Energy Efficient Grain Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer



Similar documents
High Moisture Corn Drying and Storage. Kenneth Hellevang, Ph.D., P.E. Extension Engineer & Professor

Grain Drying Concepts and Options

Managing Stored Grain

Walnut Drying Design and Operation. Selecting Dryer Type. Tray Drying Before Don Osias Jim Thompson

UNIVERSITY OF ARKANSAS DIVISION OF AGRICULTURE RESEARCH AND EXTENSION COOPERATIVE EXTENSION SERVICE ON-FARM SOYBEAN DRYING AND STORAGE

Principles of Rice Drying How does rice dry?

On-Farm Drying and Storage of Soybeans

Grain Drying & Management Bob Schultheis Natural Resource Engineering Specialist University of Missouri Extension

Natural Air Drying Corn Paul E. Sumner University of Georgia Biological and Agricultural Engineering Department

Harvesting, Drying, and Storing Malting Barley

Climatography of the United States No

Climatography of the United States No

THE PSYCHROMETRIC CHART AND ITS USE

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Soybean Production in Kentucky

Award-Winning Innovation in Data Center Cooling Design

Climatography of the United States No

HVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.

Environmental Data Center Management and Monitoring

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates

Greenhouse Cooling. Why is Cooling Needed?

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

Sea Water Heat Pump Project

UNDERSTANDING REFRIGERANT TABLES

Low Cost. Lower Energy Costs. Higher Efficiency.

Corn Harvesting, Handling, Drying, and Storage

How do I measure the amount of water vapor in the air?

Tips and Tricks for Estimating Energy Savings. Celeste Cizik, P.E. Project Manager E M C Engineers, Inc.

Direct Fresh Air Free Cooling of Data Centres

Multifamily Central Heat Pump Water Heating

RTO UPGRADE PROVIDES COST SAVINGS AND PERFORMANCE IMPROVEMENTS

Energy Efficiency. Energy Efficient Home Cooling:

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Using Wet-Bulb Economizers. Data Center Cooling

Product Data Bulletin

Evaporative Cooling System for Aquacultural Production 1

Pool Dehumidification Basics

Purpose: To determine the dew and point and relative humidity in the classroom, and find the current relative humidity outside.

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Refrigeration Basics 101. By: Eric Nelson

Heat Recovery In Retail Refrigeration

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

Case Studies: Infrared Heating in Industrial Applications

CONDENSATION. Section Break (Next Page)

Wet Bulb Temperature and Its Impact on Building Performance

KILN SCHEDULES HARDWOOD KILN SCHEDULES KILN SCHEDULES KILN SCHEDULES KILN SCHEDULES KILN SCHEDULES

Analysis One Code Desc. Transaction Amount. Fiscal Period

How To Understand Evaporator

White Paper #10. Energy Efficiency in Computer Data Centers

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Advanced Heat Reclaim Systems. Harrison Horning, PE, CEM Delhaize America - Hannaford

Grain Stocks Estimates: Can Anything Explain the Market Surprises of Recent Years? Scott H. Irwin

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Refrigeration Manual. Part 3 - The Refrigeration Load

NSIDC Data Center: Energy Reduction Strategies

Managing Heat Stress in Poultry

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

6. Base your answer to the following question on the graph below, which shows the average monthly temperature of two cities A and B.

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Green Data Center: Energy Reduction Strategies

Solar Panels Inside a Greenhouse for Transplant and Crop Production

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

The New Data Center Cooling Paradigm The Tiered Approach

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Analysis of data centre cooling energy efficiency

The Climate of Oregon Climate Zone 2 Willamette Valley

How To Use A Water Source Heat Pump

HVAC. Kitchen Exhaust. rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier!

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

The Fallacies of Venting Crawl Spaces January 3, 2002 Craig DeWitt, PhD, PE

Centrifugal Fans and Pumps are sized to meet the maximum

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

AT&T Global Network Client for Windows Product Support Matrix January 29, 2015

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Design of Closed-loop Fumigation Systems for Grain Storage Structures

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

GEOTHERMAL HEATING AND COOLING INTRODUCTION

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Dealing with Thermal Issues in Data Center Universal Aisle Containment

HVAC FORMULAS. CFM = BTU/Hr / ( 1.08 x Temperature Difference) TON OF REFRIGERATION -

Temperature and Humidity

Basic Nameplate Information

Sino-Italian Environment & Energy Building S I E E B

HVAC Systems: Overview

BRUNS-PAK Presents MARK S. EVANKO, Principal

Residential Energy Consumption: Longer Term Response to Climate Change

10 Strategic Steps to Reducing Your Energy Costs AEE Regional Chapter Meeting February 2, 2005

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Rusty Walker, Corporate Trainer Hill PHOENIX

MONITORING THE USE OF WATER ON GRAIN

Energy Saving Ideas for Your Box Plant

Transcription:

