LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS



Similar documents
Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

HYDRAULIC ACCUMULATOR. Energy buffering applications APPLICATIONS OSP 035. Applications with short term high quantity oil requirements

Unit 24: Applications of Pneumatics and Hydraulics

Example. Fluid Power. Circuits

Why and How we Use Capacity Control

The Secret of Hydraulic Schematics. BTPHydraulics

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

COUNTERBALANCE VALVES

Hydraulic Accumulators Introduction. Page Accumulator Selection Guide. Design Features and Construction. Charging Valve.

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Troubleshooting PRESENTED BY

SIMPLIFIED VALVE CIRCUIT GUIDE

Pressure Relief and Regulating Valves

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

3. X-REAS (Relative Absorber System)

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

SIMPLIFIED VALVE CIRCUIT GUIDE

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

ACTIVE PARTNER OF CUSTOMERS

PART 2 FORKLIFT HYDRAULIC SYSTEM

GENERAL APPLICATIONS 1 E 01-12

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

C. starting positive displacement pumps with the discharge valve closed.

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Basic Hydraulics and Pneumatics

Class 5 to 7 Truck and Bus Hydraulic Brake System

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

PUMP AND MOTOR DIVISION

Bladder-type accumulator

Water hammering in fire fighting installation

hance the application of specific components, such as pumps, motors, accumulators, filters, and airline lubricators.

V47 Series Temperature Actuated Modulating Water Valves

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

Pressure drop in pipes...

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Flow divider (flow distributor), type TQ

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

Oil and Coolant Circulating Heating System. Model - OCSM

CO MPa (abs) 20 C

Select the Right Relief Valve - Part 1 Saeid Rahimi

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

The Second Law of Thermodynamics

Rexroth Hydraulic Pump A10VO Series User Manual

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

Quiz On Information Learned From Chapter 1

Chapter 5 Shock Absorber Design

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Automatic Back-Flushing Filter AutoFilt RF9.

How Ground/Water Source Heat Pumps Work

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Pressure calibration equipment

15CI and 25CI Reversing Motor Pumpset Owner's Manual

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

Laddomat Charging unit

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Pressure Relief Valves SPV, SPVF

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

Accumulators, Accessories and Spares

SUSPENSION AND STEERING OVERVIEW

Turbocharger System Optimization

BERMAD Fire Protection

Description of functions

Mechanical shaft seal types and sealing systems

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Root & Contributing Causes. Site Answers & Comments: Preventative / Recommended / Accepted Steps of Risk Mitigation, Points of Interest:

Fully Pumped Systems

Grade 8 Science Chapter 9 Notes

Chapter 7 Hydraulic System Troubleshooting

P U L S A T I O N D A M P E N E R S

The Trouble with R407c

Meritor WABCO Hydraulic Power Brake (HPB) System Bleeding Procedures

1. General Advantages of the piston accumulator Main applications Accumulator sizing Accumulator selection 13-14

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Introduction to Process Control Actuators

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Hydraulic control unit series

Name Class Date. F N A cm 2 A cm 2 Unknown: Step 2: Write the equations for Pascal s principle and pressure, force, and area.

The Precharge Calculator

FUEL & FUEL SYSTEM PROPERTIES OF FUEL

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

Chapter 6 Work and Energy

TRAINING, EXAMINATION AND CERTIFICATION

Chapter 19 - Common Rail High Pressure Fuel Injection Systems

KNC Model 3666 Automatic Pressure Calibration System

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Transcription:

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS 1. Define an accumulator and explain its function A hydraulic accumulator is a device that stores the potential energy of an incompressible fluid held under pressure by an external source against some dynamic force. This dynamic force can come from different sources. The stored potential energy in the accumulator is a quick secondary source of fluid power capable of doing useful work. It is a simple hydraulic device which stores energy in the form of fluid pressure. This stored pressure may be suddenly or intermittently released as per the requirement. In the case of a hydraulic lift or hydraulic crane, a large amount of energy is required when the lift or crane is moving upward. This energy is supplied from the hydraulic accumulator. But when the lift is moving in the downward direction, it does not require a huge amount of energy. During this particular time, the oil or hydraulic fluid pumped from the pump is stored in the accumulator for future use. 2. What are the different types of accumulators? There are three basic types of accumulators 1. Weight loaded or gravity accumulators 2. Spring loaded accumulators 3. Gas loaded accumulators 3. Why are accumulators used? To supplement pump flow: The most common use for accumulators is to supplement pump flow. Some circuits require high-volume flow for a short time and then use little or no fluid for an extended period. Generally speaking, when half or more of the machine cycle is not using pump flow, the application is a likely candidate for an accumulator circuit.

