FIRE PROTECTION AT CONSTRUCTION SITE



Similar documents
Fire Safety Risk Assessment Checklist for Residential Care Premises

Fire Safety Requirements for Child Care Centre

Bastille Court 2 Paris Garden London SE1 8ND Telephone: Fax: training@thefpa.co.uk Web:

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

Summary of Preliminary Assessment on Structural, Fire and Electrical Safety

FIRE DETECTION AND ALARM SYSTEMS

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

Spray Booth Guideline

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

FLA S FIRE SAFETY INITIATIVE

FIRE SAFETY FOR OFFICE WORKERS

FIRE RISK ASSESSMENT

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Fire Safety Log Book

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK

Flammable Liquids Storage

FIRE PREVENTION PLAN

Texas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08)

Decree of the Ministry of the Environment. on fire safety of garages

Fire Protection Notice No. 9 ELECTRICAL SAFETY

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment

FIRE RISK ASSESSMENT. The Workplace Fire Precautions Legislation

XXX SCHOOL Risk Assessment Form

Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24

Greater Manchester Fire and Rescue Service

Flammable Liquids Storage

Electrical Safety Tips. Help us keep you safe

RESIDENTS FIRE SAFETY INFORMATION PACK

FIRE-FIGHTING DESIGN BRIEF REPORT

How To Write A Fire Risk Assessment

Installation Instructions for Alarm Module Kit A043F059

COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE)

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

SunMaxx Solar Filling Station Operating Instructions

How to carry out a risk assessment and create a safety statement

FIRE SAFETY REGISTER. Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service

SL280UHV SERIES GAS FURNACE WARNING

Magnetic Starter - 30A, 120/240V Coils

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Brief Analysis of Site Accident Cases

ADM1TE 5/30A DIN rail single phase two wire energy meter

LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

HEALTH AND SAFETY REDUCING ACCIDENTS IN KITCHENS

SECTION CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Ducoterra Radiant Heating Panel Installation Manual

Course of Construction Questionnaire

Fire Policy and Procedures. Cañada Blanch Spanish School

FIRE RISK ASSESSMENT

Fire Safety In High Rise Building

Fire Safety Log Book. Premises Name: Premises Address: Date From: Date To: Location of Log Book:

St. John s University

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Fire Alarm system Installation Guide

FIRE SAFETY ONLINE TRAINING

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

EVALUATION OF THE PERFORMANCE OF FIRE DETECTION SYSTEM IN AN INSTITUTIONAL BUILDING

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO USE

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

Achat 115MA full-range speaker. user manual

Guidance on the use of Marquees, Tents and other Temporary Structures

STANDARD SITE LICENCE CONDITIONS FOR RESIDENTIAL PARK HOME SITES IN GUILDFORD CARAVAN SITES AND CONTROL OF DEVELOPMENT ACT 1960 (AS AMENDED)

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

15GAL STEEL OIL DRAIN WITH 110V PUMP

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

Civil Engineering Sector Labour-Management Health and Safety Committee

Sample Written Program. For. Flammable Liquids

Notes. Material 1. Appropriate Flammable Liquids

COMMERCIAL GAS DRYER FUELLED BY LIQUEFIED PETROLEUM GAS CODE OF PRACTICE GU13 (MODULE TWO)

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Safety and Health Office WORKPLACE SAFETY CHECKLIST

Electric Instantaneous. Water Heaters. Service manual

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Lee Baron FIRE RISK ASSESSMENT

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

exit routes and fire protection

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

OSHA Office of Training and Education 1

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

STONEBRIDGE COMMUNITY FUNDAY

PREPIPED LIQUID FUEL MANIFOLDS PLPM

Fire Risk Assessment Safety Checklist

This Guidance Notes is prepared by the Occupational Safety and Health Branch, Labour Department. This edition July 2004

Transcription:

FIRE PROTECTION NOTICE N0.13 FIRE PROTECTION AT CONSTRUCTION SITE Serious fires have occurred in buildings under construction which will not only delay their completion dates but also result in serious monetary losses, as the whole complete structure may need to be partly/wholly demolished and rebuilt. The worst could bring about injuries and deaths. The major causes for fire in these buildings are:- (i) (ii) (iii) (iv) (v) (vi) (vii) Accumulation of loosely packed and/or scattered building materials which are usually highly combustible; inadequate insulation/protection and/or overloading to electric wiring; carelessness in welding work; lacking of safety measures and supervision for control burning of rubbish; smoking and carelessness in the disposal of smoking materials; improper use and storage of dangerous goods; and the lack of fire protection system due to the non-completion of fire service installations and/or improper maintenance. To mitigate the fire risk and minimize the possibility of the outbreak of fires at construction sites, the following guidelines should be observed by building contractors and site workers: 1. Storage of Combustible Materials Combustible materials stored on site, whether outside or inside a structure, should be well stacked in an orderly manner and to the minimum. Ample separating spaces should be provided to each stack both from the top and the sides. 2. Storage of Dangerous Goods All dangerous goods shall be stored in appropriate Dangerous Goods Stores approved by the Director of Fire Services. Unused dangerous goods should be returned to and stored at Dangerous Goods Stores. Safety precautions on the use of dangerous goods should be observed at all times. 3. Housekeeping Good housekeeping will reduce the chances of a fire, rate of fire spread as well as injuries/fatalities. Things to observe include:- (i) (ii) (iii) orderly storage of materials; periodical removal of discarded combustible packing materials, wood chips, saw dust, etc.; and an unobstructed exit route should always be maintained. Page 1

