IEI 232e Standalone TM Keypad Installation/ Programming Manual



Similar documents
SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

FEATURES AND PROGRAMMING GUIDE COMMANDANDCONTROLSERIES

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Model 201 Wiegand Touchpad Reader Installation Guide

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

CHAPTER 1. GETTING STARTED... 1

Advantium 2 Plus Alarm

e-ask electronic Access Security Keyless-entry

Installation and Operating Manual

Digital Keypad Use s Manual

VARIO PROX CARD READER INSTALLATION MANUAL

Trilogy DL2700 Programming Instructions OI209A 2/04

TAC1 Telephone Entry System Installation and Programming Manual

PAC1 Door Access Controller

User Manual. Humidity-Temperature Chart Recorder. Model RH520

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

LCD5500Z / PKP-LCD v3.x Installation Instructions

PUSH BUTTON START INSTALLATION MANUAL

Automatic Phone-Out Home Monitoring Systems

prox.pad TM plus Access System Installation/ Programming Manual

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

VK-250 WARRANTY REGISTRATION FORM

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Model SRMD Setra Remote Monitoring Display

INSTALLATION MANUAL XM3 Reader

Owner s Manual & Safety Instructions

Digital Fingerprint safe

CA-125 Owner's Manual

Secure Keypads for access control

Trilogy Series DL3000 Programming Instructions

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

PagePac PAGEPAL V

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

PRO PLM Installation Instructions

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

INSTALLER S & OWNER S MANUAL

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

CT-001, CT-001-Solar Owner s Manual

Installation Instructions

InHome Water Leak Detection Package

PR-2500 Portable Receiver. Owner s Manual

for DNE-K07 Reference and Installation Manual

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

CMD-10k COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

AD-01 Slave Auto Dialer. Owner s Manual

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

TS510 & TS500. Installation & User Guide. Compatible Equipment

Single Station Remote Alarm

12 Volt 30 Amp Digital Solar Charge Controller

Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT. Perfect for ANDROID TM

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

User s Information Guide R1A

Utility Distribution Systems

Auto Dialer. Manual E-921APQ E-921GPQ

9452/9453 Installation and User Guide

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Model 940 Proximity Reader. Installation Manual

Weather Radio Alarm Clock

Models CT-001, CT-002 Owner s Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

CAD-05 Kit GSM Auto Dialer. Owner s Manual

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

DP-236Q Wireless Video Door Phone

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

SR-i900 Series. Phone (480)

POWER GEAR SLIDE OUT MANUAL

PK5500 v1.1 Installation Instructions

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

SETTING UP YOUR 6000 SERIES TIME RECORDER

3 WATT LED SPOTLIGHT Model No. SLM

User Manual (English)

3M Wrist Strap and Footwear Tester 740. User s Guide

FIREDEX Conventional Fire Panels

Operation and Installation Manual

INSTALLATION AND OPERATING INSTRUCTIONS

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

WIRELESS HOME ALARM SYSTEM (WHA1)

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

Tina 2A/B Adaptor unit

Leak Detection System

Transcription:

IEI 232e Standalone TM Keypad Installation/ Programming Manual Contents Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: Section 7: Section 8: Section 9: Section 10: Features and Product Description 1.1 Features 1.2 Product Description U.L. Requirements Specifications Mounting Wiring 5.1 Wire Harness Configuration 5.2 Wiring the 232e Keypad to a Maglock (Fail-Safe) 5.3 Wiring the 232e Keypad to an Electric Strike (Fail-Secure) 5.4 Shunting a Normally Closed Zone 5.5 Wiring Remote Trigger as Request to Exit (REX) Button and Door Contacts 5.6 Installing the Plug-On Relay Board 5.7 Wiring the Standalone Access Control Relays Testing the Keypad Programming 7.1 Programming Main Relay Time 7.2 Programming Users 7.3 Programming Keypad Options Troubleshooting Programming Mode Loopback Warranty Manual Revision Date: 05/16/03 Firmware Version: 1.0b Document # 6054004, Rev. 2.1 1

