1), A2USH-S1, A3U, A4U, A273UH * The following CPUs are not compatible with GX Developer A1, A2, A3, A3H, A3M, A3V, A52G, A73, A0J2 and F Series. Version upgrade histy September 1999 Q00(J), Q01, Q02(H), Q06H, Q12H, Q25H, Q02(H)-A, Q06H-A Q2A, Q2AS(H), Q2AS1, Q2AS(H)S1, Q3A, Q4A, Q4AR FX0(S), FX0N, FX1, FX1(S), FX2(C), FX2N(C) Histy FX series suppted SFC language compatible Phone line function added Q series compatible FX series, motion controller series FX1SPCU, FX1NCPU, A173UHCPU(S1) additionally suppted FX series compatible SFC suppted Label programming function added compatible Q series (Q mode) suppts multiple CPUs. Basic model QCPU suppted FB function suppted QJ71CMO compatible Windows2000/Me compatible ST language compatible Windows XP compatible QJ71E71-100 (f 10BASE-T/100BASE-TX) QJ71E71-B5 (f 10BASE-5) QJ71E71-B2 (f 10BASE-2) 1. 100BASE-TX high speed transmission. 2. using a commercially available web browser using HTTP communication. The communication library and sample screens used with the PC are provided. 3. Improve debugging efficiency by being able to connect multiple GX Developers'. Use FTP to access files within a multi CPU system. The main program (ASCII fmat) attached files (binary, ASCII CSV fmat) can be sent by e-mail. KeepAlive (Alive check function) that checks the accessibility of the application within an external device. The status of the application sted in the external device, with which the connection was established using TCP/IP protocol, can be monited. Therefe, the connection closing due to an err in the external device can be detected. Type speed Transmission path No. of logical pts Transmission/reception buffer Event interrupt Remote passwd function Compatibility QJ71E71-100 100Mbps/10Mbps 100BASE-TX 10BASE-T QJ71E71-B5 10BASE-5 16 Fixed: 1kW Random: 6kW : 6kW Provided 10Mbps QJ71E71-B2 10BASE-2 Prevent illegal access by registering remote passwd. Compatible with A1SJ71E71/A1SJ71QE71 communication protocol Contact your local Mitsubishi representative 11 12

MELSEC Compatible Tool MELSEC Q Series Serial Module Communicate with external devices via serial communication via modem over a public phone line. 1. Large data (960 wds) high speed communication of up to 230.4kbps (using MC protocol). 2. Read/write PLC CPU data from an external device (personal computer, display, etc.) using MC protocol. ( sequence program is not required.) 3. Transfer data between the PLC and external device (barcode reader, measuring instrument, etc.) using the external device protocol in no-protocol mode. ( sequence program is required.) The PLC can be programmed monited from GX Developer via QJ71C24N(-R2) RS-232 serial communication. The QJ71C24N(-R2) includes the remote communication function, which enables initialization of the modem, and connection to a remote device via the phone line. By using this function, an external device can be connected to remotely with GX Developer. Unauthized access of the Q series PLC with the QJ71C24N(-R2) modem function can be prevented by using the remote passwd function. The circuit trace and communication test function of GX Configurat-SC Version 2 also reduces debugging steps. Type Transmission path *2 Transmission speed Synchronous method Protocol Interrupt function to CPU Compatibility Call back function QJ71C24N RS-232 1ch RS-422/485 1ch 50/300/600/1200/4800/9600/ 14k/19.2k/38.4k/56k/112k/230.4kbps Start-stop synchronization Dedicated, non-procedural, bidirectional Provided Compatible with A1SJ71UC24/A1SJ71QC24N communication protocol Modem communication possible QJ71C24N-R2 RS-232 2ch Peripheral devices can be connected simultaneously to both channels. *2 Transmission speed 230400bps is available f only CH1. (Not available f CH2) Total transmission speed of two interfaces is available up to 230400bps. Transmission speed of up to 115200bps f each interface is available when two interfaces are used simultaneously. QJ71C24N (RS-232 1ch, RS-422/485 1ch) QJ71C24N-R2 (RS-232 2ch) Product infmation Class Product name Type Overview MELSOFT MELSEC Q Series GX RemoteService-I GX Expler GX Developer Web Server Module Ethernet Interface Module SW D5C-RAS-E SW D5C-RAS-EV SW D5C-EXP-E SW D5C-EXP-EV SW D5C-GPPW-E SW D5C-GPPW-EV QJ71WS96 QJ71E71-100 QJ71E71-B5 QJ71E71-B2 Remote access tool Remote access tool (Upgrade) Maintenance tool Maintenance tool (Upgrade) MELSEC PLC programming software MELSEC PLC programming software (Upgrade) compatible F 10BASE-T/100BASE-TX 1ch RS232 1ch F 10BASE-T/100BASE-TX F 10BASE-5 F 10BASE-2 procedure (personal computer and web server software not required) (mail server required to use mail) MELSEC QnA/A Series Modem Interface Module Q6TEL Use this modem interface to connect the modem and PLC CPU. MELSEC QnA/A Series Serial Module Modem Interface Module QJ71C24N QJ71C24N-R2 Q6TEL RS-232 1ch, RS-422/485 1ch RS-232 2ch Interface to connect peripheral device to public phone line 1. Connect to all PLC CPUs in the QnA series and A series by setting the A/QnA select. 2. Unauthized access is prevented by registering a passwd in Q6TEL. Type A/QnA select Connection target CPU Connection cable Interface Phone line Applicable software package If set to QnA All QnA series CPUs Peripheral device connection: Manufactured by user (AC30N2(A) equivalent) Modem connection: Cable enclosed with modem, specified cable RS-232 (When connecting modem, DOS/V PC-9800 series personal computer) SW IVD/NX-GPPQ GPP function software package ( is 2 higher.) Q6TEL If set to A All A series CPUs SW SRXV/NX/IVD-GPPAA GPP function software package ( is 3 higher.) SW2SRXV/NX/IVD-GPPA GPP function software package SW2SRXV/NX/IVD-GPPATEL GPP function software package SW D5C/F-GPPW software package ( is 3 higher.) 13 14

