Dynamic IR Scene Projector Based Upon the Digital Micromirror Device



Similar documents
Overview Presented by: Boyd L. Summers

III. MEMS Projection Helvetica 20 Displays

Advanced Micro Ring Resonator Filter Technology

A GPS Digital Phased Array Antenna and Receiver

Report Documentation Page

REPORT DOCUMENTATION PAGE

Simulation of Air Flow Through a Test Chamber

Headquarters U.S. Air Force

UNCLASSIFIED LOW-COST MINIATURE INTERFACE AND CONTROL SYSTEMS FOR SMART SENSORS, TACTICAL RADIOS, AND COMPUTER NETWORKS

Using the Advancement Degree of Difficulty (AD 2 ) as an input to Risk Management

EAD Expected Annual Flood Damage Computation

Asset Management- Acquisitions

John Mathieson US Air Force (WR ALC) Systems & Software Technology Conference Salt Lake City, Utah 19 May 2011

Fig.1. The DAWN spacecraft

OPTICAL IMAGES DUE TO LENSES AND MIRRORS *

DEFENSE CONTRACT AUDIT AGENCY

73rd MORSS CD Cover Page UNCLASSIFIED DISCLOSURE FORM CD Presentation

Technical Data FLIR E40bx (incl. Wi-Fi)

Optical Blade Position Tracking System Test

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

THE MIMOSA OPEN SOLUTION COLLABORATIVE ENGINEERING AND IT ENVIRONMENTS WORKSHOP

PROBLEM STATEMENT: Will reducing the ASD for Kadena AB F-15 C/Ds increase the CPFH for this Mission Design Series (MDS)?

DMD 101 Introduction to DMD technology

Guide to Using DoD PKI Certificates in Outlook 2000

Cancellation of Nongroup Health Insurance Policies

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DCAA and the Small Business Innovative Research (SBIR) Program

Pulse width modulation control in DLP TM projectors

Mr. Steve Mayer, PMP, P.E. McClellan Remediation Program Manger Air Force Real Property Agency. May 11, 2011

THE FLATWORLD SIMULATION CONTROL ARCHITECTURE (FSCA): A FRAMEWORK FOR SCALABLE IMMERSIVE VISUALIZATION SYSTEMS

Thermal Imaging Test Target THERMAKIN Manufacture and Test Standard

Technical Data. FLIR T (incl. Wi-Fi)

Issue Paper. Wargaming Homeland Security and Army Reserve Component Issues. By Professor Michael Pasquarett

SHOALS Toolbox: Software to Support Visualization and Analysis of Large, High-Density Data Sets

Small PV Systems Performance Evaluation at NREL's Outdoor Test Facility Using the PVUSA Power Rating Method

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Synthetic Sensing: Proximity / Distance Sensors

CERT Virtual Flow Collection and Analysis

Metamaterials and Transformation Optics

FIRST IMPRESSION EXPERIMENT REPORT (FIER)

Microstructural Evaluation of KM4 and SR3 Samples Subjected to Various Heat Treatments

RT 24 - Architecture, Modeling & Simulation, and Software Design

Pima Community College Planning Grant For Autonomous Intelligent Network of Systems (AINS) Science, Mathematics & Engineering Education Center

Color holographic 3D display unit with aperture field division

Non-Autoclave (Prepreg) Manufacturing Technology

High Power Density Capacitor Charging Power Supply Development for Repetitive Pulsed Power

AFRL-RX-WP-TP

ABSTRACT 1. INTRODUCTION

MAR MEMS 2D Laser Scanning Mirror Data Sheet Rev 2

3D Input Format Requirements for DLP Projectors using the new DDP4421/DDP4422 System Controller ASIC. Version 1.3, March 2 nd 2012

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

Digital Micromirror. Device (DMD )

ELECTRONIC HEALTH RECORDS. Fiscal Year 2013 Expenditure Plan Lacks Key Information Needed to Inform Future Funding Decisions