1. Features and Product Description 1.1 Features Flush Mount Indoor and Outdoor Use Keypad Programmable Self-Contained Single Door Access Control Functionality Illuminated Backlit Keys Keypress Feedback via Built-In Sounder Bi-Color Red/Green LED Indicates Relay Status Yellow LED Indicates Program Mode 120 Users 10 to 30 Volt DC Operation 12 to 24 Volt AC Operation 2AmpMainRelay Lock Release Output With Timer Alarm Zone Shunt Relay Propped Door Alarm Relay Forced Door Alarm Relay Remote Trigger Input (REX) 5-Year Warranty 1.2 Product Description The model 232e Keypad is designed for security and is perfect for self-contained access control applications.itfeaturesoutputrelays to release the door lock, to shunt an alarm zone, and to trigger both a propped or forced door alert. Also, the 232e Keypad contains inputs for door monitor and REX. It allows up to 120 users. All e style keypads are designed for both indoor and outdoor flush mount applications. The electronics for each e keypad are conformal coated in the manufacturing process in order to provide this level of application flexibility. In addition, each e style keypad uses hardened keys to assure long-term, high-quality performance. Each e style keypad contains illuminated clear keys that make operation in low-light situations easy and accurate. Installation is easy. All e style keypads mount to any standard single-gang electrical box or directly to any wall. 2 Document # 6054004, Rev. 2.1

2. Specifications Parameter Range/Description Voltage 10-30 VDC, 12-24 VAC 75mA@10VDC, 100mA@30VDC, Current 125mA@12VAC, and 200mA@24VAC Add 20 ma for each alarm relay Environment Indoor and Outdoor Temperature Tolerance -20 F to 130 F Dimensions 4.5" H x 2.75" W x 0.60" D Main Relay (Form C) Alarm Relays: Alarm Shunt, Propped Door, Forced Door Relays (Form C) Contact Rating: Contact Rating: 2A @ 30VAC/DC 1A @ 24V AC/DC Document # 6054004, Rev. 2.1 3

Section3.U.L.Requirements The232ekeypadisaU.L.Listedaccesscontrolunit.Thissection contains information regarding all the requirements necessary to meet U.L. requirements. This system must be installed in accordance with the National Electrical code (NFPA70), local codes, and the authorities having jurisdiction. In addition, all wires and cables used must be stranded andshieldedu.l.listedand/orrecognizedwire. All interconnecting devices (that is, door contacts, REX, locking devices, etc.) must be U.L. Listed. A U.L. Listed access control power limitedpowersupplymustbeusedtopowerthekeypad. A minimum of three user codes must be programmed into the keypad for controlling access. 3.1 Tamper Requirements To meet U.L. requirements, a U.L. Listed tamper switch must be installed in the single gang box used for mounting the keypad. The tamper switch must activate if the keypad is removed from the box and must disconnect power from the lock. The lock must be a failsecure device, meaning the lock remains locked when power is removed. In addition, once the tamper device is activated, it must be configured so that it can only be reset from within the protected area. Only a Sentrol 3012 or Sentrol 3025T tamper switch can be used. The diagrams on the next page show the suggested mounting location for each device. 4 Document # 6054004, Rev. 2.1

Figure 1 Mounting a Sentrol 3012 Tamper Switch Figure 2 Mounting a Sentrol 3025T Tamper Switch Document # 6054004, Rev. 2.1 5

3. Mounting Thekeypadisdesignedtobeflushmountedusingastandardsinglegang electrical box. In addition, itcanbeflushmounteddirectlyto the wall surface by cutting a hole in the wall. To properly size the mounting and wire access hole, use the installation template on the last page of this manual and on the unit s container. Mounting height can vary depending on requirements. An appropriate range is typically between 48 and 52 inches on center off the floor. For outdoor installations, use a weatherproof backbox and seal the wire entry locations with silicone and provide a drain hole. In addition, use the anti-oxidant grease pack for the wire harness connectors. Figure 3 232e Mounting Height 6 Document # 6054004, Rev. 2.1