Mitsubishi mable Logic Controller Precautions f Choosing the Products This catalog explains the typical features and functions of the Q series PLCs and does not provide restrictions and other infmation on usage and combinations. When choosing the products, always check the detailed specifications, restrictions, etc. of the products in the Q series data book. When using the products, always read the user's manuals of the products. Mitsubishi will not be held liable f damage caused by facts found not to be the cause of Mitsubishi; machine damage lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special facts unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. F safe use To use the products given in this catalog properly, always read the "manuals" befe starting to use them. This product has been manufactured as a general-purpose part f general industries, and has not been designed manufactured to be incpated in a device system used in purposes related to human life. Befe using the product f special purposes such as nuclear power, electric power, aerospace, medicine passenger movement vehicles, consult with Mitsubishi. This product has been manufactured under strict quality control. However, when installing the product where maj accidents losses could occur if the product fails, install appropriate backup failsafe functions in the system. Country/Region Sales office ELECTRIC CORPORATION HEAD OFFICE: 1-8-12,OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN NAGOYA WORKS: 1-14,YADA-MINAMI 5,HIGASHI-KU,NAGOYA,JAPAN Tel/Fax U.S.A Mitsubishi Electric Automation Inc. Tel : 1-847-478-2100 500 Cpate Woods Parkway Vernon Hills, IL 60061 Fax : 1-847-478-2396 Brazil MELCO-TEC Rep. Com.e Assessia Tecnica Ltda. Tel : 55-11-283-2423 AV. Paulista 1471, Conj. 308, Sao Paulo City, Sao Paulo State, Brazil Fax : 55-11-288-3047 Germany Mitsubishi Electric Europe B.V. German Branch Tel : 49-2102-486-0 Gothaer Strasse 8 D-40880 Ratingen, GERMANY Fax : 49-2102-486-7170 U.K Mitsubishi Electric Europe B.V. UK Branch Tel : 44-1707-276100 Travellers Lane, Hatfield, Herts., AL10 8XB,UK Fax : 44-1707-278695 Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : 39-039-6053344 Centro Dir. Colleoni, Pal. Perseo - Ingr.2 Fax : 39-039-6053312 Via Paracelso 12, 20041 Agrate B., Milano, Italy Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : 34-93-565-3131 Carretera de Rubi 76-80 Fax : 34-93-589-2948 08190 Sant Cugat del Valles, Barcelona, Spain France Mitsubishi Electric Europe B.V. French Branch Tel : 33-1-5568-5568 25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : 33-1-5568-5685 South Africa Circuit Breaker Industries LTD Tel : 27-11-928-2000 Tripswitch Drive, Elandsfontein Gauteng, South Africa Fax : 27-11-392-2354 Hong Kong Ryoden Automation Ltd. Tel : 852-2887-8870 10th Flo, Manulife Tower, 169 Electric Road, Nth Point, HongKong Fax : 852-2887-7984 China Ryoden Automation Shanghai Ltd. Tel : 86-21-6475-3228 3F Block5 Building Automation Instrumentation Plaza 103 Fax : 86-21-6484-6996 Cao Bao Rd. Shanghai 200233 China Taiwan Setsuyo Enterprise Co., Ltd. Tel : 886-2-2299-2499 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Fax : 886-2-2299-2509 Kea HAN NEUNG TECHNO CO., LTD. Tel : 82-2-3660-9552 1F Dong Seo Game Channel Bldg., 660-11,Deungchon-dong Kangsec-ku, Fax : 82-2-3664-8372 Seoul, Kea Singape Mitsubishi Electric Asia Pte, Ltd. Tel : 65-6473-2308 307 Alexandra Road #05-01/02, Fax : 65-6476-7439 Mitsubishi Electric Bulding Singape 159943 Thailand F. A. Tech Co.,Ltd. Tel : 66-2-682-6522 898/28,29,30 S.V.City Building, Office Tower 2, Flo Fax : 66-2-682-6020 17-18 Rama 3 Road, Bangkpongpang, Yannawa, Bangkok 10120 Indonesia P.T. Autoteknindo SUMBER MAKMUR Tel : 62-21-663-0833 Jl. Muara Karang Selatan Blok a Utara No.1 Kav. Fax : 62-21-663-0832 No.11 Kawasan Industri/Pergudangan Jakarta-Utara 14440 India Messung s Put,Ltd. Tel : 91-20-712-2807 Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE-411026,India Fax : 91-20-712-0391 Australia Mitsubishi Electric Australia Pty. Ltd. Tel : 61-2-9684-7777 348 Victia Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Fax : 61-2-9684-7245 When expted from Japan, this manual does not require application to the Ministry of International Trade and Industry f service transaction permission. L(NA)08034E-A New publication, effective May 2004 Specifications subject to change without notice.