Reconsideration of Application of GDC-4 Exclusion of Local Dynamic Effects to Local Debris Generation



Similar documents
U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN OFFICE OF NUCLEAR REACTOR REGULATION

OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE. July 7, 2016 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, D.C June 1, 2005

June 27, Scott C. Flanders, Director Division of Site Safety and Environmental Analysis Office of New Reactors

DRAFT REGULATORY GUIDE DG-1154 (Proposed Revision 2 of Regulatory Guide 1.128, dated October 1978)

This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and

Evaluation of recent findings on the integrity of pressurised components in nuclear power plants

DRAFT REGULATORY GUIDE

Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP)

REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH. REGULATORY GUIDE (Draft was issued as DG-1226, dated August 2009)

Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C June 26, 2014

Boiling Water Reactor Systems

Published in the Official State Gazette (BOE) number 166 of July 10th 2009 [1]

7.1 General Events resulting in pressure increase 5

The Role of COG in CANDU Fuel Channel Life Management

APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM

Response to NRC Request for Additional Information for the Review of the Fermi 2 License Renewal Application - Set 37

BEFORE THE ATOMIC SAFETY AND LICENSING BOARD PRE-FILED WRITTEN SUPPLEMENTAL REPLY TESTIMONY OF REGARDING CONTENTION NYS-38 / RK-TC-5

Regulatory Guide Configuration Management Plans for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

Robin Dyle. LB60 Workshop February 23, 2011

EQUIPMENT QUALIFICATION

A-Ow INDIA NA MICHIGAN POW!ER. September 18, 2015 AEP-NRC CFR Docket No.:

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD

How To Determine An Operating Safety Certificate

Proposal to Consolidate Post-Fukushima Rulemaking Activities

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, D.C February 1, 2006

Overview. NRC Regulations for Seismic. Applied to San Onofre Nuclear Generating Station. NRC History. How we Regulate

Ontario Power Generation Pickering Fuel Channel Fitness for Service. August 2014

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants

UNITED STATES NUCLEAR REGULATORY COMMISSION ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC July 17, 2012

Government Degree on the Safety of Nuclear Power Plants 717/2013

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION. In the Matter of )

AC : MATERIAL SELECTION FOR A PRESSURE VESSEL

'ii. October 11, MEMORANDUM TO: James Clifford, Chief Project Directorate Section 1-1 Division of Licensing Project Management

3.9.2 Dynamic Testing and Analysis of Systems, Components, and Equipment

SAFETY STANDARDS. of the. Nuclear Safety Standards Commission (KTA) KTA Residual Heat Removal Systems of Light Water Reactors.

WHITE PAPER PROPOSED CONSEQUENCE-BASED PHYSICAL SECURITY FRAMEWORK FOR SMALL MODULAR REACTORS AND OTHER NEW TECHNOLOGIES

Source Term Determination Methods of the Slovenian Nuclear Safety Administration Emergency Response Team

Regulatory Guide Verification, Validation, Reviews, And Audits For Digital Computer Software Used in Safety Systems of Nuclear Power Plants

Apr; 1 5, CFR U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C

REGULATORY GUIDE 5.29 (Draft was issued as DG 5028, dated May 2012) SPECIAL NUCLEAR MATERIAL CONTROL AND ACCOUNTING SYSTEMS FOR NUCLEAR POWER PLANTS

-2- Docket No Attachment: dated March 25, 2002

2. NRC to Entergy, Request for Additional Information ANO1-ISI-024 (MF4022), dated September 12, 2014 (ML14258A020)

Operational Reactor Safety /22.903

This occurrence is considered to be of no significance with respect to the health and safety of the public.

