Boundary-breaking acoustic focusing cytometry



Similar documents
flow cytometry reinvented

Introduction to flow cytometry

FlowSight. Flow cytometry with vision

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

CyAn : 11 Parameter Desktop Flow Cytometer

Immunophenotyping peripheral blood cells

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Standard Operating Procedure

Introduction to Flow Cytometry

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

These particles have something in common

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

APPLICATION INFORMATION

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Cell Cycle Tutorial. Contents

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Below is a list of things you should be aware of before you schedule your sort.

BD FACSComp Software Tutorial

COMPENSATION MIT Flow Cytometry Core Facility

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

Principles of Flowcytometry

ArC Amine Reactive Compensation Bead Kit

HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

How to operate the BD FACSCanto flow cytometer

Three Rules for Compensation Controls

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Introduction to Flow Cytometry

CyFlow Space Your flexible flow cytometer

Standardization, Calibration and Quality Control

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Easy to use. Compact. Flexible. Sorting Chip

LIVE/DEAD Fixable Dead Cell Stain Kits

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

Fluorescence Compensation. Jennifer Wilshire, PhD

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Cytell Cell Imaging System

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

INSIDE THE BLACK BOX

Science is hard. Flow cytometry should be easy.

Uses of Flow Cytometry

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

EdU Flow Cytometry Kit. User Manual

MACSQuantify Software guide. Basics of flow cytometric analysis and software guide. Version 1 EN Original instructions

Compensation in Flow Cytometry

Islet Viability Assessment by Single Cell Flow Cytometry

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

Notes on titering antibodies

Attune NxT Acoustic Focusing Cytometer

Zecotek S Light Projection Network Marketing


Introduction to Flow Cytometry:

Cytometry without limits

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

use. 3,5 Apoptosis Viability Titration Assays

UCHC Guide to FACS DiVa. LSR II instruments

Annexin V Conjugates for Apoptosis Detection

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations

Cell Viability Measurement

Recognition of T cell epitopes (Abbas Chapter 6)

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Attune Acoustic Focusing Cytometer

Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

Annexin V-EGFP Apoptosis Detection Kit

FACS Laboratory. BD LSRs Operator Training. Training Guide.

Attune Acoustic Focusing Cytometer. Training Guide

Absolute counting using flow cytometry. Bright Count Microspheres

GETTING STARTED. 6. Click the New Specimen icon.

Let the BD FACSAria II accompany your best performance ever

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Chapter 6. Antigen-Antibody Properties 10/3/2012. Antigen-Antibody Interactions: Principles and Applications. Precipitin reactions

Welcome to More Choice BD Analyte Specific Reagent (ASR) Catalog

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Flow cytometry basics fluidics, optics, electronics...

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry

Compensation: An Instrumental Perspective

Flow Cytometry. flow cytometer DNA apoptosis ph

Cell Cycle Phase Determination Kit

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

EDF Extended Depth of Field

Transcription:

Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab

One of the main projects in my laboratory is focused on the description and functional analysis of an emerging innate lymphoid cell type. These cells are extremely rare both in blood and in tissues. For flow cytometry analysis we use the Attune Acoustic Focusing Cytometer. The high sample rates of the Attune cytometer allow me to reduce centrifugation steps so that we retain more cells and more rapidly detect rare events. We could not have performed these studies with any other instrument. Prof. David Cousins University of Leicester