4. Provision of Access Substantial staircase(s) should be erected corresponding with the building of floor slabs to ensure the availability of escape route and access for fire fighting purpose. Such staircase(s) should be maintained free from obstruction. 5. Open Flame Work Sparks from open flame work (welding, cutting, etc.) is, by large, the most common cause for fires in buildings under construction. Extreme care should therefore be exercised when carrying out any welding work. All combustible materials should be removed, where possible, from the immediate vicinity. A portable fire extinguisher should be placed at immediate readiness. 6. Coating and Sealing Substances Special caution is required in heating and boiling of the coating and sealing substances which are used as insulation and sealing materials. 7. No Smoking Instruction No Smoking signs should be prominently displayed and strictly observed in the construction are as especially where highly inflammable adhesives or solvents are used. 8. Electric Wiring All electric wiring should be properly insulated and protected. Earth leakage circuit breakers should be installed to trip the supply when overloading of the circuit occurs. 9. FIRE SERVICE INSTALLATIONS AND EQUIPMENT In order to maintain proper fire protection for construction site, it has been agreed by The Hong Kong Construction Association Limited that the following minimum fire service installations and equipment have to be provided during building construction:- A. FIXED FIRE PUMP i. Fixed fire pump(s)shall be provided to relay water supply for all floors above 30m. Local fire stations should be approached for advice on details of such provision as and when the construction of the building is approaching a height of 30m. i iv. The pump set shall be located close to staircase but shall not cause any obstruction to means of escape. Each pump shall be fitted with inlet/outlet of standard 65mm instantaneous coupling conforming to BS336. The inlet/outlet shall be individually controlled by a wheel-operated screw valve designed to open by counter-clockwise rotation. The direction of opening of the valve shall be clearly engraved in both English and Chinese on the wheel. The pump shall be provided with an air-relief valve. v. The pump set shall be able to produce a flow of not less than 900L/min at a running pressure of not less than 350kPa but not more than 850 kpa at the fire hydrant outlet. vi. A plan showing the location(s) of the fixed fire pump(s) shall be provided at a Page 2

v prominent position at the entrance of the construction site. Directional signs indicating the access to the fixed fire pump(s) shall be displayed at prominent position immediate outside the ground level entrance of the staircase(s) and at suitable intervals. B. ELECTRICITY SUPPLY TO FIXED FIRE PUMP i. Each fixed fire pump shall be connected to the main electricity supply of the construction site. i iv. The electricity supply shall have enough capacity to cater for the simultaneous operation of all fixed fire pump(s) installed in each building under construction. The power cables shall be properly fixed on wall. Each pump shall be provided with duplicated power cables separately routed to avoid complete power failure resulted from mechanical damage. It is preferably that metal conduit or trunking is provided to protect the cables and in such case separate routing will not be required. The duplicated power cables shall comprise a cable connected from electricity mains and the other teed off before the main switch. They shall be terminated at an automatic changeover switch installed next to each fixed fire pump. The pump power supply shall be automatically switched to the secondary power if the normal power fails for whatever reason. v. Schematic diagrams showing the typical arrangements of electricity supply are shown in Figures 1 and 2. C. PORTABLE EQUIPMENT i. A 9-litre water/co 2 portable fire extinguisher shall be provided for each 200 square metres of floor area having been constructed and each floor shall have not less than two fire extinguishers. i The extinguisher shall be located close to staircase. A 9-litre water/co 2 portable fire extinguisher shall also be provided in each site office. 10. Maintenance of Fire Service Installations and Equipment 10.1 The building contractor shall maintain all fire service installations and equipment in efficient working order at all times. 10.2 The fixed fire pump and portable equipment should not be removed unless the building fire hydrant/hose reel installation has been satisfactorily installed. Local fire station should be informed accordingly. 11. ENQURIES Should there be any enquiries on the fire protection measures for construction site, please contact the local fire stations or Fire Protection Bureau at telephone no. 2733 7574. Page 3

FIXED FIRE PUMP FOR UPPER ZONE C / O FIXED FIRE PUMP FOR LOWER ZONE Power cable in separate routing or metal conduit /trunking C / O Non-essential switch board Essential switch board Power Meter Legend: From Power Company - Switch - Switchfuse Figure 1: Schematic Diagram of the Electricity Supply for Fixed Fire Pumps (Single Tower) Page 4

FIXED FIRE PUMP FIXED FIRE PUMP Power cable in separate routing or metal conduit/ trunking C / O C / O Sub-main Distribution Board Sub-main Distribution Board G/F TOWER 1 TOWER 2 Power Cable in separate routing Non-essential switch board Essential switch board Power Meter Legend: From Power Company - Switch - Switchfuse Figure 2: Schematic Diagram of the Electricity Supply for Fixed Fire Pumps (Multiple Towers) Page 5