4. Wiring Figure 4 232e Connector and Wire Harness 4.1 Wire Harness Configuration Pin Wire Color Signal Name 1 Red V+ 2 Black V- 3 White/Black Not Used 4 White/Yellow Not Used 5 Brown Remote Trigger (REX) 6 White/Orange Loop Common 7 White Door Loop Monitor 8 Green Main Relay - Normally Open 9 Blue Main Relay - Common 10 Gray Main Relay - Normally Closed NOTE: For Alarm Shunt, Propped Door, and Forced Door wiring, see sections 4.6 and 4.7. Document # 6054004, Rev. 2.1 7

4.2 Wiring the 232e Keypad to a Maglock (Fail- Safe) Use the following steps to connect the 232e keypad to a Maglock (Fail-Safe): 1. Connect the red wire (V+) to the blue wire (common), and then connect them to the positive on the power supply. 2. Connect the gray wire (normally closed) to the positive on the maglock. 3. Connect the black wire (V-) to the negative on the Maglock, and then connect them to the negative on the power supply. Figure 5 Wiring 232e Keypad to a Maglock (Fail-Safe) 4.3 Wiring the 232e Keypad to an Electric Strike (Fail-Secure) Use the following steps to connect the 232e keypad to an electric strike (fail-secure) (see Figure 6 for reference): 1. Connect the red wire (V+) to the blue wire (common), and then connect them to the positive on the power supply. 2. Connect the green wire (normally open) to the positive on the strike. 3. Connect the black wire (V-) to the negative on the strike, and then connect them to the negative on the power supply. 8 Document # 6054004, Rev. 2.1

Figure 6 Wiring 232e Keypad to Electric Strike 4.4 Shunting a Normally Closed Zone Usethefollowingstepstoemploythe232ekeypadtoshuntanormally closed zone: 1. Connect the blue wire (common) to the common connection on the door position switch. 2. Connect the green wire (normally open) to the normally closed connection on the door position switch. Figure 7 Shunting a Normally Closed Zone Document # 6054004, Rev. 2.1 9

4.5 Wiring Remote Trigger as Request to Exit (REX) Button and Door Contacts Use the following steps to connect the 232e keypad to a normally open REX device and normally closed door switch: 1. Connect the brown wire (REX Input) to the normally open connection the REX device. 2. Connect the white/orange (loop common) to the common on therexdeviceandthecommonthedoorswitch. 3. Connect the white wire (door loop) to the normally closed connection on the door switch. Figure 8 Wiring a REX Button and Door Contacts NOTE: By default, the REX function operates the virtual lock output only, but this can be changed using command 49. In addition, the door loop does not need to be closed for the REX function to operate, by default, but setting option 8 to 0 under command 30 programs the REX function to operate only when the door loop is closed. This prevents the REX from re-triggering when the door is open. 10 Document # 6054004, Rev. 2.1

4.6 Installing the Plug-On Relay Board The Plug-On relay board contains the alarm shunt, propped door, and forced door relays. Output Relay Connector Alarm Shunt K2 P1 Propped Door K3 P2 Forced Door K4 P3 Use the wire harnesses supplied with the relay board to connect totherelays.thewirecolorsareshowninthetablebelow. Wire Color Green Blue Gray Relay Connection Normally Open Common Normally Closed Figure 9 Wiring an Accessory Relay Board Document # 6054004, Rev. 2.1 11

To install the relay board, plug the connector onto P3 on the keypad. The relay must face up towards the keypad wire harness connector P2. Figure 10 Plugging on Relay Board 12 Document # 6054004, Rev. 2.1