Energy Efficient Grain Drying Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Estimated Corn Field Drying PET=Potential Evapotranspiration EMC (%) PET (in) Est. Drying (%pt) Month Week Sep 15 4.0-5.0 18 4.5 Oct 16 2.8-3.5 11-12 2.5 Nov 19 0.8-1.2 4-5 1 Dec 20 0.5-0.8 2 0.5 Jan 21 0.5-0.8 2 0.5 Feb 21 0.5-0.9 3 0.8 Mar 19 1.3-1.6 5 1 Apr 16 3.2-4.5 16 4 May 14 6.5-8.5 30 7 NDAWN, Weather, Total PET, Estimate:1-inch = 4% drying EMC-equilibrium moisture content, GDD-growing degree days

Natural Air Drying Natural air drying, if properly designed and managed, is the most energy efficient drying. It is not efficient or effective on very wet grain or at November-March temperatures.

Effect of Supplemental Heat When NA/LT Drying Wheat 17% initial M.C., 0.75 cfm/bu, 10,000 bu Bin, $0.10 electric heat, $8.00/bu., ND Climate Adding heat increases drying and shrink cost. Only warm the air 5 F when necessary to reduce grain moisture. Use a controller. Temp ( F) RH (%) EMC (%) Drying Time (Days) Ave Sep 58 65 14.4 -- +3 Fan 61 58 13.5 31 Shrink Cost Heat Cost Overdry Cost 10 + 3 71 41 10.8 27 $2,424 $1567 $3,991 Ave Oct Cold Sep 47 65 15.0 -- +3 Fan 50 58 13.9 39 10 + 3 60 40 11.0 37 $2,248 $2,130 $4,378 Humid Sep 58 75 16.1 -- +3 Fan 61 67 14.6 40 10 + 3 71 47 11.6 28 $1,720 $1613 $3,333 5 + 3 66 56 12.9 32 $552 $807 $1359

Natural Air and Low Temperature Corn Drying 21% Initial Corn Moisture Content, Average ND Climatic Conditions Drying Time (Days) Month & added heat Temp. ( F) RH EMC 1.0 cfm/bu 1.25 cfm/bu Oct. +3 F (fan) 50 58% 13.5% 42 34 Oct. 15 Nov +3 F (fan) 37 66% 15.8% 65 52 Nov. +3 F (fan) 30 64% 16.0% 70 56 Nov. +3 F (fan)+2 F 32 58% 14.6% 65 52 Nov. +10 F 37 48% 12.5% 51 41 NA/LT corn drying works well until outdoor temperatures approach freezing, then becomes inefficient.

Natural Air & Low Temperature Corn Drying Month & added heat Spring Drying North Dakota Climate Ave. Temp (ºF) RH Corn EMC Drying Time (Days) 1.0 cfm/bu 1.25 cfm/bu Apr 42 65% 15.3% 51 41 +5ºF 47 54% 13.3% 46 37 May 56 60% 13.5% 43 34 Natural air drying is very efficient in the spring. Start fans when outdoor temperatures average about 40 F.

Fan Type Comparison Corn: 27 ft. diameter, 20 ft. deep, 10 hp fan Fan cfm Airflow Rate (cfm/bu) AF 24 (Axial Flow) 8,673 0.95 ILC (In-line Centrifugal) LSC (Low-speed Centrifugal, 1750 rpm) HSC (High-speed Centrifugal, 3500 rpm) 7,232 0.79 10,117 1.10 5,824 0.64 Typically the low speed centrifugal fan moves the most airflow per horsepower through corn, so is the most efficient.

Fan Power Required Airflow Rate Corn Depth (ft) 16 18 20 22 24 (cfm/bu) ----- hp per 1,000 bu ----- 1.0 0.6 0.8 1.1 1.3 1.7 1.25 1.1 1.4 1.8 2.3 2.9 1.5 1.7 2.2 2.9 3.6 4.5 Horsepower calculated based on a 42 ft diameter bin 42 ft diameter bin, corn 36 ft deep, 1.0 cfm/bu Fan = 180 hp, static pressure = 17-inches wg.

Stirring Batch Bin Dryer 8-15 cfm/bu. Maximum drying rate obtained with shallow depth. Use maximum temperature that will not damage the grain. Stirring limits over-drying. Drying temperature up to ~160ºF.

Continuous Flow Bin Dryer Maximum drying rate with about 6-8 ft. corn depth Again use maximum air temperature and limit grain depth to maximize dryer capacity and efficiency. Cooling is done in a separate bin.

Cross-Flow Dryer Batch Dryer A traditional cross-flow dryer requires about 2,500 Btu to remove a pound of water from corn.

Energy requirements of a conventional cross-flow dryer as a function of drying air temperature and airflow rate. (University of Nebraska) Energy required to remove a pound of water is reduced at higher plenum temperatures and lower airflow rates. Use the maximum temperature that will not damage the grain.