L.S. de Carvalho, J. M de Oliveira Neto 1. INTRODUCTION IAEA-CN-164-5P01

HANFORD TANK WASTE REMEDIATION SYSTEM PRIVATIZATION CO-LOCATED WORKER STANDARDS

Harris Nuclear Plant (HNP) NFPA 805 Transition. NFPA 805 Monitoring Program

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC June 16, 2011

Fact Sheet on U.S. Nuclear Powered Warship (NPW) Safety

REGULATORY GUIDE (Draft was issued as DG-1207, dated August 2012)

Qualification of In-service Inspections of NPP Primary Circuit Components

A Regulatory Approach to Cyber Security

Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3

ENIQ position on. NDE Personnel Re-qualification or a Need to Maintain Proficiency. ENIQ publication no. 49. December 2014

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION OFFICE OF NEW REACTORS WASHINGTON, DC

Results and Insights of Internal Fire and Internal Flood Analyses of the Surry Unit 1 Nuclear Power Plant during Mid-Loop Operations*

C. starting positive displacement pumps with the discharge valve closed.

REGULATORY GUIDE (Draft was issued as DG-1267, dated August 2012)

Roles and Responsibilities of Plant Commissioning, Hydrocarbon Introduction and Acceptance Test Run

Office for Nuclear Regulation

Long Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions

NUCLEAR REGULATORY COMMISSION

Report. November 2013

NRC Submitted: August 10, Federal Register / Vol. 79, No. 52 / Tuesday, March 18, 2014 / Notices

REGULATORY GUIDE OFFICE OF STANDARDS DEVELOPMENT'

WordPerfect Document Compare Summary

How To License A Nuclear Plant

Flow Accelerated Corrosion. in Angra 1 and Angra 2 Nuclear Power Plants. Lucio Ferrari Tomás D. S. Costa

CFD simulation of fibre material transport in a PWR core under loss of coolant conditions

C.I.8.2 Offsite Power System. C.I Description

NRC Cyber Security Policy &

Belgian Stress tests specifications Applicable to all nuclear plants, excluding power reactors 22 June 2011

NEI 06-13A [Revision 0] Template for an Industry Training Program Description

Belgian Stress tests specifications Applicable to power reactors 17 May 2011

Security Requirements for Spent Fuel Storage Systems 9264

Report WENRA Safety Reference Levels for Existing Reactors - UPDATE IN RELATION TO LESSONS LEARNED FROM TEPCO FUKUSHIMA DAI-ICHI ACCIDENT

How To Improve Safety At A Nuclear Power Plant

Spent Fuel Project Office Interim Staff Guidance - 17 Interim Storage of Greater Than Class C Waste

FIRE RISK ASSESSMENT IN GERMANY - PROCEDURE, DATA, RESULTS -

AP1000 European 18. Human Factors Engineering Design Control Document

Nuclear Design Practices and the Case of Loviisa 3

Screen Penetration Test Report

NUCLEAR POWER PLANT SYSTEMS and OPERATION

/All APPLICANTS SHOULD NOTE THAT THE TOUR LENGTH OF A RESIDENT INSPECTOR AT A SINGLE SITE IS LIMITED TO SEVEN (7) YEARS BY COMMISSION POLICY.

GENERAL REGULATIONS ON ENSURING SAFETY OF NUCLEAR POWER PLANTS OPB-88/97, NP (PNAE G ) Cover page. Contents

A Guide to Hazardous Substance Storage Capacity

Safety Analysis for Nuclear Power Plants

ABWR. 3.4 Water Level (Flood) Design

IAEA SAFETY STANDARDS SERIES

December 22, Research and Test Reactor Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION OFFICE OF NEW REACTORS WASHINGTON, DC

IN USE: CABLE AGING MANAGEMENT

AP1000DCDFileNPEm Resource

_Po(fo)'ý. Westinghouse. ,KýA, Your ref: Docket No Our ref: DCP/NRC2117. April 11, 2008

Oil and Gas Pipeline Design, Maintenance and Repair

U.S. Nuclear Regulation after Three Mile Island

Westinghouse. U.S. Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, D.C February 16, 2010

Transcription:

Reconsideration of Application of GDC-4 Exclusion of Local Dynamic Effects to Local Debris Generation April 2010