4.7 Wiring the Standalone Access Control Relays RelaysK2,K3,andK4providethealarmshunt,proppeddoor,and forced door relays. Use the following steps to wire these relays. NOTE: You MUST wire a normally closed door switch, as shown in Figure 6, for these functions to work properly. 1. (Wiring the alarm shunt) Using P1 (K2), connect the blue wire (common) to common on the door switch. Connect the green wire (normally open) to the normally closed contact on the door switch. 2. (Wiring the propped door alarm) UsingP2(K3),connectthe green wire (normally open) to the positive on the alarm device.connectthebluewire(common)tothepositiveon thepowersupply.connectthenegativeonthealarmdevice to the negative on the power supply. 3. (Wiring the forced door alarm) UsingP3(K4),connectthe green wire (normally open) to the positive on the alarm device.connectthebluewire(common)tothepositiveon thepowersupply.connectthenegativeonthealarmdevice to the negative on the power supply. Figure 11 Wiring an Integrated Accessory Relay Board Document # 6054004, Rev. 2.1 13

5. Testing the Keypad After installing the keypad, IEI recommends that you perform the keypad self-test once a year, to ensure that the keypad works properly. 1. To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890#123456* If all 12 keypresses are accepted, the keypad enters self-test mode. The LEDs alternate green, yellow, and red followed by the sounder beeping three times. 2. Verify that the master code works correctly. (The master code accesses program mode and activates the main relay to verify that the locking device is working.) The default master code is 1234. 14 Document # 6054004, Rev. 2.1

6. Programming To program the 232e keypad, you must first enter program mode by pressing 99 # Master Code *. The default Master Code is 1234. 6.1 Programming Main Relay Time Command/Action Keys to Enter/Details Command 11, Set Main Relay Time Command 44. Set Propped Door Time Options: time 11 # time # 0 # ** (Time can be from 1-255 seconds.) 44 # time # 0 # ** ProppedDoorTime-roundeddownto nearest 10 s of seconds; entered as 00, 10 through 990, defaults to 30 seconds; entering atimeofzerodisablesthefunction Command 45. SetForcedDoorTime Options: time Forced Door Time - rounded down to nearest 10 s of seconds; entered as 00, 10 through 990, defaults to 10 seconds; entering a time of zero latches the virtual forced door that can beclearedwithanyvalidpinorbyentering program mode Document # 6054004, Rev. 2.1 15

6.2 Programming Users Command/Action Master Code Keys to Enter/Details User #1 is the master code; it can access all commands in program mode. The default code is 1234. User #2, when programmed, is the supervisor code. The supervisor can access program mode, but is limited to adding and deleting users, as Supervisor Code well as enabling or disabling users. The supervisor code can not change, delete, or disable the master code or supervisor code itself. Add User user location # code * code * Add User with Specific Unlock Time unlock time # user location # code * code * (This command is used to program a user with a specific unlock. This user activates the main relay.) Add Toggle User 0 # user location # code * code * (This user latches the main relay.) Delete User user location # * * Command 56. Enable/Disable User 56 # enable/disable # user location # * * Options: 1 = Disable 0 = Enable The master code and supervisor code cannot be disabled. 16 Document # 6054004, Rev. 2.1

6.3 Programming Keypad Options Command/Action Command 30. Enable/Disable keypad options Keys to Enter/Details 30 # option # enable/disable # * * Option Set/Clear 0 - audio keypress feedback 0=disabled, 1=ENABLED 1 - visual keypress feedback 0=disabled, 1=ENABLED 2 - auto-entry enable 0=DISABLED, 1=enabled 3 - error lockout 0=disabled, 1=ENABLED 6 - keypad illumination 0=disabled, 1=ENABLED 7 - keypad dimming 0=disabled, 1=ENABLED 8 - REX operation 0=only when door loop closed 1=always Defaults are in bold. Auto-entry Error Lockout Keypad Illumination Keypad Dimming IEI 232e Standalone Installation/Programming Manual When auto-entry is enabled, users with codes the same length as the master code donothavetopressthe*keyafter entering their code. If you have a code greater than the master code, you can use Auto-Entry Suspend. Just enter the # key prior to your code followed by the * key. Example: # 23456 * if the master code is four digits. When enabled, the keypad keeps track of the number of consecutive invalid codes entered, including attempts to access program mode. When the threshold is reached, the yellow LED turns on solid and the keypad no longer responds to key pressesfortheprogrammedtimeduration. The count is reset by entering a valid code, including entering program mode. The error lockout threshold and duration is programmed with command 32. Keypad backlighting can be enabled or disabled. When enabled, the backlighting illumination level decreases 15 seconds after the last key press. When disabled, the backlighting remains at full illumination at all times. Document # 6054004, Rev. 2.1 17