Heat and Cool Batch Inside wall hotter. (Loss of grain quality and efficiency)

Pressure Heat, Pressure Cool

Full Heat Continuous Flow Best capacity, bu./hr., for dryer size and cost Heat in grain drives out moisture in the bin In-bin cooling - Needs full floor aeration and moisture management Better efficiency and quality than pressure cool

Two Heat Continuous Flow Slightly better quality than single zone Efficiency loss in lower plenum Same dryer can also do pressure cool FH needs aeration and moisture management

Pressure Heat, Suction Cool Capacity loss to full heat Cooling air is recycled to fan inlet Efficiency gain over full heat Partial cooling with aeration Needs little management

Vacuum Cooling Vacuum cooling increases drying energy efficiency by 20% to 30%. This may be more beneficial in cold northern climates.

Pressure Heat, Suction Cool with Heat Reclaim Lower heat zone recycled Best efficiency. Needs little management

Fuel Cost Cost per bu. $1.85 gal. Propane, $.10/kWh 5% Pt. Removal Pressure Heat Pressure Cool 16.0 Full Heat 13.1 Pressure Heat Vacuum Cool 12.5 Pressure Heat Vacuum Cool Heat Reclaim 9.0

Dryer Improvements Staged Temperature Grain Turner or Inverter Using a higher plenum temperature on the wettest grain reduces energy consumption. A grain turner or inverter reduces over-drying, moisture variation and excessive kernel temperatures.

Differential Grain Speed Dryer Increasing the grain flow rate near the plenum reduces excessive grain temperatures and creates a more uniform grain moisture content coming from the dryer.

Moisture Equalizers Moves inside wall faster Less variation of moisture across column Better test weight (1 to 4 lbs./bu.) Able to dry at 10 to 20 deg F higher temps with same grain quality (10 deg = 4% energy savings and 8% capacity increase )

Variable Width Column Saturated air 8-12 Heat Zone 12 Heat Zone 12 Cool Zone

Efficiency Fan Selection Important 85% 80% 75% SQ8 VA Corn Design range Wheat 70% 65% 60% SQ12 VA SQ16 VA SQ16 Cent Brock Q VA Centrifugal 55% 50% 45% 40% 35% 30% 25% Vane Axials 20% 15% 10% 5% 0% 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Static Pressure

Mixed Flow Dryer A mixed flow dryer uses a lower airflow rate per bushel than a cross-flow dryer which increases energy efficiency. The moving grain design minimizes exposure to the hot plenum air which reduces the potential for grain damage. Airflow Rate=40-45 cfm/bu.

Drying Cost Increases at Colder Temperatures High Temperature Drying @ $1.10/gal propane 2.4 /bu-pt. 21% to 15.5% 2,500 Btu/lb of water Outside Temp. % Increase Cost /bu 40 --- 13.2 20 114 15.0 0 129 17.0-20 142 18.7 With Air Recirculating 2,000 Btu/lbw 1.9 /bu-pt. @ 40 F 10.5 /bu Dry when it is warmer if possible, since it takes more energy to dry at colder temperatures.

Heat of Vaporization Drying Cereal Grains Brooker, Bakker-Arkema, Hall Water Heat of Vaporization = 1,070 Btu/lb @ 40 F Minimum energy to evaporate water from corn is about 1,200 Btu per pound. Realistic dryer minimum is probably about 1,500 Btu.

Dryeration Dump hot, temper without airflow 4-6 hrs, cool Extensive condensation - must move corn to another bin Moisture reduction: 0.25%/10 F cooled, 2.5% Increases dryer capacity 50%-70%, Reduces energy by about 15%-30% Dryeration reduces energy consumption by about 25%, but it is imperative to move the corn to another bin for storage to prevent storage problems.

In-Storage Cooling Immediately cool, Airflow rate 12 cfm/bu-hr of fill rate About 1-1.5 percentage point moisture reduction (0.1 0.15 / 10ºF) Reduce condensation if below 50ºF by partial cooling in the dryer typically to about 90 F In-storage cooling requires rapid cooling and cooler initial grain temperature to limit condensation. Slow cooling saves more energy, but storage problems typically occur near the bin wall.

Grain Dryer Energy Audit Existing energy use Expected new system energy use Energy savings Simple payback

Existing Energy Usage Bushels of corn dried : 239,592 bu. dry bushels Average initial moisture content: 23.69% Average final moisture content: 14.72% Water removed from the corn per bushel: 6.52 lb. Corn weight: 62.01 lbs. at 23.69% moisture 55.49 lbs. at 14.72% moisture content This is not a normal percentage or shrink calculation!!

Energy per Pound of Water Corn dried = 239,592 dry bushels Fuel Used = 45,916 gallons of propane Propane per bushel = 0.1916 gal. Energy per bushel = 17,554 Btu Water removed per bushel = 6.52 lb. Energy per pound of water removed 17,554 Btu / 6.52 lb = 2,692 Btu/lb water

New Dryer Estimated Energy Usage

For More Information Search for: NDSU Grain Drying & Storage