MHCII Pacific Blue CD8 Alexa Fluor 7 CD8 Alexa Fluor 7 CD25 APC B22 Pacific Orange Counts Rapid, accurate detection of rare events The Attune NxT Acoustic Focusing Cytometer is a benchtop analyzer that uses a revolutionary technology, acoustic focusing, to align cells prior to interrogation with a laser for your multicolor flow cytometry analysis. The system offers: Unique modular design one-day field upgradable system with configurations from 1 4 lasers, with the ability to detect up to 14 colors Fast detection speed short acquisition time without loss of data quality enables unique applications such as rare event detection and use of no-wash/no-lyse techniques Distinctive acquisition and analysis software intuitive and powerful for users of all experience levels Convenient size complete setup fits on even small benchtop space Multicolor analysis in a modular design With the option to be configured with up to 4 lasers and 14 colors for multiparameter analysis (Figure 1, the Attune NxT Acoustic Focusing Cytometer was designed as a modular system to fit most experimental design needs and lab budgets. The Attune NxT cytometer can be designed to accommodate the most common fluorophores and fluorescent proteins used in flow cytometry to match the panels you are currently running (Table 1. Multiple fluorescent proteins can be detected with an optional 561 nm laser (Figure 2. Whether you configure your system now or upgrade later, the Attune NxT Acoustic Focusing Cytometer can grow with you and your research needs. A 1, B 1 C 5 Side scatter 75 5 25 25 5 75 1, Forward scatter 1 5 CD45.2 APC-Cy 7 1 5 1 6 CD PerCP-Cy 5.5 1 D 6 E F G 1 5 1 5 1 5 1 5 1 5 CD11c PE-Cy 7 1 5 1 6 CD11b FITC 1 5 CD4 Pacific Green 1 2 1 1 1 1 5 Foxp PE Figure 1. Multiparameter (1-color analysis of murine regulatory T cells and dendritic cells with the Attune NxT Acoustic Focusing Cytometer. Lymphocytes were gated using FSC/SSC parameters (A, left and B22-expressing B cells were omitted from subsequent analysis (A, middle. Within the B22, CD45.2 + gate, T cells were analyzed based on their expression of CD (A, right. CD + T cells were separated into two populations based on expression of the co-receptors CD4 or CD8 (B, left. Within the CD4 + T cells there is a subpopulation of suppressive regulatory T cells that express the transcription factor Foxp and the cell surface marker CD25 (IL-2Rα (B, right. CD cells were separated to show a rare population of CD11c + MHCII +, professional antigen-presenting dendritic cells (C, left. Splenic dendritic cells can be subdivided further into CD11b + and CD8 + dendritic cell subsets (C, right, each possessing unique antigen presentation properties.

Superior reliability and maximum signal efficiency The novel design of the optical path helps ensure precise fixed alignment of four spatially separated lasers onto the sample stream enabling consistency in data over time, superior performance, and superior reliability. The instrument can be configured with up to 4 solid-state lasers (45 nm, 488 nm, 561 nm, and 67 nm with flat top beam profiles to minimize the effects of changes in fluidics or optics, which cause instability and alignment issues leading to instrument downtime. The light emitted from cells in the flow cell is transported with high efficiency to the detection optics through fiber-optic cables with minimal loss of signal. The filters in front of the photomultiplier tubes collect light signals and can be easily interchanged and customized to minimize reagent crosstalk and maximize signals (Figure. What is acoustic focusing? The Attune NxT Acoustic Focusing Cytometer uses ultrasonic waves (over 2 MHz, similar to those used in CellLight Nucleus-GFP, BacMam 2. 1 5 1 2 1 2 1 5 CellLight Plasma Membrane-RFP, BacMam 2. Figure 2. Live-cell fluorescent protein detection. U2OS cells were simultaneously transduced with Cellight Nucleus-GFP (Cat. No. C162 and CellLight Plasma Membrane-RFP (Cat. No. C168. Cells were analyzed on the Attune NxT Acoustic Focusing Cytometer using a 488 nm laser and 5/ emission filter along with a 561 nm laser and 585/16 nm emission filter. Table 1. Attune NxT Acoustic Focusing Cytometer fluorophore selection guide. Laser Excitation Emission Common dye Fluorescent protein Violet Blue Yellow Red 45 nm 488 nm 561 nm 67 nm 44/5 Pacific Blue TM ECFP 512/25 Pacific Green TM 6/48 Pacific Orange TM 71/5 Qdot 75 488/1 FSC 488/1 SSC*** 5/ FITC EGFP, Emerald GFP 574/26* Propidium iodide EYFP 59/4** Propidium iodide Fluorescent proteins 695/4 PerCP-Cy 5.5 78/6 PE-Cy 7, Qdot 8 EYFP 585/16 PE RFP 62/15 PE-Texas Red mcherry, dtomato, DsRed, mstrawberry 695/4 PE-Cy 5.5 78/6 PE-Cy 7 67/14 APC 72/ Alexa Fluor 7 78/6 APC-Alexa Fluor 75 *Without a yellow laser present **With a yellow laser present ***Side scatter can be detected by any laser line (default is blue laser. Violet side scatter is recommended for no-wash/no-lyse applications.