Dual Laser InfraRed (IR) Thermometer

S300. Big Screen Viewing. Bright projection 2800 ANSI Lumens. SVGA resolution, 15,000:1 contrast ratio. Low ownership costs - up to 6500 hrs lamp life

Disturbance Recoder SPCR 8C27. Product Guide

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Mobile Robot Knowledge Base

In June 1998 the Joint Military Intelligence. Intelligence Education for Joint Warfighting A. DENIS CLIFT

Digital PC input: UXGA/SXGA+/ WXGA/SXGA/XGA/SVGA/VGA

Military Health System Conference

ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture

5.3 Cell Phone Camera

Digital Camera Imaging Evaluation

Full Waveform Digitizing, Dual Channel Airborne LiDAR Scanning System for Ultra Wide Area Mapping

Nederland België / Belgique

An Introduction to the MTG-IRS Mission

16 th IOCCG Committee annual meeting. Plymouth, UK February mission: Present status and near future

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

3.2 inch QVGA TFT Color LCD User s Guide Version 1 & 2

CAPTURE-THE-FLAG: LEARNING COMPUTER SECURITY UNDER FIRE

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Ultra-low Sulfur Diesel Classification with Near-Infrared Spectroscopy and Partial Least Squares

RESULTS FROM A SIMPLE INFRARED CLOUD DETECTOR

Award Number: W81XWH

Hello and welcome to this training module for the STM32L4 Liquid Crystal Display (LCD) controller. This controller can be used in a wide range of

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications

Dual Laser InfraRed (IR) Thermometer with Color Alert

Cross-beam scanning system to detect slim objects. 100 mm in

Thermal Imaging Camera Module C200/C250 series

Integrated Force Method Solution to Indeterminate Structural Mechanics Problems

Wave Breaking and Wave Driven Flow in the Nearshore

In-Sight Hardware specifications

Specification MBT801-S

An Application of an Iterative Approach to DoD Software Migration Planning

IR Receiver Module for Light Barrier Systems

Frequency Converter Fv

Acousto-optic modulator

Transcription:

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device D. Brett Beasley, Matt Bender, Jay Crosby, Tim Messer, and Daniel A. Saylor Optical Sciences Corporation www.opticalsciences.com P.O. Box 8291 Huntsville, AL 35808 ABSTRACT Optical Sciences Corporation has developed a new dynamic infrared scene projector technology called the Micromirror Array Projector System (MAPS). The MAPS is based upon the Texas Instruments Digital Micromirror Device (DMD) which has been modified to project images which are suitable for testing sensor and seekers operating in the UV, visible, and IR wavebands. The projector may be used in several configurations which are optimized for specific applications. This paper provides an overview of the design and performance of the MAPS projection system, as well as example imagery from prototype projector systems. Keywords: Infrared, Scene Projection, Digital Micromirror Device, Simulation, FPA testing, Hardware-in-the-loop. 1.0 INTRODUCTION Optical Sciences Corporation (OSC) has developed a new dynamic IR scene projector technology called the Micromirror Array Projector System (MAPS) which is based upon the Texas Instruments Digital Micromirror Device (DMD ). This projector technology is capable of producing very realistic dynamic scenes in the UV, visible, and IR wavebands. The projector technology offers several attractive features including high spatial resolution, high frame rates, no dead pixels, and excellent uniformity. The projector may be used in several configurations which are tailored to specific applications. OSC has successfully demonstrated three prototype configurations of the Micromirror Array Projector System (MAPS) operating in both binary and pulse width modulation (PWM) mode. These configurations include a one-dmd MWIR projector, a two- DMD MWIR projector, and an IR and visible Dynamic Sensor Test Set (DSTS). 2.0 DIGITAL MICROMIRROR DEVICE BACKGROUND The DMD is a micro-electromechanical system (MEMS) which has a 2-D array of individually controlled aluminum micromirrors. The DMD is the spatial light modulator in TI s Digital Light Processing (DLP ) system. DLPs are manufactured by TI and sold to OEMs for use in display products such as business projection systems. DMDs are currently commercially available in formats up to 1024x768, and 1280x1024 DMDs are expected to reach the market in the near future. Figure 1 shows a 1024x768 DMD package, and Figure 2 is an SEM image of the micromirrors with a grain of salt on the surface of the device. As depicted in Figure 3, each micromirror in the DMD can reflect light in one of two directions (±20 optical) depending upon the state of the underlying memory cell (SRAM). With proper illumination, each mirror will reflect light into the pupil of the optical system when a 1 is written to its SRAM and out of the optical system when a 0 is written to its SRAM. The device is therefore binary in nature. The switching speed on the individual mirrors is approximately 10 usec. In commercially available visible projector systems, intensity control is achieved by binary Pulse Width Modulation (PWM). The binary image on the array can be updated at a rate of approximately 5000 Hz, and a global reset allows the entire image to be cleared in less than 20 usec. Figure 1 DMD

