Model 1756 Test Lead Kit

Similar documents
Series 2220 Multichannel Programmable DC Power Supplies

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Installation Instructions for Alarm Module Kit A043F059

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

aseries A13B Mini Bullet Camera User Manual

Model UT33A: OPERATING MANUAL Table of Contents (1)

AGILENT E5071C ENA NETWORK ANALYZER

HP UPS R1500 Generation 3

MEGGER Insulation & Low Resistance Tester

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

3 WATT LED SPOTLIGHT Model No. SLM

Installation Instructions

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Seven function digital multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

i410/i1010 AC/DC Current Clamp

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

UT202A Operating Manual. Contents

INSTRUCTION MANUAL MODEL PCD-88


Dielectric Withstand Testing in a Production Environment

Manual Ranging MultiMeter

Series 3700A System Switch/Multimeter

MIC-WKT and MIC-WKT-IR

Model UT201/202: OPERATING MANUAL. Table of Contents

Installation and safety instructions for AC/DC built-in devices

User's Guide. True RMS Industrial Multimeter

ADM1TE 5/30A DIN rail single phase two wire energy meter

Model 6220 DC Current Source Model 6221 AC and DC Current Source

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

7 FUNCTION DIGITAL MULTIMETER

Cable Tester Pro ORDERCODE D1909

AutoRanging Digital MultiMeter

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

HM-W536 Install Guide

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Model 3390 Arbitrary Waveform Generator

Water Leak Detection System

Congratulations! Thank you!

Analog Door Phone Model LUADS MAT Code #

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

PowlVac Vacuum Integrity Tester

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Instructions A Amp AC/DC Current Probe

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

OWNER'S MANUAL. AtlasSound.com PA601 COMMERCIAL AMPLIFIER. PA601 Commercial Amplifier. Power. Master

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Technical Update TAA.TU Rev. 1

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

IMPORTANT SAFETY INSTRUCTIONS

How To Use A Power Supply Unit (Upu)

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

User s Manual AURORA 1.2K/2.2K

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

3053 Electrical Safety Training Program Course Outline

Ducoterra Radiant Heating Panel Installation Manual

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

How To Use A Cdm250 Digital Multimeter

Oil and Coolant Circulating Heating System. Model - OCSM

Installation and Operation Guide for PD5100 Automatic Transfer Switch

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

US Installation Manual Smappee Monitor

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

HVAC Clamp Meter. Users Manual

Operating instructions

LED Par 56 Short DMX ORDERCODE 42421

Achat 115MA full-range speaker. user manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

MegaPulse Defib-5P Instruction Manual

15GAL STEEL OIL DRAIN WITH 110V PUMP

1 Introduction. 2 Hazards From Electricity

HOUSING QUALITY STANDARDS (HQS)

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Doorbell Intercom Security System

Operating instructions in the back. PD1020L

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

Evaluating Water-Damaged Electrical Equipment

GenStore Archive Cabinet

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Mini-led spotlight with magnetic base

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Operating Instructions

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.


WARMER or COOKER/WARMER

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Replacing the vacuum tube

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

64-CHANNEL INTEGRATED AMPLIFIER

Transcription:

Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you to make multiple measurement connections, depending on your testing needs. There are three different types of probe tips included with the test leads: Standard probe (quantity: 2) Needle probe (quantity: 2) Spring hook (quantity: 2) Figure 1: Model 1756 General Purpose Test Lead Kit These test leads should only be used by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. The test lead's ratings may be greater than those of the instrument. Do not exceed the ratings of the instrument. Also, do not exceed the maximum signal levels of this accessory (as defined in the Characteristics paragraph) or any attached instrument. Inspect the probes, lead insulation, and insulating sheaths for wear, cracks, or breaks before each use. For maximum safety, never touch or change the leads or power connections when power is applied to the circuit under test. Always turn off test system power and discharge all capacitors before connecting or disconnecting the leads. To prevent exposed voltages or shorting between connections, make sure both ends of the cables are properly connected before applying power. 071339300 / November 2014 *071339300* 1

Model 1756 Test Lead Kit Characteristics Standard probe specifications Maximum voltage 1000 V 20 A II and III Needle probe specifications Maximum voltage 1000 V III Maximum voltage 600 V IV 10 A Spring hook specifications Maximum voltage 1000 V III Maximum voltage 600 V IV 20 A 2 071339300 / November 2014