4. Explain the principle of operation and possible application of the hydraulic accumulators Like an electrical storage battery, a hydraulic accumulator stores potential power, in this case liquid under pressure, for future conversion into useful work. This work can include operating cylinders and fluid motors, maintaining the required system pressure in case of pump or power failure, and compensating for pressure loss due to leakage. Accumulators can be employed as fluid dispensers and fluid barriers and can provide a shock-absorbing (cushioning) action. Accumulators are used mainly on the lift equipment to provide positive clamping action on the heavy loads when a pump's flow is diverted to lifting or other operations. An accumulator acts as a safety device to prevent a load from being dropped in case of an engine or pump failure or fluid leak. On lifts and other equipment, accumulators absorb shock, which results from a load starting, stopping, or reversal. 5. Define and derive an expression for the volumetric capacity of bladder type accumulators The volumetric capacity of the accumulator is defined as volume of the oil delievered to /from the accumulator at pressure P in operating range P 1 = P=P 2 Adiabatic Isothermal

{( ) ( ) } {( ) ( )} 6. Explain the construction and operation of the piston type accumulator Piston type accumulator: - It consists of a cylinder with a freely floating piston with proper seals. Its operation begins by charging the gas chamber with a gas (nitrogen) under a predetermined pressure. This causes the free sliding piston to move down. Once the accumulator is precharged, hydraulic fluid can be pumped into the hydraulic fluid port. As the fluid enters the accumulator, it causes the piston to slide up, thereby compressing the gas which increases its pressure and this pressure is then applied to hydraulic fluid through the piston. Since the piston is free sliding, the pressure on the gas and the hydraulic fluid is always equal. Piston type accumulator

7. Explain the construction and operation of the bladder type accumulator Bladder accumulator: - These accumulators function in the same way as the other two accumulators. Here the gas and the hydraulic fluid are separated by a synthetic rubber bladder. The bladder is filled with nitrogen until the designed pre-charge pressure is achieved. Hydraulic fluid is then pumped into the accumulator, thereby compressing the gas and increasing the pressure in the accumulator. The port cover is a small piece of metal that protects the bladder from damage as it expands and contacts the fluid port. Figure 6 Bladder type accumulator In an accumulator, at any point of time, we are either compressing a pre-charged gas or allowing it to expand. This compression or expansion brings about a status change in the gas, which is governed by the perfect gas equation, Where P is the absolute pressure in Bar, V is the gas volume in m 3, m is the mass in kg, R is the universal gas constant. (most common gas used in industry is Nitrogen) For the particular gas and the accumulator, the value of WR is constant written as, PV/T = constant or When the change takes place over a long period of time the temperature of the gas remains constant and such a change is called isothermal, resulting in the equation

When the change occurs instantaneously, there is no time for heat transfer from the work to the environment and such a change is called isentropic or reversible adiabatic and is given by, All changes between isothermal and isentropic are called polytropic. Pressure volume diagram shown in the figure 7will help us to understand how the volume variation as a function of pressure is depending on the value of polytropic exponent n which for nitrogen is contained within the limits. The value of n is taken to be equal to 1 if the compression and expansion process takes place under isothermal process. For adiabatic conditions, the value of n is taken equal to 1.4. Isothermal conditions can be considered to exist if the accumulator is used as a volume compensator, leakage compensator and pressure compensator or as a lubrication compensator. In all other cases such as, energy accumulation, pulsation damping, emergency power source, dynamic pressure compensator, shock absorber, hydraulic spring, etc., expansion and compression process may be considered to take place under adiabatic conditions. Generally, adiabatic condition is considered to exist if the compression or expansion period is less than 3 minutes. 8. Explain the construction and operation of diaphragm type accumulator In this type, the hydraulic fluid and nitrogen gas are separated by a synthetic rubber diaphragm. The gas is filled through the gas port under predetermining pressure. The advantage of diaphragm accumulator over piston accumulator is that they have no sliding surface that requires lubrication and can therefore be used with fluids with poor lubricating qualities. They are less sensitive to contamination due to the lack of any close fitting components