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 2001 2. REPORT TYPE 3. DATES COVERED 00-00-2001 to 00-00-2001 4. TITLE AND SUBTITLE Dynamic IR Scene Projector Based Upon the Digital Micromirror Device 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Optical Sciences Corporation,PO Box 8291,Huntsville,AL,35808 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution unlimited 13. SUPPLEMENTARY NOTES The original document contains color images. 14. ABSTRACT 15. SUBJECT TERMS 11. SPONSOR/MONITOR S REPORT NUMBER(S) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified 18. NUMBER OF PAGES 7 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

Figure 2: DMD with Grain of Salt on Surface Figure 3: DMD Illumination 3.0 ISSUES FOR APPLICATION OF THE DMD TO IR PROJECTION Because the DMD was designed for visible projection and human perception, several technical issues had to be addressed for it to be used as a dynamic IR scene projector. These issues included temporal aliasing due to PWM, limited dynamic range due to diffraction of the small mirrors, exit pupil illumination, and spectral transmission of the window covering the DMD. All of these issues have been addressed in the OSC design. The most significant issue for application of the DMD to IR scene projection is the temporal aliasing due to PWM. The PWM technique controls the intensity of each pixel by setting the percentage of time each mirror is in the on position within a given time frame. A sensor with a long integration time (relative to the switching speed of the mirrors) will perceive an intensity of each pixel which is related to the amount of time each mirror is in the on position. The standard electronics in the DLP projector systems are designed to generate three 8-bit colors at a 60-85 Hz frame rate using PWM. Thus, it takes approximately 5.5 msec to generate an 8-bit PWM image. If a sensor has an integration time of less than 5.5 msec. (such as most InSb FPAs), it will perceive temporal aliasing when viewing a DMD with standard electronics. A rolling integration scheme within the FPA will also contribute to the aliasing problem. The OSC projector design has addressed this issue by designing custom control electronics to drive the DMD in synchronization with the FPA integration and by using other configurations to eliminate the need for PWM. A second concern for application of the DMD to IR scene projection is the reduction in contrast due to the diffraction of light by the mirrors. Because the mirrors are not significantly larger than the wavelength of light, potentially significant diffraction of the light reflected from the DMD may occur. Because the tilt angle of the mirror is limited to 20 degrees this diffraction will reduce the contrast ratio of the device as the wavelength of the light increases. In the visible band, a contrast ratio of 400:1 is typical. Although the contrast ratio drops to ~90:1 in the MWIR, this still provides a very good apparent temperature range. The dynamic range of a DMD projector system can be optimized in the illumination design, however for our applications, the optics must also be designed to uniformly illuminate the exit pupil of the system. Another significant issue for application of the DMD to scene projection for bands other than the visible is the transmission of the window covering the DMD. The window material used in the DMD will not transmit wavelengths significantly outside the visible band such as the MWIR band. Therefore, an IR transmitting window had to be installed on the DMD. OSC has developed a technique for removing the visible window and installing a window which will transmit in the waveband of choice. OSC has successfully replaced the windows on several DMDs with IR transmitting windows, while maintaining 100% operability of the mirrors.