Model 1756 Test Lead Kit Dimensions Standard probe: Figure 2: Model 1756 standard probe dimensions Needle probe: Figure 3: Model 1756 needle probe dimensions Spring hook probe: Figure 4: Model 1756 spring hook dimensions 071339300 / November 2014 3

Safety precautions The following safety precautions should be observed before using this product and any associated instrumentation. Although some instruments and accessories would normally be used with nonhazardous voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before using the product. Refer to the user documentation for complete product specifications. If the product is used in a manner not specified, the protection provided by the product warranty may be impaired. The types of product users are: Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained. Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of the instrument. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it operating properly, for example, setting the line voltage or replacing consumable materials. Maintenance procedures are described in the user documentation. The procedures explicitly state if the operator may perform them. Otherwise, they should be performed only by service personnel. Service personnel are trained to work on live circuits, perform safe installations, and repair products. Only properly trained service personnel may perform installation and service procedures. Keithley Instruments products are designed for use with electrical signals that are measurement, control, and data I/O connections, with low transient overvoltages, and must not be directly connected to mains voltage or to voltage sources with high transient overvoltages. Measurement Category II (as referenced in IEC 60664) connections require protection for high transient overvoltages often associated with local AC mains connections. Certain Keithley measuring instruments may be connected to mains. These instruments will be marked as category II or higher. Unless explicitly allowed in the specifications, operating manual, and instrument labels, do not connect any instrument to mains. Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test fixtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30 V RMS, 42.4 V peak, or 60 VDC are present. A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring. Operators of this product must be protected from electric shock at all times. The responsible body must ensure that operators are prevented access and/or insulated from every connection point. In some cases, connections must be exposed to potential human contact. Product operators in these circumstances must be trained to protect themselves from the risk of electric shock. If the circuit is capable of operating at or above 1000 V, no conductive part of the circuit may be exposed. Do not connect switching cards directly to unlimited power circuits. They are intended to be used with impedance-limited sources. NEVER connect switching cards directly to AC mains. When connecting sources to switching cards, install protective devices to limit fault current and voltage to the card. Before operating an instrument, ensure that the line cord is connected to a properly-grounded power receptacle. Inspect the connecting cables, test leads, and jumpers for possible wear, cracks, or breaks before each use. When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate main input power disconnect device must be provided in close proximity to the equipment and within easy reach of the operator. For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jumpers, installing or removing switching cards, or making internal changes, such as installing or removing jumpers. Do not touch any object that could provide a current path to the common side of the circuit under test or power line (earth) ground. Always make measurements with dry hands while standing on a dry, insulated surface capable of withstanding the voltage being measured.

For safety, instruments and accessories must be used in accordance with the operating instructions. If the instruments or accessories are used in a manner not specified in the operating instructions, the protection provided by the equipment may be impaired. Do not exceed the maximum signal levels of the instruments and accessories, as defined in the specifications and operating information, and as shown on the instrument or test fixture panels, or switching card. When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. Chassis connections must only be used as shield connections for measuring circuits, NOT as protective earth (safety ground) connections. If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use of a lid interlock. If a screw is present, connect it to protective earth (safety ground) using the wire recommended in the user documentation. The symbol on an instrument means caution, risk of danger. The user must refer to the operating instructions located in the user documentation in all cases where the symbol is marked on the instrument. The symbol on an instrument means caution, risk of electric shock. Use standard safety precautions to avoid personal contact with these voltages. The symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. The symbol indicates a connection terminal to the equipment frame. If this symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be properly disposed of according to federal, state, and local laws. The WARNING heading in the user documentation explains dangers that might result in personal injury or death. Always read the associated information very carefully before performing the indicated procedure. The CAUTION heading in the user documentation explains hazards that could damage the instrument. Such damage may invalidate the warranty. Instrumentation and accessories shall not be connected to humans. Before performing any maintenance, disconnect the line cord and all test cables. To maintain protection from electric shock and fire, replacement components in mains circuits including the power transformer, test leads, and input jacks must be purchased from Keithley Instruments. Standard fuses with applicable national safety approvals may be used if the rating and type are the same. Other components that are not safety-related may be purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through Keithley Instruments to maintain accuracy and functionality of the product). If you are unsure about the applicability of a replacement component, call a Keithley Instruments office for information. To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with no case or chassis (e.g., a data acquisition board for installation into a computer) should never require cleaning if handled according to instructions. If the board becomes contaminated and operation is affected, the board should be returned to the factory for proper cleaning/servicing. Safety precaution revision as of January 2013.