Command Action Keys to Enter/Details Command 32. Change Keypad Parameters 32 # parameter # value # * * Parameter Value 2 - error lockout threshold 1 through 50 (defaults to 3) 3 - error lockout duration 1 through 255 (defaults to 10) Command 40. Reset defaults only. Command 46. Erase Users and Reset Default Settings. 40 # 00000 # 00000 # ** (master code, all keypad options and parameters) 46 # 00000 # 00000 # ** 18 Document # 6054004, Rev. 2.1

7. Troubleshooting Refer to this section if the 232e keypad is not operating correctly as described in this manual. Problem Solution The LEDs are slowly cycling from right to left and backlighting is off. The LEDs are rapidly cycling from left to right and the keypad has lost all operation. Themastercodedoes not work. No LEDs are lit on the keypad The 232e keypad is designed to monitor the input voltage and this is an indication of under-voltage. The under-voltage threshold is set to 8.5VDC, and when the voltage drops below this limit, the low voltage warning starts and backlighting is turned off. To solve, raise the voltage to between 12-24V. The 232e keypad is designed to monitor the input voltage, and this is an indication of over-voltage. The over- voltage threshold is set to 36VDC, and when the voltage rises above this limit, the over-voltage warning starts and the keypad loses all operation. To solve, lower the voltage to between 12-24V. Perform the programming mode loopback and reset the master code using the programming command. Power is not reaching the keypad. Using a voltmeter, confirm that there is voltage at the keypad on the red and black wires. If there is no voltage at the keypad, verify that there is voltage at the power supply. If there is no voltage at the power supply, call the manufacturer of the power supply. If there is voltage at the power supply but not at the keypad, verify there is no break in the wires, then check continuity in the whole length of the wire run. To verify that the keypad is working, you can power the keypad with a 12-Volt Battery. If the 232e Keypad still does not work after troubleshooting, please call IEI s technical support department at 1-800-343-9502 (outside MA) or 1-800-733-9502 (inside MA). Operating hours are Monday through Friday from 8:00 A.M. to 7:00 P.M. Eastern Standard Time. Document # 6054004, Rev. 2.1 19

8. Programming Mode Loopback If the master code is either not working or forgotten, power down the system, connect the wire harness as shown in Figure 12 below, and then power the system up again. Next, change your master code and power down the system and restore the wire harness to its original configuration and power the system back up. Figure 12 Programming Mode Loopback Standalone First, disconnect power from the system. Next, connect the White/YellowwiretotheBrown(REX)andWhitewireasshown in Figure 12. Finally, power up the keypad again. 20 Document # 6054004, Rev. 2.1

9. Warranty International Electronics Inc. (IEI) warrants its products to be free from defects in material and workmanship when they have been installed in accordance with the manufacturer s instructions and have not been modified or tampered with. IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage, handling, abuse, misuse, normal wear and tear, or an act of God. IEI s sole responsibility is limited to the repair (at IEI s option) or the replacement of the defective product or part when sent to IEI s facility (freight and insurance charges prepaid) after obtaining IEI s Return Material Authorization. IEI will not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in, or malfunction of, its products. Except as stated above, IEI makes no warranties, either expressed or implied, as to any matter whatsoever, including, and without limitation to, the condition of its products, their merchantability, or fitness for any particular purpose. Warranty Periods Are: 1Year PowerKey 2 Years Door Gard & Secured Series Products 2 Years LS Series 2 Years Glass Break 5 Years 'e' Series Keypads Allproductshavedatecodelabelingtodeterminethewarrantyperiod.A 90-day grace period is added to all products to account for shelf life. Document # 6054004, Rev. 2.1 21