A. Acoustic focusing = better precision Acoustically focused sample stream Laser (cross-section device Figure. Example filter configuration for the Attune NxT Acoustic Focusing Cytometer. Filters are easily interchanged to create customized configurations to meet your experimental needs. medical imaging, rather than hydrodynamic forces, to position cells into a single, focused line along the central axis of a capillary (Figure 4. Acoustic focusing is largely independent of the sample input rate, enabling cells to be tightly focused at the point of laser interrogation regardless of the sample-to- ratio (Figure 5. This, in turn, allows the collection of more photons for high-precision analysis at superior volumetric sample throughput. The Attune NxT cytometer accomplishes this without high-velocity or high-volumetric fluid, which can damage cells. In addition, volumetric syringe pumps enable absolute cell counting without beads minimizing cost and sample preparation time. In contrast, cytometers that use hydrodynamic focusing maintain the same sample speed at all flow rates, causing cells to lose focus as the sample core widens to increase flow rate. B. Traditional hydrodynamic focusing: compromised data quality Hydrodynamic core Laser (cross-section Figure 5. Acoustic focusing vs. traditional hydrodynamic focusing as particles pass through the laser. (A In acoustic focusing, cells remain in tight alignment even at higher sample rates, resulting in less signal variation and improved data quality. (B In traditional hydrodynamic focusing, increasing the sample rate results in widening of the sample core stream, resulting in increased signal variation and compromised data quality. Dilute your samples, not your data quality Washing and lysis of red blood cells (RBCs can cause significant cell loss and damage. Significantly higher sample collection rates allow the Attune NxT cytometer to deliver a no-wash/no-lyse protocol to minimize cell loss and simplify sample preparation (Figure 6. This feature is particularly useful for samples that are inherently low in concentration. Dilute samples like cerebrospinal fluid (CSF, stem cells, and any sample with low cell numbers can take a long time to acquire. With the Attune NxT cytometer, even dilute samples can be acquired quickly and without compromising data. Difficult-to-collect samples like Figure 4. Acoustic focusing in action. Fluorescent microspheres were applied to the capillary system of an acoustic focusing cytometer. Beads flow through randomly without any acoustic focusing (left. With the acoustic focusing, the beads are focused into a single line (right.

Gated on on live live CD19 CD19 cells at collection rate cells of 5 at μl/min collection rate of 5 ul/min Figure 6. Eliminate sample preparation without compromising data quality. Five microliters of whole blood was stained with antibodies, incubated, and diluted using 4 ml of buffer and analyzed on the Attune NxT cytometer. 45 nm light is readily absorbed by red blood cells and enables use of the differential side scatter gating shown in the middle panel in which a 45 nm vs. 488 nm side scatter dual parameter plot is used to differentiate the leukocyte and red blood cell populations. From this gated population, a daughter plot of forward and side scatter can be used to identify lymphocyte, monocyte, and granulocyte populations without the need for a fluorescent label. mouse blood and bone marrow, thin-needle aspirates, or any sample with low cell yield can be stained and then diluted without washing or performing RBC lysis. High sample collection rates make acquisition possible you can run up to 4 ml in just 4 minutes. Sample loss is minimized in sample preparation, and full panel testing is possible for all precious samples. Rapid detection of rare events Analysis of rare cell populations requires the collection of high numbers of events in order to attain a reliable measure of accuracy, leading to long acquisition times. The Attune NxT Acoustic Focusing Cytometer achieves sample throughput at rates over 1 times faster than other cytometers up to 1, μl/min and 2 x 1 7 events per run, enabling rapid detection of rare events with reliable accuracy and without aborting data (Figure 7. Precision and sensitivity at all sample rates The Attune NxT Acoustic Focusing Cytometer enables high sensitivity when you need it most. You will be able to maintain precise alignment, even at high sample rates of up to 1, μl/min. The precise alignment provided by acoustic focusing enables researchers to obtain tighter CVs to better distinguish between dim signals and background, resulting in less variation and better signal separation (Figure 8. CD45R/B22-PE fluorescence 1 6 1 5 1 2 1 2 1 5 1 6 CD17-Alexa Fluor 488 fluorescence Figure 7. Collection of more than 1 million live cells and detection of a rare population (.2% of dendritic cells. Plasmacytoid dendritic cells (pdcs are a specialized cell population that produces large amounts of type I interferons in response to viruses and are identified using the immunophenotype CD19 /B22high/CD17 +. Four-color staining of mouse splenocytes included CD19-Pacific Blue, CD17-Alexa Fluor 488, CD45R/B22-PE direct conjugates, and SYTOX AADvanced Dead Cell Stain. A gate was made on live cells using SYTOX AADvanced Dead Cell Stain, followed by gating on CD19 cells. A two-parameter plot of CD45R/B22 vs. CD17 was used to identify pdcs. A collection rate of 5 μl/min was used to acquire 1. million total cells with a cell concentration of 7.5 x 1 7 cells/ml. Plasmacytoid dendritic cells were identified as dual B22 + /CD17 + (upper right quadrant and constitute.851% of live CD19 cells, which is.194% of total splenocytes. Minimal data variation Cell cycle analysis is just one example of where it is critical to precisely detect differences in fluorescence intensity between multiple cell populations. With the Attune NxT Acoustic Focusing Cytometer, minimal variation in results is seen regardless of sample throughput rate. You no longer need to sacrifice throughput for sensitivity (Figure 9. Software that performs to your specifications Attune NxT software is designed to provide powerful data acquisition and analysis using an intuitive, userfriendly interface (Figure 1. Experiments can easily be set up, customized, and saved for future studies. Compensation is automated and can be set up using a guide.