In October 1987, General Design Criterion (GDC) 4 in Appendix A to 10 C.F.R. Part 50 was revised to allow the use of leak-before-break technology. Specifically: Criterion 4 - Environmental and dynamic effects design bases. Structures, systems, and components important to safety shall be designed to accommodate the effects of and to be compatible with the environmental conditions associated with normal operation, maintenance, testing, and postulated accidents, including loss-of-coolant accidents. These structures, systems and components shall be appropriately protected against dynamic effects, including the effects of missiles, pipe whipping, and discharging fluids, that may result from equipment failures and from events and conditions outside the nuclear power unit. However, dynamic effects associated with postulated pipe ruptures in nuclear power units may be excluded from the design basis when analyses reviewed and approved by the Commission demonstrate that the probability of fluid system piping rupture is extremely low under conditions consistent with the design basis for the piping. [emphasis added] Simply stated, GDC-4 allows local dynamic effects associated with pipe ruptures in Leak-Before- Break qualified piping to be excluded from the design bases. Since 1997, Industry has made multiple requests to consider debris generation as a dynamic effect and, as such, allow its exclusion from the design basis for addressing ECCS performance concerns under GSI-191. While the NRC has accepted debris generation as a local dynamic effect, multiple alternative reasons have been given for rejecting the industry requests. Reason 1: Application to LOCA-generated debris not the intent of current rule This reason was first given in a June 2000 response [1] to a November 1997 request [2] by the PWROG and states that application of the GDC-4 exclusion for LBB piping is limited to the specific examples identified in the rule Statements of Consideration (e.g., removal of pipe whip restraints and jet impingement barriers). June 9, 2000 Letter, Stuart Richards to Karl Jacobs: On the basis of our review, we concluded that although the words in the Statements of Consideration for GDC-4 may be interpreted to be applicable to LOCA-generated debris, it was clearly not the intent of the current rule to do this. The intent of the rule change was to allow the removal of numerous pipe whip restraints and jet impingement barriers, which were believed to negatively affect plant performance and safety while not affecting emergency core cooling systems, containments, or environmental qualification. This reason is countered by the numerous applications of the GDC-4 exclusion that extend beyond the specific changes cited above. In May 2007, NRC prepared the Leak-Before-Break Knowledge Management Document [3] to clearly describe the NRC s policy and practice on the application of LBB. This document acknowledges that application of the GDC-4 exclusion extends beyond removal of pipe whip restraints and jet impingement barriers. 2

LBB Knowledge Management Document, C2. Allowable licensing/design basis changes via LBB applications: When LBB is approved for a particular piping system, applicants are to exclude from the design basis only local dynamic effects associated with postulated pipe ruptures in that system in the nuclear power unit. The local dynamic effects are: Missiles, Pipe whipping, Pipe break reaction forces, and Discharging fluids. For each local dynamic effect listed above, the applicant, upon NRC approval, is permitted to perform a well defined plant activity as a result of excluding this dynamic effect from the design basis. The permitted plant activities are, in the order of local dynamic effects: Remove jet impingement barriers or shields, Remove pipe whip restraints, Redesign pipe connected components, their supports and their internals, and other related changes, and Disregard jet impingement forces on adjacent components [emphasis added], decompression waves within the intact portion of the piping system, and dynamic or nonstatic pressurization in cavities, subcompartments, and compartments In 2006, an Ad Hoc Review Panel was established to review a Differing Professional Opinion (DPO) pertaining to the use of LBB technology in the design of new sump strainers at Oconee Units 1 and 2 [4]. In this instance, GDC-4 was applied to exclude local dynamic effects from LBB piping that had the potential to directly affect the newly installed sump strainer replacement at Oconee. In its response to the DPO, the panel noted that neither GDC-4 nor SRP Section 3.6.3 make distinction among SSCs as to which ones could or could not have dynamic effects excluded from their design basis. The panel found that the sole determining factor for exclusion is whether or not the piping whose rupture would produce the dynamic effects has an acceptably low likelihood of rupture prior to producing a detectable indication of impending failures, i.e., leakage. Reason 1 was also provided in the March 4, 2004 NRC response [5] to NEI requests dated October 4, 2002, April 8, 2003 and October10, 2003. This letter also introduced Reason 2. Reason 2: Application of LBB to LOCA-generated debris is a detriment to defense-indepth principles and would require Commission approval March 4, 2004 Letter, Suzanne Black to Tony Pietrangelo: The end result of the NEI proposal to extend LBB to cover local debris generation would not have the effect of justifying the removal of plant hardware which it is believed negatively affects plant performance. Rather, the NEI proposal asks the NRC staff to limit facility design bases in such a way as to potentially obviate the need for licensees to make modifications to PWR containment sumps which may otherwise be necessary if local debris generation due to the postulated failure of LBB piping were included. This could lead to a condition where common mode failure of ECCS pumps would likely occur due to debris accumulation on the sump screen if a DEGB of a LBB approved line were to occur in service. It is the NRC staff position that although an acceptable LBB evaluation provides assurance with regard to the low probability of piping failure, it is consistent with the 3