9. Discuss in detail the application of hydraulic accumulators as energy storage elements. Draw a hydraulic circuit for this application. 1. Accumulator as an auxiliary power source The purpose of accumulator in this application is to store the oil delivered by the pump during a portion of the work cycle. The accumulator then releases the stored oil on demand to complete the cycle, there by serving as a secondary power source. Figure 8 Accumulator as an auxiliary power source When the four way valve is manually activated oil flows from the accumulator to blank end of cylinder. This extends the piston until it reaches the end of the stroke. When the cylinder is in its fully extended position, the accumulator is being charged. The four way valve is then deactivated for retraction of the cylinder oil flows from both pump and accumulator to retract the cylinder rapidly. 10. Discuss in detail the application of hydraulic accumulator for protection against shocks Accumulator as a hydraulic shock absorber

To system Shut off valve Accumulator as a hydraulic shock absorber One of the important applications of accumulator is the elimination of hydraulic shock. Hydraulic shock is caused by the sudden stoppage or declaration of a hydraulic fluid flowing at relatively high velocity in a pipe line. By rapidly closing a valve creates a compression wave. This compression wave travels at the speed of sound upstream to the end of the pipe and back again to the closed valve, which causes an increase in pressure. The resulting rapid pressure pulsations or high pressure surges may cause damage to the hydraulic system components. If an accumulation is installed near the rapidly closing valve, the pressure pulsations or high pressure surges are suppressed. 11. Discuss in detail the application of hydraulic accumulator in protecting against thermal expansion. When closed loop hydraulic systems are subjected to heat conditions, both the pipe lines and the hydraulic fluid expand volumetrically. Since the coefficient of cubical expansion of most fluid is higher than that for pipe materials, this expanded liquid volume increases the entire system pressure. This condition may cause pressures to exceed the limits of safety, and may damage the system components. Under these conditions, an accumulator of proper capacity precharged to the normal system working pressure is installed. It takes up any increase in the system fluid volume, thus reducing the system pressure to its safe limits. The accumulator also feeds the required volume into the system as thermal contraction takes place.

Figure 12 Accumulator as a Thermal Expansion compensator 12. Discuss in detail the application of hydraulic accumulator for internal leakage compensation and the application of constant pressure Accumulator as a leakage compensator Figure 9 Accumulator as a leakage compensator Accumulator can be used as a compensator for internal and external leakage during an extended period during which the system is pressurized but not in operation. The pump charges the accumulator and the system until the maximum pressure setting on the pressure switch. The contacts on the pressure switch then open to automatically stop the electric motor that derives the pump. The accumulator then supplies leakage oil to the system during a long period.

Finally, when system pressure drops to the minimum pressure setting of the pressure switch, it closes the electrical circuit of the motor until the system has been recharged. The check valve is placed between the pump and accumulator so that the pump will not reverse when the motor is stopped and will not permit all the accumulator charge to drain back into the power unit. With this circuit the only time the power unit operates is when the pressure drops to a unsafe operating level. This saves electric power and reduces the heat in the system. 13.What are the precautions you have to take in using Accumulator Always arrange some method to drain the accumulator at shut down. Never work on a circuit with an accumulator until it is depressurized. Make sure accumulator flow is restricted to a reasonable rate during operation and shut down to avoid damage to the machine or piping. Accumulators will discharge fluid at any rate the exit flow path will allow. Such high flow does not last long, but the damage it causes is done quickly. Always isolate the pump from the accumulator with a check valve so fluid cannot back flow into the pump. Without a check valve, accumulator back flow can drive the pump backward -- and overspeed it to destruction in some instances. Check the accumulator s pre-charge pressure at installation and at least once a day for the first week of operation. If there is no noticeable loss of pressure during this time, do the next check a week later. If all is well then, do a routine check every three to six months thereafter. Whenever the accumulator pre-charge drops below nominal pressure, the volume of available fluid is reduced and finally the cycle slows. 14. List the three method by which we can store enery using accumulator Energy is stored in an accumulator by: Lifting a weight, compressing a spring, Compressing a gas