PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Similar documents
PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

User s Manual Before using the inverter, you need to read and save the safety instructions.

650W Single Output Power Supply

HM-W536 Install Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Advantium 2 Plus Alarm

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

ST Series POWER SUPPLIES USER INSTRUCTIONS

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Model SRMD Setra Remote Monitoring Display

Digital input modules

Charge Regulator SCR 12 Marine

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

DCS Input/Output Relay Card Series

Cross-beam scanning system to detect slim objects. 100 mm in

Manual. Solar Fountain Mobile Phone Charger

Modular I/O System Analog and Digital Interface Modules

Nest Learning Thermostat Installation Guide. Installation step-by-step

Thyristor-controlled power supplies and battery chargers

Power supply unit Model: PAC-SC50KUA

TIG INVERTER INSTRUCTION MANUAL

ADM1TE 5/30A DIN rail single phase two wire energy meter

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Power Supplies 3. SDN-P DIN Rail Series

YSmart Technology Co.,Ltd

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

ACS-30-EU-EMDR-10-MOD

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

How To Use A Power Supply Unit (Upu)

DLP-PU/E Instruction Manual

Adjustment functions for both span and shift have been incorporated

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG


Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

is then retained absolutely without interruption.

BITMAIN. APW PSU Series User Guide

GWS250 Series Instruction Manual

User s Manual AURORA 1.2K/2.2K

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

MIC-WKT and MIC-WKT-IR

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Meaco 30L and Meaco 40L dehumidifier instruction manual

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

BroadBand PowerShield. User Manual

Manual Ranging MultiMeter

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Datasheet. Arrant-Light Oy. 120W DR Series

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

esata External Storage

RY2 miniature industrial relays

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

INSTALLATION MANUAL. AC/DC Power Supply

Telephone- and leased line modem for industrial applications TD-36

Water Leak Detection System

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Manual for Fire Suppression & Methane Detection System

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

16/32 Channel 1U Rack Mount CCTV Power Supply

PK5500 v1.1 Installation Instructions

Battery Power Inverters

TX OPEN RS232/485 module

INSTALLATION INSTRUCTIONS

Redundancy Module QUINT-DIODE/40

Energy Management Energy Meter Type EM23 DIN

User manual Rev. 1.2 (17/04/2015)

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

How To Use A Cdm250 Digital Multimeter

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Single Station Remote Alarm

Remote Alarm Monitoring System

Single Output Switching Power Supply

SYSTEM 4C. C R H Electronics Design

Transcription:

PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014

the 8x 1A/12V DC power output for powering analog cameras output voltage adjustment 12V 15VDC 8 outputs protected with 1A fuses jumper selectable fuses: glass fuse or polymer fuse wide range of supply voltage 176 264VAC high efficiency 83% LED indication Features: FPS technical output of fuse activation indication protections: SCP short-circuit protection OVP over voltage protection surge protection OLP overload protection against tampering warranty 3 year from the production date An example of power supply for analog cameras. range 12V 15V DC, 8 x 1A CONTENTS: 1. Technical description. 1.1 General description 1.2 Block diagram 1.3 Description of PSU components and connectors 1.4 Specifications 2. Installation. 2.1 Requirements 2.2 Installation procedure 3. Operating status indication. 3.1 LED indication 3.2 Technical outputs 4. Operation and use. 4.1 Overload or short circuit at the PSU output 4.2 Activation of the OVP system of the PSU 4.3 Maintenance 2

1. Technical description. 1.1 General description. The stabilized power supply is designed to supply analog cameras or other devices requiring stabilized voltage of 12V DC. The output voltage adjustment range is adjusted via a potentiometer within the range of 12V 15V DC. The PSU features 8 outputs protected independently by either glass fuses or polymer fuse. A failure (a short circuit) in the output circuit makes a fuse blow or an activation of the polymer fuse and disconnection of the circuit from the DC power supply (+U). The PSU is housed in a metallic enclosure with an indication panel featuring a microswitch indicating unwanted opening of the door (faceplate). 1.2. Block diagram. (fig.1). Fig.1. Block diagram of the PSU. 1.3. Description of PSU components and connectors. Table 1. Elements of the PSU pcb (see fig. 2). Element no. Description [1] L1..L8 (green) LEDs (indicating fuse activation) [2] F1 F8 glass fuses in AUX (+) circuits [3] IN supply input of the LB8/AW strip [4] AUX1. AUX8 outputs, COM (-) shared terminal [5] L FPS (red) diode indicating failure of a particular output (fuse activation) [6] FPS output indicating failure of a particular output, OC type (normal status: L, failure: hi-z) Jumper for the selection of the fuse type: Fx Fx.x [7] Fx Fx.x Fx jumper on polymer fuse Fx.x jumper off glass fuse 3