4.0 MICROMIRROR ARRAY PROJECTOR SYSTEM OSC has developed a DMD-based IR projector which is capable of generating realistic IR images for advanced testing of IR seekers, sensors, and FLIRS. Applications of the projector include hardware-in-the-loop testing, portable test sets, built-in testing, production line testing and training. The MAPS is capable of operating in two modes: flickerless binary and PWM. In binary mode, the projector is virtually flickerless, with only a brief reset occurring each frame to prevent hinge memory in the micromirrors. The projector is compact and can be produced at a low-cost compared to other IR projector technologies. 4.1 MAPS Design The projector consists of a customized DMD, illumination source, collimating optics, and custom drive electronics. A photograph of the system is shown in Figure 4. The DMD was modified for use in the IR by replacing the standard window with an IR transmissive window. A technique for replacing the window without the loss of any mirrors was developed by OSC. OSC has modified several DMDs which have 100% mirror operability. The DMD has a format of 848x600, and a binary frame rate of 4065 Hz. A broadband IR source is used for illumination and was designed to ensure that the exit pupil was uniformly illuminated. The prototype system includes an f/4 MWIR collimator which has an exit pupil relief of 18 inches. The custom drive electronics were designed to be programmable such that any combination of gray scales, frame rate, and PWM frequencies (within the capabilities of the DMD) can be generated. In its most basic mode, the DMD can be operated in a single-bit flickerless control. In this mode, binary images can be generated at high frame rates and there is no minimum integration time required for the UUT. In binary mode the MAPS is projecting the scene for ~97% of the frame time. During the remaining 3% of the frame time the mirrors are allowed to go to a rest state to prevent hinge memory. The timing of this rest event can be synchronized to the UUT so that it occurs during a time when the sensor is not integrating or during the flyback time of a scanning sensor. The rest time can actually be eliminated if necessary, however the lifetime of the device may be reduced. Give the reported MTBF lifetimes of greater than 100,000 hours for these devices, this would probably not be a problem for most applications. The system can also be programmed for varying PWM frequencies to match the integration time of the sensor. The longer the sensor integration time, the more intensity levels that can be achieved. As an example, a typical integration time for an InSb FPA camera is 3 msec. With this integration time, the DMD can generate 128 (7-bits) intensity levels. Because of the DMDs binary nature, the intensity levels are very accurate and linear. Figure 4: Micromirror Array Projector System

4.2 MAPS Performance Table 1 below summarizes the performance characteristics of the MAPS projector. Parameter Performance Spectral Range UV to LWIR available. Determined by illumination source and optics. Format 848x600 Pixel Pitch 17 um Maximum Binary Frame Rate 4065 Hz. Address Mode Snapshot Max. Duty Factor ~97% Amplitude Resolution 1-24 bit programmable. Contrast Ratio ~90:1 MWIR Max Apparent Temperature >800K (Dependent upon source selected) Pixel Operability 100% Spatial Uniformity >99.8% Size 8.5 x9.0 x10.5 Interfaces PC (CRT), DVI, NTSC, S-Video Power Consumption 7W DMD, 50W - System Table 1: Micromirror Array Projector System Performance Summary It should be noted that the maximum apparent temperature is dependent only upon the illumination source and may be increased by increasing the source temperature. Figure 5 shows the apparent temperature of the on and off pixels of a DMD in the 3-5 um band as a function of illumination source temperature. To-date we have illuminated the DMD with source temperatures up to 523 K. At this temperature, the MWIR relative radiance is ~40:1 and the contrast ratio is ~93:1. 200 Apparent Temperature vs. Illumination Source Temperature Apparent Temperature (Deg. C) 150 100 50 OFF Pixels ON Pixels 0 0 50 100 150 200 250 Illumination Source Temperature (Deg. C) Figure 5: Apparent Temperature vs. Illumination Source Temperature