Commission s defense-in-depth principle, given the consequences of sump failure, to expect containment sump operability under such circumstances. Thus, the NRC staff concludes that any decision to extend LBB for the purpose of addressing LOCA-generated debris and sump performance to the detriment of defense-in-depth principles is, at a minimum, a policy decision which would require Commission approval. Every application of the GDC-4 exclusion, including the original changes cited in the rule SOCs, arguably act to the detriment to defense-in-depth. The underlying basis given in the March 4, 2004 letter comes down to the potential degree of impact of the proposed change on defense-indepth. In 2004, PWRs still retained their original containment sump screen designs. As noted in the 2004 letter, approval of the LBB exclusion in 2004 could have obviated the need for modifications to PWR containment sumps. This could have represented a significant reduction in defense-in-depth. Since 2004, every PWR has installed significantly larger strainers, reduced debris sources, enhanced operational and emergency procedures, and has performed conservative design analyses to demonstrate the capability of the ECCS system to withstand postulated LOCAs with no credit taken for the GDC-4 exclusion. Application of the GDC-4 exclusion today, no longer presents the potential for a significant reduction in defense-in-depth that was possible in 1994. As such, the NRC staff decision to require Commission approval should be, at a minimum, reevaluated. The March 2004 letter also introduced Reason 3. Reason 3: Primary Water Stress Corrosion Cracking (PWSCC) is a concern March 4, 2004 Letter, Suzanne Black to Tony Pietrangelo: In addition to requiring a policy change that the Commission would have to approve, a significant technical issue also exists with respect to extending the application of LBB technology for the purpose of addressing local debris generation. Since the fall of 2000, operational experience has suggested that piping butt welds made from Alloy 82/182 material may be susceptible to primary water stress corrosion cracking (PWSCC). Domestic experience with this phenomena was observed at the Virgil C. Summer facility as documented in References 8, 9, and 10. At this time, the NRC staff must consider PWSCC to be a potentially active degradation mechanism in all PWR primary piping systems which contain 82/182 butt welds. This would include a significant fraction of the large bore PWR piping systems which were previously approved for LBB. Piping systems which are known to be potentially susceptible to degradation mechanisms such as PWSCC would not be considered as candidate piping systems for LBB approval unless steps had been taken to apply two mitigative methods to address the potential degradation mechanism. GDC 4 provides a clear requirement for prior approval of LBB piping systems as a condition to implementing designs that exclude the dynamic effects associated with postulated pipe ruptures. GDC 4 states that dynamic effects associated with postulated pipe ruptures in nuclear power units may be excluded from the design basis when analyses reviewed and approved by the Commission demonstrate that the probability of fluid system piping rupture is extremely low under conditions consistent with the design basis for the piping. PWSCC is a generic issue potentially affecting all past and future approval of piping systems. In September 2005, the Electric Power Research Institute Materials Reliability Program issued MRP- 4