Table 2. Elements of the PSU (see fig. 3). Element no. Fig. 2. The view of the PSU s pcb. Description [1] L-N 230V AC power connectors, PE protection connector [2] LED indication of DC power status, main module of the PSU [3] PSU module [4] V ADJ, potentiometer, output voltage adjustment within the range of 12V 15V DC [5] LB8/AW fuse strip, with power outputs and LED indication [6] Tamper, contact of tampering protection (NC) Fig.3. The view of the PSU. 4

1.4. Specifications: - electrical specifications (tab.3) - mechanical specifications (tab.4) - operation safety (tab.5) - operating specifications (tab.6) Electrical specifications (tab. 3). Supply voltage 176 264V AC Current consumption 0,9A@230VAC max. PSU power 120W max. Efficiency 83% Output voltage 12V DC Output current 8 x 1A Output voltage adjustment range 12V 15VDC Ripple voltage 100mV p-p max. LB8/AW STRIP Short-circuit protection SCP 8x F 1A fuse or PTC 1A PSU MODULE 105% 150% of PSU power, electronic current limiting Overload protection OLP 105% 150% of PSU power, electronic current limiting Surge protection varistors Surge over voltage protection OVP >16V (activation requires disconnecting the load or supply for about 20 s.) Tampering protection system - TAMPER indicating unwanted - microswitch, NC contacts (enclosure closed), 0,5A@50V DC (max.) opening of the PSU s enclosure Technical outputs: - OC type, 50mA max, - FPS outputs indicating fuse failure normal status: L level (0V), (blow) of LB8/AW strips: (SCP activation) failure: hi-z level F1 F8 fuses F 1A/250V or PTC 1A (manual selection) Mechanical specifications (tab. 4). Enclosure dimensions 280 x 256 x 60+8 (WxHxD) [mm] (+/- 2) Fixing See figure 3 Net/gross weight 1,96/2,25 kg Enclosure Steel plate, DC01 0,7mm colour: RAL 9003 Closing Cheese-head screw: at the front Connectors Power supply: 230V AC: Φ0,63-2,05 (AWG 22-12) AUX outputs: Φ0,51-2,05 (AWG 24-12) LB8/AW: Φ0,51-2,05 (AWG 24-12) TAMPER output: wires 25cm Notes The enclosure does not adjoin the assembly surface so that cables can be led. Convectional cooling. Operation safety (tab.5). Protection class PN-EN 60950-1:2007 I (first) Protection grade PN-EN 60529: 2002 (U) IP20 Electrical strength of insulation: - between input (network) circuit and output circuits of the PSU (I/P-O/P) 3000V/AC min. - between input circuit and PE protection circuit (I/P-FG) 1500V/AC min. - between output circuit and PE protection circuit (O/P-FG) 500V/AC min. Insulation resistance: - between input circuit and output or protection circuit 100 MΩ, 500V/DC Operating specifications (tab.6). Operating temperature Storage temperature Relative humidity Vibrations during operation Impulse waves during operation Direct insolation Vibrations and impulse waves during transport -10ºC...+50ºC -25ºC...+60ºC 20%...90%, without condensation unacceptable unacceptable unacceptable PN-83/T-42106 5