Four example images collected from the prototype IR DMD projector system operating in PWM mode are shown in Figures 6, 7, 8, and 9. The projector was programmed for 6 bits of amplitude resolution in a ~3.0 ms time period. The images were collected with a 320x240 InSb FPA camera operating at 60 Hz and set to an integration time of ~3.0 msec. Figure 6: Sample PWM IR DMD Imagery Figure 7: Sample PWM IR DMD Imagery Figure 8: Sample PWM IR DMD Imagery Figure 9: Sample PWM IR DMD Imagery

5.0 Dynamic Sensor Test Set OSC has developed a second configuration of the DMD-based IR projector called the Dynamic Sensor Test Set (DSTS). This system is designed for automated high speed testing of visible and IR sensors. The DSTS is designed to replace the static target plates and choppers used on industry-standard test collimators. The DSTS is capable of performing standard tests such as MTF, MRTD, and NE T at very high speed, as well as advanced dynamic tests such as seeker tracking and correlation. The DSTS is a dynamic scene projector which can be operated in binary or PWM mode. Applications of the projector include any sensor test application which currently uses static test plates, but needs higher speed or dynamic scene capability. 5.1 DSTS Design The projector consists of a single customized DMD, three illumination sources, relay optics, a standard test collimator, and custom drive electronics. A photograph of the system is shown in Figure 10. The DMD was modified for use in the IR, visible, and UV by replacing the standard window with a BaF 2 window. The DMD has a format of 848x600, and a binary frame rate of 4065 Hz. The system was designed to allow the user to manually select between a visible and IR source. Two broadband IR sources are used for illumination when the system is in IR mode. One source illuminates the mirrors in the on position and typically is set to a temperature higher than ambient. The second IR source illuminates the mirrors in the off position and is typically set to temperatures below ambient. Both blackbody temperatures are controlled via a PC RS-485 interface, and may be controlled in absolute or differential temperature mode. A single quartz halogen source is used to provide illumination in the visible mode. The image of the DMD is relayed to the focal plane of the standard test collimator using an all reflective 1:1 relay system. The resolution of the relay exceeds the resolution of the standard OAP collimator offaxis and is diffraction limited across the entire FOV of the DMD. The use of the relay allows the DSTS to be used with existing collimators without modification. The custom drive electronics were designed to be programmable such that any combination of gray scales, frame rate, and PWM frequencies (within the capabilities of the DMD) can be generated. For generation of standard test patterns such as bar targets, the binary mode is used. If gray scale targets are desired, then the system can be switched to PWM mode and synchronized to the UUT. Figure 10: Dynamic Sensor Test Set

5.2 DSTS Performance Table 2 below summarizes the performance characteristics of the DSTS projector. Parameter Performance Spectral Range Visible to LWIR available. (Switchable sources) Format 848x600 FOV Dependent upon collimator FOV Object Size 14.4x10.2 mm. Pixel Pitch 17 um Maximum Binary Frame Rate 4065 Hz. Address Mode Snapshot Max. Duty Factor ~97% Amplitude Resolution 1-24 bit programmable. Binary and PWM modes selectable Contrast Ratio ~90:1 MWIR MWIR Apparent T Range -10 C to +55 C Pixel Operability 100% Spatial Uniformity >99.8% Size 8.5 x9.5 x16.5 Interfaces PC (CRT), DVI, NTSC, S-Video Power Consumption 7W DMD, 100W - System Table 2: DSTS Performance Summary 7.0 ACKNOWLEDGMENTS This work was sponsored by the US Army Aviation and Missile Command's Research, Development, and Engineering Center under contract DAAH01-00-C-R093. The authors would like to thank Mr. Alex Jolly, Mr. Bill Sholes, Mr. Scottie Mobley, and Mr. Jim Buford, all of USAAMCOM, for their support of our efforts. The authors would also like to thank our colleagues at OSC, Ms. Ivette Dennison, and. Mr. Tracy Reynolds, for their support. 8.0 TRADEMARKS Digital Micromirror Device, DMD, Digital Light Processing, and DLP are registered trademarks of Texas Instruments Incorporated.