The software is designed to maximize efficiency in performing data analysis, with fast refresh rates for large data sets (up to 2 million events per sample with the ability to immediately visualize changes on data plots as you make adjustments. The software has unique tools to simplify experimental setup, including reagent selection using the filter configuration manager. This provides guidance for matching the right reagent to the optimized channel on the instrument by selecting reagents from a drop-down menu of prepopulated or customized reagents, which is then applied to plot labels. 241 12.5 μ μl/min 25 5 (x 1 25 μ μl/min 264 292 μ μl/min 25 5 (x 1 5 μ μl/min 4 A B 25 5 (x 1 25 5 (x 1 4 μ μl/min 1, μ μl/min 11 12 1 14 15 Conventional flow cytometer (Highest sensitivity = ~12.5 μl/min 12 1 14 15 16 Attune NxT cytometer (12.5 μl/min 25 5 (x 1 25 5 (x 1 869 75 5 C Sample rate (μl/min 12.5 25 5 1, G 1 CV% 2.99. 2.76 2.94 2.7 2.96 G 2 /G 1 1.99 1.99 1.99 2.5 2.5 2. 25 12 1 14 15 16 Attune NxT cytometer (5 μl/min Figure 8. Sensitivity measurements across flow rates. Fluorescent microspheres (Spherotech Rainbow Calibration Particles,.2 μm were run on (A a high-end conventional flow cytometer and (B, C on the Attune NxT Acoustic Focusing Cytometer using a 561 nm laser and (A 61/2 or (B, C 61/15 emission filters. The conventional cytometer was run using the highest sensitivity setting (~12.5 μl/min. The Attune NxT cytometer was run at (B 12.5 μl/min, which is equivalent to the traditional flow cytometer and at (C 5 μl/min, which is 4x more sample. The Attune NxT cytometer showed equal or better results even at the highest flow rates. Figure 9. Minimal data variation at high sample rates with the Attune NxT Acoustic Focusing Cytometer. Jurkat cells were fixed and stained with propidium iodide, treated with RNase, and analyzed at a concentration of 1 x 1 6 cells/ml on the Attune NxT Acoustic Focusing Cytometer at different sample rates. The left peak in all graphs reflects cells in G /G 1 phase, while the right peak reflects cells in G 2 /M phase. Regardless of sample rate, the width of the G /G 1 and G 2 /M peaks and CV% remains consistent for the Attune NxT cytometer, even at the highest sample rate of 1, μl/min. Figure 1. The Attune NxT software interface.

Service and support The Attune NxT Acoustic Focusing Cytometer is backed by our worldwide technical support and service programs. We are focused on delivering personalized service from the time our sales representative walks through the door throughout the life of your Attune NxT instrument. The Attune NxT cytometer is fully supported for one year with our extensive service plan, which includes: Comprehensive training (2 users per instrument Application and assay support Worldwide technical service Preventive maintenance Ordering information Attune NxT Acoustic Focusing Cytometer Lasers Laser color Parameters Cat. No. 4 Blue, red, yellow, violet 16 A24858 Blue, violet, yellow 1 A24859 Blue, red, violet 1 A2486 2 Blue, yellow 9 A24861 2 Blue, violet 1 A24862 2 Blue, red 9 A2486 1 Blue 6 A24864 MMC M727 LuBioScience GmbH Töpferstrasse 5 6 Lucerne 6 T: 41 417 2 8 F: 41 417 2 89 E: info@lubio.ch www.lubio.ch