139, Materials Reliability Program: Primary System Piping Butt Weld Inspection and Evaluation Guideline, [6] that all PWR plants agreed to implement under the industry s Materials Initiatve. MRP-139 provides industry guidance for the inspections of dissimilar metal butt welds in PWR primary systems and discusses volumetric inspection techniques that the industry has qualified for the detection of PWSCC. PWR licensees are addressing the potential for PWSCC to occur in Alloy 82/182 butt welds through a rigorous program of inspecting and mitigating susceptible welds. While PWSCC potentially affects the piping systems for which the GDC-4 exclusion can be applied, it should not be used to selectively eliminate the local dynamic effects allowed under the GDC-4 exclusion. Reason 4: ECCS functional performance is directly affected by the containment sump performance Reason 4 was introduced, almost as a side note, in the LBB Knowledge Document Leak-Before-Break Knowledge Management Document (page 6) Although one may not consider the sumps serving the ECCS and the containment spray system part of the ECCS, the ECCS functional performance is directly affected by the containment sump performance. Therefore, requiring the dynamic effects such as debris generation associated with the postulated DEGBs of LBB-approved piping be included in the sump performance evaluation is a logical extrapolation of the Section C3 limitations on LBB. Section C3 of the LBB Knowledge Management Document (see below) covers the GDC-4 rule limitations on applying LBB to containment design, ECCS and EQ. As noted in section C3, the GDC-4 rule language and SOC allows local dynamic effects to be excluded from the design basis of ECCS hardware. The current GDC-4 rule does not support Reason 4. Leak-Before-Break Knowledge Management Document, Section C3 (page 5) It is apparent that there is no inconsistency if one considers that although pipe whip effects and jet impingement effects are local, their effects on containment pressure boundaries and primary structures are global. This is a good example showing that the distinction between local effects from pipe ruptures and global effects from pipe ruptures are not always clear. Pipe rupture dynamic effects that can be excluded from an LBB applicant s plant design bases for containment, ECCS and EQ are further explained in Reference 5: local dynamic effects uniquely associated with pipe rupture may be deleted from the design basis of containment systems, structures and boundaries, from the design basis of ECCS hardware (such as pumps, valves accumulators, and instrumentation), and from the design bases of safety related electrical and mechanical equipment when leak-before-break is accepted. Similar to Section C2 regarding allowable licensing/design basis changes in LBB applications, local dynamic effects uniquely associated with pipe rupture may be deleted from the design basis of containments, ECCS and EQ. For example, the local dynamic effects of jet impingement deleted from the design basis are not considered in the functional design of ECCS components, such as sump screens. So far, such a list of local dynamic effects or plant activities does not exist. However, considering the limited number of LBB applications related to containments, ECCS, and EQ to date, the staff has found it unnecessary to come up with the list of postulated applications. Instead, the staff will rely on fundamental principles to decide on a case-by-case basis when a proposed area of LBB application appears to be new. 5

References: 1. Letter from Stuart A. Richards, Director, Project Directorate IV and Decommissioning, to Karl Jacobs, Westinghouse Owners Group, Request for Application of Leak Before Break in Response to Draft Generic Letter, Potential for Degradation of the Emergency Core Cooling and Containment Spray Systems Following a Loss of Coolant Accident due to Construction and Protective Coating Deficiencies and Foreign Material in the Containment, June 9, 2000 2. Letter from Thomas V. Greene, Chairman, Westinghouse Owners Group, to Office of Nuclear Reactor Regulation, Request for the Application of Leak Before Break (LBB) in Response to Draft Generic Letter: Potential for Degradation of the Emergency Core Cooling and Containment Spray Systems Following a Loss of Coolant Accident due to Construction and Protective Coating Deficiencies and Foreign Material in the Containment, November 25, 1997. 3. Memorandum from Michele G. Evans, Director, Division of Component Integrity, NRC to John A. Grobe, Associate Director for Engineering and Safety Systems, NRC, Division of Component Integrity Response, May 29, 2007 4. Memorandum from John A. Grobe to J. E. Dyer, Differing Professional Opinion Panel Response to DPO-2006-002, November 13, 2006 5. Letter from Suzanne C. Black, Director, Division of Systems and Safety Analysis, NRC to Anthony Pietrangelo, NEI, Nuclear Energy Institute s Proposals for Determining Limiting Pipe Break Size used In Assessing Debris Generation Following a Design Basis LOCA, March 4, 2004 6. EPRI Report 1015009, Material Reliability Program: Primary System Piping Butt Weld Inspection and Evaluation Guideline (MRP-139), December 2008 6