2. Installation. 2.1 Requirements. The stabilized PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC interference and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative humidity (RH=90% maximum, without condensation) and temperature from -10 C to +50 C. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the enclosure. During normal operation the total current consumption of the receivers cannot exceed I=8x1A As the PSU module is designed for a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about the method of unplugging (most frequently through separating and assigning an appropriate fuse in the fuse-box). The electrical system shall follow valid standards and regulations. 2.2 Installation procedure. 1. Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 2. Mount the PSU in a selected location and connect the wires. 3. Connect the power cables (~230VAC) to L-N terminals of the PSU. Connect the ground wire to the terminal marked by the earth symbol. Use a three-core cable (with a yellow and green PE protection wire ) to make the connection. Lead the cables to the appropriate terminals of the connection board through the bushing. The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with the earth symbol in the PSU enclosure. Operation of the power supply without a properly made and fully operational shock protection circuit is UNACCEPTABLE! It can result in device damage or an electric shock. 4. Connect the receivers cables to the AUX1 AUX8 connectors on the LB8/AW ) strips. 5. If necessary, connect the device s wires (of an alarm panel, controller, indicator, etc.) to the technical outputs: - FPS (LB8/AW ) output indicating a fuse failure (outputs of the LB8/AW fuse strips). - TAMPER output indicating unwanted opening of the PSU s enclosure. 6. In electrical installations with significant voltage drops in the resistance of the wires that lead to the receivers, the voltage value can be corrected with the P1 potentiometer (12V 15V DC). 7. Check the PSU operating status indication 8. Once the installation and operation control have been completed, the enclosure can be locked. 3. Operating status indication. The PSU is equipped with LED indication of operation status. The presence of power at the outputs of the PSU is indicated by the illumination of green LEDs on the front panel of the device. L FPS red LED [!] indicates a failure. The status of the PSU can be remote controlled by the FPS technical output. 3.1. LED indication (fig.4.). LED1 LED8 green diodes indicate power at the outputs: LB8AUX1..AUX8. In case of a power loss at the output (fuse activation), an appropriate diode goes out. (L1 for AUX1, L2 for AUX2 etc.) L FPS red LED [!] indicates a failure of at least one AUX output (the output s number is indicated by the green diode). 6

Fig. 4 The view of the PSU panel. 3.2 Technical outputs. The PSU has indication outputs that allow transferring information about a failure or tampering. FPS - output indicating a fuse failure (outputs of the LB8/AW fuse strip). The FPS technical output during correct operation of the PSU is connected to ground (GND). Failure of one of the fuses opens the output high impedance state. The failure is also indicated by the L FPS red diode. Fig. 5. Electrical diagram of the OC output. TAMPER output indicating unwanted opening of the PSU, contains volt-free (potential-free) contacts indicating the door status - unit closed: NC, unit opened: NO. 4. Operation and use. 4.1 Overload or short circuit at the PSU output. The AUX1 AUX8 PSU outputs of the LB8/AW strips are protected against a short circuit by glass fuses or polymer fuses. If a fuse-assisted protection has been chosen, replace the fuse (of the same parameters) in case of a failure. If the polymer fuses-assisted protection has been chosen, there will be an automatic disconnection of the output voltage indicated by the green diode going out. Then, cut off the load from the PSU output for approx. 1 minute. 4.2. Activation of the OVP system of the PSU. When the OVP system is activated, the output voltage is automatically cut off. Restart is possible after disconnecting the PSU from the mains supply 230V for at least 20 seconds. 4.3. Maintenance. Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network. The PSU does not require performing any specific maintenance measures. However, in case of significant dust level, clean its interior with compressed air. In case of a fuse exchange, use the replacement of the same parameters. 7

WEEE MARKING According to the EU WEE Directive It is required not to dispose of electric or electronic waste as unsorted municipal waste and to collect such WEEE separately. GENERAL WARRANTY CONDITIONS 1. Pulsar (the manufacturer) grants a three-year warranty for the equipment, counted from the device s production date. 2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the manufacturer s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such defects have been reported within the warranty period (item 1). 3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the manufacturer. 4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect. 5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, however not later that within 14 days from the delivery to the service centre of the manufacturer. 6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively. 8. The warranty does not cover the defects of the equipment, resulting from: - reasons beyond the manufacturer's control, - mechanical damage, - improper storage and transport, - use that violates the operation manual or equipment s intended use - fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents, - improper installation and configuration (in defiance with the manual), 9. The warranty is void in any of the following circumstances: - construction changes - repairs carried out by any unauthorized service center - damage or removal of warranty labels - modifications of the serial number 10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the wholesale prices suggested by the manufacturer on the day of purchase. 11. The manufacturer takes no responsibility for the defects that result from: - the damaging, malfunctioning or inability to operate the equipment - defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the recommendations and requirements contained in the manual, or the use of the equipment. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl 8